fischer fixing-systems main-catalogue Pagina 300
Commercieel klantenaanbod**Beste verkopers van Fischer
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
Aircrete anchor FPX-I · High performance steel anchors Loads Aircrete anchor FPX-I Permissible loads¹) and required component dimensions in cracked and non-cracked aerated concrete wall and slab plates. For the design the complete current assessment ETA-12/0456 has to be considered. Type FPX-I M6 , M8 , M10 , M12 hef [mm] 70 fAAC ≥ 3,3 N /mm² / ρm ≥ 0,50 kg/dm³ Fperm [kN] 0.62 fAAC ≥ 4,4 N /mm² / ρm ≥ 0,55 kg/dm³ Fperm [kN] 0.83 fAAC ≥ 3,3 N /mm² / ρm ≥ 0,50 kg/dm³ Fperm [kN] 0.83 fAAC ≥ 4,4 N /mm² / ρm ≥ 0,55 kg/dm³ Fperm [kN] 1.24 Effective anchorage depth Permissible load²) (Fperm) per anchor in cracked AAC-slabs Permissible load²) (Fperm) per anchor in uncracked AAC-slabs 4 Component dimensions Minimum member thickness with drill hole cleaning hmin [mm] 100 Minimum member thickness without drill hole cleaning hmin [mm] 120 Single anchor Minimum spacing a [mm] 600 Minimum edge distance c1 [mm] 125 / 150³) Minimum edge distance orthogonal to c1 c2 [mm] 190 shear and oblique tension only axial tension smin [mm] 100 100 Anchor groups4) with 2 or 4 ancors Actions Minimum spacing between anchor group and 2 single anchors Minimum edge distance c1 [mm] 250 125 / 150³) Minimum spacing a [mm] 750 600 Minimum edge distance orthogonal to c1 c2 [mm] 375 190 ¹) Permissible loads of a single anchor for all load directions. The required partial safety factors for material resistance as well as a partial safety factor for load actions of γL = 1.4 are considered. ²) Grade of the screw resp. threaded rod ≥ 4.8. ³) In case of reinforced plates with a width ≤ 700 mm. 4) Fperm,group = 2 x Fperm,single anchor valid in case of anchor groups with 2 or 4 anchors. Accurate deta see ETA. c1 a c2 ≥ 1,5 x c1 c1 a smin smin c1 a 300
684 Pagina’s | Geldig tot 12/2025 | Vorige pagina | Volgende pagina
Kies uw taal
Juridische kwesties
De fabrikant is exclusief verantwoordelijk voor de inhoud, prijs en artikeldetails van de producten en aanbiedingen in de catalogi. Technische en optische wijzigingen door de fabrikant en fouten voorbehouden.
Aanvraagformulier voor speciale producten
De ToolTeam® Inkoopservice
Bent u op zoek naar producten die wel in de catalogus staan maar niet direct online te koop zijn?Onze aankoopdienst zal u graag een niet-bindend en individueel aanbod doen.
