fischer fixing-systems main-catalogue Pagina 110
Commercieel klantenaanbod**Beste verkopers van Fischer
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
Injection mortar FIS VL · Chemical fixings Loads Injection system FIS VL with threaded rod FIS A in solid and perforated masonry Permissible loads¹) ²) for a single anchor in masonry for pre-positioned installation. For the design the complete current assessment ETA-15/0263 has to be considered. 3 Compressive brick strength Brick raw density Minimum brick dimensions³) Effective anchorage depth Minimum member thickness Maximum installation torque Permissible tensile load4) Permissible shear load4) Minimumspacing5) Characteristic resp. minimum edge distance5) fb ρ (L x B x H) hef hmin Tinst,max Nperm Vperm smin║ / smin┴ ccr = cmin [N/mm²] [kg/dm³] [mm] [mm] [mm] [Nm] [kN] [kN] [mm] [mm] M8 ≥ 12 ≥ 1.8 240 x 115 x 71 ≥ 50 115 5 1.14 0.43 80 / 150 60 M8 ≥ 12 ≥ 1.8 240 x 115 x 71 100 240 5 2.29 0.86 80 / 300 60 M10 ≥ 12 ≥ 1.8 240 x 115 x 71 100 240 15 1.57 0.57 80 / 300 60 M10 ≥ 12 ≥ 1.8 240 x 115 x 71 200 240 15 3.43 0.57 80 / 600 60 M12 ≥ 12 ≥ 1.8 240 x 115 x 71 100 240 15 1.29 0.57 80 / 300 60 M12 ≥ 12 ≥ 1.8 240 x 115 x 71 200 240 15 3.43 0.57 80 / 300 60 M8 with FIS H 12 x 85 K ≥ 12 ≥ 1.4 240 x 175 x 113 85 175 2 0.71 0.71 100 / 115 60 M8 / M10 with FIS H 16 x 85 K ≥ 12 ≥ 1.4 240 x 175 x 113 85 175 2 0.86 1.29 100 / 115 80 M12 with FIS H 20 x 85 K ≥ 12 ≥ 1.4 240 x 175 x 113 85 175 2 0.86 1.29 100 / 115 80 M8 / M10 with FIS H 16 x 130 K ≥ 12 ≥ 1.4 240 x 175 x 113 130 175 2 0.86 1.29 100 / 115 80 M8 with FIS H 12 x 85 K ≥ 10 ≥ 0.9 240 x 175 x 113 85 175 2 1.14 1.14 240 / 115 100 M8 / M10 with FIS H 16 x 85 K ≥ 10 ≥ 0.9 240 x 175 x 113 85 175 2 1.00 1.57 240 / 115 100 M12 with FIS H 20 x 85 K ≥ 10 ≥ 0.9 240 x 175 x 113 85 175 2 1.43 1.71 240 / 115 100 M8 / M10 with FIS H 16 x 130 K ≥ 10 ≥ 0.9 240 x 175 x 113 130 175 2 1.43 1.57 240 / 115 100 M12 with FIS H 20 x 130 K ≥ 10 ≥ 0.9 240 x 175 x 113 130 175 2 1.43 1.71 240 / 115 100 M8 ≥2 ≥ 0.35 - ≥ 100 130 1 0.54 0.43 250 / 250 100 M8 ≥4 ≥ 0.50 - 200 230 8 1.07 0.71 80 / 80 100 M10 ≥2 ≥ 0.35 - ≥ 100 130 2 0.54 0.43 250 / 250 100 M10 ≥4 ≥ 0.50 - 200 230 12 1.79 0.71 80 / 80 100 M12 ≥2 ≥ 0.35 - ≥ 100 130 2 0.71 0.54 250 / 250 100 M12 ≥4 ≥ 0.50 - 200 230 16 1.79 0.71 80 / 80 100 Type Solid sand-lime brick KS, acc. to EN 771-2 Perforated sand-lime brick KSL, acc. to EN 771-2³) Vertically perforated brick Hlz, acc. to EN 771-1³) Aerated concrete acc. to EN 771-46) ¹) The required partial safety factors for material resistance as well as a partial safety factor for load actions of γL = 1.4 are considered. Load values are valid for zinc-plated steel, stainless steel R and highly corrosion-resistant steel HCR. In perforated bricks and hollow blocks threaded rod FIS A in combination with anchor sleeve FIS H K. ²) The given loads are valid for installation and use of fixations in dry masonry - use category d/d - for temperatures in the substrate up to 50 °C (resp. short term up to 80 °C) and drill hole cleaning according to assessment. The given brick types in combination with the permissible loads are an extract of the assessment. ³) More information about, e.g. hole patterns, assortment of anchor sleeves FIS H K see assessment. 4) In the case of combinations of tensile and shear loads, bending moments and reduced edge and axial spacings (anchor groups), the design must be carried out in accordance with the provisions of the complete assessment. 5) Minimum feasible spacing resp. edge distance. Details as well as to the distances to joints see assessment. 6) Cylindrical drill hole. 110
684 Pagina’s | Geldig tot 12/2025 | Vorige pagina | Volgende pagina
Kies uw taal
Juridische kwesties
De fabrikant is exclusief verantwoordelijk voor de inhoud, prijs en artikeldetails van de producten en aanbiedingen in de catalogi. Technische en optische wijzigingen door de fabrikant en fouten voorbehouden.
Aanvraagformulier voor speciale producten
De ToolTeam® Inkoopservice
Bent u op zoek naar producten die wel in de catalogus staan maar niet direct online te koop zijn?Onze aankoopdienst zal u graag een niet-bindend en individueel aanbod doen.