Eurotec catalogue fastening technology Pagina 196
Commercieel klantenaanbod**Beste verkopers van Eurotec
Timber engineering Centre distance Main/Secondary beam multiple connection, single-row IdeeFix Dimensions [mm] Timber Dimensions Min. cross section of secondary beam w [mm] h [mm] Edge and centre distance Edge Centre distance distance [mm] [mm] dc ag vc 30 M12 3 40 M16 5 120 120 60 50 M20 5 160 160 80 30 M12 3 80 150 50 40 M16 5 120 180 60 50 M20 5 160 240 30 M12 3 80 40 M16 5 120 50 M20 5 30 M12 40 50 Main–secondary beam Load-bearing capacity Multiple connection Single-row Drilling depth Drilling depth Perm. Values Char. Values for SB for MB [mm] [mm] Vze. [kN] R23,k [kN] 4,32 8,94 1 10 6,98 14,66 1 15 10,88 21,09 1 10 8,64 17,88 2 15 13,96 29,32 2 30 20 21,76 42,18 2 50 20 10 12,96 26,82 3 60 25 15 20,94 43,98 3 80 80 30 20 32,64 63,27 3 250 50 50 20 10 17,28 35,76 4 120 300 60 60 25 15 27,92 58,64 4 160 400 80 80 30 20 43,52 84,36 4 3 80 300 50 50 20 10 21,60 44,70 5 5 120 360 60 60 25 15 34,90 73,30 5 M20 5 160 480 80 80 30 20 54,40 105,45 5 30 M12 3 80 350 50 50 20 10 25,92 53,64 6 40 M16 5 120 420 60 60 25 15 41,88 87,96 6 50 M20 5 160 560 80 80 30 20 65,28 126,54 6 30 M12 3 80 400 50 50 20 10 30,24 62,58 7 40 M16 5 120 480 60 60 25 15 48,86 102,62 7 50 M20 5 160 640 80 80 30 20 76,16 117,63 7 30 M12 3 80 450 50 50 20 10 34,56 71,52 8 40 M16 5 120 540 60 60 25 15 55,84 117,28 8 50 M20 5 160 720 80 80 30 20 87,04 168,72 8 80 80 50 50 20 7 60 25 80 30 50 20 60 25 80 80 200 50 240 60 160 320 3 80 M16 5 M20 5 30 M12 40 M16 50 dc is the diameter and the total height of the connector ag is the metric connection thread of the connector vc is the height of the integrated anti-twist system – Fully threaded screw, GoFix® FK IF 30 5,0 x 40 mm - IF 40 6,0 x 60 mm - IF 50 8,0 x 90 mm The connection is drawn together using a threaded rod or constructionscrew with a DIN 440 R washer MB–SB connection as a mortise joint with simultaneous absorption of tensile forces Rk characteristic value calculated according to DIN 1052:2004-08 Timber pk 380 kg/m3 Nze. recommended permissible load R,k x 0,8 kmod : 1,3 ym : 1,4. Favtor 1,4 average load safety factor Please note: The stated values are planning aids. Projects must only be calculated by authorised persons. 196 Number of Connectors pc.
444 Pagina’s | Geldig tot 12/2024 | Vorige pagina | Volgende pagina
Kies uw taal
Juridische kwesties
De fabrikant is exclusief verantwoordelijk voor de inhoud, prijs en artikeldetails van de producten en aanbiedingen in de catalogi. Technische en optische wijzigingen door de fabrikant en fouten voorbehouden.
Aanvraagformulier voor speciale producten
De ToolTeam® Inkoopservice
Bent u op zoek naar producten die wel in de catalogus staan maar niet direct online te koop zijn?Onze aankoopdienst zal u graag een niet-bindend en individueel aanbod doen.
