CELO main catalog Pagina 117
Commercieel klantenaanbod**Producten uit de cataloguspagina
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
CELO ResiTHERM® 37 technical data ResiTHERM® 37S Installation parameters ResiTHERM® 37/120 ResiTHERM® 37/160 ResiTHERM® 37/200 Anchor length Ld [mm] 125 245 285 325 7KLFNQHVVRILQVXODWLRQPDWHULDO LQFOH[WHUQDOSODVWHU hD [mm] 0 601) - 120 1201) - 160 1601) - 200 Anchor Ø dnom [mm] 37 Drill hole Ø d0 [mm] 39 - 40 Drill hole depth h1 ͡ [mm] 130 Anchorage depth hnom [mm] 125 ± 102) [mm] M12 hVPLQPD[ [mm] 35 - 80 223) Connecting thread Screw insertion depth of M12 threaded stud 7KLFNQHVVRIͤ[WXUH tͤ[͠ [mm] RIFOHDUDQFHKROHLQͤ[WXUH df ͡ [mm] Required volume of ResiFIX VY per ResiTHERM® 37 ,QVWDOODWLRQWRUTXHIRUPRXQWLQJWKHͤ[WXUH 13 [ml] Tinst͠ ca. 140 [Nm] 20 ResiTHERM® 37 may be cut up to 40 mm if needed. ResiTHERM® 37/120 M12: If thickness of insulation material is 60 mm, set 20 mm deeper. 2) Minimum anchorage depth of 115 mm is possible (see ETA assessment) 3) When using a threaded stud with L=70 mm. Otherwise a longer threaded stud or a longer metric screw can be used. 1) Loads and displacements/deflections ResiTHERM®37: approved system with injection system ResiFIX VY SF Building material System Thickness of insulation material [mm] Permissible tension load Hollow brick T1.0-240 HLZ 12 (Format 12 DF) Hollow brick T10-300 HLZ 6 (Format 10 DF) Aerated concrete AAC2-0,352) Aerated concrete AAC4-0,552) Single fastening Single fastening Single fastening Single fastening all all all all Permissible pressure load Hollow brick T1.0-240 HLZ 12 (Format 12 DF) Hollow brick T10-300 HLZ 6 (Format 10 DF) Single fastening Single fastening all all Permissible shear load Single fastening Hollow brick T1.0-240 HLZ 12 (Format 12 DF) Double fastening3) Single fastening Hollow brick T10-300 HLZ 6 (Format 10 DF) Double fastening3) 0 120 160 200 0 120 160 200 0 120 160 200 0 120 160 200 * Movement of ResiTHERM® 37 in load direction at permissible load. Recommended loads include the partial safety factor on action of ɶF = 1,4. Not part of the ETA-assessment. 3) Spacing of 77 mm (standard awning console). 4) Ǝv0 ,QLWLDOGHIOHFWLRQƎY͜= long-term deflection 1) 2) Application of ResiTHERM® 37 in solid building materials is possible. Contact CELO for details. 116 Recommended loads1) Deflection at recommended load* Nper [kN] ɷN0ͬɷEь [mm] 1,71 0,86 1,21 2,12 0,60/ 1,30 0,60/ 1,20 0,14/ 0,28 0,32/ 0,64 Fper [kN] ɷF0ͬɷ&ь[mm] 1,71 0,86 0,60/ 1,30 0,60/ 1,20 Vper [kN] ɷv0ͬɷǀь [mm] 4) 0,86 0,34 0,34 0,26 0,51 0,43 0,34 0,41 0,43 0,26 0,26 0,17 0,17 0,11 0,11 0,09 0,20/ 0,30 2,00/ 4,10 2,10/ 4,30 3,40/ 6,70 0,60/ 1,20 1,60/ 3,20 0,70/ 1,40 1,40/ 2,90 0,00/ 0,10 1,30/ 2,60 1,70/ 2,50 2,00/ 4,00 0,10/ 0,20 0,20/ 0,30 0,20/ 0,30 0,30/ 0,50
316 Pagina’s | Geldig tot 03/2023 | Vorige pagina | Volgende pagina
Kies uw taal
Juridische kwesties
De fabrikant is exclusief verantwoordelijk voor de inhoud, prijs en artikeldetails van de producten en aanbiedingen in de catalogi. Technische en optische wijzigingen door de fabrikant en fouten voorbehouden.
Aanvraagformulier voor speciale producten
De ToolTeam® Inkoopservice
Bent u op zoek naar producten die wel in de catalogus staan maar niet direct online te koop zijn?Onze aankoopdienst zal u graag een niet-bindend en individueel aanbod doen.