CELO main catalog Pagina 108
Commercieel klantenaanbod**Beste verkopers van CELO Befestigungssysteme GmbH
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
ResiTHERM® Permissible tension load and pressure load ResiTHERM® 16 1) at 24°/40° 2) M16 anchor rod in 8.8 applied injection mortar ResiFIX VY SF acc. ETA10/0134 applied injection mortar ResiFIX VY SF acc. ETA-15/0320 Base material Concrete C20/25 3) Solid sand-lime brick KS KS28-2,0 3) Solid brick MZ 202,0 1) [kN] [k[kN] [k[kN] 4,57 2,00 2,29 [kN] [kN] Hollow sand-lime brick KSL 12-1,4 4) Hollow brick HLZ 12-1,25 4) Aerated concrete AAC 2 3) [[kN]] [kN] N] [[kN] kN] 1,65 1,11 0,71 [kN] N] [[kN] kN] Permissible tension load Nper Insulation thickness e 60-300 mm Permissible pressure load Pper Insulation thickness e [kN] [[kN]] 60 - 220 mm 5,14 2,00 2,29 1,65 1,11 0,71 221 - 300 mm 5,14 2,00 2,29 1,65 1,11 0,71 80 100 100 130 130 100 Min. anchorage depth hef /RDGVLQFOXGHWKHSDUWLDOVDIHW\IDFWRUVRIWKHPDWHULDOJLYHQLQWKH(7$DVZHOODVDSDUWLDOVDIHW\IDFWRUIRUWKHDFWLRQVRIƍ) 2) For other temperature ranges see ETA-assessment. 3) In full material the tension load resistance can be used also for the pressure load resistance. 4) ,QKROORZPDWHULDOVWKHSUHVVXUHORDGUHVLVWDQFHVSHFLͤHGLQWKH(7$FDQEHDSSOLHGLIWKHVHWWLQJGHSWKLVGHHSHQRXJKWRLQFOXGHPLQLPXPZHEVZLWKWKHLQMHFWLRQ mortar. If the setting depth is lower and does not include 4 webs, then the pressure load resistance must be reduced. 1) Permissible tension load and pressure load ResiTHERM® 12 1) at 24°/40° 2) M16 anchor rod in 8.8 applied injection mortar ResiFIX VY SF acc. ETA10/0134 applied injection mortar ResiFIX VY SF acc. ETA-15/0320 Base material Concrete C20/25 3) Solid sand-lime brick KS KS28-2,0 3) Solid brick MZ 202,0 1) [kN] [k[kN] [k[kN] 5,14 2,00 2,00 [kN] [kN] [kN] 5,14 2,00 2,00 Hollow sand-lime brick KSL 12-1,4 4) Hollow brick HLZ 12-1,25 4) Aerated concrete AAC 2 3) [[kN]] [kN] N] [[kN] kN] 1,65 1,11 0,71 [[kN]] [kN] N] [[kN] kN] 1,65 1,11 0,71 Permissible tension load Nper Insulation thickness e 60 - 220 mm Permissible pressure load Pper Insulation thickness e 60 - 120 mm 121 - 160 mm 5,14 2,00 2,00 1,65 1,11 0,71 161 - 220 mm 2,86 2,00 2,00 1,65 1,11 0,71 70 100 100 130 130 100 Min. anchorage depth hef /RDGVLQFOXGHWKHSDUWLDOVDIHW\IDFWRUVRIWKHPDWHULDOJLYHQLQWKH(7$DVZHOODVDSDUWLDOVDIHW\IDFWRUIRUWKHDFWLRQVRIƍ) 2) For other temperature ranges see ETA-assessment. 3) In full material the tension load resistance can be used also for the pressure load resistance. 4) ,QKROORZPDWHULDOVWKHSUHVVXUHORDGUHVLVWDQFHVSHFLͤHGLQWKH(7$FDQEHDSSOLHGLIWKHVHWWLQJGHSWKLVGHHSHQRXJKWRLQFOXGHPLQLPXPZHEVZLWKWKHLQMHFWLRQ mortar. If the setting depth is lower and does not include 4 webs, then the pressure load resistance must be reduced. 1) 107
316 Pagina’s | Geldig tot 03/2023 | Vorige pagina | Volgende pagina
Kies uw taal
Juridische kwesties
De fabrikant is exclusief verantwoordelijk voor de inhoud, prijs en artikeldetails van de producten en aanbiedingen in de catalogi. Technische en optische wijzigingen door de fabrikant en fouten voorbehouden.
Aanvraagformulier voor speciale producten
De ToolTeam® Inkoopservice
Bent u op zoek naar producten die wel in de catalogus staan maar niet direct online te koop zijn?Onze aankoopdienst zal u graag een niet-bindend en individueel aanbod doen.