Rothenberger Maincatalog Pagina 332
Commercieel klantenaanbod**Beste verkopers van Rothenberger
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
excl. verzending
GOOD TO KNOW Refrigerant data from CFC-alternative refrigerants Refrigerant Composition ODP GWP R22 (HFCKW refrigerant) CHCLF₂ 0.05 1,810 CF₃CH2F 0 1,430 R32 (HFKW-chlorine-free refrigerant) CH2F2 0 675 R404A (HFKW-chlorine-free blends) 52 % R143a, 44 % R125, 4 % R134a 0 3,922 0 3,985 R407C (HFKW-chlorine-free blends) 23 % R32, 25 % R125, 52 % R134a R134a (HFKW-chlorine-free refrigerant) R507 (HFKW-chlorine-free blends) R410A (HFKW-chlorine-free blends) 50 % R143a, 50 % R125 50 % R32, 50 % R125 0 1,774 0 2,088 Temperature glide 7.5 K 0.2 K ODP = Ozone Depletion Potential (degree in which the ozone layer is destroyed) GWP = Global Warming Potential (degree in which it contributes to the greenhouse effect) Instructions for safe and proper use of the refrigerants Refrigerant • Wear protective gloves and safety goggles • Do not let refrigerant come in contact with skin • Do not inhale high concentrations of vapours (Lack of oxygen causes a narcotic effect and is a danger to life) • Do not smoke around refrigerant • Working place / room must be thoroughly aired, if necessary extracted Refrigerant bottles • Secure against accidents, do not throw • Do not expose to direct sunlight and do not place near radiators or other heat sources • Do not use open flame • Do not disassemble or remove valves • Damaged bottles need to be properly returned • Close empty containers Air-conditioners • Air-conditioner leaks need to be repaired immediately • Do not allow refrigerant to leak while filling or doing maintenance work • In high concentrations (for example pipe burst), leave the room and do not enter again until it has been properly ventilated • Only do brazing work together with protective nitrogen gas and only in well ventilated areas Flare connections Normal flare size in accordance with JIS B8607:2008 Flare outer diameter in relationship to the pipe diameter Pipe outer diameter mm / inch 13 Metric 6 mm 1 mm 10 mm 1 mm 16 mm 1 mm 8 mm 1 mm 12 mm 18 mm 1/4″ 6.35 mm 3/8″ 9.52 mm 5/16″ 1/2″ 5/8″ 3/4″ 332 Wall thickness mm / inch 7.94 mm Flare outer diameter with R22-, R134a-, R404-, R407C air-conditioners 8.5 mm 11.1 mm 13.6 mm 9.1 mm 11.1 mm 13.2 mm 1 mm 15.3 mm 16.5 mm 1 mm 22.0 mm 22.7 mm 0.35″ 0.35″ 0.35″ 19.5 mm 9.0 mm 11.0 mm 13.0 mm 12.70 mm 0.35″ 16.2 mm 19.05 mm 0.35″ 23.3 mm 15.88 mm Flare outer diameter with R410A air-conditioners 0.35″ 19.4 mm 19.2 mm 9.1 mm 11.1 mm 13.2 mm 16.6 mm 19.7 mm 24.0 mm
396 Pagina’s | Geldig tot 12/2026 | Vorige pagina | Volgende pagina
Kies uw taal
Juridische kwesties
De fabrikant is exclusief verantwoordelijk voor de inhoud, prijs en artikeldetails van de producten en aanbiedingen in de catalogi. Technische en optische wijzigingen door de fabrikant en fouten voorbehouden.
Aanvraagformulier voor speciale producten
De ToolTeam® Inkoopservice
Bent u op zoek naar producten die wel in de catalogus staan maar niet direct online te koop zijn?Onze aankoopdienst zal u graag een niet-bindend en individueel aanbod doen.