Eurotec catalogue fastening technology Pagina 180

Commercieel klantenaanbod**
Eurotec catalogue fastening technology Pagina 180Pagina 181
Toon producten
search
keyboard_arrow_up
/ 444

Producten uit de cataloguspagina

keyboard_arrow_down
  • 16MM (1)
  • 45mm (1)
keyboard_arrow_down
  • 25mm (1)
  • 49mm (1)
keyboard_arrow_down
  • S235JR (2)
944901
Offerte aanvragen
Commercieel klantenaanbod**
944905
Offerte aanvragen
Commercieel klantenaanbod**
Bekijk alle Eurotec producten
Timber engineering Glue-laminated timber beams CLT ceiling Notes: The tables illustrate the ‘Lifting horizontal ceiling elements’ load case (lifting from a horizontal position leading to vertical suspension). The connectors must be screwed in flush with the surface, plus perpendicular to the component surface. Operating instructions for the ball supporting bolt Warning! Ball supporting bolts are designed for lifting and holding individual loads (not people!!!). In addition, they are not suitable for continuous load rotation. Contamination (e.g. grinding sludge, oil and emulsion deposits, dust, etc.) can impair the function of ball supporting bolts. Damaged ball supporting bolts can put people’s lives at risk. Before each use, ball supporting bolts must be inspected for visible defects (e.g. deformations, fractures, cracks, damage, missing balls, corrosion, function of the unlocking mechanism). Damaged ball supporting bolts must be withdrawn from further use. Handling and loading Press the button (A) to release the balls. The balls are locked again by releasing the button (A). Please note: The button (A) is locked when the spring force has caused it to spring back to its original position. Do not press the button when loaded! The load values F1 / F2 / F3 (see page 2) apply to lifting in a steel receptacle and x min. = 1.5 mm Maintenance Ball supporting bolts must be subjected to a safety inspection by a competent person at least once a year. Visual inspection Deformations, fractures, cracks, missing / damaged balls, corrosion, screw connection damage on the shackle. Functional test The balls’ locking and unlocking mechanism must close automatically by spring force. Full shackle mobility is guaranteed. d1 l1 d2 d3 d4 min. l2 l3 l4 l5 l6 l7 l8 x min.* x max.* D H11 F1 kN* F2 kN* F3 kN* 20,0 50 24,50 30,0 25,00 36,5 52,0 32,6 36 56 114,0 1,5 25 20,0 10,0 8,5 6,5 19,70 * with five-fold protection against breakage Original EC conformity mark The product complies with the regulations set down in the EC Directive 2006/42/EC. 180 Make: Type: Ball supporting bolt EH 22350 Applied standards: DIN EN 13155

444 Pagina’s | Geldig tot 12/2024 | |

PDF Download (52MB)
Pagina opslaan als PDF
Offerte aanvragen
(vrijblijvend)

Kies uw taal

Juridische kwesties

Het aanbod is uitsluitend gericht op zakelijke klanten, bedrijven, openbare instellingen, handelaars en freelancers. Alle prijzen in de catalogi zijn exclusief BTW, verzendkosten en eventuele toeslagen.
De fabrikant is exclusief verantwoordelijk voor de inhoud, prijs en artikeldetails van de producten en aanbiedingen in de catalogi. Technische en optische wijzigingen door de fabrikant en fouten voorbehouden.

Aanvraagformulier voor speciale producten

Personal-Quote Personal-Quote

De ToolTeam® Inkoopservice

Bent u op zoek naar producten die wel in de catalogus staan ​​maar niet direct online te koop zijn?
Onze aankoopdienst zal u graag een niet-bindend en individueel aanbod doen.


Gelieve alle verplichte velden in te vullen (rood onderstreept)
keyboard_arrow_down
Gelieve alle verplichte velden in te vullen (rood onderstreept)