REMKO Complete Catalog Pagina 297
Offerta per clienti commerciali**Prodotti della pagina del catalogo
escluse le spese di spedizione
escluse le spese di spedizione
escluse le spese di spedizione
escluse le spese di spedizione
escluse le spese di spedizione
escluse le spese di spedizione
Technical data Price group 9 Area of application, heating 5) 1 to 6 kW 6 to 9 kW Device type Version System Operating mode WKF 80 Single split Air/water Heating/cooling/ hot water Series Smart Control Touch Series 6 kW Series No 1/1 Series -20 to +37 6,0 (0,9-7,5) A+++/A++ 5,2 3,5 14,8 211/140 6,40 / 5,21 5,30 / 4,13 4,20 / 3,50 4,44 / 3,49 +60 +15 to +45 4,0 (0,8-6,5) 4,5 / 2,7 7,5 / 4,1 +7 R32 1,0 / 0,68 1/4 / 1/2 40 10 230/1~/50 230/1~/50 3,0 1,10 5,40 16/10 80 1,10 3 1 1/4 male thread 28 -/54 -/51 -/32 -/29 700/1010/370 500/800/500 41,0 / 62,0 WKF 170 Single split Air/water Heating/cooling/ hot water Series Smart Control Touch Series 9 kW Series No 1/1 Series -20 to +37 11,0 (3,0-16,8) A+++/A++ 5,3 3,3 31,2 215/142 13,50 / 5,15 11,30 / 4,12 8,80 / 3,45 9,38 / 3,51 +60 +15 to +45 12,0 (3,1-13,2) 12,4 / 3,17 14,2 / 4,31 +7 R32 2,5 / 1,70 3/8 / 3/4 40 10 230/1~/50 400/3~/50 6,2 2,62 12,96 3x 20/10 60 2,30 3 1 1/4 male thread 35 -/61 -/57 -/39 -/35 1450/1085/425 500/800/500 47,0 / 95,0 7.280,– € 264045 WKF 100 WKF 130 Single split Single split Air/water Air/water Heating/cooling/ Heating/cooling/ hot water hot water Series Series Smart Control Smart Control Touch Touch Series 6 kW Series 6 kW Series Series No No 1/1 1/1 Series Series -20 to +37 -20 to +37 8,0 (1,5-10,0) 9,0 (2,0-12,5) A+++/A+++ A+++/A+++ 5,4 5,2 3,4 3,5 18,3 23,8 211/131 212/147 7,90 / 5,26 10,30 / 5,07 5,90 / 4,16 8,70 / 4,14 5,20 / 3,56 6,90 / 3,47 5,49 / 3,51 7,14 / 3,49 +60 +60 +15 to +45 +15 to +45 6,0 (1,5-8,2) 8,0 (2,1-10,5) 7,2 / 2,8 8,5 / 2,7 9,5 / 4,2 10,8 / 3,9 +7 +7 R32 R32 1,6 / 1,10 1,8 / 1,20 3/8 / 5/8 3/8 / 5/8 40 40 10 10 230/1~/50 230/1~/50 230/1~/50 230/1~/50 3,7 4,1 1,51 2,07 6,55 8,85 20/10 20/10 80 70 1,40 1,80 3 3 1 1/4 male thread 1 1/4 male thread 28 28 -/57 -/58 -/54 -/55 -/35 -/36 -/32 -/33 845/1165/370 845/1165/370 500/800/500 500/800/500 43,0 / 73,0 45,0 / 80,0 Similar to RAL 9006/7021 8.240,– € 9.230,– € 264055 264065 Control systems Smart-Web Ethernet interface Smart-Count Heat meter WKF 80 198,– € 248120 320,– € 259010 WKF 100 198,– € 248120 320,– € 259010 WKF 130 198,– € 248120 320,– € 259010 WKF 170 198,– € 248120 320,– € 259010 General accessories BVT set, loose For the integration of a second heat generator Smart-Cool For active cooling, use with cooling function WKF 80 318,– € 260081 345,– € 259085 WKF 100 318,– € 260081 345,– € 259085 WKF 130 318,– € 260081 345,– € 259085 WKF 170 318,– € 260081 345,– € 259085 WKF 100 720,– € 1690 WKF 130 720,– € 1690 WKF 170 720,– € 1690 Inverter technology Heat pump manager Electrical auxiliary heater Preparation for domestic water Integrated domestic water tank Number of outdoor/indoor modules Night operation (power control) Application limit, heating Heating capacity Energy efficiency rating heating W35/55 4) Energy efficiency ratio SCOP 35 °C Energy efficiency ratio SCOP 55 °C 65% EE share according to GEG fulfilled, up to max. heating load Seasonally related room heating energy efficiency W35/55 Heating capacity/COP for A7/W35 1) Heating capacity/COP for A2/W35 1) Heating capacity/COP for A-7/W35 1) Heating capacity/COP for A-7/W34 6) Flow temperature heating water max. Application limit, cooling Cooling capacity Cooling capacity/EER for A35/W7 1) Cooling capacity/EER for A35/W18 1) Flow temperature cooling water min. Refrigerant 2) Initial filling quantity/CO2 equivalent Refrigerant piping connection (per outdoor unit) Max. refrigerant pipe length (per outdoor unit) Max. refrigerant pipe height (per outdoor unit) Power supply indoor unit Power supply outdoor unit Max. power consumption Nominal power consumption heating for A7/W35 Nominal current consumption heating for A7/W35 Circuit protection on-site, outdoor/indoor module External pressure loss max. (heating system) Rated volume flow rate of water at ∆t 5 K Max. operating pressure, water Hydraulic connection supply/return flow Required pipe diameter (copper pipe) Sound power level, indoor unit/outdoor unit 3) Sound power level, indoor unit/outdoor unit, lowering mode Sound pressure level, indoor unit/outdoor unit 3) Sound pressure level, indoor unit/outdoor unit, lowering mode Dimensions H/W/D, outdoor unit Dimensions H/W/D, indoor unit Weight, indoor unit/outdoor unit Standard colour outdoor unit Design line GRAPHIT Ref. no. Accessories °C kW kW % kW / kW / kW / kW / °C °C kW kW / kW / °C kg / t Inch m m V/Ph/Hz V/Ph/Hz kW kW A A inert kPa m³/h bar Inch mm dB(A) dB(A) dB(A) dB(A) mm mm kg 9 to 12 kW 12 to 16 kW 11.660,– € 264075 Price group 9 Commissioning and maintenance service Price group 10 Device type REMKO CheckServ Technical device handover incl. 5-year manufacturer's warranty for Germany/Netherlands WKF 80 720,– € 1690 Note: For further services see REMKO CheckServ. Prices valid for German mainland, prices for islands on request. 1) 5) 2) COP / EER according to EN 14511 GWP = 675 Total heat requirement, inlet flow 35°C, monoenergetic 3) Distance 5 m, half sphere, A7/W55 6) COP / EER according to EN 14825 4) Average, composite system W35/55°C incl. Smart Control 295
436 pagine | Valido fino a 12/2026 | Previous page | Pagina successiva
Selezionare la lingua
Questioni legali
Il produttore è esclusivamente responsabile del contenuto, del prezzo e dei dettagli degli articoli dei prodotti e delle offerte presentati nei cataloghi. Con riserva di modifiche tecniche e ottiche da parte del produttore e salvo errori.
Modulo di richiesta per prodotti speciali
Il servizio di acquisto di ToolTeam®
State cercando dei prodotti che sono mostrati nel catalogo ma che non possono essere acquistati direttamente online?Il nostro servizio di approvvigionamento sarà lieto di farvi un’offerta individuale e non vincolante.
