REMKO Complete Catalog Pagina 132
Offerta per clienti commerciali**Prodotti della pagina del catalogo
escluse le spese di spedizione
escluse le spese di spedizione
escluse le spese di spedizione
escluse le spese di spedizione
escluse le spese di spedizione
escluse le spese di spedizione
REMKO KWK EC ZW SERIES Ceiling chests in 2-pipe or 4-pipe design with infinitely variable EC fan for installation into false ceilings REMKO KWK EC ZW SERIES Ceiling units for installation in ceiling voids – The perfect, discrete solution With their low installation height, these ceiling units are the ideal, invisible climate control solution for offices, banks, or hotels. The integrated EC motor ensures energy-efficient operation and allows for continuous fan speed adjustment, significantly enhancing comfort and user-friendliness. The rectangular air outlet is designed for adjustable air outlet grilles, enabling customized air distribution. A regenerable insert filter at the air intake efficiently cleans the air. The internal tangential fan provides multi-stage airflow adjustment for precise room adaptation. The diagonally installed copper-aluminium heat exchanger is designed for medium temperatures up to 80°C. With the option to integrate a heating coil, the units can easily be upgraded to a 4-pipe system. The coil connections are available on both sides of the con- Technical data kW kW m³/h Pa dB(A) V/Ph/Hz kPa m³/h m³/h kPa kPa Inch Inch l mm mm kg Room temperature controller RR-22.2 Room temperature sensor For controllers RR-21(.2) and RR-22(.2) Inlet flow temperature sensor For controllers RR-21(.2) and RR-22(.2) Modbus board built-in Infrared remote control for Modbus board Cable remote control Standard for Modbus board Cable remote control Touch for Modbus board Room temperature controller RR-25 .2 for in-wall installation Fault message module SB-1 1) 130 Invisible mounting in intermediate spaces ■ Low installation height ■ Can be positioned flexibly ■ Minimum weight ■ Low-noise unit operation ("Silent" mode) ■ Particularly narrow dimensions ■ Simple equipping of the unit in a 4-pipe design ■ For horizontal installation arrangement ■ Infinitely variable EC fans ■ BMS connection via Modbus board, optional KWK 135 EC ZW KWK 175 EC ZW KWK 225 EC ZW KWK 265 EC ZW KWK 345 EC ZW 1,3 1,8 2,2 2,6 3,4 1,6 2,1 2,6 3,0 3,8 84-298 98-321 133-394 147-432 196-580 76 78 92 93 100 19-38 19-38 42-20 20-42 21-38 230/1~/50 230/1~/50 230/1~/50 230/1~/50 230/1~/50 IPX0 IPX0 IPX0 IPX0 IPX0 Water; max. 35% ethylene glycol; max. 35% propylene glycol 1500 1500 1500 1500 1500 0,2 0,3 0,4 0,5 0,6 0,28 0,35 0,44 0,51 0,65 14,4 17,1 18,3 19,4 26,8 18,0 20,2 21,7 22,1 29,8 1/2 1/2 1/2 1/2 1/2 1/2 1/2 1/2 1/2 1/2 0,7 0,7 1 1 1,4 20 20 20 20 20 215/545/450 215/545/450 215/745/450 215/745/450 215/945/450 11,4 11,9 14,2 15,0 20,2 720,– € 810,– € 845,– € 940,– € 975,– € 1664600 1664610 1664620 1664630 1664640 Price group 5 Control systems Precision room temperature controller RR-21.2 3) ■ Price group 5 Device type Cooling capacity 1) 2) Heating capacity 1) 3) Air flow rate min.-max. Pressure max. Sound pressure level min.-max. 4) Power supply Protection class Operating medium Operation pressure max. agent Nominal flow rate, medium, cooling 2) Nominal flow rate, medium, heating 3) Nominal pressure loss, internal cooling 2) Nominal pressure loss, internal heating 3) Medium connection, inlet Medium connections, outlet Medium contents, cooling Condensate drainage connection Dimensions H/W/D Weight Price Ref. no. Accessories densate-insulated housing. A matching valve assembly for 2-pipe and 4-pipe systems is available as an accessory for precise cooling performance regulation. NEW NEW NEW NEW NEW KWK 135 EC ZW 261,– € 1611401 147,– € 1611403 41,– € 1611380-1 37,– € 1611381-1 449,– € 1657062 196,– € 1657063 238,– € 1657064 348,– € 1657065 430,– € 1611421 206,– € 1611506 KWK 175 EC ZW 261,– € 1611401 147,– € 1611403 41,– € 1611380-1 37,– € 1611381-1 449,– € 1657062 196,– € 1657063 238,– € 1657064 348,– € 1657065 430,– € 1611421 206,– € 1611506 KWK 225 EC ZW 261,– € 1611401 147,– € 1611403 41,– € 1611380-1 37,– € 1611381-1 449,– € 1657062 196,– € 1657063 238,– € 1657064 348,– € 1657065 430,– € 1611421 206,– € 1611506 KWK 265 EC ZW 261,– € 1611401 147,– € 1611403 41,– € 1611380-1 37,– € 1611381-1 449,– € 1657062 196,– € 1657063 238,– € 1657064 348,– € 1657065 430,– € 1611421 206,– € 1611506 KWK 345 EC ZW 261,– € 1611401 147,– € 1611403 41,– € 1611380-1 37,– € 1611381-1 449,– € 1657062 196,– € 1657063 238,– € 1657064 348,– € 1657065 430,– € 1611421 206,– € 1611506 Rated volume flow rate of medium; 0 % glycol concentration; max. air volume flow rate 2) Room temperature TK 27 °C, FK 19 °C; medium inlet 7 °C, medium outlet 12 °C Room temperature TK 20 °C, FK 14 °C; medium inlet 45 °C, medium outlet 40 °C 4) Measured in 100 m3 room with a reverberation period of 0.3 seconds, distance 1.0 m
436 pagine | Valido fino a 12/2026 | Previous page | Pagina successiva
Selezionare la lingua
Questioni legali
Il produttore è esclusivamente responsabile del contenuto, del prezzo e dei dettagli degli articoli dei prodotti e delle offerte presentati nei cataloghi. Con riserva di modifiche tecniche e ottiche da parte del produttore e salvo errori.
Modulo di richiesta per prodotti speciali
Il servizio di acquisto di ToolTeam®
State cercando dei prodotti che sono mostrati nel catalogo ma che non possono essere acquistati direttamente online?Il nostro servizio di approvvigionamento sarà lieto di farvi un’offerta individuale e non vincolante.
