REMKO Complete Catalog Pagina 128
Offerta per clienti commerciali**Prodotti della pagina del catalogo
escluse le spese di spedizione
escluse le spese di spedizione
escluse le spese di spedizione
escluse le spese di spedizione
escluse le spese di spedizione
escluse le spese di spedizione
escluse le spese di spedizione
escluse le spese di spedizione
REMKO KWK EC (DM) SERIES Wall and ceiling chests in 2-pipe or 4-pipe design with infinitely variable EC fan REMKO KWK EC (DM) SERIES Wall and ceiling units in modern design The wall and ceiling units offer versatile installation options – either vertically on the wall or horizontally on the ceiling. They are ideally suited for offices, meeting rooms, banks, shops, and private living areas. Thanks to the modern and energy-efficient EC motor, the integrated fan can be continuously adjusted, greatly enhancing user comfort. REMKO wall and ceiling units impress with advanced technology and high flexibility in installation. The connections for the medium are located on the left side of the housing by default. The controller can be mounted either inside the unit or on the wall, and swapping the connections and controller sides is also possible without any issues. The stylish casing is finished in white, and the air outlet grid is made of white plastic. Air enters the unit through a regenerable filter. A Technical data kW kW m³/h dB(A) V/Ph/Hz kPa m³/h m³/h kPa kPa Inch Inch l mm mm kg Room temperature controller RR-22.2 Room temperature sensor For controllers RR-21(.2) and RR-22(.2) Inlet flow temperature sensor For controllers RR-21(.2) and RR-22(.2) Room temperature controller RR-25 .2 for in-wall installation Modbus board built-in Infrared remote control for Modbus board Cable remote control Standard for Modbus board Cable remote control Touch for Modbus board Fault message module SB-1 1) 126 The ideal solution for optically discreet air conditioning ■ Low-noise unit operation ("Silent" mode) ■ Simple equipping of the unit in a 4-pipe design ■ For horizontal and vertical installation ■ Infinitely variable EC fans ■ BMS connection via Modbus board, optional KWK 135 EC (DM) KWK 175 EC (DM) KWK 225 EC (DM) KWK 265 EC (DM) KWK 345 EC (DM) 1,3 1,8 2,2 2,6 3,4 1,6 2,1 2,6 3,0 3,8 84-298 98-321 133-394 147-432 196-580 19-38 19-38 20-42 20-42 21-38 230/1~/50 230/1~/50 230/1~/50 230/1~/50 230/1~/50 IPX0 IPX0 IPX0 IPX0 IPX0 Water; max. 35% ethylene glycol; max. 35% propylene glycol 1500 1500 1500 1500 1500 0,2 0,3 0,4 0,5 0,6 0,28 0,35 0,44 0,51 0,65 14,4 17,1 19,3 19,4 26,8 18,0 20,2 21,7 22,1 29,8 1/2 1/2 1/2 1/2 1/2 1/2 1/2 1/2 1/2 1/2 0,7 0,7 1 1 1,4 20 20 20 20 20 477/670/220 477/670/220 477/870/220 477/870/220 477/1070/220 13,8 (15,0) 14,3 (15,5) 16,7 (18,3) 17,5 (19,1) 22,8 (24,8) Similar to RAL 9010 780,– € 870,– € 915,– € 995,– € 1.050,– € 1664400 1664410 1664420 1664430 1664440 825,– € 910,– € 950,– € 1.040,– € 1.090,– € 1664500 1664510 1664520 1664530 1664540 Price group 5 Control systems Built-in controller RR-21.2E Not suitable for DM variant Precision room temperature controller RR-21.2 3) ■ Price group 5 Device type Cooling capacity 1) 2) Heating capacity 1) 3) Air flow rate min.-max. Sound pressure level min.-max. 4) Power supply Protection class Operating medium Operation pressure max. agent Nominal flow rate, medium, cooling 2) Nominal flow rate, medium, heating 3) Nominal pressure loss, internal cooling 2) Nominal pressure loss, internal heating 3) Medium connection, inlet Medium connections, outlet Medium contents, cooling Condensate drainage connection Dimensions H/W/D Weight Series colour KWK EC Chest unit for wall/upright installation Ref. no. KWK EC DM Chest unit for ceiling installation Ref. no. Accessories particularly quiet, 3-stage tangential fan ensures even air distribution and maximises the output performance. The copper-aluminium coil is designed for medium temperatures up to a maximum of 80°C. By installing a heating coil, the units can easily be upgraded for a 4-pipe system. NEW NEW NEW NEW NEW KWK 135 EC (DM) 298,– € 1665004 261,– € 1611401 147,– € 1611403 41,– € 1611380-1 37,– € 1611381-1 430,– € 1611421 449,– € 1657062 196,– € 1657063 238,– € 1657064 348,– € 1657065 206,– € 1611506 KWK 175 EC (DM) 298,– € 1665004 261,– € 1611401 147,– € 1611403 41,– € 1611380-1 37,– € 1611381-1 430,– € 1611421 449,– € 1657062 196,– € 1657063 238,– € 1657064 348,– € 1657065 206,– € 1611506 KWK 225 EC (DM) 298,– € 1665004 261,– € 1611401 147,– € 1611403 41,– € 1611380-1 37,– € 1611381-1 430,– € 1611421 449,– € 1657062 196,– € 1657063 238,– € 1657064 348,– € 1657065 206,– € 1611506 KWK 265 EC (DM) 298,– € 1665004 261,– € 1611401 147,– € 1611403 41,– € 1611380-1 37,– € 1611381-1 430,– € 1611421 449,– € 1657062 196,– € 1657063 238,– € 1657064 348,– € 1657065 206,– € 1611506 KWK 345 EC (DM) 298,– € 1665004 261,– € 1611401 147,– € 1611403 41,– € 1611380-1 37,– € 1611381-1 430,– € 1611421 449,– € 1657062 196,– € 1657063 238,– € 1657064 348,– € 1657065 206,– € 1611506 Rated volume flow rate of medium; 0 % glycol concentration; max. air volume flow rate 2) Room temperature TK 27 °C, FK 19 °C; medium inlet 7 °C, medium outlet 12 °C Room temperature TK 20 °C, FK 14 °C; medium inlet 45 °C, medium outlet 40 °C 4) Measured in 100 m3 room with a reverberation period of 0.3 seconds, distance 1.0 m
436 pagine | Valido fino a 12/2026 | Previous page | Pagina successiva
Selezionare la lingua
Questioni legali
Il produttore è esclusivamente responsabile del contenuto, del prezzo e dei dettagli degli articoli dei prodotti e delle offerte presentati nei cataloghi. Con riserva di modifiche tecniche e ottiche da parte del produttore e salvo errori.
Modulo di richiesta per prodotti speciali
Il servizio di acquisto di ToolTeam®
State cercando dei prodotti che sono mostrati nel catalogo ma che non possono essere acquistati direttamente online?Il nostro servizio di approvvigionamento sarà lieto di farvi un’offerta individuale e non vincolante.
