Eurotec catalogue fastening technology Pagina 218
Offerta per clienti commerciali**
Mostra i prodotti
I migliori venditori da Eurotec
946070
Richiesta offerta
Offerta per clienti commerciali**
946079
Richiesta offerta
Offerta per clienti commerciali**
946071
Richiesta offerta
Offerta per clienti commerciali**
945959
Richiesta offerta
Offerta per clienti commerciali**
975611
Richiesta offerta
Offerta per clienti commerciali**
110000
Richiesta offerta
Offerta per clienti commerciali**
954211
Richiesta offerta
Offerta per clienti commerciali**
964575
Richiesta offerta
Offerta per clienti commerciali**
Eurotec Vite per tetti Topduo testa piatta - acciaio rivestito speciale - TX40 - 8,0 x 165 mm 945870
945870
Richiesta offerta
Offerta per clienti commerciali**
945979
Richiesta offerta
Offerta per clienti commerciali**
905750
Richiesta offerta
Offerta per clienti commerciali**
945340
Richiesta offerta
Offerta per clienti commerciali**
200036
Richiesta offerta
Offerta per clienti commerciali**
110361
Richiesta offerta
Offerta per clienti commerciali**
110121
Richiesta offerta
Offerta per clienti commerciali**
200065
Richiesta offerta
Offerta per clienti commerciali**
905575
Richiesta offerta
Offerta per clienti commerciali**
944890
Richiesta offerta
Offerta per clienti commerciali**
200085
Richiesta offerta
Offerta per clienti commerciali**
499985
Richiesta offerta
Offerta per clienti commerciali**
954045
Richiesta offerta
Offerta per clienti commerciali**
964552
Richiesta offerta
Offerta per clienti commerciali**
499999
Richiesta offerta
Offerta per clienti commerciali**
975623
Richiesta offerta
Offerta per clienti commerciali**
500000
Richiesta offerta
Offerta per clienti commerciali**
904790
Richiesta offerta
Offerta per clienti commerciali**
500055
Richiesta offerta
Offerta per clienti commerciali**
905555
Richiesta offerta
Offerta per clienti commerciali**
905737
Richiesta offerta
Offerta per clienti commerciali**
945040
Richiesta offerta
Offerta per clienti commerciali**
800356
Richiesta offerta
Offerta per clienti commerciali**
800379
Richiesta offerta
Offerta per clienti commerciali**
800464
Richiesta offerta
Offerta per clienti commerciali**
945956
Richiesta offerta
Offerta per clienti commerciali**
800469
Richiesta offerta
Offerta per clienti commerciali**
945978
Richiesta offerta
Offerta per clienti commerciali**
800496
Richiesta offerta
Offerta per clienti commerciali**
946142
Richiesta offerta
Offerta per clienti commerciali**
954100
Richiesta offerta
Offerta per clienti commerciali**
901990
Richiesta offerta
Offerta per clienti commerciali**
Vedi tutti i prodotti di Eurotec
Timber engineering KonstruX ST with cylinder head and drill point 8,0 mm: main/secondary beam joints Dimensions Main / secondary beam connection SB MB SB HSB HMB MB WSB WMB Characteristic value of the joint‘s loadbearing capacity Rk acc. to ETA-11/0024 a2= min. 40 mm, a2,c= min. 24 mm, k= min. 12 mm d1 x L [mm] 8,0 x 245 8,0 x 295 8,0 x 330 8,0 x 375 8,0 x 400 8,0 x 430 8,0 x 480 min. WSB [mm] Pair (n) 80 16,43 1 100 30,66 2 44,16 3 200 min. WMB [mm] 100 min. HMB [mm] 200 m [mm] β° Rv,k a) b) - [kN] 140 min. HSB [mm] 87 45 180 57,21 4 80 17,44 1 32,55 2 46,88 3 180 60,74 4 80 17,44 1 100 32,55 2 46,88 3 100 140 140 220 260 120 140 220 260 104 117 45 45 180 60,74 4 80 17,44 1 32,55 2 46,88 3 100 140 280 160 280 133 45 180 60,74 4 80 17,44 1 32,55 2 46,88 3 100 140 300 160 300 141 45 180 60,74 4 80 17,44 1 32,55 2 46,88 3 180 60,74 4 80 17,44 1 100 32,55 2 46,88 3 60,74 4 100 140 140 320 360 180 180 320 360 180 152 170 45 45 Calculation according to ETA-11/0024. Wood density ρk= 380 kg/m³. All mechanical values provided should be viewed as subject to the assumptions that have been made and represent example calculations. All values are calculated minimum values and are subject to typographical and printing errors. a) The characteristic values of the load-bearing capacity Rk cannot be treated as equivalent to the max. possible load (the max. force). Characteristic values of the load-bearing capacity Rk should be reduced to dimensioning values Rd with regard to the usage class and class of the load duration: Rd= Rk · kmod / γM. The dimensioning values of the load-bearing capacity Rd should be contrasted with the dimensioning values of the loads (Rd ≥ Ed). Example: Characteristic value for constant load (dead weight) Gk= 2,00 kN and variable load (e. g. snow load) Qk= 3,00 kN. kmod= 0,9. γM= 1,3. → Dimensioning value of the load Ed= 2,00 · 1,35 + 3,00 · 1,5= 7,20 kN. The load-bearing capacity of the joint is therefore considered to have been demonstrated if Rd ≥ Ed. → min Rk= Rd · γM / kmod i.e. the characteristic minimum value is calculated based on: min Rk= Rd · γM / kmod → Rk= 7,20 kN · 1,3/0,9= 10,40 kN → comparison with table values. b) estimated with an efficient quantity of pairs of screws: n0,9. Please note: These are planning aids. Projects must only be calculated by authorised persons. 218
444 pagine | Valido fino a 12/2024 | Pagina precedente | Pagina successiva
Selezionare la lingua
Questioni legali
L’offerta è rivolta esclusivamente a clienti commerciali, aziende, istituzioni pubbliche, commercianti e liberi professionisti. Tutti i prezzi nei cataloghi sono al netto di IVA, spese di spedizione e supplementi se applicabili.
Il produttore è esclusivamente responsabile del contenuto, del prezzo e dei dettagli degli articoli dei prodotti e delle offerte presentati nei cataloghi. Con riserva di modifiche tecniche e ottiche da parte del produttore e salvo errori.
Il produttore è esclusivamente responsabile del contenuto, del prezzo e dei dettagli degli articoli dei prodotti e delle offerte presentati nei cataloghi. Con riserva di modifiche tecniche e ottiche da parte del produttore e salvo errori.
Modulo di richiesta per prodotti speciali
Il servizio di acquisto di ToolTeam®
State cercando dei prodotti che sono mostrati nel catalogo ma che non possono essere acquistati direttamente online?Il nostro servizio di approvvigionamento sarà lieto di farvi un’offerta individuale e non vincolante.
Si prega di compilare tutti i campi obbligatori (sottolineati in rosso)
keyboard_arrow_down
Si prega di compilare tutti i campi obbligatori (sottolineati in rosso)