ENDRESS Power generator aggregates catalogue Pagina 56
Offerta per clienti commerciali**Prodotti della pagina del catalogo
Energy storage system 12 -24 kVA f EES D 12/12 ENDRESS energy storage system Model EES D 12/12 EES D 20/20 EES D 24/24 Order No. 610 014 610 015 610 016 Technical specifications Power section Continuous output at 25°C kVA/kW 10.5 15 21 Power (1) at 25°C kVA/kW 12 18 24 Peak power (2) at 25°C kVA/kW 31.5 45 63 Rated voltage 400 / 230 V 400 / 230 V 400 / 230 V Nominal output current in independent operation 17 A 26 A 35 A Nominal output current in combined 32 A operation 63 A 63 A Protection Class IP 54 IP 54 IP 54 Protective measures RCD (residual-current-operated protective device) RCD (residual-current-operated protective device) RCD (residual-current-operated protective device) Design according to DGUV 203-032 B B (Protective separation with residual- (Protective separation with residualcurrent operated protective device) current operated protective device) B (Protective separation with residualcurrent operated protective device) Rated capacity 12 kWh 20 kWh 24 kWh Rated nominal capacity (optionally available) 16, 20, 24 kWh 24 kWh – Battery cycles 1400 1400 1400 Operating temperature range -20°C – 55°C -20°C – 55°C -20°C – 55°C Charging time, approx. 2.5 h 2.5 h 2.5 h Energy storage system Battery system Assembly Weight approx. 800 kg 1300 kg 1500 kg Dimensions L x W x H 1200 x 800 x 1700 mm 1200 x 800 x 1700 mm 1200 x 800 x 1700 mm Input sockets 1x CEE 400 V / 32A 1x 230 V / 16A device plug 1x CEE 400 V / 63A 1x 230 V / 16A device plug 1x CEE 400 V / 63A 1x 230 V / 16A device plug sockets 1x 230 V / 16 A (3) 1x CEE 400 V / 16 A 1x CEE 400 V / 32 A 1x 230 V / 16 A (3) 1x CEE 400 V / 16 A 1x CEE 400 V / 32 A 1x CEE 400 V / 63 A 1x 230 V / 16 A (3) 1x CEE 400 V / 16 A 1x CEE 400 V / 32 A 1x CEE 400 V / 63 A Monitoring LCD display AC voltage, AC current for each AC voltage, AC current for each AC voltage, AC current for each phase, phase, battery capacity, discharging phase, battery capacity, discharging battery capacity, discharging current, current, charging current current, charging current charging current Remote start input 2 conductors Options Remote monitoring Timer function for energy saving system Timer function for the remote starting of a generator Socket with load shedding of secondary consumers (1) approx. 30 min. (2) approx. 3 sec. (2) Socket also used for maintaining the battery charge Ideal for: Tunnel and nigh construction sites, events, power supply for residential containers, tools and electrical equipment. 56 Recharging time: approx. 2.5 h (recharging time varies as it depends on the recharging method) 2 conductors 2 conductors Version C according to DGUV Information 203-032 as an IT system with residual current protection device (includes an earthing stake) and insulation monitoring with status signalling Version C according to DGUV Information 203-032 as an IT system with residual current protection device (includes an earthing stake) Insulation monitoring with IT system switching off or Version B as per DGUV Information 203-032 Ecological: No CO2 emissions, reduced noise emissions Economical: Lower generator running times for less fuel consumption, an optimised generator utilisation rate for lower signs of wear Safety: Overload, over-temperature and short-circuit protection, deep-discharge protection
76 pagine | Valido fino a 12/2023 | Previous page | Pagina successiva
Selezionare la lingua
Questioni legali
Il produttore è esclusivamente responsabile del contenuto, del prezzo e dei dettagli degli articoli dei prodotti e delle offerte presentati nei cataloghi. Con riserva di modifiche tecniche e ottiche da parte del produttore e salvo errori.
Modulo di richiesta per prodotti speciali
Il servizio di acquisto di ToolTeam®
State cercando dei prodotti che sono mostrati nel catalogo ma che non possono essere acquistati direttamente online?Il nostro servizio di approvvigionamento sarà lieto di farvi un’offerta individuale e non vincolante.
