fischer fixing-systems main-catalogue Page 641
Offre client commercial**Produits de la page du catalogue
hors Expédition
hors Expédition
hors Expédition
hors Expédition
hors Expédition
hors Expédition
hors Expédition
hors Expédition
hors Expédition
Gas actuated fastening tool FGC 100 · Power tools Accessories Accessories for fixings Fuel cell FC 165 EWI plug TFD EWI nose FGC 100 - N EWI Magnetic nose piece supplement FGC 100 – N magnetic Length Technical details Item No. Contents [mm] Item Fuel cell FC 165 553416 165 For more than 1,100 fixings — EWI plug TFD 30 554928 30 To fix insulation material with a thickness of 50 mm, on soft concrete < C30/37 with DFN 40 504 EWI plug TFD 50 554929 50 Gvz with 5 µm coating thickness, for hard concrete ≥ C30/37 and steel, shaft diameter 3.0 mm, nail length 32 mm 504 EWI nose FGC 100-N EWI 554869 — For the use of fischer EWI plugs TFD 30 and TFD 50 1 Magnetic nose piece supplement FGC 100-N magnetic 553715 — For the use with metal washers 2 Metal washer FGC 100 554935 — It prevents fixture pull-over and is used with the magnetic nose piece supplement to fix wire mesh or membranes. 1,008 Cleaning kit FGC 100 553718 — 150 ml Cleaner, 100 ml Lubricating Oil and tool rubber sealing rings 1 Loads Standard nails DFN and high-performance nails DFNH Recommended loads¹) of a single nail in the respective building material as multiple use with at least 6 nails per attachment part. Building material Setting depth hef [mm] DFN DFNH Concrete C20/25²) ≥ 14 0.10 - Concrete C50/60²) Recommended tension load ¹) Frec [kN] ≥ 16 0.18 - ≥ 18 0.20 0.22 ≥ 20 0.20 0.50 ≥ 14 - 0.12 ≥ 17 - 0.18 ≥ 18 - 0.22 ≥ 20 0.50 - ≥ 25 0.68 - ≥ 27 0.80 - ≥ 29 0.95 - ≥ 14 0.10 - ≥ 16 0.16 - ≥ 18 0.19 - ≥ 20 0.19 - ≥8 - 0.96 Minimum member thickness hmin [mm] 60 60 Minimum edge distance cmin [mm] 70 70 Minimum member thickness hmin [mm] - 4 Minimum edge distance cmin [mm] - 14 Wood tfix [mm] 25 25 Metal sheet tfix [mm] 2.5 2.5 Solid sand-lime brick KS DIN EN 771-2 / KS 16 998 x 200 x 623 mm Solid brick Mz DIN EN 771-1 / Mz 20, DF Steel S235JR acc. to EN 10025-2 15 Member thickness and edge distance for concrete Member thickness and edge distance for steel Maximum fixture thickness ¹) Required safety factors are considered. Not for safety relevant single point fixings. All visible setting errors must be corrected. Use only in dry areas. To confirm the technical data, setting and load tests are recommended. ²) The load values in concrete are valid for tension and shear load. 641
684 Pages | Valable jusqu’au 12/2025 | Page précédente | Page suivante
Choisissez votre langue
Probleme juridique
Le fabricant est exclusivement responsable du contenu, des prix et des détails des articles et des offres présentés dans les catalogues. Sous réserve de modifications techniques et optiques du fabricant et sous réserve d’erreurs.
Formulaire de demande de produits spéciaux
Le service d’approvisionnement ToolTeam®
Vous recherchez des produits qui figurent dans le catalogue mais ne peuvent pas être achetés directement en ligne ?Notre service d’approvisionnement se fera un plaisir de vous faire une offre individuelle et sans engagement.
