Timber engineering Tension strap HB60 – static values F1 F1 Load direction F1 Connection Timber-Concrete Wood side connection Concrete side connection Char. Shear carrying apacity [kN] Paneltwistec CH Ø 5 x 120 n=9 Anchor nails Ø 4 x 40 n=6 Anchor nails Ø 4 x 50 n=6 Rock Rock Bolt anchor concrete screws concrete screws Ø 12 x 110 Ø 12,5 x 120 Ø 12,5 x 120 n=1 n=2 n=1 Rock Rock Bolt anchor Bolt anchor concrete screws concrete screws Ø 12 x 110 Ø 12 x 110 Ø 12,5 x 120 Ø 12,5 x 120 n=1 n=2 n=2 n=1 Rock Rock Bolt anchor Bolt anchor concrete screws concrete screws Ø 12 x 110 Ø 12 x 110 Ø 12,5 x 120 Ø 12,5 x 120 n=1 n=2 n=2 n=1 20,8* 20,8* 12,6 20,8* 9,3 9,3 9,3 9,3 11,0 11,0 Anchor nails Ø 4 x 60 n=6 Rock Rock Bolt anchor concrete screws concrete screws Ø 12 x 110 Ø 12,5 x 120 Ø 12,5 x 120 n=2 n=2 n=1 11,0 11,0 11,4 11,4 Load direction F1 Connection Timber-Concrete Wood side connection Concrete side connection Anchor nails Ø 4 x 60 n=6 Bolt anchor Ø 12 x 110 n=1 Angle-bracket screw Ø 5 x 40 n=6 Rock Rock Bolt anchor Bolt anchor concrete screws concrete screws Ø 12 x 110 Ø 12 x 110 Ø 12,5 x 120 Ø 12,5 x 120 n=1 n=2 n=2 n=1 Angle-bracket screw Ø 5 x 50 n=6 Rock Rock Bolt anchor Bolt anchor concrete screws concrete screws Ø 12 x 110 Ø 12 x 110 Ø 12,5 x 120 Ø 12,5 x 120 n=1 n=2 n=2 n=1 Angle-bracket screw Ø 5 x 60 n=6 Rock Rock Bolt anchor Bolt anchor concrete screws concrete screws Ø 12 x 110 Ø 12 x 110 Ø 12,5 x 120 Ø 12,5 x 120 n=1 n=2 n=2 n=1 Bolt anchor Ø 12 x 110 n=2 Char. Shear carrying 11,4 11,4 10,9 10,9 10,9 10,9 12,0 12,0 12,0 12,0 13,1 13,1 12,6 13,1 apacity [kN] * Concrete edge breakout for cracked concrete The load-bearing capacities were determined based on ETA-19/0020 Characteristic load-bearing capacity in kN, wood strength class 350 kg/m³ char. Gross density. The minimum distances between the connectors and the edges according to EC5 must be complied with. Please note: Verify the assumptions made. The stated values, and type and number of joining devices are based on preliminary measurements. Projects are to be dimensioned exclusively by authorised persons in accordance with the State Building Code. As per LBauO, please contact a qualified structural engineer for a paid proof of stability. We will be happy to refer you to someone. Tension strap HB70 – static values F1 F1 Load direction F1 Connection Timber-Concrete Wood side connection Concrete side connection Char. Shear carrying apacity [kN] Paneltwistec CH Ø 5 x 120 n=12 Rock Rock Bolt anchor concrete screws concrete screws Ø 12 x 110 Ø 12,5 x 120 Ø 12,5 x 120 n=1 n=2 n=1 20,8* 20,8* 12,6 Anchor nails Ø 4 x 40 n=8 Anchor nails Ø 4 x 50 n=8 Rock Rock Bolt anchor Bolt anchor concrete screws concrete screws Ø 12 x 110 Ø 12 x 110 Ø 12,5 x 120 Ø 12,5 x 120 n=1 n=2 n=2 n=1 Rock Rock Bolt anchor Bolt anchor concrete screws concrete screws Ø 12 x 110 Ø 12 x 110 Ø 12,5 x 120 Ø 12,5 x 120 n=1 n=2 n=2 n=1 20,8* 12,5 12,5 12,5 12,5 14,7 14,7 12,6 Anchor nails Ø 4 x 60 n=8 Rock Rock Bolt anchor concrete screws concrete screws Ø 12 x 110 Ø 12,5 x 120 Ø 12,5 x 120 n=2 n=2 n=1 14,7 15,2 15,2 Load direction F1 Connection Timber-Concrete Wood side connection Concrete side connection Anchor nails Ø 4 x 60 n=8 Bolt anchor Ø 12 x 110 n=1 Angle-bracket screw Ø 5 x 40 n=8 Rock Rock Bolt anchor Bolt anchor concrete screws concrete screws Ø 12 x 110 Ø 12 x 110 Ø 12,5 x 120 Ø 12,5 x 120 n=1 n=2 n=2 n=1 Angle-bracket screw Ø 5 x 50 n=8 Rock Rock Bolt anchor Bolt anchor concrete screws concrete screws Ø 12 x 110 Ø 12 x 110 Ø 12,5 x 120 Ø 12,5 x 120 n=1 n=2 n=2 n=1 Angle-bracket screw Ø 5 x 60 n=8 Rock Rock Bolt anchor Bolt anchor concrete screws concrete screws Ø 12 x 110 Ø 12 x 110 Ø 12,5 x 120 Ø 12,5 x 120 n=1 n=2 n=2 n=1 Bolt anchor Ø 12 x 110 n=2 Char. Shear carrying 12,6 15,2 17,2 17,1 12,6 17,1 18,2 18,2 12,6 18,2 19,0 19,0 12,6 19,0 apacity [kN] * Concrete edge breakout for cracked concrete The load-bearing capacities were determined based on ETA-19/0020 Characteristic load-bearing capacity in kN, wood strength class 350 kg/m³ char. Gross density. The minimum distances between the connectors and the edges according to EC5 must be complied with. Please note: Verify the assumptions made. The stated values, and type and number of joining devices are based on preliminary measurements. Projects are to be dimensioned exclusively by authorised persons in accordance with the State Building Code. As per LBauO, please contact a qualified structural engineer for a paid proof of stability. We will be happy to refer you to someone. 254
444 Pages | Valable jusqu’au 12/2024 | Page précédente | Page suivante
Choisissez votre langue
Probleme juridique
Le fabricant est exclusivement responsable du contenu, des prix et des détails des articles et des offres présentés dans les catalogues. Sous réserve de modifications techniques et optiques du fabricant et sous réserve d’erreurs.
Formulaire de demande de produits spéciaux
Le service d’approvisionnement ToolTeam®
Vous recherchez des produits qui figurent dans le catalogue mais ne peuvent pas être achetés directement en ligne ?Notre service d’approvisionnement se fera un plaisir de vous faire une offre individuelle et sans engagement.