Ganter Norm Standard Parts - Catalogue Página 1618

Oferta para clientes comerciales**
Ganter Norm Standard Parts - Catalogue Página 1618Página 1619
Mostrar productos
search
keyboard_arrow_up
/ 2210

Productos de la página del catálogo

keyboard_arrow_down
  • J (>0.1% Pb) (1)
keyboard_arrow_down
  • J (>0.1% Pb) (1)
-24% Ganter Norm Ganter Tapones de ventilación con filtro y válvula doble GN 764-81-BA-FD
764-81-BA-FD
45,30 €
excluyendo el transporte
59,95 € MSRP
3 Variants
Ver todos los productos de Ganter Norm
Description of function 3.1 GN 775 Breather Caps continued The overpressure inside the container ensures that the air volume flowing in or escaping owing to fluctuations of the oil level is kept to a minimum. This reduces filter fouling and substantially increases the useful filter life, especially in a dusty environment. Also, a container under pressure has a positive effect on the function of the pump and prevents foaming. 3.3 The air filter prevents the oil from being polluted from the outside (dust). The filter is made of PU foam with a filtration of 40 μm. 3.4 This is achieved by combining two valves (non-return / bypass valve). The inlet valve opens at a vacuum of 30 mbar or greater. The second valves opens at an overpressure > 350 / 700 mbar. 3.2 Breather caps GN 775 with double valve are normally used if the oil container is under pressure and if outside air has to flow back in to compensate for the vacuum caused by falling oil level. 3.5 The valve seal ensures that no oil will leak even if the oil is heavily agitated or during transport. When turning in the cap, the key must not be inserted. For turning out the cap, turn the cap clockwise to the stop (latching mechanism). Insert the key into the recess in this position. This will connect the screw-in thread and the cap, allowing the breather cap to be removed. 3.7 Caution: 3.8 When turning in the cap, a latching mechanism ensures that the specified torque is not exceeded. It is set for optimum sealing effect. Turning out the cap without a key is no longer possible. 3.6 Assembly instruction 3.9 The key is designed such that, when inserted, it can be clipped to the cap. Pressure curve Δp [mbar] in the container as factor of the air flow rate [l/min.] at a valve opening pressure of 350 or 700 mbar. 3.5 Controlling, Venting, Sealing of Liquids and Gases | Page 1617

2210 Páginas | Válido hasta 12/2026 | |

PDF Download (122MB)
Guardar la página como PDF
Solicitar oferta
(no vinculante)

Elija su idioma

Cuestiones jurídicas

La oferta está destinada exclusivamente a clientes comerciales, empresas, instituciones públicas, comerciantes y autónomos. Todos los precios de los catálogos no incluyen el IVA, los gastos de envío ni los recargos, si procede.
El fabricante es el único responsable del contenido, el precio y los detalles de los productos y ofertas presentados en los catálogos. Sujeto a cambios técnicos y ópticos por parte del fabricante y a excepción de errores.

Formulario de pedido de productos especiales

Personal-Quote Personal-Quote

El servicio de compras ToolTeam®

¿Busca productos que aparecen en el catálogo pero que no se pueden comprar directamente en línea?
Nuestro servicio de compras estará encantado de hacerle una oferta individual y no vinculante.


Por favor, rellene todos los campos obligatorios (subrayados en rojo)
keyboard_arrow_down
Por favor, rellene todos los campos obligatorios (subrayados en rojo)