zoom_in
zoom_out
fullscreen
-19%
Remko WP WKF 180 AM, 3P/ 400 V Smart-WP, versatile in use 255061
Sku: T-385080
€4,587.56 (excl. legal VAT, excl. Shipping)
€5,650.00 MSRP
In stock,ready for shipping within 48h
Package
Product variants
| Sku: | Name: | SKU manufacturer: | ||
|---|---|---|---|---|
|
T-385071 | WP WKF 180 compact AM Smart-WP, versatile in use | 255031 | |
|
T-385073 | WP WKF 180 compact S-Line AM Smart-WP, versatile in use | 255036 | |
|
T-385085 | WP WKF 180 AM S-Line Smart-WP, versatile in use | 255066 |
doneSmart-WP
doneMade in Germany
Remko WP WKF 180 AM, 3P/ 400 V Smart-WP 255061, versatile application
Content:
1 Package
Shipping:
€273.87 Versandservice to United Kingdom
For orders from €1,000.00 order total plus €34.45 Customs MRN registration
Lieferung:
Provider:
Sales and delivery by ToolTeam Köln
Payment methods:
Returns:
Security:
Product data
Manufacturer:
REMKO GmbH & Co. KG
Condition:
NEW
Sku:
T-385080
SKU manufacturer:
255061
GTIN Code (EAN):
4026415051334
Weight:
110,00 Kg
All information relating to products from REMKO GmbH & Co. KG. Technical and optical modifications of the manufacturer and errors reserved.
This page has been machine-translated, the original german version can be found here, please also note the Translation Disclaimer.
Product description
Inverter-controlled outdoor module for heat absorption from the ambient air. Outdoor installation. Housing and frame are made of sturdy galvanised sheet steel with additional weather-resistant polyester stove enamelling and internal sound insulation. Large removable panelling elements. Colour grey-white, similar to RAL 9002.
Technical description:
The air inlet is via the evaporator with protection against external influences by a wire grille. High-performance heat exchanger, manufactured as an evaporator from refrigerator-quality copper pipe with pressed-on aluminium fins. L-shaped with multiple injection to increase performance. Smooth-running speed-controlled axial fan with a plastic impeller, statically and dynamically balanced with horizontal contact protection grille. Weather-protected drive motor, maintenance-free and equipped with thermal overload protection. Suction gas-cooled, DC rotary piston compressor, speed-controlled via inverter. The use of neodymium magnets has increased torque and minimised friction losses. Pulse-width modulation for optimum sinusoidal characteristics. Mounted on vibration dampers for low vibration and quiet running, with high efficiency, motor protection against overcurrent and thermal overload, equipped with sound insulation as standard.
The inverter technology enables high efficiency at low outside temperatures. Protected against liquid hammer on the suction side by a generously dimensioned liquid separator. Safety chain consisting of a temperature sensor, overheating protection and overcurrent protection. All functions are monitored and controlled by a microprocessor. Microprocessor-controlled on-demand defrosting by means of a circuit reversal ensures low defrosting cycles.
Refrigeration circuit with R 410 A refrigerant with filter, receiver, 4-way changeover valve. Service/filling connections with lockable valves. Electronic expansion valve for pressure reduction installed in the outdoor unit. The refrigeration circuit is pressure-tested, leak-tested, dried, evacuated and filled with refrigerating machine oil. Refrigeration circuit pre-filled for a maximum single pipe length of 10 metres. The maximum permissible pipe length is 50 metres.
Included as standard:
Remko-Smart Control
Safety group with SIV, automatic air vent and pressure gauge
2 shut-off valves 1‘ with thermometer
Dirt filter 1’
Fill and drain tap ½”
1 external sensor
1 immersion sensor (intended for DHW heating)
Available as accessories:
Refrigerant lines
Floor or wall bracket for outdoor module
Condensate drip tray without/with oil separator
Electric condensate drain heater
Technical performance data:
Type designationREMKO WKF 180
Heating output [kW]3.1-17.7
Nominal heating output at A12/W35 1) [kW]16.02
Nominal heating output at A7/W35 1) [kW]14, 02
Nominal heating capacity at A2/W35 1) [kW]9.32
Nominal heating capacity at A-7/W35 1) [kW]8.20
Nominal heating capacity at A-15/W35 1) [kW]6.36
COP at A12/W35/HZ 1)5.33/56
COP at A7/W35/HZ 1)4, 53/56
COP for A2/W35/HZ 1)3.53/56
COP for A-7/W35/HZ 1)2.87/56
COP for A-15/W35/HZ 1)2.40/56
Cooling capacity A35/W7 [kW/EER3)/Hz]12.20/4, 75/72
Cooling capacity A35/W18 [kW/EER3)/Hz]12.71/3.81/54
Cooling capacity A27/W18 [kW/EER3)/Hz]18.08/4.10/72
Nominal water flow rate [m³/h]2.4
Max. flow temperature of heating water [°C]55
External pressure loss [kPa]80
Heating application limits [°C]-20 to +45
Cooling application limits [°C]+15 to +45
RefrigerantR 410 A
Refrigerant quantity [kg]2.85
Air volume flow outdoor unit max. [m³/h]5400
Sound power level outdoor unit LpA 1m [dB(A)]68.3
Sound pressure level outdoor unit LpA 1m [dB(A)]42.4
Voltage supply AM [V/~/Hz]230/1/50
Nominal power consumption (A7/W35) [kW]3, 09
Nominal current consumption (A7/W35) [A]5.02
Refrigerant connections3/8‘ / 5/8’
Refrigerant line without refilling, max. length [m [m]10.0
Refrigerant line, length max. [m]75.0
Height difference refrigerant line max. [30.0
Outdoor unit dimensions (H/W/D) [mm]1430/940/330
Outdoor unit weight [kg]100
1) COP=Coefficient Of Performance according to EN 14511, TÜV tested
3) EER=Energy Efficiency Ratio according to EN 14511
The units comply with the relevant EU regulations and are CE-marked in accordance with the applicable directives. The appliances have been tested by TÜV Süd.
Technical description:
The air inlet is via the evaporator with protection against external influences by a wire grille. High-performance heat exchanger, manufactured as an evaporator from refrigerator-quality copper pipe with pressed-on aluminium fins. L-shaped with multiple injection to increase performance. Smooth-running speed-controlled axial fan with a plastic impeller, statically and dynamically balanced with horizontal contact protection grille. Weather-protected drive motor, maintenance-free and equipped with thermal overload protection. Suction gas-cooled, DC rotary piston compressor, speed-controlled via inverter. The use of neodymium magnets has increased torque and minimised friction losses. Pulse-width modulation for optimum sinusoidal characteristics. Mounted on vibration dampers for low vibration and quiet running, with high efficiency, motor protection against overcurrent and thermal overload, equipped with sound insulation as standard.
The inverter technology enables high efficiency at low outside temperatures. Protected against liquid hammer on the suction side by a generously dimensioned liquid separator. Safety chain consisting of a temperature sensor, overheating protection and overcurrent protection. All functions are monitored and controlled by a microprocessor. Microprocessor-controlled on-demand defrosting by means of a circuit reversal ensures low defrosting cycles.
Refrigeration circuit with R 410 A refrigerant with filter, receiver, 4-way changeover valve. Service/filling connections with lockable valves. Electronic expansion valve for pressure reduction installed in the outdoor unit. The refrigeration circuit is pressure-tested, leak-tested, dried, evacuated and filled with refrigerating machine oil. Refrigeration circuit pre-filled for a maximum single pipe length of 10 metres. The maximum permissible pipe length is 50 metres.
Included as standard:
Remko-Smart Control
Safety group with SIV, automatic air vent and pressure gauge
2 shut-off valves 1‘ with thermometer
Dirt filter 1’
Fill and drain tap ½”
1 external sensor
1 immersion sensor (intended for DHW heating)
Available as accessories:
Refrigerant lines
Floor or wall bracket for outdoor module
Condensate drip tray without/with oil separator
Electric condensate drain heater
Technical performance data:
Type designationREMKO WKF 180
Heating output [kW]3.1-17.7
Nominal heating output at A12/W35 1) [kW]16.02
Nominal heating output at A7/W35 1) [kW]14, 02
Nominal heating capacity at A2/W35 1) [kW]9.32
Nominal heating capacity at A-7/W35 1) [kW]8.20
Nominal heating capacity at A-15/W35 1) [kW]6.36
COP at A12/W35/HZ 1)5.33/56
COP at A7/W35/HZ 1)4, 53/56
COP for A2/W35/HZ 1)3.53/56
COP for A-7/W35/HZ 1)2.87/56
COP for A-15/W35/HZ 1)2.40/56
Cooling capacity A35/W7 [kW/EER3)/Hz]12.20/4, 75/72
Cooling capacity A35/W18 [kW/EER3)/Hz]12.71/3.81/54
Cooling capacity A27/W18 [kW/EER3)/Hz]18.08/4.10/72
Nominal water flow rate [m³/h]2.4
Max. flow temperature of heating water [°C]55
External pressure loss [kPa]80
Heating application limits [°C]-20 to +45
Cooling application limits [°C]+15 to +45
RefrigerantR 410 A
Refrigerant quantity [kg]2.85
Air volume flow outdoor unit max. [m³/h]5400
Sound power level outdoor unit LpA 1m [dB(A)]68.3
Sound pressure level outdoor unit LpA 1m [dB(A)]42.4
Voltage supply AM [V/~/Hz]230/1/50
Nominal power consumption (A7/W35) [kW]3, 09
Nominal current consumption (A7/W35) [A]5.02
Refrigerant connections3/8‘ / 5/8’
Refrigerant line without refilling, max. length [m [m]10.0
Refrigerant line, length max. [m]75.0
Height difference refrigerant line max. [30.0
Outdoor unit dimensions (H/W/D) [mm]1430/940/330
Outdoor unit weight [kg]100
1) COP=Coefficient Of Performance according to EN 14511, TÜV tested
3) EER=Energy Efficiency Ratio according to EN 14511
The units comply with the relevant EU regulations and are CE-marked in accordance with the applicable directives. The appliances have been tested by TÜV Süd.
Hinweise zur Batterieentsorgung:
Da in unseren Sendungen Batterien und Akkus enthalten sein können, sind wir nach dem Batteriegesetz (BattG) verpflichtet, Sie auf Folgendes hinzuweisen:
- Batterien und Akkus dürfen nicht im Hausmüll entsorgt werden, sondern Sie sind zur Rückgabe gebrauchter Batterien und Akkus gesetzlich verpflichtet.
- Altbatterien können Schadstoffe enthalten, die bei nicht sachgemäßer Lagerung oder Entsorgung die Umwelt oder Ihre Gesundheit schädigen können. Batterien enthalten aber auch wichtige Rohstoffe wie z.B. Eisen, Zink, Mangan oder Nickel und können verwertet werden.
- Sie können die Batterien nach Gebrauch entweder an uns zurücksenden oder in unmittelbarer Nähe (z.B. im Handel oder in kommunalen Sammelstellen oder in unserem Lager) unentgeltlich zurückgeben.
- Die Abgabe in Verkaufsstellen ist dabei für Endnutzer auf die übliche Mengen sowie solche Altbatterien beschränkt, die der Vertreiber als Neubatterien in seinem Sortiment führt oder geführt hat.
- Das Zeichen mit der durchgekreuzten Mülltonne bedeutet, dass Sie Batterien und Akkus nicht im Hausmüll entsorgen dürfen
Unter diesen Zeichen finden Sie zusätzlich nachstehende Symbole mit folgender Bedeutung:
- Pb = Batterie enthält mehr als 0,004 Masseprozent Blei
- Cd = Batterie enthält mehr als 0,002 Masseprozent Cadmium
- Hg = Batterie enthält mehr als 0,0005 Masseprozent Quecksilber
Additional information
Product group:
4101
Depth:
330mm
Width (mm):
940.0MMT
Height (mm):
1430.0MMT
Length (mm):
330.0MMT
Type:
STD
Related results
Complete catalogs
The offer is aimed exclusively at business customers, companies, public institutions, tradesmen and freelancers. All prices in catalogues are exclusive of VAT, shipping costs and surcharges if applicable.
The manufacturer is exclusively responsible for the content, price and article details of the products and offers presented in the catalogues. Subject to technical and optical changes by the manufacturer and errors excepted.
The manufacturer is exclusively responsible for the content, price and article details of the products and offers presented in the catalogues. Subject to technical and optical changes by the manufacturer and errors excepted.
Matching catalog
Commercial customer offer**
Product suggestions
-10%
Condenser board RXT 1401 DC
1111958
€76.39
-14%
ATY 267 Deco
1623430
€445.62
-19%
RK sound insulation hood SWK 4.1,
260938
€1,917.69
€2,360.00 MSRP
-13%
Oil pump AD1L2 Replacement for V1-LR2 1/4?
1108640
€159.20
-19%
RK WP Fresh water station
260182
€4,611.92
€5,680.00 MSRP
-4%
Side panel, left ATK 25
1103790
€45.50
Oil nozzle 2.25/60 degree S
1102823
€23.82
-10%
Base plate AMT 65/85-E
1105957
€118.53
-19%
Cleaning part AS-RT-D, 180-D
1085058
€705.50
€867.98 MSRP
Condensate nozzle RVD 1054 DC IT
1114438
€9.20
-13%
Oil pump VM 1
1108498
€189.03
-14%
Relay board WP-Manager (WMZ version) CMT 120/160
1120194
€297.69
-4%
Quick coupling suction line BL 263/353 DC AT
1113540
€53.49
Silencer RK 70
1104117
€7.10
Mounting plate shut-off valve RVT 263 DC AT
1112422
€15.25
No Review yet
Description: No Review yet
Written by: No Review
Rating: 5 out of 5
5 stars, based on 1
reviews
Remko WP WKF 180 AM, 3P/ 400 V Smart-WP, versatile in use 255061
REMKO GmbH & Co. KG 255061
Remko 255061
255061
4026415051334
Smart heat pumps
Inverter-controlled outdoor module for heat absorption from the ambient air. Outdoor installation. Housing and frame are made of sturdy galvanised sheet steel with additional weather-resistant polyester stove enamelling and internal sound insulation. Large removable panelling elements. Colour grey-white, similar to RAL 9002.
Technical description:
The air inlet is via the evaporator with protection against external influences by a wire grille. High-performance heat exchanger, manufactured as an evaporator from refrigerator-quality copper pipe with pressed-on aluminium fins. L-shaped with multiple injection to increase performance. Smooth-running speed-controlled axial fan with a plastic impeller, statically and dynamically balanced with horizontal contact protection grille. Weather-protected drive motor, maintenance-free and equipped with thermal overload protection. Suction gas-cooled, DC rotary piston compressor, speed-controlled via inverter. The use of neodymium magnets has increased torque and minimised friction losses. Pulse-width modulation for optimum sinusoidal characteristics. Mounted on vibration dampers for low vibration and quiet running, with high efficiency, motor protection against overcurrent and thermal overload, equipped with sound insulation as standard.
The inverter technology enables high efficiency at low outside temperatures. Protected against liquid hammer on the suction side by a generously dimensioned liquid separator. Safety chain consisting of a temperature sensor, overheating protection and overcurrent protection. All functions are monitored and controlled by a microprocessor. Microprocessor-controlled on-demand defrosting by means of a circuit reversal ensures low defrosting cycles.
Refrigeration circuit with R 410 A refrigerant with filter, receiver, 4-way changeover valve. Service/filling connections with lockable valves. Electronic expansion valve for pressure reduction installed in the outdoor unit. The refrigeration circuit is pressure-tested, leak-tested, dried, evacuated and filled with refrigerating machine oil. Refrigeration circuit pre-filled for a maximum single pipe length of 10 metres. The maximum permissible pipe length is 50 metres.
Included as standard:
Remko-Smart Control
Safety group with SIV, automatic air vent and pressure gauge
2 shut-off valves 1‘ with thermometer
Dirt filter 1’
Fill and drain tap ½”
1 external sensor
1 immersion sensor (intended for DHW heating)
Available as accessories:
Refrigerant lines
Floor or wall bracket for outdoor module
Condensate drip tray without/with oil separator
Electric condensate drain heater
Technical performance data:
Type designationREMKO WKF 180
Heating output [kW]3.1-17.7
Nominal heating output at A12/W35 1) [kW]16.02
Nominal heating output at A7/W35 1) [kW]14, 02
Nominal heating capacity at A2/W35 1) [kW]9.32
Nominal heating capacity at A-7/W35 1) [kW]8.20
Nominal heating capacity at A-15/W35 1) [kW]6.36
COP at A12/W35/HZ 1)5.33/56
COP at A7/W35/HZ 1)4, 53/56
COP for A2/W35/HZ 1)3.53/56
COP for A-7/W35/HZ 1)2.87/56
COP for A-15/W35/HZ 1)2.40/56
Cooling capacity A35/W7 [kW/EER3)/Hz]12.20/4, 75/72
Cooling capacity A35/W18 [kW/EER3)/Hz]12.71/3.81/54
Cooling capacity A27/W18 [kW/EER3)/Hz]18.08/4.10/72
Nominal water flow rate [m³/h]2.4
Max. flow temperature of heating water [°C]55
External pressure loss [kPa]80
Heating application limits [°C]-20 to +45
Cooling application limits [°C]+15 to +45
RefrigerantR 410 A
Refrigerant quantity [kg]2.85
Air volume flow outdoor unit max. [m³/h]5400
Sound power level outdoor unit LpA 1m [dB(A)]68.3
Sound pressure level outdoor unit LpA 1m [dB(A)]42.4
Voltage supply AM [V/~/Hz]230/1/50
Nominal power consumption (A7/W35) [kW]3, 09
Nominal current consumption (A7/W35) [A]5.02
Refrigerant connections3/8‘ / 5/8’
Refrigerant line without refilling, max. length [m [m]10.0
Refrigerant line, length max. [m]75.0
Height difference refrigerant line max. [30.0
Outdoor unit dimensions (H/W/D) [mm]1430/940/330
Outdoor unit weight [kg]100
1) COP=Coefficient Of Performance according to EN 14511, TÜV tested
3) EER=Energy Efficiency Ratio according to EN 14511
The units comply with the relevant EU regulations and are CE-marked in accordance with the applicable directives. The appliances have been tested by TÜV Süd. T-385080 255061 4026415051334 en ["de","en","it","nl","nl","fr","es","pl","pt","cs","da","sv"] https://www.toolteam.com/en-GB/remko-wp-wkf-180-am-3p-400-v-smart-wp-versatile-in-use-255061-t-385080-4026415051334?dc=GB&cu=EUR 2026-08-03 4587.56 United Kingdom GB DE 14
Technical description:
The air inlet is via the evaporator with protection against external influences by a wire grille. High-performance heat exchanger, manufactured as an evaporator from refrigerator-quality copper pipe with pressed-on aluminium fins. L-shaped with multiple injection to increase performance. Smooth-running speed-controlled axial fan with a plastic impeller, statically and dynamically balanced with horizontal contact protection grille. Weather-protected drive motor, maintenance-free and equipped with thermal overload protection. Suction gas-cooled, DC rotary piston compressor, speed-controlled via inverter. The use of neodymium magnets has increased torque and minimised friction losses. Pulse-width modulation for optimum sinusoidal characteristics. Mounted on vibration dampers for low vibration and quiet running, with high efficiency, motor protection against overcurrent and thermal overload, equipped with sound insulation as standard.
The inverter technology enables high efficiency at low outside temperatures. Protected against liquid hammer on the suction side by a generously dimensioned liquid separator. Safety chain consisting of a temperature sensor, overheating protection and overcurrent protection. All functions are monitored and controlled by a microprocessor. Microprocessor-controlled on-demand defrosting by means of a circuit reversal ensures low defrosting cycles.
Refrigeration circuit with R 410 A refrigerant with filter, receiver, 4-way changeover valve. Service/filling connections with lockable valves. Electronic expansion valve for pressure reduction installed in the outdoor unit. The refrigeration circuit is pressure-tested, leak-tested, dried, evacuated and filled with refrigerating machine oil. Refrigeration circuit pre-filled for a maximum single pipe length of 10 metres. The maximum permissible pipe length is 50 metres.
Included as standard:
Remko-Smart Control
Safety group with SIV, automatic air vent and pressure gauge
2 shut-off valves 1‘ with thermometer
Dirt filter 1’
Fill and drain tap ½”
1 external sensor
1 immersion sensor (intended for DHW heating)
Available as accessories:
Refrigerant lines
Floor or wall bracket for outdoor module
Condensate drip tray without/with oil separator
Electric condensate drain heater
Technical performance data:
Type designationREMKO WKF 180
Heating output [kW]3.1-17.7
Nominal heating output at A12/W35 1) [kW]16.02
Nominal heating output at A7/W35 1) [kW]14, 02
Nominal heating capacity at A2/W35 1) [kW]9.32
Nominal heating capacity at A-7/W35 1) [kW]8.20
Nominal heating capacity at A-15/W35 1) [kW]6.36
COP at A12/W35/HZ 1)5.33/56
COP at A7/W35/HZ 1)4, 53/56
COP for A2/W35/HZ 1)3.53/56
COP for A-7/W35/HZ 1)2.87/56
COP for A-15/W35/HZ 1)2.40/56
Cooling capacity A35/W7 [kW/EER3)/Hz]12.20/4, 75/72
Cooling capacity A35/W18 [kW/EER3)/Hz]12.71/3.81/54
Cooling capacity A27/W18 [kW/EER3)/Hz]18.08/4.10/72
Nominal water flow rate [m³/h]2.4
Max. flow temperature of heating water [°C]55
External pressure loss [kPa]80
Heating application limits [°C]-20 to +45
Cooling application limits [°C]+15 to +45
RefrigerantR 410 A
Refrigerant quantity [kg]2.85
Air volume flow outdoor unit max. [m³/h]5400
Sound power level outdoor unit LpA 1m [dB(A)]68.3
Sound pressure level outdoor unit LpA 1m [dB(A)]42.4
Voltage supply AM [V/~/Hz]230/1/50
Nominal power consumption (A7/W35) [kW]3, 09
Nominal current consumption (A7/W35) [A]5.02
Refrigerant connections3/8‘ / 5/8’
Refrigerant line without refilling, max. length [m [m]10.0
Refrigerant line, length max. [m]75.0
Height difference refrigerant line max. [30.0
Outdoor unit dimensions (H/W/D) [mm]1430/940/330
Outdoor unit weight [kg]100
1) COP=Coefficient Of Performance according to EN 14511, TÜV tested
3) EER=Energy Efficiency Ratio according to EN 14511
The units comply with the relevant EU regulations and are CE-marked in accordance with the applicable directives. The appliances have been tested by TÜV Süd. T-385080 255061 4026415051334 en ["de","en","it","nl","nl","fr","es","pl","pt","cs","da","sv"] https://www.toolteam.com/en-GB/remko-wp-wkf-180-am-3p-400-v-smart-wp-versatile-in-use-255061-t-385080-4026415051334?dc=GB&cu=EUR 2026-08-03 4587.56 United Kingdom GB DE 14