zoom_in
zoom_out
fullscreen
Remko WP WKF 120 IM Smart-WP, versatile in use 255052
Sku: T-385076
Discontinued item
Product variants
| Sku: | Name: | SKU manufacturer: | ||
|---|---|---|---|---|
|
T-385043 | WP WKF 70 IM Smart-WP, versatile in use | 254011 | |
|
T-385081 | WP WKF 180 IM Smart-WP, versatile in use | 255062 |
doneREMKO Smart-WP
doneMade in Germany
Remko WP WKF 120 IM Smart-WP 255052, versatile application
Product data
Manufacturer:
REMKO GmbH & Co. KG
Condition:
NEW
Sku:
T-385076
SKU manufacturer:
255052
GTIN Code (EAN):
4026415049638
Weight:
43,00 Kg
All information relating to products from REMKO GmbH & Co. KG. Technical and optical modifications of the manufacturer and errors reserved.
This page has been machine-translated, the original german version can be found here, please also note the Translation Disclaimer.
Product description
Housing in an attractive design made of EPP plastic in combination with a silver-painted sheet steel front (RAL 9006) with full-surface designer font and integrated Smart Control for regulating the heating system and energy management.
Technical description: Basic equipment
Device mounted on the wall using the wall bracket supplied. Speed-controlled Wilo circulation pump for heating water circulation and high-performance plate heat exchanger (condenser) for heat transfer are installed. A flow sensor to ensure the minimum flow rate, flow and return sensors and a manual air vent are integrated. The switch box is prepared for the electrical connection of two heating circuits and a solar thermal system. The three-way changeover valve for domestic hot water preparation is already installed. All hydraulic pipe connections and refrigerant connections are led out at the top. The supplied safety assembly is mounted on the top on a pipe socket provided for this purpose. Effective comfort air conditioning is realised by reversing the refrigerant circuit. A flow temperature between +7°C and +25°C can be selected in cooling mode. The three-way valve, available as an accessory, activates a separate hydraulic circuit with corresponding cooling insulation. For surface cooling, a separate Smart Control control panel can be used as a remote control in the living area for dew point monitoring. An electronically controlled bypass mixer is integrated to ensure the minimum volume flow. A 9 kW heating element (Smart-Serv) can be optionally installed in the indoor module for monoenergetic operation and emergency operation. The Smart BVT accessory set is available for connection to the indoor module of a boiler (gas/oil) with a separate pump for bivalent alternative operation. However, a buffer is then required as a hydraulic separator.
Included as standard:
Remko-Smart Control
Safety group with SIV, automatic air vent and pressure gauge
2 shut-off valves 1‘ with thermometer
Dirt filter 1’
Fill and drain tap ½”
1 external sensor
1 immersion sensor (intended for DHW heating)
Available as accessories:
Refrigerant pipes
Overflow valve 1”
Contact and immersion sensors for integrating additional system components
Storage systems
Smart Control cable remote control
Smart-Count (heat meter)
Smart-BVT (bivalent alternative operation)
Smart-Serv (9 kW elect. Additional heating)
3-way changeover valve for domestic hot water preparation
Highly efficient heating circuit pump groups unregulated/regulated
REMKO Smart Control
The intuitive controller software with plain text menu and commissioning wizard makes installation, maintenance and integration of additional modules easier for the installer. Control with integrated microprocessor control for weather-compensated flow temperature control in heating mode in full text display and animation. Domestic hot water priority switching in heating mode. The Remko Smart Control has a particularly energy-saving control system thanks to the use of a single high-efficiency circulation pump or for a direct heating circuit (radiators) including heating circuit pump control and a mixed heating circuit (underfloor heating) including heating circuit pump control and mixer valve control. Solar control including circulation pump switching via temperature difference measurement is also possible. The supplied micro SD card stores the temperature curves and other data. Colour display with energy balances, diagrams and animations. Continuous function monitoring Summer mode, heating mode, standby (frost protection), power supply shutdown, screed drying programme, time programmes with different setpoint settings. Commissioning wizard, legionella control. Fault display with suggestions for troubleshooting Own power consumption optimised controlling of the PV system via S0 interface.
Technical performance data:
Type designationREMKO WKF 120
Heating output [kW]2.5-12.5
Nominal heating output at A12/W35 1) [kW]10.96
Nominal heating output at A7/W35 1) [kW]9, 86
Nominal heating capacity at A2/W35 1) [kW]6.95
Nominal heating capacity at A-7/W35 1) [kW]6.14
Nominal heating capacity at A-15/W35 1) [kW]4, 82
COP at A12/W35/HZ 1)4.82/61
COP at A7/W35/HZ 1)4.44/61
COP at A2/W35/HZ 1)3.64/60
COP at A-7/W35/HZ 1)2, 89/61
COP for A-15/W35/HZ 1)2.39/61
Cooling capacity A35/W7 [kW/EER3)/Hz]6.77/2.31/66
Cooling capacity A35/W18 [kW/EER3)/Hz]5, 3/3.65/38
Cooling capacity A27/W18 [kW/EER3)/Hz]9.46/3.60/38
Nominal water volume flow [m³/h]1.70
BEVB WKT 300 [kWh/day]1, 46
External pressure loss [kPa]80
Application limits heating [°C]-20 to +45
Application limits cooling [°C]+15 to +45
RefrigerantR 410 A
Refrigerant quantity [kg]2, 00
Voltage supply IM [V/~/Hz]230/1/50
Nominal power consumption (A7/W35) [kW]2.22
Nominal current consumption (A7/W35) [A]10.44
Refrigerant connections3/8‘ / 5/8’
Refrigerant line without refilling, length max. [m]10.0
Refrigerant line, length max. [m]50.0
Height difference refrigerant line max. [30.0
Dimensions indoor module (H/W/D) [mm]500/800/500
Weight indoor module [kg]43
1) COP=Coefficient Of Performance (coefficient of performance) according to EN 14511, TÜV tested
3) EER=Energy Efficiency Ratio (coefficient of performance) according to EN 14511
The appliances comply with the relevant EU regulations and are CE-labelled in accordance with the applicable directives. The appliances have been tested by TÜV Süd.
Technical description: Basic equipment
Device mounted on the wall using the wall bracket supplied. Speed-controlled Wilo circulation pump for heating water circulation and high-performance plate heat exchanger (condenser) for heat transfer are installed. A flow sensor to ensure the minimum flow rate, flow and return sensors and a manual air vent are integrated. The switch box is prepared for the electrical connection of two heating circuits and a solar thermal system. The three-way changeover valve for domestic hot water preparation is already installed. All hydraulic pipe connections and refrigerant connections are led out at the top. The supplied safety assembly is mounted on the top on a pipe socket provided for this purpose. Effective comfort air conditioning is realised by reversing the refrigerant circuit. A flow temperature between +7°C and +25°C can be selected in cooling mode. The three-way valve, available as an accessory, activates a separate hydraulic circuit with corresponding cooling insulation. For surface cooling, a separate Smart Control control panel can be used as a remote control in the living area for dew point monitoring. An electronically controlled bypass mixer is integrated to ensure the minimum volume flow. A 9 kW heating element (Smart-Serv) can be optionally installed in the indoor module for monoenergetic operation and emergency operation. The Smart BVT accessory set is available for connection to the indoor module of a boiler (gas/oil) with a separate pump for bivalent alternative operation. However, a buffer is then required as a hydraulic separator.
Included as standard:
Remko-Smart Control
Safety group with SIV, automatic air vent and pressure gauge
2 shut-off valves 1‘ with thermometer
Dirt filter 1’
Fill and drain tap ½”
1 external sensor
1 immersion sensor (intended for DHW heating)
Available as accessories:
Refrigerant pipes
Overflow valve 1”
Contact and immersion sensors for integrating additional system components
Storage systems
Smart Control cable remote control
Smart-Count (heat meter)
Smart-BVT (bivalent alternative operation)
Smart-Serv (9 kW elect. Additional heating)
3-way changeover valve for domestic hot water preparation
Highly efficient heating circuit pump groups unregulated/regulated
REMKO Smart Control
The intuitive controller software with plain text menu and commissioning wizard makes installation, maintenance and integration of additional modules easier for the installer. Control with integrated microprocessor control for weather-compensated flow temperature control in heating mode in full text display and animation. Domestic hot water priority switching in heating mode. The Remko Smart Control has a particularly energy-saving control system thanks to the use of a single high-efficiency circulation pump or for a direct heating circuit (radiators) including heating circuit pump control and a mixed heating circuit (underfloor heating) including heating circuit pump control and mixer valve control. Solar control including circulation pump switching via temperature difference measurement is also possible. The supplied micro SD card stores the temperature curves and other data. Colour display with energy balances, diagrams and animations. Continuous function monitoring Summer mode, heating mode, standby (frost protection), power supply shutdown, screed drying programme, time programmes with different setpoint settings. Commissioning wizard, legionella control. Fault display with suggestions for troubleshooting Own power consumption optimised controlling of the PV system via S0 interface.
Technical performance data:
Type designationREMKO WKF 120
Heating output [kW]2.5-12.5
Nominal heating output at A12/W35 1) [kW]10.96
Nominal heating output at A7/W35 1) [kW]9, 86
Nominal heating capacity at A2/W35 1) [kW]6.95
Nominal heating capacity at A-7/W35 1) [kW]6.14
Nominal heating capacity at A-15/W35 1) [kW]4, 82
COP at A12/W35/HZ 1)4.82/61
COP at A7/W35/HZ 1)4.44/61
COP at A2/W35/HZ 1)3.64/60
COP at A-7/W35/HZ 1)2, 89/61
COP for A-15/W35/HZ 1)2.39/61
Cooling capacity A35/W7 [kW/EER3)/Hz]6.77/2.31/66
Cooling capacity A35/W18 [kW/EER3)/Hz]5, 3/3.65/38
Cooling capacity A27/W18 [kW/EER3)/Hz]9.46/3.60/38
Nominal water volume flow [m³/h]1.70
BEVB WKT 300 [kWh/day]1, 46
External pressure loss [kPa]80
Application limits heating [°C]-20 to +45
Application limits cooling [°C]+15 to +45
RefrigerantR 410 A
Refrigerant quantity [kg]2, 00
Voltage supply IM [V/~/Hz]230/1/50
Nominal power consumption (A7/W35) [kW]2.22
Nominal current consumption (A7/W35) [A]10.44
Refrigerant connections3/8‘ / 5/8’
Refrigerant line without refilling, length max. [m]10.0
Refrigerant line, length max. [m]50.0
Height difference refrigerant line max. [30.0
Dimensions indoor module (H/W/D) [mm]500/800/500
Weight indoor module [kg]43
1) COP=Coefficient Of Performance (coefficient of performance) according to EN 14511, TÜV tested
3) EER=Energy Efficiency Ratio (coefficient of performance) according to EN 14511
The appliances comply with the relevant EU regulations and are CE-labelled in accordance with the applicable directives. The appliances have been tested by TÜV Süd.
Additional information
Product group:
4101
Depth:
790mm
Width (mm):
800.0MMT
Height (mm):
1928.0MMT
Length (mm):
790.0MMT
Type:
STD
Related results
Complete catalogs
The offer is aimed exclusively at business customers, companies, public institutions, tradesmen and freelancers. All prices in catalogues are exclusive of VAT, shipping costs and surcharges if applicable.
The manufacturer is exclusively responsible for the content, price and article details of the products and offers presented in the catalogues. Subject to technical and optical changes by the manufacturer and errors excepted.
The manufacturer is exclusively responsible for the content, price and article details of the products and offers presented in the catalogues. Subject to technical and optical changes by the manufacturer and errors excepted.
Matching catalog
Commercial customer offer**
Product suggestions
Whirler WKL/VRS 50-60
1102954
€22.14
-19%
ATY 357 Deco IT Arctic
1624572
€552.14
€680.00 MSRP
Relay Board Merlin CMF/CMT-New version
1120030-N
€396.93
-19%
RK WP Fresh water station
260180
€1,830.67
€2,252.98 MSRP
-13%
Pressure regulator 1.5 bar/10 kg
1101663
€186.60
-14%
Outer casing INOX ELT 10-HT
1101511
€286.85
-13%
Oil pump VM 1
1108498
€189.03
-4%
Quick coupling suction line BL 263/353 DC AT
1113540
€53.49
-10%
Base plate AMT 65/85-E
1105957
€118.53
Condensate nozzle RVD 684/MVD 701-1001
1114421
€9.20
-13%
Condensate drip tray KWK 450/600 (ZW)
1111783
€169.33
-4%
Support ring, 1-piece RK 25-50
1104168
€43.87
-4%
Condensate container ETF/AMT
1104429
€61.09
Accessory pack 1
1106445
€21.67
Oil nozzle 2.25/60 degree S
1102823
€23.82
No Review yet
Description: No Review yet
Written by: No Review
Rating: 5 out of 5
5 stars, based on 1
reviews
Remko WP WKF 120 IM Smart-WP, versatile in use 255052
REMKO GmbH & Co. KG 255052
Remko 255052
255052
4026415049638
Smart heat pumps
Housing in an attractive design made of EPP plastic in combination with a silver-painted sheet steel front (RAL 9006) with full-surface designer font and integrated Smart Control for regulating the heating system and energy management.
Technical description: Basic equipment
Device mounted on the wall using the wall bracket supplied. Speed-controlled Wilo circulation pump for heating water circulation and high-performance plate heat exchanger (condenser) for heat transfer are installed. A flow sensor to ensure the minimum flow rate, flow and return sensors and a manual air vent are integrated. The switch box is prepared for the electrical connection of two heating circuits and a solar thermal system. The three-way changeover valve for domestic hot water preparation is already installed. All hydraulic pipe connections and refrigerant connections are led out at the top. The supplied safety assembly is mounted on the top on a pipe socket provided for this purpose. Effective comfort air conditioning is realised by reversing the refrigerant circuit. A flow temperature between +7°C and +25°C can be selected in cooling mode. The three-way valve, available as an accessory, activates a separate hydraulic circuit with corresponding cooling insulation. For surface cooling, a separate Smart Control control panel can be used as a remote control in the living area for dew point monitoring. An electronically controlled bypass mixer is integrated to ensure the minimum volume flow. A 9 kW heating element (Smart-Serv) can be optionally installed in the indoor module for monoenergetic operation and emergency operation. The Smart BVT accessory set is available for connection to the indoor module of a boiler (gas/oil) with a separate pump for bivalent alternative operation. However, a buffer is then required as a hydraulic separator.
Included as standard:
Remko-Smart Control
Safety group with SIV, automatic air vent and pressure gauge
2 shut-off valves 1‘ with thermometer
Dirt filter 1’
Fill and drain tap ½”
1 external sensor
1 immersion sensor (intended for DHW heating)
Available as accessories:
Refrigerant pipes
Overflow valve 1”
Contact and immersion sensors for integrating additional system components
Storage systems
Smart Control cable remote control
Smart-Count (heat meter)
Smart-BVT (bivalent alternative operation)
Smart-Serv (9 kW elect. Additional heating)
3-way changeover valve for domestic hot water preparation
Highly efficient heating circuit pump groups unregulated/regulated
REMKO Smart Control
The intuitive controller software with plain text menu and commissioning wizard makes installation, maintenance and integration of additional modules easier for the installer. Control with integrated microprocessor control for weather-compensated flow temperature control in heating mode in full text display and animation. Domestic hot water priority switching in heating mode. The Remko Smart Control has a particularly energy-saving control system thanks to the use of a single high-efficiency circulation pump or for a direct heating circuit (radiators) including heating circuit pump control and a mixed heating circuit (underfloor heating) including heating circuit pump control and mixer valve control. Solar control including circulation pump switching via temperature difference measurement is also possible. The supplied micro SD card stores the temperature curves and other data. Colour display with energy balances, diagrams and animations. Continuous function monitoring Summer mode, heating mode, standby (frost protection), power supply shutdown, screed drying programme, time programmes with different setpoint settings. Commissioning wizard, legionella control. Fault display with suggestions for troubleshooting Own power consumption optimised controlling of the PV system via S0 interface.
Technical performance data:
Type designationREMKO WKF 120
Heating output [kW]2.5-12.5
Nominal heating output at A12/W35 1) [kW]10.96
Nominal heating output at A7/W35 1) [kW]9, 86
Nominal heating capacity at A2/W35 1) [kW]6.95
Nominal heating capacity at A-7/W35 1) [kW]6.14
Nominal heating capacity at A-15/W35 1) [kW]4, 82
COP at A12/W35/HZ 1)4.82/61
COP at A7/W35/HZ 1)4.44/61
COP at A2/W35/HZ 1)3.64/60
COP at A-7/W35/HZ 1)2, 89/61
COP for A-15/W35/HZ 1)2.39/61
Cooling capacity A35/W7 [kW/EER3)/Hz]6.77/2.31/66
Cooling capacity A35/W18 [kW/EER3)/Hz]5, 3/3.65/38
Cooling capacity A27/W18 [kW/EER3)/Hz]9.46/3.60/38
Nominal water volume flow [m³/h]1.70
BEVB WKT 300 [kWh/day]1, 46
External pressure loss [kPa]80
Application limits heating [°C]-20 to +45
Application limits cooling [°C]+15 to +45
RefrigerantR 410 A
Refrigerant quantity [kg]2, 00
Voltage supply IM [V/~/Hz]230/1/50
Nominal power consumption (A7/W35) [kW]2.22
Nominal current consumption (A7/W35) [A]10.44
Refrigerant connections3/8‘ / 5/8’
Refrigerant line without refilling, length max. [m]10.0
Refrigerant line, length max. [m]50.0
Height difference refrigerant line max. [30.0
Dimensions indoor module (H/W/D) [mm]500/800/500
Weight indoor module [kg]43
1) COP=Coefficient Of Performance (coefficient of performance) according to EN 14511, TÜV tested
3) EER=Energy Efficiency Ratio (coefficient of performance) according to EN 14511
The appliances comply with the relevant EU regulations and are CE-labelled in accordance with the applicable directives. The appliances have been tested by TÜV Süd. T-385076 255052 4026415049638 en ["de","en","it","nl","nl","fr","es","pl","pt","cs","da","sv"] https://www.toolteam.com/en-GB/remko-wp-wkf-120-im-smart-wp-versatile-in-use-255052-t-385076-4026415049638?dc=GB&cu=EUR 2026-07-14 3461.39 United Kingdom GB DE 14
Technical description: Basic equipment
Device mounted on the wall using the wall bracket supplied. Speed-controlled Wilo circulation pump for heating water circulation and high-performance plate heat exchanger (condenser) for heat transfer are installed. A flow sensor to ensure the minimum flow rate, flow and return sensors and a manual air vent are integrated. The switch box is prepared for the electrical connection of two heating circuits and a solar thermal system. The three-way changeover valve for domestic hot water preparation is already installed. All hydraulic pipe connections and refrigerant connections are led out at the top. The supplied safety assembly is mounted on the top on a pipe socket provided for this purpose. Effective comfort air conditioning is realised by reversing the refrigerant circuit. A flow temperature between +7°C and +25°C can be selected in cooling mode. The three-way valve, available as an accessory, activates a separate hydraulic circuit with corresponding cooling insulation. For surface cooling, a separate Smart Control control panel can be used as a remote control in the living area for dew point monitoring. An electronically controlled bypass mixer is integrated to ensure the minimum volume flow. A 9 kW heating element (Smart-Serv) can be optionally installed in the indoor module for monoenergetic operation and emergency operation. The Smart BVT accessory set is available for connection to the indoor module of a boiler (gas/oil) with a separate pump for bivalent alternative operation. However, a buffer is then required as a hydraulic separator.
Included as standard:
Remko-Smart Control
Safety group with SIV, automatic air vent and pressure gauge
2 shut-off valves 1‘ with thermometer
Dirt filter 1’
Fill and drain tap ½”
1 external sensor
1 immersion sensor (intended for DHW heating)
Available as accessories:
Refrigerant pipes
Overflow valve 1”
Contact and immersion sensors for integrating additional system components
Storage systems
Smart Control cable remote control
Smart-Count (heat meter)
Smart-BVT (bivalent alternative operation)
Smart-Serv (9 kW elect. Additional heating)
3-way changeover valve for domestic hot water preparation
Highly efficient heating circuit pump groups unregulated/regulated
REMKO Smart Control
The intuitive controller software with plain text menu and commissioning wizard makes installation, maintenance and integration of additional modules easier for the installer. Control with integrated microprocessor control for weather-compensated flow temperature control in heating mode in full text display and animation. Domestic hot water priority switching in heating mode. The Remko Smart Control has a particularly energy-saving control system thanks to the use of a single high-efficiency circulation pump or for a direct heating circuit (radiators) including heating circuit pump control and a mixed heating circuit (underfloor heating) including heating circuit pump control and mixer valve control. Solar control including circulation pump switching via temperature difference measurement is also possible. The supplied micro SD card stores the temperature curves and other data. Colour display with energy balances, diagrams and animations. Continuous function monitoring Summer mode, heating mode, standby (frost protection), power supply shutdown, screed drying programme, time programmes with different setpoint settings. Commissioning wizard, legionella control. Fault display with suggestions for troubleshooting Own power consumption optimised controlling of the PV system via S0 interface.
Technical performance data:
Type designationREMKO WKF 120
Heating output [kW]2.5-12.5
Nominal heating output at A12/W35 1) [kW]10.96
Nominal heating output at A7/W35 1) [kW]9, 86
Nominal heating capacity at A2/W35 1) [kW]6.95
Nominal heating capacity at A-7/W35 1) [kW]6.14
Nominal heating capacity at A-15/W35 1) [kW]4, 82
COP at A12/W35/HZ 1)4.82/61
COP at A7/W35/HZ 1)4.44/61
COP at A2/W35/HZ 1)3.64/60
COP at A-7/W35/HZ 1)2, 89/61
COP for A-15/W35/HZ 1)2.39/61
Cooling capacity A35/W7 [kW/EER3)/Hz]6.77/2.31/66
Cooling capacity A35/W18 [kW/EER3)/Hz]5, 3/3.65/38
Cooling capacity A27/W18 [kW/EER3)/Hz]9.46/3.60/38
Nominal water volume flow [m³/h]1.70
BEVB WKT 300 [kWh/day]1, 46
External pressure loss [kPa]80
Application limits heating [°C]-20 to +45
Application limits cooling [°C]+15 to +45
RefrigerantR 410 A
Refrigerant quantity [kg]2, 00
Voltage supply IM [V/~/Hz]230/1/50
Nominal power consumption (A7/W35) [kW]2.22
Nominal current consumption (A7/W35) [A]10.44
Refrigerant connections3/8‘ / 5/8’
Refrigerant line without refilling, length max. [m]10.0
Refrigerant line, length max. [m]50.0
Height difference refrigerant line max. [30.0
Dimensions indoor module (H/W/D) [mm]500/800/500
Weight indoor module [kg]43
1) COP=Coefficient Of Performance (coefficient of performance) according to EN 14511, TÜV tested
3) EER=Energy Efficiency Ratio (coefficient of performance) according to EN 14511
The appliances comply with the relevant EU regulations and are CE-labelled in accordance with the applicable directives. The appliances have been tested by TÜV Süd. T-385076 255052 4026415049638 en ["de","en","it","nl","nl","fr","es","pl","pt","cs","da","sv"] https://www.toolteam.com/en-GB/remko-wp-wkf-120-im-smart-wp-versatile-in-use-255052-t-385076-4026415049638?dc=GB&cu=EUR 2026-07-14 3461.39 United Kingdom GB DE 14