zoom_in
zoom_out
fullscreen
-19%
Remko WP L/W Monobloc heat pump LWM 80 ALU 262081
Sku: T-385475
€10,328.15 (excl. legal VAT, excl. Shipping)
€12,720.00 MSRP
In stock,ready for shipping within 24h
Package
Product variants
| Sku: | Name: | SKU manufacturer: | ||
|---|---|---|---|---|
|
T-385473 | WP L/W Monobloc heat pump LWM 80 ALU | 262080 | |
|
T-385481 | WP L/W Monobloc heat pump LWM 110 ALU | 262110 | |
|
T-385483 | WP L/W Monobloc heat pump LWM 110 ALU | 262111 | |
|
T-385485 | WP L/W Monobloc heat pump LWM 110 CAMURA | 262113 | |
|
T-385487 | WP L/W Monobloc heat pump LWM 110 GRAPHIT | 262115 | |
|
T-385488 | WP L/W Monobloc heat pump LWM 150 ALU | 262150 | |
|
T-385490 | WP L/W Monobloc heat pump LWM 150 ALU | 262151 | |
|
T-385492 | WP L/W Monobloc heat pump LWM 150 CAMURA | 262153 | |
|
T-385494 | WP L/W Monobloc heat pump LWM 150 GRAPHIT | 262155 |
doneL/W monoblock heat pump
Remko WP L/W Monoblock heat pump LWM 80 ALU 262081
Content:
1 Package
Shipping:
€526.81 Versandservice to United Kingdom
For orders from €1,000.00 order total plus €34.45 Customs MRN registration
Lieferung:
Provider:
Sales and delivery by ToolTeam Köln
Payment methods:
Returns:
Security:
Product data
Manufacturer:
REMKO GmbH & Co. KG
Condition:
NEW
Sku:
T-385475
SKU manufacturer:
262081
GTIN Code (EAN):
4026415149833
Weight:
199,70 Kg
All information relating to products from REMKO GmbH & Co. KG. Technical and optical modifications of the manufacturer and errors reserved.
This page has been machine-translated, the original german version can be found here, please also note the Translation Disclaimer.
Product description
Air/water monobloc heat pump for heating/cooling and hot water operation. Housing in an attractive design in combination with sound insulation and a silver-painted sheet steel front (RAL 9006). Air guide fins in aluminium silver (RAL 9006), Designline aluminium. Fully hermetic refrigerant circuit with LOW-GWP refrigerant R 454B, with filter, receiver, scroll compressor and electronic expansion valve. High-efficiency controlled heating circuit pump, plate heat exchanger and electrical flow monitor. Microprocessor-controlled heat output regulation by means of an externally installed Smart Control.
REMKO Smart-Control Touch
All functions of the heat pump and the heating circuits can be set using the Smart Control touch display. The intuitive controller software with plain text menu and commissioning wizard makes installation, maintenance and integration of additional modules easier for the installer.
Control of one unmixed and two mixed heating circuits (floor or radiators) with different flow temperatures, DHW preparation and temperature control can be realised. Depending on the system version, the required I/O module is supplied in the indoor module with an enamelled DHW cylinder (300L) or in an attractive surface-mounted housing with cable entries. The 4.3’ touch display with WLAN function is supplied in a separate surface-mounted housing and can also be installed flexibly in other rooms. Dew point control is possible via a separately installed humidity/temperature sensor. This is required for temperature control, e.g. cooling via a floor circuit. We recommend installing an additional dew point monitor (Remko EDP no. 259070) when temperature control is activated via panel heating systems.
Included as standard:
Safety group with SIV, automatic air vent and pressure gauge for heating circuit
2 shut-off valves 1‘ for heating circuits
1 dirt filter 1’ for heating circuits
1 outdoor sensor,
1 immersion sensor (intended for DHW heating)
Available as accessories:
Electr. Overflow valve 1”
Sludge separator
Air separator
Heat transfer medium with frost protection
Contact and immersion sensors for integrating additional system components
Storage systems
Smart Control cable remote control
Smart-Count (heat meter)
Smart-Serv (7.5 kW electric auxiliary heating incl. emergency heating operation)
Smart-Web (emergency heating operation). emergency heating operation)
Smart-Web (Internet access)
3-way changeover valve for domestic hot water preparation
Highly efficient heating circuit pump groups with/without mixer
Technical performance data:
Type designationREMKO LWM 80
Application range heating incl. DHW [kW] 1-7
Application limit heating [°C] -23 to +35
Heating output according to ErP 35/55°C[kW]5.0/5, 0
Efficiency class (heating)A++/A++
Annual energy consumption 35/55°C [kWh]2629/3173
Space heating energy efficiency eta s161/136
Nominal heating output at A7/W35 1) [kW]6, 25
Nominal heating capacity at A2/W35 1) [kW]4.33
Nominal heating capacity at A-7/W35 1) [kW]3.82
COP at A7/W35° 1) 5.10
COP at A2/W35° 1) 4, 09
COP at A-7/W35° 1) 3.55
Cooling capacity /W7 KW/EER 2)4.90
Nominal heating volume flow [m³/h]1.1
Flow temperature heating water max. [°C]65
Max. Max. pressure loss heating system [kPa]60
Refrigerant/base charge [-/kg]R 454B / 1.1
GWP value 466
CO² equivalent [t] 0.51
Voltage supply comp. IM [V/~/Hz]230V/1~/50
Power supply Smart Control IM [V/~/Hz]230/1/50
Power supply E-heating element IM [V/~/Hz] 400V/3~/50
Nominal power consumption (A7/W35) [kW]1.22
Nominal current consumption (A7/W35) [A]3, 05
Sound power level AM LpA nominal [dB(A)]56
Sound pressure level nominal AM LpA [dB(A)] 3)33
Sound power level AM LpA night [dB(A)]54
Sound pressure level AM night LpA [dB(A)] 3)30
Dimensions AM HxWxD [mm]1600x1000x800
Outer module weight [kg]180, 00
1) COP = Coefficient Of Performance according to EN 14511, VDE tested
2) EER=Energy Efficiency Ratio according to EN 14511
3) with semi-formal dispersion at 6m, A7/W55 measurement according to DIN EN 12102 and DIN EN ISO 9614-2
The devices comply with the relevant EU regulations and are CE-marked in accordance with the applicable directives.
REMKO Smart-Control Touch
All functions of the heat pump and the heating circuits can be set using the Smart Control touch display. The intuitive controller software with plain text menu and commissioning wizard makes installation, maintenance and integration of additional modules easier for the installer.
Control of one unmixed and two mixed heating circuits (floor or radiators) with different flow temperatures, DHW preparation and temperature control can be realised. Depending on the system version, the required I/O module is supplied in the indoor module with an enamelled DHW cylinder (300L) or in an attractive surface-mounted housing with cable entries. The 4.3’ touch display with WLAN function is supplied in a separate surface-mounted housing and can also be installed flexibly in other rooms. Dew point control is possible via a separately installed humidity/temperature sensor. This is required for temperature control, e.g. cooling via a floor circuit. We recommend installing an additional dew point monitor (Remko EDP no. 259070) when temperature control is activated via panel heating systems.
Included as standard:
Safety group with SIV, automatic air vent and pressure gauge for heating circuit
2 shut-off valves 1‘ for heating circuits
1 dirt filter 1’ for heating circuits
1 outdoor sensor,
1 immersion sensor (intended for DHW heating)
Available as accessories:
Electr. Overflow valve 1”
Sludge separator
Air separator
Heat transfer medium with frost protection
Contact and immersion sensors for integrating additional system components
Storage systems
Smart Control cable remote control
Smart-Count (heat meter)
Smart-Serv (7.5 kW electric auxiliary heating incl. emergency heating operation)
Smart-Web (emergency heating operation). emergency heating operation)
Smart-Web (Internet access)
3-way changeover valve for domestic hot water preparation
Highly efficient heating circuit pump groups with/without mixer
Technical performance data:
Type designationREMKO LWM 80
Application range heating incl. DHW [kW] 1-7
Application limit heating [°C] -23 to +35
Heating output according to ErP 35/55°C[kW]5.0/5, 0
Efficiency class (heating)A++/A++
Annual energy consumption 35/55°C [kWh]2629/3173
Space heating energy efficiency eta s161/136
Nominal heating output at A7/W35 1) [kW]6, 25
Nominal heating capacity at A2/W35 1) [kW]4.33
Nominal heating capacity at A-7/W35 1) [kW]3.82
COP at A7/W35° 1) 5.10
COP at A2/W35° 1) 4, 09
COP at A-7/W35° 1) 3.55
Cooling capacity /W7 KW/EER 2)4.90
Nominal heating volume flow [m³/h]1.1
Flow temperature heating water max. [°C]65
Max. Max. pressure loss heating system [kPa]60
Refrigerant/base charge [-/kg]R 454B / 1.1
GWP value 466
CO² equivalent [t] 0.51
Voltage supply comp. IM [V/~/Hz]230V/1~/50
Power supply Smart Control IM [V/~/Hz]230/1/50
Power supply E-heating element IM [V/~/Hz] 400V/3~/50
Nominal power consumption (A7/W35) [kW]1.22
Nominal current consumption (A7/W35) [A]3, 05
Sound power level AM LpA nominal [dB(A)]56
Sound pressure level nominal AM LpA [dB(A)] 3)33
Sound power level AM LpA night [dB(A)]54
Sound pressure level AM night LpA [dB(A)] 3)30
Dimensions AM HxWxD [mm]1600x1000x800
Outer module weight [kg]180, 00
1) COP = Coefficient Of Performance according to EN 14511, VDE tested
2) EER=Energy Efficiency Ratio according to EN 14511
3) with semi-formal dispersion at 6m, A7/W55 measurement according to DIN EN 12102 and DIN EN ISO 9614-2
The devices comply with the relevant EU regulations and are CE-marked in accordance with the applicable directives.
Additional information
Product group:
4106
Depth:
800mm
Type:
STD
Related results
Complete catalogs
The offer is aimed exclusively at business customers, companies, public institutions, tradesmen and freelancers. All prices in catalogues are exclusive of VAT, shipping costs and surcharges if applicable.
The manufacturer is exclusively responsible for the content, price and article details of the products and offers presented in the catalogues. Subject to technical and optical changes by the manufacturer and errors excepted.
The manufacturer is exclusively responsible for the content, price and article details of the products and offers presented in the catalogues. Subject to technical and optical changes by the manufacturer and errors excepted.
Product suggestions
-10%
Device cover SKW 520 IT
1113560
€62.51
-19%
RK WP Fresh water station
260182
€4,611.92
€5,680.00 MSRP
Oil nozzle 1.75/80 size S DZH 90
1107372
€25.00
-14%
Outer casing INOX ELT 10-HT
1101511
€286.85
Silencer RK 70
1104117
€7.10
-4%
Quick coupling suction line BL 263/353 DC AT
1113540
€53.49
-14%
ATY 267 DC IT Deco
1624472
€338.49
-14%
Control board RVT 681 DC AT
1109849
€453.07
-19%
ZA axial fan 501-4
1108376
€808.06
€994.41 MSRP
-10%
Condenser board RXT 1401 DC
1111958
€76.39
-14%
Relay board WP-Manager (WMZ version) CMT 120/160
1120194
€297.69
-4%
Insert (Vent. plug)
1108317
€33.95
Oil nozzle 2.25/60 degree S
1102823
€23.82
Side panel housing, right ATY 355 DC AT
1113626
€24.79
Condensate nozzle RVD 684/MVD 701-1001
1114421
€9.20
No Review yet
Description: No Review yet
Written by: No Review
Rating: 5 out of 5
5 stars, based on 1
reviews
Remko WP L/W Monobloc heat pump LWM 80 ALU 262081
REMKO GmbH & Co. KG 262081
Remko 262081
262081
4026415149833
monobloc heat pumps
Air/water monobloc heat pump for heating/cooling and hot water operation. Housing in an attractive design in combination with sound insulation and a silver-painted sheet steel front (RAL 9006). Air guide fins in aluminium silver (RAL 9006), Designline aluminium. Fully hermetic refrigerant circuit with LOW-GWP refrigerant R 454B, with filter, receiver, scroll compressor and electronic expansion valve. High-efficiency controlled heating circuit pump, plate heat exchanger and electrical flow monitor. Microprocessor-controlled heat output regulation by means of an externally installed Smart Control.
REMKO Smart-Control Touch
All functions of the heat pump and the heating circuits can be set using the Smart Control touch display. The intuitive controller software with plain text menu and commissioning wizard makes installation, maintenance and integration of additional modules easier for the installer.
Control of one unmixed and two mixed heating circuits (floor or radiators) with different flow temperatures, DHW preparation and temperature control can be realised. Depending on the system version, the required I/O module is supplied in the indoor module with an enamelled DHW cylinder (300L) or in an attractive surface-mounted housing with cable entries. The 4.3’ touch display with WLAN function is supplied in a separate surface-mounted housing and can also be installed flexibly in other rooms. Dew point control is possible via a separately installed humidity/temperature sensor. This is required for temperature control, e.g. cooling via a floor circuit. We recommend installing an additional dew point monitor (Remko EDP no. 259070) when temperature control is activated via panel heating systems.
Included as standard:
Safety group with SIV, automatic air vent and pressure gauge for heating circuit
2 shut-off valves 1‘ for heating circuits
1 dirt filter 1’ for heating circuits
1 outdoor sensor,
1 immersion sensor (intended for DHW heating)
Available as accessories:
Electr. Overflow valve 1”
Sludge separator
Air separator
Heat transfer medium with frost protection
Contact and immersion sensors for integrating additional system components
Storage systems
Smart Control cable remote control
Smart-Count (heat meter)
Smart-Serv (7.5 kW electric auxiliary heating incl. emergency heating operation)
Smart-Web (emergency heating operation). emergency heating operation)
Smart-Web (Internet access)
3-way changeover valve for domestic hot water preparation
Highly efficient heating circuit pump groups with/without mixer
Technical performance data:
Type designationREMKO LWM 80
Application range heating incl. DHW [kW] 1-7
Application limit heating [°C] -23 to +35
Heating output according to ErP 35/55°C[kW]5.0/5, 0
Efficiency class (heating)A++/A++
Annual energy consumption 35/55°C [kWh]2629/3173
Space heating energy efficiency eta s161/136
Nominal heating output at A7/W35 1) [kW]6, 25
Nominal heating capacity at A2/W35 1) [kW]4.33
Nominal heating capacity at A-7/W35 1) [kW]3.82
COP at A7/W35° 1) 5.10
COP at A2/W35° 1) 4, 09
COP at A-7/W35° 1) 3.55
Cooling capacity /W7 KW/EER 2)4.90
Nominal heating volume flow [m³/h]1.1
Flow temperature heating water max. [°C]65
Max. Max. pressure loss heating system [kPa]60
Refrigerant/base charge [-/kg]R 454B / 1.1
GWP value 466
CO² equivalent [t] 0.51
Voltage supply comp. IM [V/~/Hz]230V/1~/50
Power supply Smart Control IM [V/~/Hz]230/1/50
Power supply E-heating element IM [V/~/Hz] 400V/3~/50
Nominal power consumption (A7/W35) [kW]1.22
Nominal current consumption (A7/W35) [A]3, 05
Sound power level AM LpA nominal [dB(A)]56
Sound pressure level nominal AM LpA [dB(A)] 3)33
Sound power level AM LpA night [dB(A)]54
Sound pressure level AM night LpA [dB(A)] 3)30
Dimensions AM HxWxD [mm]1600x1000x800
Outer module weight [kg]180, 00
1) COP = Coefficient Of Performance according to EN 14511, VDE tested
2) EER=Energy Efficiency Ratio according to EN 14511
3) with semi-formal dispersion at 6m, A7/W55 measurement according to DIN EN 12102 and DIN EN ISO 9614-2
The devices comply with the relevant EU regulations and are CE-marked in accordance with the applicable directives. T-385475 262081 4026415149833 en ["de","en","it","nl","nl","fr","es","pl","pt","cs","da","sv"] https://www.toolteam.com/en-GB/remko-wp-l-w-monobloc-heat-pump-lwm-80-alu-262081-t-385475-4026415149833?dc=GB&cu=EUR 2026-08-30 10328.15 United Kingdom GB DE 14
REMKO Smart-Control Touch
All functions of the heat pump and the heating circuits can be set using the Smart Control touch display. The intuitive controller software with plain text menu and commissioning wizard makes installation, maintenance and integration of additional modules easier for the installer.
Control of one unmixed and two mixed heating circuits (floor or radiators) with different flow temperatures, DHW preparation and temperature control can be realised. Depending on the system version, the required I/O module is supplied in the indoor module with an enamelled DHW cylinder (300L) or in an attractive surface-mounted housing with cable entries. The 4.3’ touch display with WLAN function is supplied in a separate surface-mounted housing and can also be installed flexibly in other rooms. Dew point control is possible via a separately installed humidity/temperature sensor. This is required for temperature control, e.g. cooling via a floor circuit. We recommend installing an additional dew point monitor (Remko EDP no. 259070) when temperature control is activated via panel heating systems.
Included as standard:
Safety group with SIV, automatic air vent and pressure gauge for heating circuit
2 shut-off valves 1‘ for heating circuits
1 dirt filter 1’ for heating circuits
1 outdoor sensor,
1 immersion sensor (intended for DHW heating)
Available as accessories:
Electr. Overflow valve 1”
Sludge separator
Air separator
Heat transfer medium with frost protection
Contact and immersion sensors for integrating additional system components
Storage systems
Smart Control cable remote control
Smart-Count (heat meter)
Smart-Serv (7.5 kW electric auxiliary heating incl. emergency heating operation)
Smart-Web (emergency heating operation). emergency heating operation)
Smart-Web (Internet access)
3-way changeover valve for domestic hot water preparation
Highly efficient heating circuit pump groups with/without mixer
Technical performance data:
Type designationREMKO LWM 80
Application range heating incl. DHW [kW] 1-7
Application limit heating [°C] -23 to +35
Heating output according to ErP 35/55°C[kW]5.0/5, 0
Efficiency class (heating)A++/A++
Annual energy consumption 35/55°C [kWh]2629/3173
Space heating energy efficiency eta s161/136
Nominal heating output at A7/W35 1) [kW]6, 25
Nominal heating capacity at A2/W35 1) [kW]4.33
Nominal heating capacity at A-7/W35 1) [kW]3.82
COP at A7/W35° 1) 5.10
COP at A2/W35° 1) 4, 09
COP at A-7/W35° 1) 3.55
Cooling capacity /W7 KW/EER 2)4.90
Nominal heating volume flow [m³/h]1.1
Flow temperature heating water max. [°C]65
Max. Max. pressure loss heating system [kPa]60
Refrigerant/base charge [-/kg]R 454B / 1.1
GWP value 466
CO² equivalent [t] 0.51
Voltage supply comp. IM [V/~/Hz]230V/1~/50
Power supply Smart Control IM [V/~/Hz]230/1/50
Power supply E-heating element IM [V/~/Hz] 400V/3~/50
Nominal power consumption (A7/W35) [kW]1.22
Nominal current consumption (A7/W35) [A]3, 05
Sound power level AM LpA nominal [dB(A)]56
Sound pressure level nominal AM LpA [dB(A)] 3)33
Sound power level AM LpA night [dB(A)]54
Sound pressure level AM night LpA [dB(A)] 3)30
Dimensions AM HxWxD [mm]1600x1000x800
Outer module weight [kg]180, 00
1) COP = Coefficient Of Performance according to EN 14511, VDE tested
2) EER=Energy Efficiency Ratio according to EN 14511
3) with semi-formal dispersion at 6m, A7/W55 measurement according to DIN EN 12102 and DIN EN ISO 9614-2
The devices comply with the relevant EU regulations and are CE-marked in accordance with the applicable directives. T-385475 262081 4026415149833 en ["de","en","it","nl","nl","fr","es","pl","pt","cs","da","sv"] https://www.toolteam.com/en-GB/remko-wp-l-w-monobloc-heat-pump-lwm-80-alu-262081-t-385475-4026415149833?dc=GB&cu=EUR 2026-08-30 10328.15 United Kingdom GB DE 14