zoom_in
zoom_out
fullscreen
-19%
Remko WP KWK 420-4R, versatile in use 1663420
Sku: T-384557
€706.89 (excl. legal VAT, excl. Shipping)
€870.00 MSRP
In stock,ready for shipping within 24h
Package
Product variants
| Sku: | Name: | SKU manufacturer: | ||
|---|---|---|---|---|
|
T-384507 | Air conditioning chilled water KWK 130 | 1662210 | |
|
T-384509 | Air conditioning chilled water CHP 140 | 1662220 | |
|
T-384511 | Air conditioning cold water KWK 200 | 1662230 | |
|
T-384513 | Air conditioning cold water KWK 220 | 1662240 | |
|
T-384515 | Air conditioning cold water KWK 280 | 1662250 | |
|
T-384517 | Air conditioning cold water KWK 300 | 1662260 | |
|
T-384519 | Air conditioning cold water CHP 360 | 1662270 | |
|
T-384521 | Air conditioning cold water KWK 420 | 1662280 | |
|
T-384523 | Air conditioning cold water KWK 590 | 1662290 | |
|
T-384525 | Air conditioning cold water KWK 680 | 1662300 | |
|
T-384527 | Air conditioning cold water KWK 740 | 1662310 | |
|
T-384529 | Air conditioning cold water KWK 870 | 1662320 | |
|
T-384534 | Air conditioning chilled water KWK 140 EC | 1662500 | |
|
T-384536 | Air conditioning cold water KWK 220 EC | 1662510 | |
|
T-384538 | Air conditioning cold water KWK 300 EC | 1662520 | |
|
T-384540 | Air conditioning cold water KWK 500 EC | 1662530 | |
|
T-384542 | Air conditioning cold water KWK 690 EC | 1662540 | |
|
T-384544 | Air conditioning chilled water KWK 830 EC | 1662550 | |
|
T-384553 | WP KWK 130-4R, versatile in use | 1663130 | |
|
T-384555 | WP KWK 220-4R, versatile in use | 1663220 | |
|
T-384556 | WP KWK 300-4R, versatile in use | 1663300 |
doneProduct group: 4001
doneType: STD
doneType: STD
Remko WP KWK 420-4R 1663420, versatile application
Content:
1 Package
Shipping:
€167.98 Versandservice to United Kingdom
plus €18.20 stock transfer surcharge

Lieferung:
Provider:
Sales and delivery by ToolTeam Köln
Payment methods:
Returns:
Security:
Product data
Manufacturer:
REMKO GmbH & Co. KG
Condition:
NEW
Sku:
T-384557
SKU manufacturer:
1663420
GTIN Code (EAN):
4026415119584
Weight:
34,25 Kg
All information relating to products from REMKO GmbH & Co. KG. Technical and optical modifications of the manufacturer and errors reserved.
This page has been machine-translated, the original german version can be found here, please also note the Translation Disclaimer.
Product description
Hot/cold water chest unit for wall or ceiling mounting in a two-pipe system with large heat exchanger for low medium temperatures.
Easily removable unit cover made of galvanised sheet steel with white base coat and polyester coating, similar to RAL 9016. Vertical air inlet on the underside of the unit with large, regenerable air filter. Vertical air outlet (wall mounting) or horizontal (ceiling mounting) via elegant white plastic outlet grille with side control panel for optional room temperature control (accessory). An extremely smooth-running, low-noise centrifugal fan with three-speed adjustable, thermally protected drive motor, statically and dynamically balanced. Optimum adaptation to requirements thanks to 3 variable speed levels. Air heater or air cooler as four-pipe heat exchanger in Cu/Al design made of seamless drawn copper pipe with form-fit aluminium fins for hot or cold water or water/glycol mixture up to max. 80°C. Tightness tested at the factory. Brass pipe connections in imperial design with bleed and drain valves provided on the left-hand side of the appliance at the factory. Depending on the installation variant, the coil connection side and the condensate connection can be exchanged. Insulated condensate drip tray made of sheet steel for vertical and another for horizontal installation. The device can be operated either via an internal or external room temperature control. When the room temperature is reached, the fans switch off.
The medium volume flow can also be controlled by an optional 3-way valve assembly in the unit.
Accessories available:
Condensate pump, room temperature control for surface mounting, room temperature control for mounting in the unit, switching relay for 4 units, valve assembly two-pipe system, feet, air inlet base, fault signal module
The units comply with the relevant EU regulations and are CE-labelled in accordance with the applicable directives.
Technical performance data:
Type designationREMKO KWK 420-4R
Nominal heating capacity 35/30 per stage 2) [kW]2.71/1.97/1.29
Nominal heating capacity 40/35 per stage 2) [kW]3.91/2.83/1.84
Nominal heating capacity 45/40 per stage 2) [kW]5.10/3.69/2.38
Nominal cooling capacity, sensitive per stage 1) [kW]4.13/3.02/1, 97
Nominal cooling capacity, total per stage 1) [kW]5.89/4.37/2.89
Working range, indoor unit [°C]+15 to +35
Air flow rate, per stage [m³/h]328/524/751
Sound pressure level, per stage 3) [dB(A)]24/36/44
Voltage supply [V/~/Hz]230/1/50
Protection classIP X0
Electr. Nominal power consumption heating 2) [kW]92
Nominal electrical power consumption cooling 1) [A]0.38
Operating mediumwater or
max. 35% ethylene/
propylene glycol
Operating pressure, max. medium [kPa Medium [kPa]600
Nominal flow rate, medium heating 2) [m³/h]0.88
Nominal flow rate, medium cooling 1) [m³/h]8.40
Nominal pressure losses, internal cooling 1) [kPa]40.1
Nominal pressure losses, internal heating 2) [kPa]14, 0
Medium connections1/2”
Medium capacity [l]2.2
Condensate connection [mm]19
Dimensions (H/W/D) [mm]478/1109/219
Weight [kg]23.0
1) Air inlet TK 27°C / FK 19°C, medium temperatures 7/12 °C, 0% glycol concentration, max. air volume flow rate [mm air volume flow rate
2) Air inlet 20°C, 0% glycol concentration, max. air volume flow rate
3) Distance 1.5 m in a 100m² room with a reverberation time of 0.3s, directional factor 4
Easily removable unit cover made of galvanised sheet steel with white base coat and polyester coating, similar to RAL 9016. Vertical air inlet on the underside of the unit with large, regenerable air filter. Vertical air outlet (wall mounting) or horizontal (ceiling mounting) via elegant white plastic outlet grille with side control panel for optional room temperature control (accessory). An extremely smooth-running, low-noise centrifugal fan with three-speed adjustable, thermally protected drive motor, statically and dynamically balanced. Optimum adaptation to requirements thanks to 3 variable speed levels. Air heater or air cooler as four-pipe heat exchanger in Cu/Al design made of seamless drawn copper pipe with form-fit aluminium fins for hot or cold water or water/glycol mixture up to max. 80°C. Tightness tested at the factory. Brass pipe connections in imperial design with bleed and drain valves provided on the left-hand side of the appliance at the factory. Depending on the installation variant, the coil connection side and the condensate connection can be exchanged. Insulated condensate drip tray made of sheet steel for vertical and another for horizontal installation. The device can be operated either via an internal or external room temperature control. When the room temperature is reached, the fans switch off.
The medium volume flow can also be controlled by an optional 3-way valve assembly in the unit.
Accessories available:
Condensate pump, room temperature control for surface mounting, room temperature control for mounting in the unit, switching relay for 4 units, valve assembly two-pipe system, feet, air inlet base, fault signal module
The units comply with the relevant EU regulations and are CE-labelled in accordance with the applicable directives.
Technical performance data:
Type designationREMKO KWK 420-4R
Nominal heating capacity 35/30 per stage 2) [kW]2.71/1.97/1.29
Nominal heating capacity 40/35 per stage 2) [kW]3.91/2.83/1.84
Nominal heating capacity 45/40 per stage 2) [kW]5.10/3.69/2.38
Nominal cooling capacity, sensitive per stage 1) [kW]4.13/3.02/1, 97
Nominal cooling capacity, total per stage 1) [kW]5.89/4.37/2.89
Working range, indoor unit [°C]+15 to +35
Air flow rate, per stage [m³/h]328/524/751
Sound pressure level, per stage 3) [dB(A)]24/36/44
Voltage supply [V/~/Hz]230/1/50
Protection classIP X0
Electr. Nominal power consumption heating 2) [kW]92
Nominal electrical power consumption cooling 1) [A]0.38
Operating mediumwater or
max. 35% ethylene/
propylene glycol
Operating pressure, max. medium [kPa Medium [kPa]600
Nominal flow rate, medium heating 2) [m³/h]0.88
Nominal flow rate, medium cooling 1) [m³/h]8.40
Nominal pressure losses, internal cooling 1) [kPa]40.1
Nominal pressure losses, internal heating 2) [kPa]14, 0
Medium connections1/2”
Medium capacity [l]2.2
Condensate connection [mm]19
Dimensions (H/W/D) [mm]478/1109/219
Weight [kg]23.0
1) Air inlet TK 27°C / FK 19°C, medium temperatures 7/12 °C, 0% glycol concentration, max. air volume flow rate [mm air volume flow rate
2) Air inlet 20°C, 0% glycol concentration, max. air volume flow rate
3) Distance 1.5 m in a 100m² room with a reverberation time of 0.3s, directional factor 4
Additional information
Product group:
4001
Width (mm):
1109.0MMT
Height (mm):
478.0MMT
Length (mm):
219.0MMT
Type:
STD
Related results
Complete catalogs
The offer is aimed exclusively at business customers, companies, public institutions, tradesmen and freelancers. All prices in catalogues are exclusive of VAT, shipping costs and surcharges if applicable.
The manufacturer is exclusively responsible for the content, price and article details of the products and offers presented in the catalogues. Subject to technical and optical changes by the manufacturer and errors excepted.
The manufacturer is exclusively responsible for the content, price and article details of the products and offers presented in the catalogues. Subject to technical and optical changes by the manufacturer and errors excepted.
Matching catalog
Commercial customer offer**
Product suggestions
-10%
Base plate AMT 65/85-E
1105957
€118.53
Oil nozzle 1.75/80 size S DZH 90
1107372
€25.00
-19%
RK WP fresh water station
260181
€2,691.25
€3,312.01 MSRP
Condensate nozzle with plug MKT 240/250
1106882
€10.17
Whirler WKL/VRS 50-60
1102954
€22.14
-14%
ATY 267 Deco
1623430
€445.62
-13%
Condensate drip tray KWK 450/600 (ZW)
1111783
€169.33
-4%
Condensate container ETF/AMT
1104429
€61.09
-13%
Power board 954460 RVS
1106710
€128.53
RK Netzstecker
1123916
€12.82
Condensate nozzle RVD 684/MVD 701-1001
1114421
€9.20
Accessory pack 1
1106445
€21.67
-14%
Relay board WP-Manager (WMZ version) CMT 120/160
1120194
€297.69
-4%
Quick coupling suction line BL 263/353 DC AT
1113540
€53.49
-4%
Support ring, 1-piece RK 25-50
1104168
€43.87
No Review yet
Description: No Review yet
Written by: No Review
Rating: 5 out of 5
5 stars, based on 1
reviews
Remko WP KWK 420-4R, versatile in use 1663420
REMKO GmbH & Co. KG 1663420
Remko 1663420
1663420
4026415119584
chilled water air conditioning systems
Hot/cold water chest unit for wall or ceiling mounting in a two-pipe system with large heat exchanger for low medium temperatures.
Easily removable unit cover made of galvanised sheet steel with white base coat and polyester coating, similar to RAL 9016. Vertical air inlet on the underside of the unit with large, regenerable air filter. Vertical air outlet (wall mounting) or horizontal (ceiling mounting) via elegant white plastic outlet grille with side control panel for optional room temperature control (accessory). An extremely smooth-running, low-noise centrifugal fan with three-speed adjustable, thermally protected drive motor, statically and dynamically balanced. Optimum adaptation to requirements thanks to 3 variable speed levels. Air heater or air cooler as four-pipe heat exchanger in Cu/Al design made of seamless drawn copper pipe with form-fit aluminium fins for hot or cold water or water/glycol mixture up to max. 80°C. Tightness tested at the factory. Brass pipe connections in imperial design with bleed and drain valves provided on the left-hand side of the appliance at the factory. Depending on the installation variant, the coil connection side and the condensate connection can be exchanged. Insulated condensate drip tray made of sheet steel for vertical and another for horizontal installation. The device can be operated either via an internal or external room temperature control. When the room temperature is reached, the fans switch off.
The medium volume flow can also be controlled by an optional 3-way valve assembly in the unit.
Accessories available:
Condensate pump, room temperature control for surface mounting, room temperature control for mounting in the unit, switching relay for 4 units, valve assembly two-pipe system, feet, air inlet base, fault signal module
The units comply with the relevant EU regulations and are CE-labelled in accordance with the applicable directives.
Technical performance data:
Type designationREMKO KWK 420-4R
Nominal heating capacity 35/30 per stage 2) [kW]2.71/1.97/1.29
Nominal heating capacity 40/35 per stage 2) [kW]3.91/2.83/1.84
Nominal heating capacity 45/40 per stage 2) [kW]5.10/3.69/2.38
Nominal cooling capacity, sensitive per stage 1) [kW]4.13/3.02/1, 97
Nominal cooling capacity, total per stage 1) [kW]5.89/4.37/2.89
Working range, indoor unit [°C]+15 to +35
Air flow rate, per stage [m³/h]328/524/751
Sound pressure level, per stage 3) [dB(A)]24/36/44
Voltage supply [V/~/Hz]230/1/50
Protection classIP X0
Electr. Nominal power consumption heating 2) [kW]92
Nominal electrical power consumption cooling 1) [A]0.38
Operating mediumwater or
max. 35% ethylene/
propylene glycol
Operating pressure, max. medium [kPa Medium [kPa]600
Nominal flow rate, medium heating 2) [m³/h]0.88
Nominal flow rate, medium cooling 1) [m³/h]8.40
Nominal pressure losses, internal cooling 1) [kPa]40.1
Nominal pressure losses, internal heating 2) [kPa]14, 0
Medium connections1/2”
Medium capacity [l]2.2
Condensate connection [mm]19
Dimensions (H/W/D) [mm]478/1109/219
Weight [kg]23.0
1) Air inlet TK 27°C / FK 19°C, medium temperatures 7/12 °C, 0% glycol concentration, max. air volume flow rate [mm air volume flow rate
2) Air inlet 20°C, 0% glycol concentration, max. air volume flow rate
3) Distance 1.5 m in a 100m² room with a reverberation time of 0.3s, directional factor 4 T-384557 1663420 4026415119584 en ["de","en","it","nl","nl","fr","es","pl","pt","cs","da","sv"] https://www.toolteam.com/en-GB/remko-wp-kwk-420-4r-versatile-in-use-1663420-t-384557-4026415119584?dc=GB&cu=EUR 2026-07-14 706.89 United Kingdom GB DE 14
Easily removable unit cover made of galvanised sheet steel with white base coat and polyester coating, similar to RAL 9016. Vertical air inlet on the underside of the unit with large, regenerable air filter. Vertical air outlet (wall mounting) or horizontal (ceiling mounting) via elegant white plastic outlet grille with side control panel for optional room temperature control (accessory). An extremely smooth-running, low-noise centrifugal fan with three-speed adjustable, thermally protected drive motor, statically and dynamically balanced. Optimum adaptation to requirements thanks to 3 variable speed levels. Air heater or air cooler as four-pipe heat exchanger in Cu/Al design made of seamless drawn copper pipe with form-fit aluminium fins for hot or cold water or water/glycol mixture up to max. 80°C. Tightness tested at the factory. Brass pipe connections in imperial design with bleed and drain valves provided on the left-hand side of the appliance at the factory. Depending on the installation variant, the coil connection side and the condensate connection can be exchanged. Insulated condensate drip tray made of sheet steel for vertical and another for horizontal installation. The device can be operated either via an internal or external room temperature control. When the room temperature is reached, the fans switch off.
The medium volume flow can also be controlled by an optional 3-way valve assembly in the unit.
Accessories available:
Condensate pump, room temperature control for surface mounting, room temperature control for mounting in the unit, switching relay for 4 units, valve assembly two-pipe system, feet, air inlet base, fault signal module
The units comply with the relevant EU regulations and are CE-labelled in accordance with the applicable directives.
Technical performance data:
Type designationREMKO KWK 420-4R
Nominal heating capacity 35/30 per stage 2) [kW]2.71/1.97/1.29
Nominal heating capacity 40/35 per stage 2) [kW]3.91/2.83/1.84
Nominal heating capacity 45/40 per stage 2) [kW]5.10/3.69/2.38
Nominal cooling capacity, sensitive per stage 1) [kW]4.13/3.02/1, 97
Nominal cooling capacity, total per stage 1) [kW]5.89/4.37/2.89
Working range, indoor unit [°C]+15 to +35
Air flow rate, per stage [m³/h]328/524/751
Sound pressure level, per stage 3) [dB(A)]24/36/44
Voltage supply [V/~/Hz]230/1/50
Protection classIP X0
Electr. Nominal power consumption heating 2) [kW]92
Nominal electrical power consumption cooling 1) [A]0.38
Operating mediumwater or
max. 35% ethylene/
propylene glycol
Operating pressure, max. medium [kPa Medium [kPa]600
Nominal flow rate, medium heating 2) [m³/h]0.88
Nominal flow rate, medium cooling 1) [m³/h]8.40
Nominal pressure losses, internal cooling 1) [kPa]40.1
Nominal pressure losses, internal heating 2) [kPa]14, 0
Medium connections1/2”
Medium capacity [l]2.2
Condensate connection [mm]19
Dimensions (H/W/D) [mm]478/1109/219
Weight [kg]23.0
1) Air inlet TK 27°C / FK 19°C, medium temperatures 7/12 °C, 0% glycol concentration, max. air volume flow rate [mm air volume flow rate
2) Air inlet 20°C, 0% glycol concentration, max. air volume flow rate
3) Distance 1.5 m in a 100m² room with a reverberation time of 0.3s, directional factor 4 T-384557 1663420 4026415119584 en ["de","en","it","nl","nl","fr","es","pl","pt","cs","da","sv"] https://www.toolteam.com/en-GB/remko-wp-kwk-420-4r-versatile-in-use-1663420-t-384557-4026415119584?dc=GB&cu=EUR 2026-07-14 706.89 United Kingdom GB DE 14