zoom_in
zoom_out
fullscreen
-19%
Remko WKM 100 Graphite L/W Monobloc heat pump 265005
Sku: T-1514446
€5,659.33 (excl. legal VAT, excl. Shipping)
(€2,829.66 / Piece)
€6,970.00 MSRP
In stock,ready for shipping
Carton
Product variants
| Sku: | Name: | SKU manufacturer: | ||
|---|---|---|---|---|
|
T-1514447 | WKM 100 Designline Graphite L/W Monobloc heat pump | 265006 | |
|
T-1514448 | WKM 130 Graphite L/W Monobloc heat pump | 265010 | |
|
T-1514449 | WKM 130 Designline Graphite L/W Monobloc heat pump | 265011 |
doneNo usage notice required
doneWKM 100 Graphit
doneWKM 100 Graphit
doneL/W monoblock heat pump
doneConsists of: 260019|259101|1122281|265006
doneConsists of: 260019|259101|1122281|265006
L/W Monoblock Wärmepumpe
Content:
1 Carton = 2 Piece (€2,829.66 / Piece)
Shipping:
€378.07 Versandservice to United Kingdom
For orders from €1,000.00 order total plus €34.45 Customs MRN registration
Lieferung:
Provider:
Sales and delivery by ToolTeam Köln
Payment methods:
Returns:
Security:
Product data
Manufacturer:
REMKO GmbH & Co. KG
Condition:
NEW
Sku:
T-1514446
SKU manufacturer:
265005
GTIN Code (EAN):
4026415187033
Weight:
107,97 Kg
All information relating to products from REMKO GmbH & Co. KG. Technical and optical modifications of the manufacturer and errors reserved.
This page has been machine-translated, the original german version can be found here, please also note the Translation Disclaimer.
Product description
Air/water monobloc heat pump for heating/cooling and hot water operation. Housing in an attractive design in combination with sound insulation and a silver-painted sheet steel front (RAL 9006). Air guide fins in anthracite (RAL 7021), graphite design line. Fully hermetic refrigerant circuit with LOW-GWP refrigerant R 32, with filter, receiver, inverter compressor and electronic expansion valve. High-efficiency controlled heating circuit pump, plate heat exchanger and electrical flow monitor. A 3-stage electric heating element 6/9 kW is integrated as standard. Microprocessor-controlled heat output regulation by means of an externally installed Smart Control
REMKO Smart-Control Touch
All functions of the heat pump and heating circuits can be set using the Smart Control touch display. The intuitive controller software with plain text menu and commissioning wizard makes installation, maintenance and integration of additional modules easier for the installer.
Control of one unmixed and one mixed heating circuit (floor or radiator) with different flow temperatures, DHW preparation and temperature control can be realised. The required I/O module is supplied in an attractive surface-mounted housing with cable entries. The 4.3’ touch display with WLAN function is supplied in a separate surface-mounted housing and can also be installed flexibly in other rooms. Dew point control is possible via a separately installed humidity/temperature sensor. This is required for temperature control, e.g. cooling via a floor circuit. We recommend installing an additional dew point monitor (Remko EDP no. 259070) when temperature control is activated via panel heating systems. Other functions included as standard
EVU contact, SG-Ready contacts, Smart Heating/Cooling function (variant 2B) (PV self-consumption), cooling active, cooling valve and pump control via a contact
Temperature control via max. 2 rooms. Humidity sensor via Modbus, three-stage heating element, bivalent operation / boiler activation, thermal and pulse-controlled circulation operation
Included in the standard scope of delivery:
Safety group with SIV, automatic air vent and pressure gauge for heating circuit
2 shut-off valves 1‘ for heating circuits
1 dirt filter 1’ for heating circuits
1 outdoor sensor,
1 immersion sensor (intended for DHW heating)
1 Smart Control
1 Smart Serv 6/9kW
Available as accessories:
Electr. Overflow valve 1”
Sludge separator
Air separator
Heat transfer medium with frost protection
Contact and immersion sensors for integrating additional system components
Storage systems
Smart Control cable remote control
Smart Count (heat meter)
Smart Serv (7.5 kW electric auxiliary heating incl. emergency heating operation)
Smart Web (Smart Control 6/9kWA) emergency heating operation)
Smart-Web (Internet access)
3-way changeover valve for domestic hot water preparation
Highly efficient heating circuit pump groups with/without mixer
Frost protection heating
Technical performance data:
Type designationREMKO WKM 100
Application range heating incl. DHW [kW] 6-9 kW
Application limit heating [°C] - 20 to +43
Heating output according to ErP 35/55°C [kW]6/6
Efficiency class (heating)A+++/A++
Annual energy consumption 35/55°C [kWh]3104/3971
Space heating energy efficiency eta s190/138
Nominal heating output at A7/W35 1) [kW]8, 87
Nominal heating capacity at A7/W27 2) [kW]3.21
Nominal heating capacity at A2/W35 1) [kW]7, 01
Nominal heating capacity at A2/W30 2) [kW]3.75
Nominal heating capacity at A-7/W35 1) [kW]4.95
Nominal heating capacity at A-7/W34 2) [kW]5.72
COP at A7/W35° 1) 4.68
COP at A7/W27° 2) 6.22
COP at A2/W35 1)4, 06
COP at A2/W30° 2) 4.44
COP at A-7/W35° 1)3.01
COP at A-7/W34° 2) 3.16
Cooling capacity A35/W7 KW/EER 1)5.5/3.09
Nominal heating volume flow [m³/h]1.35
Max. heating water flow temp. [°C]60
Max. Max. pressure loss heating system [kPa]80
Refrigerant/base charge [-/kg]R 32 / 1.4
GWP value 675
CO² equivalent [t] 0.41
Voltage supply comp. IM [V/~/Hz]230V/1~/50
Power supply Smart Control IM [V/~/Hz]230/1/50
Power supply E-heating element IM [V/~/Hz] 400V/3~/50
Nominal power consumption (A7/W35) [kW]1.89
Nominal current consumption (A7/W35) [A]8, 21
Sound power level AM LpA nominal [dB(A)]58
Sound pressure level nominal AM LpA [dB(A)] 3)31
Sound power level AM LpA night [dB(A)]55
Sound pressure level AM night LpA [dB(A)] 3)30
Dimensions AM HxWxD [mm]850x1200x375
Outer module weight [kg]85, 00
1) COP = Coefficient Of Performance according to EN 14511, EER=Energy Efficiency Ratio according to EN 14511. VDE tested
2)COP = Coefficient Of Performance in accordance with EN 14825,
3) with semi-formal dispersion at 5m, A7/W35 measurement in accordance with DIN EN 12102
The appliances comply with the relevant EU regulations and are CE-marked in accordance with the applicable directives.
REMKO Smart-Control Touch
All functions of the heat pump and heating circuits can be set using the Smart Control touch display. The intuitive controller software with plain text menu and commissioning wizard makes installation, maintenance and integration of additional modules easier for the installer.
Control of one unmixed and one mixed heating circuit (floor or radiator) with different flow temperatures, DHW preparation and temperature control can be realised. The required I/O module is supplied in an attractive surface-mounted housing with cable entries. The 4.3’ touch display with WLAN function is supplied in a separate surface-mounted housing and can also be installed flexibly in other rooms. Dew point control is possible via a separately installed humidity/temperature sensor. This is required for temperature control, e.g. cooling via a floor circuit. We recommend installing an additional dew point monitor (Remko EDP no. 259070) when temperature control is activated via panel heating systems. Other functions included as standard
EVU contact, SG-Ready contacts, Smart Heating/Cooling function (variant 2B) (PV self-consumption), cooling active, cooling valve and pump control via a contact
Temperature control via max. 2 rooms. Humidity sensor via Modbus, three-stage heating element, bivalent operation / boiler activation, thermal and pulse-controlled circulation operation
Included in the standard scope of delivery:
Safety group with SIV, automatic air vent and pressure gauge for heating circuit
2 shut-off valves 1‘ for heating circuits
1 dirt filter 1’ for heating circuits
1 outdoor sensor,
1 immersion sensor (intended for DHW heating)
1 Smart Control
1 Smart Serv 6/9kW
Available as accessories:
Electr. Overflow valve 1”
Sludge separator
Air separator
Heat transfer medium with frost protection
Contact and immersion sensors for integrating additional system components
Storage systems
Smart Control cable remote control
Smart Count (heat meter)
Smart Serv (7.5 kW electric auxiliary heating incl. emergency heating operation)
Smart Web (Smart Control 6/9kWA) emergency heating operation)
Smart-Web (Internet access)
3-way changeover valve for domestic hot water preparation
Highly efficient heating circuit pump groups with/without mixer
Frost protection heating
Technical performance data:
Type designationREMKO WKM 100
Application range heating incl. DHW [kW] 6-9 kW
Application limit heating [°C] - 20 to +43
Heating output according to ErP 35/55°C [kW]6/6
Efficiency class (heating)A+++/A++
Annual energy consumption 35/55°C [kWh]3104/3971
Space heating energy efficiency eta s190/138
Nominal heating output at A7/W35 1) [kW]8, 87
Nominal heating capacity at A7/W27 2) [kW]3.21
Nominal heating capacity at A2/W35 1) [kW]7, 01
Nominal heating capacity at A2/W30 2) [kW]3.75
Nominal heating capacity at A-7/W35 1) [kW]4.95
Nominal heating capacity at A-7/W34 2) [kW]5.72
COP at A7/W35° 1) 4.68
COP at A7/W27° 2) 6.22
COP at A2/W35 1)4, 06
COP at A2/W30° 2) 4.44
COP at A-7/W35° 1)3.01
COP at A-7/W34° 2) 3.16
Cooling capacity A35/W7 KW/EER 1)5.5/3.09
Nominal heating volume flow [m³/h]1.35
Max. heating water flow temp. [°C]60
Max. Max. pressure loss heating system [kPa]80
Refrigerant/base charge [-/kg]R 32 / 1.4
GWP value 675
CO² equivalent [t] 0.41
Voltage supply comp. IM [V/~/Hz]230V/1~/50
Power supply Smart Control IM [V/~/Hz]230/1/50
Power supply E-heating element IM [V/~/Hz] 400V/3~/50
Nominal power consumption (A7/W35) [kW]1.89
Nominal current consumption (A7/W35) [A]8, 21
Sound power level AM LpA nominal [dB(A)]58
Sound pressure level nominal AM LpA [dB(A)] 3)31
Sound power level AM LpA night [dB(A)]55
Sound pressure level AM night LpA [dB(A)] 3)30
Dimensions AM HxWxD [mm]850x1200x375
Outer module weight [kg]85, 00
1) COP = Coefficient Of Performance according to EN 14511, EER=Energy Efficiency Ratio according to EN 14511. VDE tested
2)COP = Coefficient Of Performance in accordance with EN 14825,
3) with semi-formal dispersion at 5m, A7/W35 measurement in accordance with DIN EN 12102
The appliances comply with the relevant EU regulations and are CE-marked in accordance with the applicable directives.
Additional information
Product group:
9
Width (mm):
1230.0MMT
Height (mm):
850.0MMT
Type:
PAK
Depth (mm):
395.0MMT
Related results
4026415187033
Remko
265005
REMKO GmbH & Co. KG
Remko
climate
heat
new energies
dehumidification
industrial vacuum cleaners
dehumidifiers
energy efficiency
heating technology
air conditioning systems
environmental technology
pollutant reduction
indoor climate
sustainable energies
commercial dehumidification
Complete catalogs
The offer is aimed exclusively at business customers, companies, public institutions, tradesmen and freelancers. All prices in catalogues are exclusive of VAT, shipping costs and surcharges if applicable.
The manufacturer is exclusively responsible for the content, price and article details of the products and offers presented in the catalogues. Subject to technical and optical changes by the manufacturer and errors excepted.
The manufacturer is exclusively responsible for the content, price and article details of the products and offers presented in the catalogues. Subject to technical and optical changes by the manufacturer and errors excepted.
Product suggestions
Accessory pack 1
1106445
€21.67
-4%
Insert (Vent. plug)
1108317
€33.95
-13%
Oil pump AD1L2 Replacement for V1-LR2 1/4?
1108640
€159.20
Oil nozzle 1.75/80 size S DZH 90
1107372
€25.00
-10%
Base plate AMT 65/85-E
1105957
€118.53
-10%
Reversing valve RXT 681 DC AT
1111598
€73.78
Condensate nozzle RVD 1054 DC IT
1114438
€9.20
Side panel housing, right ATY 355 DC AT
1113626
€24.79
Relay Board Merlin CMF/CMT-New version
1120030-N
€396.93
-10%
Injection nozzle No. 06 RVS 1600
1107332
€77.22
-14%
ATY 357 DC IT Deco
1624482
€407.06
-4%
Pressure gauge 0-6 bar 1/4?
1108426
€59.16
Condensate nozzle with plug MKT 240/250
1106882
€10.17
-14%
Heating circuit pump HGU/HGM Wilo Stratos PARA 25/1-7 T1
1120909
€372.61
-13%
Outer sheath PGT 100
1101681
€227.48
No Review yet
Description: No Review yet
Written by: No Review
Rating: 5 out of 5
5 stars, based on 1
reviews
Remko WKM 100 Graphite L/W Monobloc heat pump 265005
4026415187033
Remko
265005
REMKO GmbH & Co. KG
Remko
climate
heat
new energies
dehumidification
industrial vacuum cleaners
dehumidifiers
energy efficiency
heating technology
air conditioning systems
environmental technology
pollutant reduction
indoor climate
sustainable energies
commercial dehumidification
Air/water monobloc heat pump for heating/cooling and hot water operation. Housing in an attractive design in combination with sound insulation and a silver-painted sheet steel front (RAL 9006). Air guide fins in anthracite (RAL 7021), graphite design line. Fully hermetic refrigerant circuit with LOW-GWP refrigerant R 32, with filter, receiver, inverter compressor and electronic expansion valve. High-efficiency controlled heating circuit pump, plate heat exchanger and electrical flow monitor. A 3-stage electric heating element 6/9 kW is integrated as standard. Microprocessor-controlled heat output regulation by means of an externally installed Smart Control
REMKO Smart-Control Touch
All functions of the heat pump and heating circuits can be set using the Smart Control touch display. The intuitive controller software with plain text menu and commissioning wizard makes installation, maintenance and integration of additional modules easier for the installer.
Control of one unmixed and one mixed heating circuit (floor or radiator) with different flow temperatures, DHW preparation and temperature control can be realised. The required I/O module is supplied in an attractive surface-mounted housing with cable entries. The 4.3’ touch display with WLAN function is supplied in a separate surface-mounted housing and can also be installed flexibly in other rooms. Dew point control is possible via a separately installed humidity/temperature sensor. This is required for temperature control, e.g. cooling via a floor circuit. We recommend installing an additional dew point monitor (Remko EDP no. 259070) when temperature control is activated via panel heating systems. Other functions included as standard
EVU contact, SG-Ready contacts, Smart Heating/Cooling function (variant 2B) (PV self-consumption), cooling active, cooling valve and pump control via a contact
Temperature control via max. 2 rooms. Humidity sensor via Modbus, three-stage heating element, bivalent operation / boiler activation, thermal and pulse-controlled circulation operation
Included in the standard scope of delivery:
Safety group with SIV, automatic air vent and pressure gauge for heating circuit
2 shut-off valves 1‘ for heating circuits
1 dirt filter 1’ for heating circuits
1 outdoor sensor,
1 immersion sensor (intended for DHW heating)
1 Smart Control
1 Smart Serv 6/9kW
Available as accessories:
Electr. Overflow valve 1”
Sludge separator
Air separator
Heat transfer medium with frost protection
Contact and immersion sensors for integrating additional system components
Storage systems
Smart Control cable remote control
Smart Count (heat meter)
Smart Serv (7.5 kW electric auxiliary heating incl. emergency heating operation)
Smart Web (Smart Control 6/9kWA) emergency heating operation)
Smart-Web (Internet access)
3-way changeover valve for domestic hot water preparation
Highly efficient heating circuit pump groups with/without mixer
Frost protection heating
Technical performance data:
Type designationREMKO WKM 100
Application range heating incl. DHW [kW] 6-9 kW
Application limit heating [°C] - 20 to +43
Heating output according to ErP 35/55°C [kW]6/6
Efficiency class (heating)A+++/A++
Annual energy consumption 35/55°C [kWh]3104/3971
Space heating energy efficiency eta s190/138
Nominal heating output at A7/W35 1) [kW]8, 87
Nominal heating capacity at A7/W27 2) [kW]3.21
Nominal heating capacity at A2/W35 1) [kW]7, 01
Nominal heating capacity at A2/W30 2) [kW]3.75
Nominal heating capacity at A-7/W35 1) [kW]4.95
Nominal heating capacity at A-7/W34 2) [kW]5.72
COP at A7/W35° 1) 4.68
COP at A7/W27° 2) 6.22
COP at A2/W35 1)4, 06
COP at A2/W30° 2) 4.44
COP at A-7/W35° 1)3.01
COP at A-7/W34° 2) 3.16
Cooling capacity A35/W7 KW/EER 1)5.5/3.09
Nominal heating volume flow [m³/h]1.35
Max. heating water flow temp. [°C]60
Max. Max. pressure loss heating system [kPa]80
Refrigerant/base charge [-/kg]R 32 / 1.4
GWP value 675
CO² equivalent [t] 0.41
Voltage supply comp. IM [V/~/Hz]230V/1~/50
Power supply Smart Control IM [V/~/Hz]230/1/50
Power supply E-heating element IM [V/~/Hz] 400V/3~/50
Nominal power consumption (A7/W35) [kW]1.89
Nominal current consumption (A7/W35) [A]8, 21
Sound power level AM LpA nominal [dB(A)]58
Sound pressure level nominal AM LpA [dB(A)] 3)31
Sound power level AM LpA night [dB(A)]55
Sound pressure level AM night LpA [dB(A)] 3)30
Dimensions AM HxWxD [mm]850x1200x375
Outer module weight [kg]85, 00
1) COP = Coefficient Of Performance according to EN 14511, EER=Energy Efficiency Ratio according to EN 14511. VDE tested
2)COP = Coefficient Of Performance in accordance with EN 14825,
3) with semi-formal dispersion at 5m, A7/W35 measurement in accordance with DIN EN 12102
The appliances comply with the relevant EU regulations and are CE-marked in accordance with the applicable directives. T-1514446 265005 4026415187033 en ["de","en","it","nl","nl","fr","es","pl","pt","cs","da","sv"] https://www.toolteam.com/en-GB/remko-wkm-100-graphite-l-w-monobloc-heat-pump-265005-t-1514446-4026415187033?dc=GB&cu=EUR 2026-08-03 5659.33 United Kingdom GB DE 14
REMKO Smart-Control Touch
All functions of the heat pump and heating circuits can be set using the Smart Control touch display. The intuitive controller software with plain text menu and commissioning wizard makes installation, maintenance and integration of additional modules easier for the installer.
Control of one unmixed and one mixed heating circuit (floor or radiator) with different flow temperatures, DHW preparation and temperature control can be realised. The required I/O module is supplied in an attractive surface-mounted housing with cable entries. The 4.3’ touch display with WLAN function is supplied in a separate surface-mounted housing and can also be installed flexibly in other rooms. Dew point control is possible via a separately installed humidity/temperature sensor. This is required for temperature control, e.g. cooling via a floor circuit. We recommend installing an additional dew point monitor (Remko EDP no. 259070) when temperature control is activated via panel heating systems. Other functions included as standard
EVU contact, SG-Ready contacts, Smart Heating/Cooling function (variant 2B) (PV self-consumption), cooling active, cooling valve and pump control via a contact
Temperature control via max. 2 rooms. Humidity sensor via Modbus, three-stage heating element, bivalent operation / boiler activation, thermal and pulse-controlled circulation operation
Included in the standard scope of delivery:
Safety group with SIV, automatic air vent and pressure gauge for heating circuit
2 shut-off valves 1‘ for heating circuits
1 dirt filter 1’ for heating circuits
1 outdoor sensor,
1 immersion sensor (intended for DHW heating)
1 Smart Control
1 Smart Serv 6/9kW
Available as accessories:
Electr. Overflow valve 1”
Sludge separator
Air separator
Heat transfer medium with frost protection
Contact and immersion sensors for integrating additional system components
Storage systems
Smart Control cable remote control
Smart Count (heat meter)
Smart Serv (7.5 kW electric auxiliary heating incl. emergency heating operation)
Smart Web (Smart Control 6/9kWA) emergency heating operation)
Smart-Web (Internet access)
3-way changeover valve for domestic hot water preparation
Highly efficient heating circuit pump groups with/without mixer
Frost protection heating
Technical performance data:
Type designationREMKO WKM 100
Application range heating incl. DHW [kW] 6-9 kW
Application limit heating [°C] - 20 to +43
Heating output according to ErP 35/55°C [kW]6/6
Efficiency class (heating)A+++/A++
Annual energy consumption 35/55°C [kWh]3104/3971
Space heating energy efficiency eta s190/138
Nominal heating output at A7/W35 1) [kW]8, 87
Nominal heating capacity at A7/W27 2) [kW]3.21
Nominal heating capacity at A2/W35 1) [kW]7, 01
Nominal heating capacity at A2/W30 2) [kW]3.75
Nominal heating capacity at A-7/W35 1) [kW]4.95
Nominal heating capacity at A-7/W34 2) [kW]5.72
COP at A7/W35° 1) 4.68
COP at A7/W27° 2) 6.22
COP at A2/W35 1)4, 06
COP at A2/W30° 2) 4.44
COP at A-7/W35° 1)3.01
COP at A-7/W34° 2) 3.16
Cooling capacity A35/W7 KW/EER 1)5.5/3.09
Nominal heating volume flow [m³/h]1.35
Max. heating water flow temp. [°C]60
Max. Max. pressure loss heating system [kPa]80
Refrigerant/base charge [-/kg]R 32 / 1.4
GWP value 675
CO² equivalent [t] 0.41
Voltage supply comp. IM [V/~/Hz]230V/1~/50
Power supply Smart Control IM [V/~/Hz]230/1/50
Power supply E-heating element IM [V/~/Hz] 400V/3~/50
Nominal power consumption (A7/W35) [kW]1.89
Nominal current consumption (A7/W35) [A]8, 21
Sound power level AM LpA nominal [dB(A)]58
Sound pressure level nominal AM LpA [dB(A)] 3)31
Sound power level AM LpA night [dB(A)]55
Sound pressure level AM night LpA [dB(A)] 3)30
Dimensions AM HxWxD [mm]850x1200x375
Outer module weight [kg]85, 00
1) COP = Coefficient Of Performance according to EN 14511, EER=Energy Efficiency Ratio according to EN 14511. VDE tested
2)COP = Coefficient Of Performance in accordance with EN 14825,
3) with semi-formal dispersion at 5m, A7/W35 measurement in accordance with DIN EN 12102
The appliances comply with the relevant EU regulations and are CE-marked in accordance with the applicable directives. T-1514446 265005 4026415187033 en ["de","en","it","nl","nl","fr","es","pl","pt","cs","da","sv"] https://www.toolteam.com/en-GB/remko-wkm-100-graphite-l-w-monobloc-heat-pump-265005-t-1514446-4026415187033?dc=GB&cu=EUR 2026-08-03 5659.33 United Kingdom GB DE 14