zoom_in
zoom_out
fullscreen
Remko Stat. WLE PWL 301 HK, versatile in use 1688301
Sku: T-384836
Discontinued item
Product variants
| Sku: | Name: | SKU manufacturer: | ||
|---|---|---|---|---|
|
T-384819 | Stat. WLE PWL 101 H, versatile in use | 1687101 | |
|
T-384820 | Stat. WLE PWL 102 H, versatile in use | 1687102 | |
|
T-384821 | Stat. WLE PWL 103 H, versatile in use | 1687103 | |
|
T-384822 | Stat. WLE PWL 201 H, versatile in use | 1687201 | |
|
T-384823 | Stat. WLE PWL 202 H, versatile in use | 1687202 | |
|
T-384824 | Stat. WLE PWL 203 H, versatile in use | 1687203 | |
|
T-384825 | Stat. WLE PWL 301 H, versatile in use | 1687301 | |
|
T-384826 | Stat. WLE PWL 302 H, versatile in use | 1687302 | |
|
T-384827 | Stat. WLE PWL 303 H, versatile in use | 1687303 | |
|
T-384830 | Static WLE PWL 101 HK | 1688101 | |
|
T-384831 | Stat. WLE PWL 102 HK, versatile in use | 1688102 | |
|
T-384832 | Stat. WLE PWL 103 HK, versatile in use | 1688103 | |
|
T-384833 | Stat. WLE PWL 201 HK, versatile in use | 1688201 | |
|
T-384834 | Stat. WLE PWL 202 HK, versatile in use | 1688202 | |
|
T-384835 | Stat. WLE PWL 203 HK, versatile in use | 1688203 | |
|
T-384837 | Stat. WLE PWL 302 HK, versatile in use | 1688302 | |
|
T-384838 | Stat. WLE PWL 303 HK, versatile in use | 1688303 |
doneProduct group: 1406
doneType: STD
doneType: STD
doneMade in Germany
Remko Stat. WLE PWL 301 HK 1688301, versatile application
Product data
Manufacturer:
REMKO GmbH & Co. KG
Condition:
NEW
Sku:
T-384836
SKU manufacturer:
1688301
GTIN Code (EAN):
4026415110017
Weight:
60,80 Kg
All information relating to products from REMKO GmbH & Co. KG. Technical and optical modifications of the manufacturer and errors reserved.
This page has been machine-translated, the original german version can be found here, please also note the Translation Disclaimer.
Product description
Ceiling air unit for heating or cooling high and low rooms in recirculation mode.
The unit has been designed so that all necessary media connections can be installed out of sight in the false ceiling area. The appliance is characterised by its ease of servicing and simple, uncomplicated installation.
The PWL ceiling air unit consists of a high-quality plastic housing (colour similar to RAL 9010). The plastic housing complies with fire class V-0, the material is self-extinguishing in the event of fire.
The internal load-bearing structure is made of galvanised sheet steel and the plastic housing can be completely removed from the load-bearing structure using the quick-release fasteners. An integrated safety strap prevents the bonnet from falling down.
The heat exchanger is designed as a copper aluminium round heating/cooling battery. Mechanically welded copper tubes with profiled aluminium fins ensure optimum heat transfer. The 1’ connections with internal pipe thread are located in the non-visible area. Flow temperature max. 90°C Operating pressure up to max. 16 bar.
The axial fan is driven by a 2-speed, low-maintenance external fan motor (insulation class F). The motor is protected by thermal contacts.
The high-performance crescent impeller, together with the inlet nozzle, ensures low-noise operation for both directions of rotation.
An automatic condensate pump is fitted ready for connection to drain the condensate produced during cooling operation.
Individually adjustable louvres at the top and bottom of the appliance enable optimum air distribution.
The appliances comply with the relevant EU regulations and are CE-labelled in accordance with the applicable directives.
Technical performance data:
ManufacturerREMKO
TypePWL 301-HK
Performance dataStage II/I
Air flow rate per stage [m³/h]4300/2650
Nominal heating capacity 2) [kW]11.1/8.4
Air heating from 20°C to [°C]28/29
Heating mediumWW 70/50
Nominal cooling capacity 1) [kW]6, 3/5.0
Air cooling from 28°C to [°C]24/23
CoolantKW 6/10
Operating limits [°C]+10 to +35
Sound power level 3) [dB(A)]66/59
Voltage supply [V/~/Hz]400/3/50
Motor speed [rpm]920/750
Protection classIP 54
Elektr. Nominal power consumption [kW]0.36/0.22
Nominal electrical current consumption [A]0.84/0.46
Operating mediumWater, max. 35% glycol
Operating limits medium [°C]+4 to +90
Operating pressure, max, Medium [kPa]1600
Medium connections1”
Dimensions (H/W/D) [mm]504/1178/1160
Weight [kg]43.0
Serial colour similar to RAL 9010
1) Air inlet TK 28°C, 45% r.h., medium temperatures 6/10 °C, 0% glycol concentration
2) Air inlet 20°C, medium temperatures 70/50 °C, 0% glycol concentration
3) Distance 1m according to DIN 45635-01-KL 3
The unit has been designed so that all necessary media connections can be installed out of sight in the false ceiling area. The appliance is characterised by its ease of servicing and simple, uncomplicated installation.
The PWL ceiling air unit consists of a high-quality plastic housing (colour similar to RAL 9010). The plastic housing complies with fire class V-0, the material is self-extinguishing in the event of fire.
The internal load-bearing structure is made of galvanised sheet steel and the plastic housing can be completely removed from the load-bearing structure using the quick-release fasteners. An integrated safety strap prevents the bonnet from falling down.
The heat exchanger is designed as a copper aluminium round heating/cooling battery. Mechanically welded copper tubes with profiled aluminium fins ensure optimum heat transfer. The 1’ connections with internal pipe thread are located in the non-visible area. Flow temperature max. 90°C Operating pressure up to max. 16 bar.
The axial fan is driven by a 2-speed, low-maintenance external fan motor (insulation class F). The motor is protected by thermal contacts.
The high-performance crescent impeller, together with the inlet nozzle, ensures low-noise operation for both directions of rotation.
An automatic condensate pump is fitted ready for connection to drain the condensate produced during cooling operation.
Individually adjustable louvres at the top and bottom of the appliance enable optimum air distribution.
The appliances comply with the relevant EU regulations and are CE-labelled in accordance with the applicable directives.
Technical performance data:
ManufacturerREMKO
TypePWL 301-HK
Performance dataStage II/I
Air flow rate per stage [m³/h]4300/2650
Nominal heating capacity 2) [kW]11.1/8.4
Air heating from 20°C to [°C]28/29
Heating mediumWW 70/50
Nominal cooling capacity 1) [kW]6, 3/5.0
Air cooling from 28°C to [°C]24/23
CoolantKW 6/10
Operating limits [°C]+10 to +35
Sound power level 3) [dB(A)]66/59
Voltage supply [V/~/Hz]400/3/50
Motor speed [rpm]920/750
Protection classIP 54
Elektr. Nominal power consumption [kW]0.36/0.22
Nominal electrical current consumption [A]0.84/0.46
Operating mediumWater, max. 35% glycol
Operating limits medium [°C]+4 to +90
Operating pressure, max, Medium [kPa]1600
Medium connections1”
Dimensions (H/W/D) [mm]504/1178/1160
Weight [kg]43.0
Serial colour similar to RAL 9010
1) Air inlet TK 28°C, 45% r.h., medium temperatures 6/10 °C, 0% glycol concentration
2) Air inlet 20°C, medium temperatures 70/50 °C, 0% glycol concentration
3) Distance 1m according to DIN 45635-01-KL 3
Additional information
Product group:
1406
Width (mm):
1160.0MMT
Height (mm):
504.0MMT
Length (mm):
1178.0MMT
Type:
STD
Related results
Complete catalogs
The offer is aimed exclusively at business customers, companies, public institutions, tradesmen and freelancers. All prices in catalogues are exclusive of VAT, shipping costs and surcharges if applicable.
The manufacturer is exclusively responsible for the content, price and article details of the products and offers presented in the catalogues. Subject to technical and optical changes by the manufacturer and errors excepted.
The manufacturer is exclusively responsible for the content, price and article details of the products and offers presented in the catalogues. Subject to technical and optical changes by the manufacturer and errors excepted.
Matching catalog
Commercial customer offer**
Product suggestions
-4%
Quick coupling suction line BL 263/353 DC AT
1113540
€53.49
-4%
Side panel, left ATK 25
1103790
€45.50
-13%
Pressure regulator 1.5 bar/10 kg
1101663
€186.60
-4%
Support ring, 1-piece RK 25-50
1104168
€43.87
-19%
RK sound insulation hood SWK 4.1,
260938
€1,917.69
€2,360.00 MSRP
-19%
RK WP fresh water station
260181
€2,691.25
€3,312.01 MSRP
Accessory pack 1
1106445
€21.67
-13%
Outer sheath PGT 100
1101681
€227.48
-13%
Power board 954460 RVS
1106710
€128.53
-14%
ATY 267 Deco
1623430
€445.62
-10%
Injection nozzle No. 06 RVS 1600
1107332
€77.22
-4%
Insert (Vent. plug)
1108317
€33.95
-13%
Condensate drip tray KWK 450/600 (ZW)
1111783
€169.33
-14%
Heating circuit pump HGU/HGM Wilo Stratos PARA 25/1-7 T1
1120909
€372.61
-13%
Oil pump VM 1
1108498
€189.03
No Review yet
Description: No Review yet
Written by: No Review
Rating: 5 out of 5
5 stars, based on 1
reviews
Remko Stat. WLE PWL 301 HK, versatile in use 1688301
REMKO GmbH & Co. KG 1688301
Remko 1688301
1688301
4026415110017
Stationary warm air heating systems
Ceiling air unit for heating or cooling high and low rooms in recirculation mode.
The unit has been designed so that all necessary media connections can be installed out of sight in the false ceiling area. The appliance is characterised by its ease of servicing and simple, uncomplicated installation.
The PWL ceiling air unit consists of a high-quality plastic housing (colour similar to RAL 9010). The plastic housing complies with fire class V-0, the material is self-extinguishing in the event of fire.
The internal load-bearing structure is made of galvanised sheet steel and the plastic housing can be completely removed from the load-bearing structure using the quick-release fasteners. An integrated safety strap prevents the bonnet from falling down.
The heat exchanger is designed as a copper aluminium round heating/cooling battery. Mechanically welded copper tubes with profiled aluminium fins ensure optimum heat transfer. The 1’ connections with internal pipe thread are located in the non-visible area. Flow temperature max. 90°C Operating pressure up to max. 16 bar.
The axial fan is driven by a 2-speed, low-maintenance external fan motor (insulation class F). The motor is protected by thermal contacts.
The high-performance crescent impeller, together with the inlet nozzle, ensures low-noise operation for both directions of rotation.
An automatic condensate pump is fitted ready for connection to drain the condensate produced during cooling operation.
Individually adjustable louvres at the top and bottom of the appliance enable optimum air distribution.
The appliances comply with the relevant EU regulations and are CE-labelled in accordance with the applicable directives.
Technical performance data:
ManufacturerREMKO
TypePWL 301-HK
Performance dataStage II/I
Air flow rate per stage [m³/h]4300/2650
Nominal heating capacity 2) [kW]11.1/8.4
Air heating from 20°C to [°C]28/29
Heating mediumWW 70/50
Nominal cooling capacity 1) [kW]6, 3/5.0
Air cooling from 28°C to [°C]24/23
CoolantKW 6/10
Operating limits [°C]+10 to +35
Sound power level 3) [dB(A)]66/59
Voltage supply [V/~/Hz]400/3/50
Motor speed [rpm]920/750
Protection classIP 54
Elektr. Nominal power consumption [kW]0.36/0.22
Nominal electrical current consumption [A]0.84/0.46
Operating mediumWater, max. 35% glycol
Operating limits medium [°C]+4 to +90
Operating pressure, max, Medium [kPa]1600
Medium connections1”
Dimensions (H/W/D) [mm]504/1178/1160
Weight [kg]43.0
Serial colour similar to RAL 9010
1) Air inlet TK 28°C, 45% r.h., medium temperatures 6/10 °C, 0% glycol concentration
2) Air inlet 20°C, medium temperatures 70/50 °C, 0% glycol concentration
3) Distance 1m according to DIN 45635-01-KL 3 T-384836 1688301 4026415110017 en ["de","en","it","nl","nl","fr","es","pl","pt","cs","da","sv"] https://www.toolteam.com/en-GB/remko-stat-wle-pwl-301-hk-versatile-in-use-1688301-t-384836-4026415110017?dc=GB&cu=EUR 2026-07-14 3231.59 United Kingdom GB DE 14
The unit has been designed so that all necessary media connections can be installed out of sight in the false ceiling area. The appliance is characterised by its ease of servicing and simple, uncomplicated installation.
The PWL ceiling air unit consists of a high-quality plastic housing (colour similar to RAL 9010). The plastic housing complies with fire class V-0, the material is self-extinguishing in the event of fire.
The internal load-bearing structure is made of galvanised sheet steel and the plastic housing can be completely removed from the load-bearing structure using the quick-release fasteners. An integrated safety strap prevents the bonnet from falling down.
The heat exchanger is designed as a copper aluminium round heating/cooling battery. Mechanically welded copper tubes with profiled aluminium fins ensure optimum heat transfer. The 1’ connections with internal pipe thread are located in the non-visible area. Flow temperature max. 90°C Operating pressure up to max. 16 bar.
The axial fan is driven by a 2-speed, low-maintenance external fan motor (insulation class F). The motor is protected by thermal contacts.
The high-performance crescent impeller, together with the inlet nozzle, ensures low-noise operation for both directions of rotation.
An automatic condensate pump is fitted ready for connection to drain the condensate produced during cooling operation.
Individually adjustable louvres at the top and bottom of the appliance enable optimum air distribution.
The appliances comply with the relevant EU regulations and are CE-labelled in accordance with the applicable directives.
Technical performance data:
ManufacturerREMKO
TypePWL 301-HK
Performance dataStage II/I
Air flow rate per stage [m³/h]4300/2650
Nominal heating capacity 2) [kW]11.1/8.4
Air heating from 20°C to [°C]28/29
Heating mediumWW 70/50
Nominal cooling capacity 1) [kW]6, 3/5.0
Air cooling from 28°C to [°C]24/23
CoolantKW 6/10
Operating limits [°C]+10 to +35
Sound power level 3) [dB(A)]66/59
Voltage supply [V/~/Hz]400/3/50
Motor speed [rpm]920/750
Protection classIP 54
Elektr. Nominal power consumption [kW]0.36/0.22
Nominal electrical current consumption [A]0.84/0.46
Operating mediumWater, max. 35% glycol
Operating limits medium [°C]+4 to +90
Operating pressure, max, Medium [kPa]1600
Medium connections1”
Dimensions (H/W/D) [mm]504/1178/1160
Weight [kg]43.0
Serial colour similar to RAL 9010
1) Air inlet TK 28°C, 45% r.h., medium temperatures 6/10 °C, 0% glycol concentration
2) Air inlet 20°C, medium temperatures 70/50 °C, 0% glycol concentration
3) Distance 1m according to DIN 45635-01-KL 3 T-384836 1688301 4026415110017 en ["de","en","it","nl","nl","fr","es","pl","pt","cs","da","sv"] https://www.toolteam.com/en-GB/remko-stat-wle-pwl-301-hk-versatile-in-use-1688301-t-384836-4026415110017?dc=GB&cu=EUR 2026-07-14 3231.59 United Kingdom GB DE 14