zoom_in
zoom_out
fullscreen
Remko Room climate control unit MVV 2000 DC 1623610
Sku: T-384091
Discontinued item
Product variants
| Sku: | Name: | SKU manufacturer: | ||
|---|---|---|---|---|
|
T-384089 | Room climate control unit MVV 1200 DC | 1623600 | |
|
T-384090 | Room climate control unit MVV 1600 DC | 1623605 | |
|
T-384092 | Room climate control unit MVV 1200 DC DUO | 1623615 | |
|
T-384093 | Room climate control unit MVV 1600 DC DUO | 1623620 | |
|
T-384094 | Room climate control unit MVV 2000 DC DUO | 1623625 |
doneProduct group: 2804
doneDepth: 415mm
doneDepth: 415mm
doneType: STD
Remko MVV 2000 DC room air conditioner 1623610
Product data
Manufacturer:
REMKO GmbH & Co. KG
Condition:
NEW
Sku:
T-384091
SKU manufacturer:
1623610
GTIN Code (EAN):
4026415112943
Weight:
147,00 Kg
All information relating to products from REMKO GmbH & Co. KG. Technical and optical modifications of the manufacturer and errors reserved.
This page has been machine-translated, the original german version can be found here, please also note the Translation Disclaimer.
Product description
Inverter multisplit VRF outdoor unit for direct evaporation for floor or wall mounting. Outdoor unit for cooling and heating for connecting one to seven indoor units as wall or ceiling cassette units. The outdoor units are zipped for connecting the indoor units with a min/max. cooling connection capacity of 50% to 130%.
Casing of the outdoor unit made of galvanised sheet steel with weatherproof protective coating (similar to RAL 9002). The air inlet is via a high-performance condenser made of seamless drawn copper pipe in refrigerator quality with form-fit aluminium fins with protection against external influences by grilles. Two smooth-running, two-stage DC axial fans, statically and dynamically balanced, with thermally protected drive motor. The air inlet is via the condenser. Refrigeration circuit with a powerful, low-noise and vibration-damped scroll compressor with combined overcurrent/thermal protection device. Electronics with control components to generate a compressor output of 9.23 kW to 21.53 kW cooling capacity and 10.52 to 25.43 kW heating capacity. Shut-off devices on the suction and pressure side for the liquid and suction lines inside the appliance with Schrader valves. An integrated four-way reversing valve for switching between cooling and heating mode. A separate electronic expansion valve is installed for effective heating operation. Refrigerant circuit pre-charged with R 410 A. refrigerant. The integrated refrigerant collector ensures a permanent supply of refrigerant to the indoor units. The oil supply to the compressor is realised via a built-in oil separator and kept at a minimum temperature by an electric heating element. Electrical connection compartment for the separate mains supply line and the outdoor unit. The control line to the indoor units is via a looped bus line. Two-digit display for reading the current operating status is integrated on the circuit board.
The regional regulations, ordinances or environmental protection laws, e.g. WHG, must be observed when planning and installing the appliances.
The appliances comply with the relevant EU regulations and are CE-labelled in accordance with the applicable directives.
Included in the standard scope of delivery:
Condenser protection grille
Scroll compressor
Electronic expansion valve
Oil separator
Refrigerant collector
Display for reading the operating status
Available as accessories:
Indoor units MVW (wall), MVD (ceiling cassette)
Centralised control for up to 64 indoor units
Wall or floor consoles
Refrigerant lines
Technical performance data:
MakeREMKO
TypeMVV 2000 DC
Nominal cooling capacity 1) 5) [kW]20.00 (9.23-21.53)
Nominal heating capacity 2) 5) [kW]23.30 (10.52-25.43)
Number of outdoor units1
Max. Number of indoor units per AT10
Max. Cooling connection capacity indoor units [kW]26
Min. Cooling connection capacity indoor units [kW]11
Energy efficiency class K/H 5)B / A
Energy efficiency parameter EER / COP 5)3.03 / 3.77
Energy consumption, annual, 500h K/H 5) [kWh]3295 / 3090
Working range, Outdoor unit cooling [°C]-15 to +48
Working range, outdoor unit heating [°C]-15 to +27
Refrigerant /GWP 4)R 410 A
Refrigerant base charge ]kg]4.8
Air flow max. [m³/h]10800
Sound power level 3) [dB(A)]70
Sound pressure level outdoor unit, max. 3) [dB(A)]59
Voltage supply [V/~/Hz]400/3/50
Protection classIP 24
Electr. Rated power consumption cooling 1) 5) [kW]6.59
Rated electrical power consumption cooling 1) 5) [A]13.80
Rated electrical power consumption heating 2) 5) [kW]6.18
Rated electrical power consumption heating 2) 5) [A]10.90
Max. Nominal power consumption [kW]8.70
Max. Nominal current consumption [A]15
Refrigerant connections, injection/suction line3/8‘ / 3/4’
Length FL. line max. [m]100
Height diff. bottom IG. IG to top IG [m]8
Height diff. Between AT top to IG [m]30
Height diff. Between AT bottom to IG [m]20
Length manifold to IG max. [m]20
AT to furthest IG [m]60
Dimensions outdoor unit (H/W/D) [mm]1560/1120/415
Weight [kg]137.0
1) Room temperature TK 27 °C, FK 19 °C, max. air volume flow outdoor temperature TK 35 °C, max. air volume flow outdoor temperature TK 35 °C, max. air volume flow outdoor temperature TK 35 °C. Air volume flow outdoor temperature TK 35 °C, FK 24 °C
2) room temperature TK 20 °C, FK 14 °C, max. air volume flow outdoor temperature TK 7 °C, FK 6 °C
3) distance 1m/5m free field, per outdoor unit
4) contains greenhouse gas according to Kyoto Protocol, GWP calculated according to VO 842/2006
5) in combination with 5x MVW 220 2x MVW 450
Casing of the outdoor unit made of galvanised sheet steel with weatherproof protective coating (similar to RAL 9002). The air inlet is via a high-performance condenser made of seamless drawn copper pipe in refrigerator quality with form-fit aluminium fins with protection against external influences by grilles. Two smooth-running, two-stage DC axial fans, statically and dynamically balanced, with thermally protected drive motor. The air inlet is via the condenser. Refrigeration circuit with a powerful, low-noise and vibration-damped scroll compressor with combined overcurrent/thermal protection device. Electronics with control components to generate a compressor output of 9.23 kW to 21.53 kW cooling capacity and 10.52 to 25.43 kW heating capacity. Shut-off devices on the suction and pressure side for the liquid and suction lines inside the appliance with Schrader valves. An integrated four-way reversing valve for switching between cooling and heating mode. A separate electronic expansion valve is installed for effective heating operation. Refrigerant circuit pre-charged with R 410 A. refrigerant. The integrated refrigerant collector ensures a permanent supply of refrigerant to the indoor units. The oil supply to the compressor is realised via a built-in oil separator and kept at a minimum temperature by an electric heating element. Electrical connection compartment for the separate mains supply line and the outdoor unit. The control line to the indoor units is via a looped bus line. Two-digit display for reading the current operating status is integrated on the circuit board.
The regional regulations, ordinances or environmental protection laws, e.g. WHG, must be observed when planning and installing the appliances.
The appliances comply with the relevant EU regulations and are CE-labelled in accordance with the applicable directives.
Included in the standard scope of delivery:
Condenser protection grille
Scroll compressor
Electronic expansion valve
Oil separator
Refrigerant collector
Display for reading the operating status
Available as accessories:
Indoor units MVW (wall), MVD (ceiling cassette)
Centralised control for up to 64 indoor units
Wall or floor consoles
Refrigerant lines
Technical performance data:
MakeREMKO
TypeMVV 2000 DC
Nominal cooling capacity 1) 5) [kW]20.00 (9.23-21.53)
Nominal heating capacity 2) 5) [kW]23.30 (10.52-25.43)
Number of outdoor units1
Max. Number of indoor units per AT10
Max. Cooling connection capacity indoor units [kW]26
Min. Cooling connection capacity indoor units [kW]11
Energy efficiency class K/H 5)B / A
Energy efficiency parameter EER / COP 5)3.03 / 3.77
Energy consumption, annual, 500h K/H 5) [kWh]3295 / 3090
Working range, Outdoor unit cooling [°C]-15 to +48
Working range, outdoor unit heating [°C]-15 to +27
Refrigerant /GWP 4)R 410 A
Refrigerant base charge ]kg]4.8
Air flow max. [m³/h]10800
Sound power level 3) [dB(A)]70
Sound pressure level outdoor unit, max. 3) [dB(A)]59
Voltage supply [V/~/Hz]400/3/50
Protection classIP 24
Electr. Rated power consumption cooling 1) 5) [kW]6.59
Rated electrical power consumption cooling 1) 5) [A]13.80
Rated electrical power consumption heating 2) 5) [kW]6.18
Rated electrical power consumption heating 2) 5) [A]10.90
Max. Nominal power consumption [kW]8.70
Max. Nominal current consumption [A]15
Refrigerant connections, injection/suction line3/8‘ / 3/4’
Length FL. line max. [m]100
Height diff. bottom IG. IG to top IG [m]8
Height diff. Between AT top to IG [m]30
Height diff. Between AT bottom to IG [m]20
Length manifold to IG max. [m]20
AT to furthest IG [m]60
Dimensions outdoor unit (H/W/D) [mm]1560/1120/415
Weight [kg]137.0
1) Room temperature TK 27 °C, FK 19 °C, max. air volume flow outdoor temperature TK 35 °C, max. air volume flow outdoor temperature TK 35 °C, max. air volume flow outdoor temperature TK 35 °C. Air volume flow outdoor temperature TK 35 °C, FK 24 °C
2) room temperature TK 20 °C, FK 14 °C, max. air volume flow outdoor temperature TK 7 °C, FK 6 °C
3) distance 1m/5m free field, per outdoor unit
4) contains greenhouse gas according to Kyoto Protocol, GWP calculated according to VO 842/2006
5) in combination with 5x MVW 220 2x MVW 450
Additional information
Product group:
2804
Depth:
415mm
Width (mm):
1120.0MMT
Height (mm):
1560.0MMT
Length (mm):
415.0MMT
Type:
STD
Related results
Complete catalogs
The offer is aimed exclusively at business customers, companies, public institutions, tradesmen and freelancers. All prices in catalogues are exclusive of VAT, shipping costs and surcharges if applicable.
The manufacturer is exclusively responsible for the content, price and article details of the products and offers presented in the catalogues. Subject to technical and optical changes by the manufacturer and errors excepted.
The manufacturer is exclusively responsible for the content, price and article details of the products and offers presented in the catalogues. Subject to technical and optical changes by the manufacturer and errors excepted.
Matching catalog
Commercial customer offer**
Product suggestions
-14%
Heating circuit pump HGU/HGM Wilo Stratos PARA 25/1-7 T1
1120909
€372.61
-14%
ATY 357 Deco
1623432
€531.30
Mounting plate shut-off valve RVT 263 DC AT
1112422
€15.25
Condensate nozzle with plug MKT 240/250
1106882
€10.17
-4%
Support ring, 1-piece RK 25-50
1104168
€43.87
-10%
Reversing valve RXT 681 DC AT
1111598
€73.78
RK Netzstecker
1123916
€12.82
-4%
Side panel, left ATK 25
1103790
€45.50
-13%
Oil pump VM 1
1108498
€189.03
Whirler WKL/VRS 50-60
1102954
€22.14
-19%
RK sound insulation hood SWK 5.1,
260939
€2,015.21
€2,480.00 MSRP
Fan blade 200/31 DZH 20-2
1111663
€25.00
Oil nozzle 1.75/80 size S DZH 90
1107372
€25.00
Condensate nozzle RVD 684/MVD 701-1001
1114421
€9.20
Accessory pack 1
1106445
€21.67
No Review yet
Description: No Review yet
Written by: No Review
Rating: 5 out of 5
5 stars, based on 1
reviews
Remko Room climate control unit MVV 2000 DC 1623610
REMKO GmbH & Co. KG 1623610
Remko 1623610
1623610
4026415112943
VRF multi-climate systems
Inverter multisplit VRF outdoor unit for direct evaporation for floor or wall mounting. Outdoor unit for cooling and heating for connecting one to seven indoor units as wall or ceiling cassette units. The outdoor units are zipped for connecting the indoor units with a min/max. cooling connection capacity of 50% to 130%.
Casing of the outdoor unit made of galvanised sheet steel with weatherproof protective coating (similar to RAL 9002). The air inlet is via a high-performance condenser made of seamless drawn copper pipe in refrigerator quality with form-fit aluminium fins with protection against external influences by grilles. Two smooth-running, two-stage DC axial fans, statically and dynamically balanced, with thermally protected drive motor. The air inlet is via the condenser. Refrigeration circuit with a powerful, low-noise and vibration-damped scroll compressor with combined overcurrent/thermal protection device. Electronics with control components to generate a compressor output of 9.23 kW to 21.53 kW cooling capacity and 10.52 to 25.43 kW heating capacity. Shut-off devices on the suction and pressure side for the liquid and suction lines inside the appliance with Schrader valves. An integrated four-way reversing valve for switching between cooling and heating mode. A separate electronic expansion valve is installed for effective heating operation. Refrigerant circuit pre-charged with R 410 A. refrigerant. The integrated refrigerant collector ensures a permanent supply of refrigerant to the indoor units. The oil supply to the compressor is realised via a built-in oil separator and kept at a minimum temperature by an electric heating element. Electrical connection compartment for the separate mains supply line and the outdoor unit. The control line to the indoor units is via a looped bus line. Two-digit display for reading the current operating status is integrated on the circuit board.
The regional regulations, ordinances or environmental protection laws, e.g. WHG, must be observed when planning and installing the appliances.
The appliances comply with the relevant EU regulations and are CE-labelled in accordance with the applicable directives.
Included in the standard scope of delivery:
Condenser protection grille
Scroll compressor
Electronic expansion valve
Oil separator
Refrigerant collector
Display for reading the operating status
Available as accessories:
Indoor units MVW (wall), MVD (ceiling cassette)
Centralised control for up to 64 indoor units
Wall or floor consoles
Refrigerant lines
Technical performance data:
MakeREMKO
TypeMVV 2000 DC
Nominal cooling capacity 1) 5) [kW]20.00 (9.23-21.53)
Nominal heating capacity 2) 5) [kW]23.30 (10.52-25.43)
Number of outdoor units1
Max. Number of indoor units per AT10
Max. Cooling connection capacity indoor units [kW]26
Min. Cooling connection capacity indoor units [kW]11
Energy efficiency class K/H 5)B / A
Energy efficiency parameter EER / COP 5)3.03 / 3.77
Energy consumption, annual, 500h K/H 5) [kWh]3295 / 3090
Working range, Outdoor unit cooling [°C]-15 to +48
Working range, outdoor unit heating [°C]-15 to +27
Refrigerant /GWP 4)R 410 A
Refrigerant base charge ]kg]4.8
Air flow max. [m³/h]10800
Sound power level 3) [dB(A)]70
Sound pressure level outdoor unit, max. 3) [dB(A)]59
Voltage supply [V/~/Hz]400/3/50
Protection classIP 24
Electr. Rated power consumption cooling 1) 5) [kW]6.59
Rated electrical power consumption cooling 1) 5) [A]13.80
Rated electrical power consumption heating 2) 5) [kW]6.18
Rated electrical power consumption heating 2) 5) [A]10.90
Max. Nominal power consumption [kW]8.70
Max. Nominal current consumption [A]15
Refrigerant connections, injection/suction line3/8‘ / 3/4’
Length FL. line max. [m]100
Height diff. bottom IG. IG to top IG [m]8
Height diff. Between AT top to IG [m]30
Height diff. Between AT bottom to IG [m]20
Length manifold to IG max. [m]20
AT to furthest IG [m]60
Dimensions outdoor unit (H/W/D) [mm]1560/1120/415
Weight [kg]137.0
1) Room temperature TK 27 °C, FK 19 °C, max. air volume flow outdoor temperature TK 35 °C, max. air volume flow outdoor temperature TK 35 °C, max. air volume flow outdoor temperature TK 35 °C. Air volume flow outdoor temperature TK 35 °C, FK 24 °C
2) room temperature TK 20 °C, FK 14 °C, max. air volume flow outdoor temperature TK 7 °C, FK 6 °C
3) distance 1m/5m free field, per outdoor unit
4) contains greenhouse gas according to Kyoto Protocol, GWP calculated according to VO 842/2006
5) in combination with 5x MVW 220 2x MVW 450 T-384091 1623610 4026415112943 en ["de","en","it","nl","nl","fr","es","pl","pt","cs","da","sv"] https://www.toolteam.com/en-GB/remko-room-climate-control-unit-mvv-2000-dc-1623610-t-384091-4026415112943?dc=GB&cu=EUR 2026-08-08 7470.83 United Kingdom GB DE 14
Casing of the outdoor unit made of galvanised sheet steel with weatherproof protective coating (similar to RAL 9002). The air inlet is via a high-performance condenser made of seamless drawn copper pipe in refrigerator quality with form-fit aluminium fins with protection against external influences by grilles. Two smooth-running, two-stage DC axial fans, statically and dynamically balanced, with thermally protected drive motor. The air inlet is via the condenser. Refrigeration circuit with a powerful, low-noise and vibration-damped scroll compressor with combined overcurrent/thermal protection device. Electronics with control components to generate a compressor output of 9.23 kW to 21.53 kW cooling capacity and 10.52 to 25.43 kW heating capacity. Shut-off devices on the suction and pressure side for the liquid and suction lines inside the appliance with Schrader valves. An integrated four-way reversing valve for switching between cooling and heating mode. A separate electronic expansion valve is installed for effective heating operation. Refrigerant circuit pre-charged with R 410 A. refrigerant. The integrated refrigerant collector ensures a permanent supply of refrigerant to the indoor units. The oil supply to the compressor is realised via a built-in oil separator and kept at a minimum temperature by an electric heating element. Electrical connection compartment for the separate mains supply line and the outdoor unit. The control line to the indoor units is via a looped bus line. Two-digit display for reading the current operating status is integrated on the circuit board.
The regional regulations, ordinances or environmental protection laws, e.g. WHG, must be observed when planning and installing the appliances.
The appliances comply with the relevant EU regulations and are CE-labelled in accordance with the applicable directives.
Included in the standard scope of delivery:
Condenser protection grille
Scroll compressor
Electronic expansion valve
Oil separator
Refrigerant collector
Display for reading the operating status
Available as accessories:
Indoor units MVW (wall), MVD (ceiling cassette)
Centralised control for up to 64 indoor units
Wall or floor consoles
Refrigerant lines
Technical performance data:
MakeREMKO
TypeMVV 2000 DC
Nominal cooling capacity 1) 5) [kW]20.00 (9.23-21.53)
Nominal heating capacity 2) 5) [kW]23.30 (10.52-25.43)
Number of outdoor units1
Max. Number of indoor units per AT10
Max. Cooling connection capacity indoor units [kW]26
Min. Cooling connection capacity indoor units [kW]11
Energy efficiency class K/H 5)B / A
Energy efficiency parameter EER / COP 5)3.03 / 3.77
Energy consumption, annual, 500h K/H 5) [kWh]3295 / 3090
Working range, Outdoor unit cooling [°C]-15 to +48
Working range, outdoor unit heating [°C]-15 to +27
Refrigerant /GWP 4)R 410 A
Refrigerant base charge ]kg]4.8
Air flow max. [m³/h]10800
Sound power level 3) [dB(A)]70
Sound pressure level outdoor unit, max. 3) [dB(A)]59
Voltage supply [V/~/Hz]400/3/50
Protection classIP 24
Electr. Rated power consumption cooling 1) 5) [kW]6.59
Rated electrical power consumption cooling 1) 5) [A]13.80
Rated electrical power consumption heating 2) 5) [kW]6.18
Rated electrical power consumption heating 2) 5) [A]10.90
Max. Nominal power consumption [kW]8.70
Max. Nominal current consumption [A]15
Refrigerant connections, injection/suction line3/8‘ / 3/4’
Length FL. line max. [m]100
Height diff. bottom IG. IG to top IG [m]8
Height diff. Between AT top to IG [m]30
Height diff. Between AT bottom to IG [m]20
Length manifold to IG max. [m]20
AT to furthest IG [m]60
Dimensions outdoor unit (H/W/D) [mm]1560/1120/415
Weight [kg]137.0
1) Room temperature TK 27 °C, FK 19 °C, max. air volume flow outdoor temperature TK 35 °C, max. air volume flow outdoor temperature TK 35 °C, max. air volume flow outdoor temperature TK 35 °C. Air volume flow outdoor temperature TK 35 °C, FK 24 °C
2) room temperature TK 20 °C, FK 14 °C, max. air volume flow outdoor temperature TK 7 °C, FK 6 °C
3) distance 1m/5m free field, per outdoor unit
4) contains greenhouse gas according to Kyoto Protocol, GWP calculated according to VO 842/2006
5) in combination with 5x MVW 220 2x MVW 450 T-384091 1623610 4026415112943 en ["de","en","it","nl","nl","fr","es","pl","pt","cs","da","sv"] https://www.toolteam.com/en-GB/remko-room-climate-control-unit-mvv-2000-dc-1623610-t-384091-4026415112943?dc=GB&cu=EUR 2026-08-08 7470.83 United Kingdom GB DE 14