zoom_in
zoom_out
fullscreen
-19%
Remko RK WP WKF 80 AM Graphite 264003
Sku: T-888809
€2,380.83 (excl. legal VAT, excl. Shipping)
€2,930.00 MSRP
In stock,ready for shipping
Package
doneProduct group: 4101
doneType: STD
doneType: STD
264003, versatile application
Content:
1 Package
Shipping:
€273.87 Versandservice to United Kingdom
plus €60.80 stock transfer surcharge

For orders from €1,000.00 order total plus €34.45 Customs MRN registration
Lieferung:
Provider:
Sales and delivery by ToolTeam Köln
Payment methods:
Returns:
Security:
Product data
Manufacturer:
REMKO GmbH & Co. KG
Condition:
NEW
Sku:
T-888809
SKU manufacturer:
264003
GTIN Code (EAN):
4026415167950
Weight:
81,00 Kg
All information relating to products from REMKO GmbH & Co. KG. Technical and optical modifications of the manufacturer and errors reserved.
This page has been machine-translated, the original german version can be found here, please also note the Translation Disclaimer.
Product description
Outdoor module WKF 80
Inverter-controlled outdoor module for heat absorption from the ambient air. Installation outdoors. Housing and frame are made of sturdy galvanised sheet steel with an additional weather-resistant polyester stove enamel finish and internal sound insulation. Large removable panelling elements. Colour RAL 9006/7021
Available as accessories:
Refrigerant lines
Floor or wall bracket for outdoor module
Condensate drip tray without/with oil separator
Electric condensate drain heater
Environmental protection regulations and laws must be observed.
Technical performance data:
Type designationREMKO WKF 80 AM
Heating output [kW]0.9-7.5
Space heating energy efficiency Average 35/55 [%]211/140
Efficiency class (heating)A++/A++
Heating application limits [°C]-20 to +37
Flow temperature heating water max. [°C]60
Nominal heating output for A12/W35 1) [kW]7.4
Nominal heating output for A7/W35 1) [kW]6.4
Nominal heating output for A2/W35 1) [kW]5.3
Nominal heating output for A-7/W35 1) [kW]4.2
Nominal heating output for A-15/W35 1) [kW]3, 2
COP at A12/W35/HZ 1) 5.92/79
COP at A7/W35/HZ 1) 5.92/79
COP at A2/W35/HZ 1) 4.13/79
COP at A-7/W35/HZ 1) 3.50/79
COP at A-15/W35°/HZ 1) 2.71/79
Cooling application limits [°C]+15 to +43
Flow temperature of cooling water min. [°C]7
Cooling capacity [kW]0.8-6.5
Cooling capacity A35/W7 KW/EER 2)4.50/2.7
Cooling capacity A35/W18 KW/EER 2)7.45/4.05
RefrigerantR32
Refrigerant quantity [kg]1, 0
additional filling quantity from 5m single length [g/m]30
Refrigerant connections1/4‘ / 1/2’
Refrigerant line, length max. [m]20.0
Height difference refrigerant line, max. [m]10.0
Voltage supply AM [V/~/Hz]230/1/50
Max. Current consumption [A]13.0
Nominal current consumption (A7/W35) [A]5.40
Nominal power consumption (A7/W35) [kW]1.24
Nominal power consumption (A2/W35) [kW]1.28
Max. Power consumption [kW]3.0
Nominal water volume flow [m³/h]1.1
External pressure loss [kPa]80.0
Air volume flow outdoor unit, max. [m³/h]2. 500
Sound power level outdoor unit LwA [dB(A)]54.9
Sound pressure level outdoor unit 3) 5m [dB(A)]29.9
Dimensions (H/W/D) [mm]700/1010/370
Weight outdoor unit [kg]62.0
1) COP = Coefficient Of Performance according to EN 14511, TÜV tested
2) EER = Energy Efficiency Ratio in accordance with EN 14511
3) with full spherical dispersion, A7/W55 measurement in accordance with DIN EN 12102 and DIN EN ISO 9614-2
The appliances comply with the relevant EU regulations and are CE labelled in accordance with the applicable directives. The appliances have been tested by TÜV Süd.
Inverter-controlled outdoor module for heat absorption from the ambient air. Installation outdoors. Housing and frame are made of sturdy galvanised sheet steel with an additional weather-resistant polyester stove enamel finish and internal sound insulation. Large removable panelling elements. Colour RAL 9006/7021
Available as accessories:
Refrigerant lines
Floor or wall bracket for outdoor module
Condensate drip tray without/with oil separator
Electric condensate drain heater
Environmental protection regulations and laws must be observed.
Technical performance data:
Type designationREMKO WKF 80 AM
Heating output [kW]0.9-7.5
Space heating energy efficiency Average 35/55 [%]211/140
Efficiency class (heating)A++/A++
Heating application limits [°C]-20 to +37
Flow temperature heating water max. [°C]60
Nominal heating output for A12/W35 1) [kW]7.4
Nominal heating output for A7/W35 1) [kW]6.4
Nominal heating output for A2/W35 1) [kW]5.3
Nominal heating output for A-7/W35 1) [kW]4.2
Nominal heating output for A-15/W35 1) [kW]3, 2
COP at A12/W35/HZ 1) 5.92/79
COP at A7/W35/HZ 1) 5.92/79
COP at A2/W35/HZ 1) 4.13/79
COP at A-7/W35/HZ 1) 3.50/79
COP at A-15/W35°/HZ 1) 2.71/79
Cooling application limits [°C]+15 to +43
Flow temperature of cooling water min. [°C]7
Cooling capacity [kW]0.8-6.5
Cooling capacity A35/W7 KW/EER 2)4.50/2.7
Cooling capacity A35/W18 KW/EER 2)7.45/4.05
RefrigerantR32
Refrigerant quantity [kg]1, 0
additional filling quantity from 5m single length [g/m]30
Refrigerant connections1/4‘ / 1/2’
Refrigerant line, length max. [m]20.0
Height difference refrigerant line, max. [m]10.0
Voltage supply AM [V/~/Hz]230/1/50
Max. Current consumption [A]13.0
Nominal current consumption (A7/W35) [A]5.40
Nominal power consumption (A7/W35) [kW]1.24
Nominal power consumption (A2/W35) [kW]1.28
Max. Power consumption [kW]3.0
Nominal water volume flow [m³/h]1.1
External pressure loss [kPa]80.0
Air volume flow outdoor unit, max. [m³/h]2. 500
Sound power level outdoor unit LwA [dB(A)]54.9
Sound pressure level outdoor unit 3) 5m [dB(A)]29.9
Dimensions (H/W/D) [mm]700/1010/370
Weight outdoor unit [kg]62.0
1) COP = Coefficient Of Performance according to EN 14511, TÜV tested
2) EER = Energy Efficiency Ratio in accordance with EN 14511
3) with full spherical dispersion, A7/W55 measurement in accordance with DIN EN 12102 and DIN EN ISO 9614-2
The appliances comply with the relevant EU regulations and are CE labelled in accordance with the applicable directives. The appliances have been tested by TÜV Süd.
Additional information
Product group:
4101
Width (mm):
1010.0MMT
Height (mm):
700.0MMT
Length (mm):
370.0MMT
Type:
STD
Related results
Complete catalogs
The offer is aimed exclusively at business customers, companies, public institutions, tradesmen and freelancers. All prices in catalogues are exclusive of VAT, shipping costs and surcharges if applicable.
The manufacturer is exclusively responsible for the content, price and article details of the products and offers presented in the catalogues. Subject to technical and optical changes by the manufacturer and errors excepted.
The manufacturer is exclusively responsible for the content, price and article details of the products and offers presented in the catalogues. Subject to technical and optical changes by the manufacturer and errors excepted.
Matching catalog
Commercial customer offer**
Product suggestions
Fan blade 200/31 DZH 20-2
1111663
€25.00
-19%
ZA axial fan 501-4
1108376
€808.06
€994.41 MSRP
-14%
Relay board WP-Manager (WMZ version) CMT 120/160
1120194
€297.69
-4%
Quick coupling suction line BL 263/353 DC AT
1113540
€53.49
-10%
Reversing valve RXT 681 DC AT
1111598
€73.78
-10%
Injection nozzle No. 06 RVS 1600
1107332
€77.22
-4%
Condensate container ETF/AMT
1104429
€61.09
Silencer RK 70
1104117
€7.10
-13%
Power board 954460 RVS
1106710
€128.53
-19%
RK WP Fresh water station
260180
€1,830.67
€2,252.98 MSRP
Mounting plate shut-off valve RVT 263 DC AT
1112422
€15.25
-4%
Support ring, 1-piece RK 25-50
1104168
€43.87
Oil nozzle 1.75/80 size S DZH 90
1107372
€25.00
-13%
Oil pump VM 1
1108498
€189.03
-14%
Control board RVT 681 DC AT
1109849
€453.07
No Review yet
Description: No Review yet
Written by: No Review
Rating: 5 out of 5
5 stars, based on 1
reviews
Remko RK WP WKF 80 AM Graphite 264003
4026415167950
264003
REMKO GmbH & Co. KG
heating technology
air conditioning technology
room air conditioners
Outdoor module WKF 80
Inverter-controlled outdoor module for heat absorption from the ambient air. Installation outdoors. Housing and frame are made of sturdy galvanised sheet steel with an additional weather-resistant polyester stove enamel finish and internal sound insulation. Large removable panelling elements. Colour RAL 9006/7021
Available as accessories:
Refrigerant lines
Floor or wall bracket for outdoor module
Condensate drip tray without/with oil separator
Electric condensate drain heater
Environmental protection regulations and laws must be observed.
Technical performance data:
Type designationREMKO WKF 80 AM
Heating output [kW]0.9-7.5
Space heating energy efficiency Average 35/55 [%]211/140
Efficiency class (heating)A++/A++
Heating application limits [°C]-20 to +37
Flow temperature heating water max. [°C]60
Nominal heating output for A12/W35 1) [kW]7.4
Nominal heating output for A7/W35 1) [kW]6.4
Nominal heating output for A2/W35 1) [kW]5.3
Nominal heating output for A-7/W35 1) [kW]4.2
Nominal heating output for A-15/W35 1) [kW]3, 2
COP at A12/W35/HZ 1) 5.92/79
COP at A7/W35/HZ 1) 5.92/79
COP at A2/W35/HZ 1) 4.13/79
COP at A-7/W35/HZ 1) 3.50/79
COP at A-15/W35°/HZ 1) 2.71/79
Cooling application limits [°C]+15 to +43
Flow temperature of cooling water min. [°C]7
Cooling capacity [kW]0.8-6.5
Cooling capacity A35/W7 KW/EER 2)4.50/2.7
Cooling capacity A35/W18 KW/EER 2)7.45/4.05
RefrigerantR32
Refrigerant quantity [kg]1, 0
additional filling quantity from 5m single length [g/m]30
Refrigerant connections1/4‘ / 1/2’
Refrigerant line, length max. [m]20.0
Height difference refrigerant line, max. [m]10.0
Voltage supply AM [V/~/Hz]230/1/50
Max. Current consumption [A]13.0
Nominal current consumption (A7/W35) [A]5.40
Nominal power consumption (A7/W35) [kW]1.24
Nominal power consumption (A2/W35) [kW]1.28
Max. Power consumption [kW]3.0
Nominal water volume flow [m³/h]1.1
External pressure loss [kPa]80.0
Air volume flow outdoor unit, max. [m³/h]2. 500
Sound power level outdoor unit LwA [dB(A)]54.9
Sound pressure level outdoor unit 3) 5m [dB(A)]29.9
Dimensions (H/W/D) [mm]700/1010/370
Weight outdoor unit [kg]62.0
1) COP = Coefficient Of Performance according to EN 14511, TÜV tested
2) EER = Energy Efficiency Ratio in accordance with EN 14511
3) with full spherical dispersion, A7/W55 measurement in accordance with DIN EN 12102 and DIN EN ISO 9614-2
The appliances comply with the relevant EU regulations and are CE labelled in accordance with the applicable directives. The appliances have been tested by TÜV Süd. T-888809 264003 4026415167950 en ["de","en","it","nl","nl","fr","es","pl","pt","cs","da","sv"] https://www.toolteam.com/en-GB/remko-rk-wp-wkf-80-am-graphite-264003-t-888809-4026415167950?dc=GB&cu=EUR 2026-08-31 2380.83 United Kingdom GB DE 14
Inverter-controlled outdoor module for heat absorption from the ambient air. Installation outdoors. Housing and frame are made of sturdy galvanised sheet steel with an additional weather-resistant polyester stove enamel finish and internal sound insulation. Large removable panelling elements. Colour RAL 9006/7021
Available as accessories:
Refrigerant lines
Floor or wall bracket for outdoor module
Condensate drip tray without/with oil separator
Electric condensate drain heater
Environmental protection regulations and laws must be observed.
Technical performance data:
Type designationREMKO WKF 80 AM
Heating output [kW]0.9-7.5
Space heating energy efficiency Average 35/55 [%]211/140
Efficiency class (heating)A++/A++
Heating application limits [°C]-20 to +37
Flow temperature heating water max. [°C]60
Nominal heating output for A12/W35 1) [kW]7.4
Nominal heating output for A7/W35 1) [kW]6.4
Nominal heating output for A2/W35 1) [kW]5.3
Nominal heating output for A-7/W35 1) [kW]4.2
Nominal heating output for A-15/W35 1) [kW]3, 2
COP at A12/W35/HZ 1) 5.92/79
COP at A7/W35/HZ 1) 5.92/79
COP at A2/W35/HZ 1) 4.13/79
COP at A-7/W35/HZ 1) 3.50/79
COP at A-15/W35°/HZ 1) 2.71/79
Cooling application limits [°C]+15 to +43
Flow temperature of cooling water min. [°C]7
Cooling capacity [kW]0.8-6.5
Cooling capacity A35/W7 KW/EER 2)4.50/2.7
Cooling capacity A35/W18 KW/EER 2)7.45/4.05
RefrigerantR32
Refrigerant quantity [kg]1, 0
additional filling quantity from 5m single length [g/m]30
Refrigerant connections1/4‘ / 1/2’
Refrigerant line, length max. [m]20.0
Height difference refrigerant line, max. [m]10.0
Voltage supply AM [V/~/Hz]230/1/50
Max. Current consumption [A]13.0
Nominal current consumption (A7/W35) [A]5.40
Nominal power consumption (A7/W35) [kW]1.24
Nominal power consumption (A2/W35) [kW]1.28
Max. Power consumption [kW]3.0
Nominal water volume flow [m³/h]1.1
External pressure loss [kPa]80.0
Air volume flow outdoor unit, max. [m³/h]2. 500
Sound power level outdoor unit LwA [dB(A)]54.9
Sound pressure level outdoor unit 3) 5m [dB(A)]29.9
Dimensions (H/W/D) [mm]700/1010/370
Weight outdoor unit [kg]62.0
1) COP = Coefficient Of Performance according to EN 14511, TÜV tested
2) EER = Energy Efficiency Ratio in accordance with EN 14511
3) with full spherical dispersion, A7/W55 measurement in accordance with DIN EN 12102 and DIN EN ISO 9614-2
The appliances comply with the relevant EU regulations and are CE labelled in accordance with the applicable directives. The appliances have been tested by TÜV Süd. T-888809 264003 4026415167950 en ["de","en","it","nl","nl","fr","es","pl","pt","cs","da","sv"] https://www.toolteam.com/en-GB/remko-rk-wp-wkf-80-am-graphite-264003-t-888809-4026415167950?dc=GB&cu=EUR 2026-08-31 2380.83 United Kingdom GB DE 14