zoom_in
zoom_out
fullscreen
-19%
Remko RK WP WKF 130 Duo AM, versatile in use 264083
Sku: T-888825
€2,760.66 (excl. legal VAT, excl. Shipping)
(€1,380.33 / Piece)
€3,400.00 MSRP
In stock,ready for shipping within 24h
Carton
donegraphite
Graphite 264083
Content:
1 Carton = 2 Piece (€1,380.33 / Piece)
Shipping:
€273.87 Versandservice to United Kingdom
plus €70.50 stock transfer surcharge

For orders from €1,000.00 order total plus €34.45 Customs MRN registration
Lieferung:
Provider:
Sales and delivery by ToolTeam Köln
Payment methods:
Returns:
Security:
Product data
Manufacturer:
REMKO GmbH & Co. KG
Condition:
NEW
Sku:
T-888825
SKU manufacturer:
264083
GTIN Code (EAN):
4026415177836
Weight:
90,00 Kg
All information relating to products from REMKO GmbH & Co. KG. Technical and optical modifications of the manufacturer and errors reserved.
This page has been machine-translated, the original german version can be found here, please also note the Translation Disclaimer.
Product description
Outdoor module WKF 130
Inverter-controlled outdoor module for heat absorption from the ambient air. Outdoor installation. Housing and frame are made of sturdy galvanised sheet steel with an additional weather-resistant polyester stove enamel finish and internal sound insulation. Large removable panelling elements. Colour RAL 9006/7021
Available as accessories:
Refrigerant lines
Floor or wall bracket for outdoor module
Condensate drip tray without/with oil separator
Electric condensate drain heater
Environmental protection regulations and laws must be observed.
Technical performance data:
Type designationREMKO WKF 130 AM
Heating output [kW]2.0-12.5
Space heating energy efficiency Average 35/55 [%]XX/XX
Efficiency class (heating)A++/A++
Heating application limits [°C]-20 to +37
Flow temperature heating water max. [°C]60
Nominal heating output for A12/W35 1) [kW]12.0
Nominal heating output for A7/W35 1) [kW]10.3
Nominal heating output for A2/W35 1) [kW]8.7
Nominal heating output for A-7/W35 1) [kW]6.9
Nominal heating output for A-15/W35 1) [kW]5.1
COP for A12/W35/HZ 1) 5, 87/79
COP for A7/W35/HZ 1) 5.07/79
COP for A2/W35/HZ 1) 4.14/79
COP for A-7/W35/HZ 1) 3.47/79
COP for A-15/W35°/HZ 1) 2.69/79
Cooling application limits [°C]+15 to +43
Cooling capacity [kW]2.1-10.5
Flow temperature of cooling water min. [°C]7
Cooling capacity A35/W7 KW/EER 2)8.5/2.7
Cooling capacity A35/W18 KW/EER 2)9.8/3.9
RefrigerantR32
Refrigerant quantity [kg]1.8
Additional filling quantity from 5m single length [g/m]30
Refrigerant connections3/8‘ / 5/8’
Refrigerant line, length max. [m]20.0
Height difference refrigerant line, max. [m]10.0
Voltage supply AM [V/~/Hz]230/1/50
Max. Current consumption [A]18.0
Nominal current consumption (A7/W35) [A]8.85
Nominal power consumption (A7/W35) [kW]2.07
Nominal power consumption (A2/W35) [kW]2.10
Max. Power consumption [kW]4.1
Nominal water volume flow [m³/h]1.8
External pressure loss [kPa]70.0
Air volume flow outdoor unit, max. [m³/h]3. 350
Sound power level outdoor unit LwA [dB(A)]58.3
Sound pressure level outdoor unit 3) 5m [dB(A)]33.3
Dimensions (H/W/D) [mm]1165/845/370
Weight outdoor unit [kg]80.0
1) COP = Coefficient Of Performance according to EN 14511, TÜV tested
2) EER=Energy Efficiency Ratio according to EN 14511
3) with full spherical dispersion, A7/W55 measurement according to DIN EN 12102 and DIN EN ISO 9614-2
The appliances comply with the relevant EU regulations and are CE-marked in accordance with the applicable directives. The appliances have been tested by TÜV Süd.
Inverter-controlled outdoor module for heat absorption from the ambient air. Outdoor installation. Housing and frame are made of sturdy galvanised sheet steel with an additional weather-resistant polyester stove enamel finish and internal sound insulation. Large removable panelling elements. Colour RAL 9006/7021
Available as accessories:
Refrigerant lines
Floor or wall bracket for outdoor module
Condensate drip tray without/with oil separator
Electric condensate drain heater
Environmental protection regulations and laws must be observed.
Technical performance data:
Type designationREMKO WKF 130 AM
Heating output [kW]2.0-12.5
Space heating energy efficiency Average 35/55 [%]XX/XX
Efficiency class (heating)A++/A++
Heating application limits [°C]-20 to +37
Flow temperature heating water max. [°C]60
Nominal heating output for A12/W35 1) [kW]12.0
Nominal heating output for A7/W35 1) [kW]10.3
Nominal heating output for A2/W35 1) [kW]8.7
Nominal heating output for A-7/W35 1) [kW]6.9
Nominal heating output for A-15/W35 1) [kW]5.1
COP for A12/W35/HZ 1) 5, 87/79
COP for A7/W35/HZ 1) 5.07/79
COP for A2/W35/HZ 1) 4.14/79
COP for A-7/W35/HZ 1) 3.47/79
COP for A-15/W35°/HZ 1) 2.69/79
Cooling application limits [°C]+15 to +43
Cooling capacity [kW]2.1-10.5
Flow temperature of cooling water min. [°C]7
Cooling capacity A35/W7 KW/EER 2)8.5/2.7
Cooling capacity A35/W18 KW/EER 2)9.8/3.9
RefrigerantR32
Refrigerant quantity [kg]1.8
Additional filling quantity from 5m single length [g/m]30
Refrigerant connections3/8‘ / 5/8’
Refrigerant line, length max. [m]20.0
Height difference refrigerant line, max. [m]10.0
Voltage supply AM [V/~/Hz]230/1/50
Max. Current consumption [A]18.0
Nominal current consumption (A7/W35) [A]8.85
Nominal power consumption (A7/W35) [kW]2.07
Nominal power consumption (A2/W35) [kW]2.10
Max. Power consumption [kW]4.1
Nominal water volume flow [m³/h]1.8
External pressure loss [kPa]70.0
Air volume flow outdoor unit, max. [m³/h]3. 350
Sound power level outdoor unit LwA [dB(A)]58.3
Sound pressure level outdoor unit 3) 5m [dB(A)]33.3
Dimensions (H/W/D) [mm]1165/845/370
Weight outdoor unit [kg]80.0
1) COP = Coefficient Of Performance according to EN 14511, TÜV tested
2) EER=Energy Efficiency Ratio according to EN 14511
3) with full spherical dispersion, A7/W55 measurement according to DIN EN 12102 and DIN EN ISO 9614-2
The appliances comply with the relevant EU regulations and are CE-marked in accordance with the applicable directives. The appliances have been tested by TÜV Süd.
Additional information
Product group:
4101
Type:
VA
Related results
Complete catalogs
The offer is aimed exclusively at business customers, companies, public institutions, tradesmen and freelancers. All prices in catalogues are exclusive of VAT, shipping costs and surcharges if applicable.
The manufacturer is exclusively responsible for the content, price and article details of the products and offers presented in the catalogues. Subject to technical and optical changes by the manufacturer and errors excepted.
The manufacturer is exclusively responsible for the content, price and article details of the products and offers presented in the catalogues. Subject to technical and optical changes by the manufacturer and errors excepted.
Matching catalog
Commercial customer offer**
Product suggestions
-13%
Condensate drip tray KWK 450/600 (ZW)
1111783
€169.33
-19%
ATY 527 Deco IT Arctic
1624582
€706.89
€870.00 MSRP
Fan blade 200/31 DZH 20-2
1111663
€25.00
-14%
Heating circuit pump HGU/HGM Wilo Stratos PARA 25/1-7 T1
1120909
€372.61
Condensate nozzle with plug MKT 240/250
1106882
€10.17
Whirler WKL/VRS 50-60
1102954
€22.14
-10%
Device cover SKW 520 IT
1113560
€62.51
-14%
Outer casing INOX ELT 10-HT
1101511
€286.85
Condensate nozzle RVD 684/MVD 701-1001
1114421
€9.20
-13%
Oil pump VM 1
1108498
€189.03
-13%
Power board 954460 RVS
1106710
€128.53
-4%
Insert (Vent. plug)
1108317
€33.95
Oil nozzle 2.25/60 degree S
1102823
€23.82
Relay Board Merlin CMF/CMT-New version
1120030-N
€396.93
-13%
Oil pump AD1L2 Replacement for V1-LR2 1/4?
1108640
€159.20
No Review yet
Description: No Review yet
Written by: No Review
Rating: 5 out of 5
5 stars, based on 1
reviews
Remko RK WP WKF 130 Duo AM, versatile in use 264083
4026415177836
264083
REMKO GmbH & Co. KG
heating technology
air conditioning technology
room air conditioners
Outdoor module WKF 130
Inverter-controlled outdoor module for heat absorption from the ambient air. Outdoor installation. Housing and frame are made of sturdy galvanised sheet steel with an additional weather-resistant polyester stove enamel finish and internal sound insulation. Large removable panelling elements. Colour RAL 9006/7021
Available as accessories:
Refrigerant lines
Floor or wall bracket for outdoor module
Condensate drip tray without/with oil separator
Electric condensate drain heater
Environmental protection regulations and laws must be observed.
Technical performance data:
Type designationREMKO WKF 130 AM
Heating output [kW]2.0-12.5
Space heating energy efficiency Average 35/55 [%]XX/XX
Efficiency class (heating)A++/A++
Heating application limits [°C]-20 to +37
Flow temperature heating water max. [°C]60
Nominal heating output for A12/W35 1) [kW]12.0
Nominal heating output for A7/W35 1) [kW]10.3
Nominal heating output for A2/W35 1) [kW]8.7
Nominal heating output for A-7/W35 1) [kW]6.9
Nominal heating output for A-15/W35 1) [kW]5.1
COP for A12/W35/HZ 1) 5, 87/79
COP for A7/W35/HZ 1) 5.07/79
COP for A2/W35/HZ 1) 4.14/79
COP for A-7/W35/HZ 1) 3.47/79
COP for A-15/W35°/HZ 1) 2.69/79
Cooling application limits [°C]+15 to +43
Cooling capacity [kW]2.1-10.5
Flow temperature of cooling water min. [°C]7
Cooling capacity A35/W7 KW/EER 2)8.5/2.7
Cooling capacity A35/W18 KW/EER 2)9.8/3.9
RefrigerantR32
Refrigerant quantity [kg]1.8
Additional filling quantity from 5m single length [g/m]30
Refrigerant connections3/8‘ / 5/8’
Refrigerant line, length max. [m]20.0
Height difference refrigerant line, max. [m]10.0
Voltage supply AM [V/~/Hz]230/1/50
Max. Current consumption [A]18.0
Nominal current consumption (A7/W35) [A]8.85
Nominal power consumption (A7/W35) [kW]2.07
Nominal power consumption (A2/W35) [kW]2.10
Max. Power consumption [kW]4.1
Nominal water volume flow [m³/h]1.8
External pressure loss [kPa]70.0
Air volume flow outdoor unit, max. [m³/h]3. 350
Sound power level outdoor unit LwA [dB(A)]58.3
Sound pressure level outdoor unit 3) 5m [dB(A)]33.3
Dimensions (H/W/D) [mm]1165/845/370
Weight outdoor unit [kg]80.0
1) COP = Coefficient Of Performance according to EN 14511, TÜV tested
2) EER=Energy Efficiency Ratio according to EN 14511
3) with full spherical dispersion, A7/W55 measurement according to DIN EN 12102 and DIN EN ISO 9614-2
The appliances comply with the relevant EU regulations and are CE-marked in accordance with the applicable directives. The appliances have been tested by TÜV Süd. T-888825 264083 4026415177836 en ["de","en","it","nl","nl","fr","es","pl","pt","cs","da","sv"] https://www.toolteam.com/en-GB/remko-rk-wp-wkf-130-duo-am-versatile-in-use-264083-t-888825-4026415177836?dc=GB&cu=EUR 2026-08-02 2760.66 United Kingdom GB DE 14
Inverter-controlled outdoor module for heat absorption from the ambient air. Outdoor installation. Housing and frame are made of sturdy galvanised sheet steel with an additional weather-resistant polyester stove enamel finish and internal sound insulation. Large removable panelling elements. Colour RAL 9006/7021
Available as accessories:
Refrigerant lines
Floor or wall bracket for outdoor module
Condensate drip tray without/with oil separator
Electric condensate drain heater
Environmental protection regulations and laws must be observed.
Technical performance data:
Type designationREMKO WKF 130 AM
Heating output [kW]2.0-12.5
Space heating energy efficiency Average 35/55 [%]XX/XX
Efficiency class (heating)A++/A++
Heating application limits [°C]-20 to +37
Flow temperature heating water max. [°C]60
Nominal heating output for A12/W35 1) [kW]12.0
Nominal heating output for A7/W35 1) [kW]10.3
Nominal heating output for A2/W35 1) [kW]8.7
Nominal heating output for A-7/W35 1) [kW]6.9
Nominal heating output for A-15/W35 1) [kW]5.1
COP for A12/W35/HZ 1) 5, 87/79
COP for A7/W35/HZ 1) 5.07/79
COP for A2/W35/HZ 1) 4.14/79
COP for A-7/W35/HZ 1) 3.47/79
COP for A-15/W35°/HZ 1) 2.69/79
Cooling application limits [°C]+15 to +43
Cooling capacity [kW]2.1-10.5
Flow temperature of cooling water min. [°C]7
Cooling capacity A35/W7 KW/EER 2)8.5/2.7
Cooling capacity A35/W18 KW/EER 2)9.8/3.9
RefrigerantR32
Refrigerant quantity [kg]1.8
Additional filling quantity from 5m single length [g/m]30
Refrigerant connections3/8‘ / 5/8’
Refrigerant line, length max. [m]20.0
Height difference refrigerant line, max. [m]10.0
Voltage supply AM [V/~/Hz]230/1/50
Max. Current consumption [A]18.0
Nominal current consumption (A7/W35) [A]8.85
Nominal power consumption (A7/W35) [kW]2.07
Nominal power consumption (A2/W35) [kW]2.10
Max. Power consumption [kW]4.1
Nominal water volume flow [m³/h]1.8
External pressure loss [kPa]70.0
Air volume flow outdoor unit, max. [m³/h]3. 350
Sound power level outdoor unit LwA [dB(A)]58.3
Sound pressure level outdoor unit 3) 5m [dB(A)]33.3
Dimensions (H/W/D) [mm]1165/845/370
Weight outdoor unit [kg]80.0
1) COP = Coefficient Of Performance according to EN 14511, TÜV tested
2) EER=Energy Efficiency Ratio according to EN 14511
3) with full spherical dispersion, A7/W55 measurement according to DIN EN 12102 and DIN EN ISO 9614-2
The appliances comply with the relevant EU regulations and are CE-marked in accordance with the applicable directives. The appliances have been tested by TÜV Süd. T-888825 264083 4026415177836 en ["de","en","it","nl","nl","fr","es","pl","pt","cs","da","sv"] https://www.toolteam.com/en-GB/remko-rk-wp-wkf-130-duo-am-versatile-in-use-264083-t-888825-4026415177836?dc=GB&cu=EUR 2026-08-02 2760.66 United Kingdom GB DE 14