zoom_in
zoom_out
fullscreen
-19%
Remko RK WP fresh water station 260184
Sku: T-888784
€11,079.16 (excl. legal VAT, excl. Shipping)
(€5,539.58 / Piece)
€13,644.96 MSRP
In stock,ready for shipping within 24h
Package
Product variants
| Sku: | Name: | SKU manufacturer: | ||
|---|---|---|---|---|
|
T-888783 | RK WP Fresh water station | 260183 |
doneEFS 50.1 Duo
EFS 50.1 Duo 260184, versatile application
Content:
1 Package = 2 Piece (€5,539.58 / Piece)
Shipping:
€526.81 Versandservice to United Kingdom
For orders from €1,000.00 order total plus €34.45 Customs MRN registration
Lieferung:
Provider:
Sales and delivery by ToolTeam Köln
Payment methods:
Returns:
Security:
Product data
Manufacturer:
REMKO GmbH & Co. KG
Condition:
NEW
Sku:
T-888784
SKU manufacturer:
260184
GTIN Code (EAN):
4026415169985
Weight:
78,40 Kg
All information relating to products from REMKO GmbH & Co. KG. Technical and optical modifications of the manufacturer and errors reserved.
This page has been machine-translated, the original german version can be found here, please also note the Translation Disclaimer.
Product description
Fresh water station EFS 50.1 Duo
for hygienic hot water preparation in conjunction with a Remko MPS cylinder. Cascading of two EFS 50.1 fresh water stations including cascade pipe assembly. For wall mounting. Complete with control unit, speed-controlled Grundfoss pump, sensors, volume flow meter, gravity brakes, ball valves for shutting off the primary and secondary circuits and a plate heat exchanger. Minimum water volume for DHW heating 2000 litres.
Pre-set control, with the option of controlling the Remko circulation pump with a 0-10 volt control.
Technical performance data:
Primary circuit:
Flow buffer tank2‘ AG
Return buffer tank2’ AG
Max. Pressure, primary [bar]3
Secondary circuit
Hot water outlet1 1/4‘ flat sealing
Cold water inlet1 1/4’ flat sealing
Max. Max. pressure, secondary [bar]10
Perm. Operating temperature [°C]2-95
Gravity brake [mmWs]2x400
Heat exchanger60 plates
Volume flow sensor [l/min]1-80
Temperature sensorsPt 1000
Energy efficiency index(EEI)≤ 0, 23
Voltage supply [V/~/Hz]230/1/50
Current at 1~230V [A]0.06-0.58
Tap volume at 45 °C tap temp. and 50 °C storage tank temp. l/min. 100
Draw-off quantity at 45 °C draw-off temp. and 60 °C storage temp. l/min. 154
Dispensing quantity at 45 °C dispensing temp. and 70 °C storage temp. l/min. 176
for hygienic hot water preparation in conjunction with a Remko MPS cylinder. Cascading of two EFS 50.1 fresh water stations including cascade pipe assembly. For wall mounting. Complete with control unit, speed-controlled Grundfoss pump, sensors, volume flow meter, gravity brakes, ball valves for shutting off the primary and secondary circuits and a plate heat exchanger. Minimum water volume for DHW heating 2000 litres.
Pre-set control, with the option of controlling the Remko circulation pump with a 0-10 volt control.
Technical performance data:
Primary circuit:
Flow buffer tank2‘ AG
Return buffer tank2’ AG
Max. Pressure, primary [bar]3
Secondary circuit
Hot water outlet1 1/4‘ flat sealing
Cold water inlet1 1/4’ flat sealing
Max. Max. pressure, secondary [bar]10
Perm. Operating temperature [°C]2-95
Gravity brake [mmWs]2x400
Heat exchanger60 plates
Volume flow sensor [l/min]1-80
Temperature sensorsPt 1000
Energy efficiency index(EEI)≤ 0, 23
Voltage supply [V/~/Hz]230/1/50
Current at 1~230V [A]0.06-0.58
Tap volume at 45 °C tap temp. and 50 °C storage tank temp. l/min. 100
Draw-off quantity at 45 °C draw-off temp. and 60 °C storage temp. l/min. 154
Dispensing quantity at 45 °C dispensing temp. and 70 °C storage temp. l/min. 176
Hinweise zur Batterieentsorgung:
Da in unseren Sendungen Batterien und Akkus enthalten sein können, sind wir nach dem Batteriegesetz (BattG) verpflichtet, Sie auf Folgendes hinzuweisen:
- Batterien und Akkus dürfen nicht im Hausmüll entsorgt werden, sondern Sie sind zur Rückgabe gebrauchter Batterien und Akkus gesetzlich verpflichtet.
- Altbatterien können Schadstoffe enthalten, die bei nicht sachgemäßer Lagerung oder Entsorgung die Umwelt oder Ihre Gesundheit schädigen können. Batterien enthalten aber auch wichtige Rohstoffe wie z.B. Eisen, Zink, Mangan oder Nickel und können verwertet werden.
- Sie können die Batterien nach Gebrauch entweder an uns zurücksenden oder in unmittelbarer Nähe (z.B. im Handel oder in kommunalen Sammelstellen oder in unserem Lager) unentgeltlich zurückgeben.
- Die Abgabe in Verkaufsstellen ist dabei für Endnutzer auf die übliche Mengen sowie solche Altbatterien beschränkt, die der Vertreiber als Neubatterien in seinem Sortiment führt oder geführt hat.
- Das Zeichen mit der durchgekreuzten Mülltonne bedeutet, dass Sie Batterien und Akkus nicht im Hausmüll entsorgen dürfen
Unter diesen Zeichen finden Sie zusätzlich nachstehende Symbole mit folgender Bedeutung:
- Pb = Batterie enthält mehr als 0,004 Masseprozent Blei
- Cd = Batterie enthält mehr als 0,002 Masseprozent Cadmium
- Hg = Batterie enthält mehr als 0,0005 Masseprozent Quecksilber
Additional information
Product group:
4151
Width (mm):
602.0MMT
Height (mm):
795.0MMT
Length (mm):
298.0MMT
Type:
STD
Related results
Complete catalogs
The offer is aimed exclusively at business customers, companies, public institutions, tradesmen and freelancers. All prices in catalogues are exclusive of VAT, shipping costs and surcharges if applicable.
The manufacturer is exclusively responsible for the content, price and article details of the products and offers presented in the catalogues. Subject to technical and optical changes by the manufacturer and errors excepted.
The manufacturer is exclusively responsible for the content, price and article details of the products and offers presented in the catalogues. Subject to technical and optical changes by the manufacturer and errors excepted.
Matching catalog
Commercial customer offer**
Product suggestions
Mounting plate shut-off valve RVT 263 DC AT
1112422
€15.25
-19%
RK WP fresh water station
260181
€2,691.25
€3,312.01 MSRP
Oil nozzle 2.25/60 degree S
1102823
€23.82
Whirler WKL/VRS 50-60
1102954
€22.14
-10%
Device cover SKW 520 IT
1113560
€62.51
-13%
Oil pump AD1L2 Replacement for V1-LR2 1/4?
1108640
€159.20
-4%
Housing front BL 353 DC IT/SKW 350 DC IT
1113452
€63.32
Condensate nozzle RVD 684/MVD 701-1001
1114421
€9.20
-4%
Support ring, 1-piece RK 25-50
1104168
€43.87
-4%
Insert (Vent. plug)
1108317
€33.95
Fan blade 200/31 DZH 20-2
1111663
€25.00
Condensate nozzle with plug MKT 240/250
1106882
€10.17
-19%
RK sound insulation hood SWK 5.1,
260939
€2,015.21
€2,480.00 MSRP
-14%
Heating circuit pump HGU/HGM Wilo Stratos PARA 25/1-7 T1
1120909
€372.61
-14%
Outer casing INOX ELT 10-HT
1101511
€286.85
No Review yet
Description: No Review yet
Written by: No Review
Rating: 5 out of 5
5 stars, based on 1
reviews
Remko RK WP fresh water station 260184
4026415169985
260184
REMKO GmbH & Co. KG
heating technology
air conditioning technology
room air conditioners
Fresh water station EFS 50.1 Duo
for hygienic hot water preparation in conjunction with a Remko MPS cylinder. Cascading of two EFS 50.1 fresh water stations including cascade pipe assembly. For wall mounting. Complete with control unit, speed-controlled Grundfoss pump, sensors, volume flow meter, gravity brakes, ball valves for shutting off the primary and secondary circuits and a plate heat exchanger. Minimum water volume for DHW heating 2000 litres.
Pre-set control, with the option of controlling the Remko circulation pump with a 0-10 volt control.
Technical performance data:
Primary circuit:
Flow buffer tank2‘ AG
Return buffer tank2’ AG
Max. Pressure, primary [bar]3
Secondary circuit
Hot water outlet1 1/4‘ flat sealing
Cold water inlet1 1/4’ flat sealing
Max. Max. pressure, secondary [bar]10
Perm. Operating temperature [°C]2-95
Gravity brake [mmWs]2x400
Heat exchanger60 plates
Volume flow sensor [l/min]1-80
Temperature sensorsPt 1000
Energy efficiency index(EEI)≤ 0, 23
Voltage supply [V/~/Hz]230/1/50
Current at 1~230V [A]0.06-0.58
Tap volume at 45 °C tap temp. and 50 °C storage tank temp. l/min. 100
Draw-off quantity at 45 °C draw-off temp. and 60 °C storage temp. l/min. 154
Dispensing quantity at 45 °C dispensing temp. and 70 °C storage temp. l/min. 176 T-888784 260184 4026415169985 en ["de","en","it","nl","nl","fr","es","pl","pt","cs","da","sv"] https://www.toolteam.com/en-GB/remko-rk-wp-fresh-water-station-260184-t-888784-4026415169985?dc=GB&cu=EUR 2026-07-11 11079.16 United Kingdom GB DE 14
for hygienic hot water preparation in conjunction with a Remko MPS cylinder. Cascading of two EFS 50.1 fresh water stations including cascade pipe assembly. For wall mounting. Complete with control unit, speed-controlled Grundfoss pump, sensors, volume flow meter, gravity brakes, ball valves for shutting off the primary and secondary circuits and a plate heat exchanger. Minimum water volume for DHW heating 2000 litres.
Pre-set control, with the option of controlling the Remko circulation pump with a 0-10 volt control.
Technical performance data:
Primary circuit:
Flow buffer tank2‘ AG
Return buffer tank2’ AG
Max. Pressure, primary [bar]3
Secondary circuit
Hot water outlet1 1/4‘ flat sealing
Cold water inlet1 1/4’ flat sealing
Max. Max. pressure, secondary [bar]10
Perm. Operating temperature [°C]2-95
Gravity brake [mmWs]2x400
Heat exchanger60 plates
Volume flow sensor [l/min]1-80
Temperature sensorsPt 1000
Energy efficiency index(EEI)≤ 0, 23
Voltage supply [V/~/Hz]230/1/50
Current at 1~230V [A]0.06-0.58
Tap volume at 45 °C tap temp. and 50 °C storage tank temp. l/min. 100
Draw-off quantity at 45 °C draw-off temp. and 60 °C storage temp. l/min. 154
Dispensing quantity at 45 °C dispensing temp. and 70 °C storage temp. l/min. 176 T-888784 260184 4026415169985 en ["de","en","it","nl","nl","fr","es","pl","pt","cs","da","sv"] https://www.toolteam.com/en-GB/remko-rk-wp-fresh-water-station-260184-t-888784-4026415169985?dc=GB&cu=EUR 2026-07-11 11079.16 United Kingdom GB DE 14