zoom_in
zoom_out
fullscreen
-19%
Remko RK WP Fresh water station 260183
Sku: T-888783
€7,139.54 (excl. legal VAT, excl. Shipping)
(€3,569.77 / Piece)
€8,793.03 MSRP
In stock,ready for shipping
Package
Product variants
| Sku: | Name: | SKU manufacturer: | ||
|---|---|---|---|---|
|
T-888784 | RK WP fresh water station | 260184 |
doneEFS 35.1 Duo
EFS 35.1 Duo 260183, versatile application
Content:
1 Package = 2 Piece (€3,569.77 / Piece)
Shipping:
€378.07 Versandservice to United Kingdom
For orders from €1,000.00 order total plus €34.45 Customs MRN registration
Lieferung:
Provider:
Sales and delivery by ToolTeam Köln
Payment methods:
Returns:
Security:
Product data
Manufacturer:
REMKO GmbH & Co. KG
Condition:
NEW
Sku:
T-888783
SKU manufacturer:
260183
GTIN Code (EAN):
4026415166250
Weight:
61,00 Kg
All information relating to products from REMKO GmbH & Co. KG. Technical and optical modifications of the manufacturer and errors reserved.
This page has been machine-translated, the original german version can be found here, please also note the Translation Disclaimer.
Product description
Fresh water station EFS 35.1 Duo
for hygienic hot water preparation in conjunction with a Remko MPS cylinder. Cascading of two EFS 35.1 fresh water stations including cascade pipe assembly. For wall mounting. Complete with control unit, speed-controlled Grundfoss pump, sensors, volume flow meter, gravity brakes, ball valves for shutting off the primary and secondary circuits and a plate heat exchanger. Minimum water volume for DHW heating 1000 litres.
Pre-set control, with the option of controlling the Remko circulation pump with a 0-10 volt control.
Technical performance data:
Primary circuit:
Flow buffer tank1 1/2‘ AG
Return buffer tank1 1/2’ AG
Max. Pressure, primary [bar]3
Secondary circuit
Hot water outlet1‘ flat-sealing
Cold water inlet1’ flat-sealing
Max. Pressure, secondary [bar]10
Perm. Operating temperature [°C]2-95
Gravity brake [mmWs]2x200
Heat exchanger40 plates
Volume flow sensor [l/min]1-80
Temperature sensorsPt 1000
Energy efficiency index(EEI)≤ 0, 23
Voltage supply [V/~/Hz]230/1/50
Current at 1~230V [A]0.06-0.58
Tap volume at 45 °C tap temp. and 50 °C storage tank temp. l/min. 64
Draw-off quantity at 45 °C draw-off temp. and 60 °C storage temp. l/min. 100
Dispensing quantity at 45 °C dispensing temp. and 70 °C storage temp. l/min. 128
for hygienic hot water preparation in conjunction with a Remko MPS cylinder. Cascading of two EFS 35.1 fresh water stations including cascade pipe assembly. For wall mounting. Complete with control unit, speed-controlled Grundfoss pump, sensors, volume flow meter, gravity brakes, ball valves for shutting off the primary and secondary circuits and a plate heat exchanger. Minimum water volume for DHW heating 1000 litres.
Pre-set control, with the option of controlling the Remko circulation pump with a 0-10 volt control.
Technical performance data:
Primary circuit:
Flow buffer tank1 1/2‘ AG
Return buffer tank1 1/2’ AG
Max. Pressure, primary [bar]3
Secondary circuit
Hot water outlet1‘ flat-sealing
Cold water inlet1’ flat-sealing
Max. Pressure, secondary [bar]10
Perm. Operating temperature [°C]2-95
Gravity brake [mmWs]2x200
Heat exchanger40 plates
Volume flow sensor [l/min]1-80
Temperature sensorsPt 1000
Energy efficiency index(EEI)≤ 0, 23
Voltage supply [V/~/Hz]230/1/50
Current at 1~230V [A]0.06-0.58
Tap volume at 45 °C tap temp. and 50 °C storage tank temp. l/min. 64
Draw-off quantity at 45 °C draw-off temp. and 60 °C storage temp. l/min. 100
Dispensing quantity at 45 °C dispensing temp. and 70 °C storage temp. l/min. 128
Hinweise zur Batterieentsorgung:
Da in unseren Sendungen Batterien und Akkus enthalten sein können, sind wir nach dem Batteriegesetz (BattG) verpflichtet, Sie auf Folgendes hinzuweisen:
- Batterien und Akkus dürfen nicht im Hausmüll entsorgt werden, sondern Sie sind zur Rückgabe gebrauchter Batterien und Akkus gesetzlich verpflichtet.
- Altbatterien können Schadstoffe enthalten, die bei nicht sachgemäßer Lagerung oder Entsorgung die Umwelt oder Ihre Gesundheit schädigen können. Batterien enthalten aber auch wichtige Rohstoffe wie z.B. Eisen, Zink, Mangan oder Nickel und können verwertet werden.
- Sie können die Batterien nach Gebrauch entweder an uns zurücksenden oder in unmittelbarer Nähe (z.B. im Handel oder in kommunalen Sammelstellen oder in unserem Lager) unentgeltlich zurückgeben.
- Die Abgabe in Verkaufsstellen ist dabei für Endnutzer auf die übliche Mengen sowie solche Altbatterien beschränkt, die der Vertreiber als Neubatterien in seinem Sortiment führt oder geführt hat.
- Das Zeichen mit der durchgekreuzten Mülltonne bedeutet, dass Sie Batterien und Akkus nicht im Hausmüll entsorgen dürfen
Unter diesen Zeichen finden Sie zusätzlich nachstehende Symbole mit folgender Bedeutung:
- Pb = Batterie enthält mehr als 0,004 Masseprozent Blei
- Cd = Batterie enthält mehr als 0,002 Masseprozent Cadmium
- Hg = Batterie enthält mehr als 0,0005 Masseprozent Quecksilber
Additional information
Product group:
4151
Width (mm):
602.0MMT
Height (mm):
795.0MMT
Length (mm):
298.0MMT
Type:
STD
Related results
Complete catalogs
The offer is aimed exclusively at business customers, companies, public institutions, tradesmen and freelancers. All prices in catalogues are exclusive of VAT, shipping costs and surcharges if applicable.
The manufacturer is exclusively responsible for the content, price and article details of the products and offers presented in the catalogues. Subject to technical and optical changes by the manufacturer and errors excepted.
The manufacturer is exclusively responsible for the content, price and article details of the products and offers presented in the catalogues. Subject to technical and optical changes by the manufacturer and errors excepted.
Matching catalog
Commercial customer offer**
Product suggestions
-13%
Condensate drip tray KWK 450/600 (ZW)
1111783
€169.33
-4%
Support ring, 1-piece RK 25-50
1104168
€43.87
-19%
RK sound insulation hood SWK 4.1,
260938
€1,917.69
€2,360.00 MSRP
-4%
Insert (Vent. plug)
1108317
€33.95
-14%
Relay board WP-Manager (WMZ version) CMT 120/160
1120194
€297.69
-14%
Control board RVT 681 DC AT
1109849
€453.07
-4%
Pressure gauge 0-6 bar 1/4?
1108426
€59.16
-14%
Heating circuit pump HGU/HGM Wilo Stratos PARA 25/1-7 T1
1120909
€372.61
-13%
Oil pump AD1L2 Replacement for V1-LR2 1/4?
1108640
€159.20
-19%
ATY 527 Deco
1623434
€658.19
€810.00 MSRP
Accessory pack 1
1106445
€21.67
-13%
Pressure regulator 1.5 bar/10 kg
1101663
€186.60
-19%
ZA axial fan 501-4
1108376
€808.06
€994.41 MSRP
Silencer RK 70
1104117
€7.10
Condensate nozzle with plug MKT 240/250
1106882
€10.17
No Review yet
Description: No Review yet
Written by: No Review
Rating: 5 out of 5
5 stars, based on 1
reviews
Remko RK WP Fresh water station 260183
4026415166250
260183
REMKO GmbH & Co. KG
heating technology
air conditioning technology
room air conditioners
Fresh water station EFS 35.1 Duo
for hygienic hot water preparation in conjunction with a Remko MPS cylinder. Cascading of two EFS 35.1 fresh water stations including cascade pipe assembly. For wall mounting. Complete with control unit, speed-controlled Grundfoss pump, sensors, volume flow meter, gravity brakes, ball valves for shutting off the primary and secondary circuits and a plate heat exchanger. Minimum water volume for DHW heating 1000 litres.
Pre-set control, with the option of controlling the Remko circulation pump with a 0-10 volt control.
Technical performance data:
Primary circuit:
Flow buffer tank1 1/2‘ AG
Return buffer tank1 1/2’ AG
Max. Pressure, primary [bar]3
Secondary circuit
Hot water outlet1‘ flat-sealing
Cold water inlet1’ flat-sealing
Max. Pressure, secondary [bar]10
Perm. Operating temperature [°C]2-95
Gravity brake [mmWs]2x200
Heat exchanger40 plates
Volume flow sensor [l/min]1-80
Temperature sensorsPt 1000
Energy efficiency index(EEI)≤ 0, 23
Voltage supply [V/~/Hz]230/1/50
Current at 1~230V [A]0.06-0.58
Tap volume at 45 °C tap temp. and 50 °C storage tank temp. l/min. 64
Draw-off quantity at 45 °C draw-off temp. and 60 °C storage temp. l/min. 100
Dispensing quantity at 45 °C dispensing temp. and 70 °C storage temp. l/min. 128 T-888783 260183 4026415166250 en ["de","en","it","nl","nl","fr","es","pl","pt","cs","da","sv"] https://www.toolteam.com/en-GB/remko-rk-wp-fresh-water-station-260183-t-888783-4026415166250?dc=GB&cu=EUR 2026-07-13 7139.54 United Kingdom GB DE 14
for hygienic hot water preparation in conjunction with a Remko MPS cylinder. Cascading of two EFS 35.1 fresh water stations including cascade pipe assembly. For wall mounting. Complete with control unit, speed-controlled Grundfoss pump, sensors, volume flow meter, gravity brakes, ball valves for shutting off the primary and secondary circuits and a plate heat exchanger. Minimum water volume for DHW heating 1000 litres.
Pre-set control, with the option of controlling the Remko circulation pump with a 0-10 volt control.
Technical performance data:
Primary circuit:
Flow buffer tank1 1/2‘ AG
Return buffer tank1 1/2’ AG
Max. Pressure, primary [bar]3
Secondary circuit
Hot water outlet1‘ flat-sealing
Cold water inlet1’ flat-sealing
Max. Pressure, secondary [bar]10
Perm. Operating temperature [°C]2-95
Gravity brake [mmWs]2x200
Heat exchanger40 plates
Volume flow sensor [l/min]1-80
Temperature sensorsPt 1000
Energy efficiency index(EEI)≤ 0, 23
Voltage supply [V/~/Hz]230/1/50
Current at 1~230V [A]0.06-0.58
Tap volume at 45 °C tap temp. and 50 °C storage tank temp. l/min. 64
Draw-off quantity at 45 °C draw-off temp. and 60 °C storage temp. l/min. 100
Dispensing quantity at 45 °C dispensing temp. and 70 °C storage temp. l/min. 128 T-888783 260183 4026415166250 en ["de","en","it","nl","nl","fr","es","pl","pt","cs","da","sv"] https://www.toolteam.com/en-GB/remko-rk-wp-fresh-water-station-260183-t-888783-4026415166250?dc=GB&cu=EUR 2026-07-13 7139.54 United Kingdom GB DE 14