zoom_in
zoom_out
fullscreen
Remko RK Klima cold water KWP 660 Eco 1707660
Sku: T-888745
Discontinued item
Product variants
| Sku: | Name: | SKU manufacturer: | ||
|---|---|---|---|---|
|
T-888741 | RK Klima cold water KWP 460 Eco | 1707460 | |
|
T-888742 | RK Klima cold water KWP 520 Eco | 1707520 | |
|
T-888744 | RK Klima cold water KWP 600 Eco | 1707600 | |
|
T-888746 | RK Klima cold water KWP 790 Eco | 1707790 | |
|
T-888747 | RK Klima Kaltwasser KWP 900 Eco, versatile in use | 1707900 | |
|
T-888748 | RK Klima cold water KWP 1030 Eco | 1708030 | |
|
T-888749 | RK A/C chilled water KWP 1120 Eco | 1708120 |
doneProduct group: 4001
doneType: STD
doneType: STD
Product data
Manufacturer:
REMKO GmbH & Co. KG
Condition:
NEW
Sku:
T-888745
SKU manufacturer:
1707660
GTIN Code (EAN):
4026415172329
Weight:
552,00 Kg
All information relating to products from REMKO GmbH & Co. KG. Technical and optical modifications of the manufacturer and errors reserved.
This page has been machine-translated, the original german version can be found here, please also note the Translation Disclaimer.
Product description
Air-cooled chiller with heat pump function KWP 660 Eco for outdoor installation in high-efficiency design and modular construction
Unit frame
Free-standing base frame made of galvanised sheet steel and heat-treated polyester paint for outdoor installation, standard colour similar to RAL 9018. Removable housing panels allow full access to unit components for increased ease of maintenance.
Heat exchanger, internal
Brazed plate heat exchanger in high-efficiency design made of stainless steel (AISI 316), fully thermally insulated. Maximum permissible operating pressure 8 bar on the medium side. Flow monitor and refrigeration circuit monitoring to protect the plate heat exchanger.
Heat exchanger, external
High-performance condenser made of refrigeration copper tube with positive-locking aluminium fins and optional condenser protection grille.
Refrigeration circuit
Hermetically sealed refrigeration circuit made of refrigeration copper tube. Vibration-damped scroll compressor(s) from the Danfoss DSH compressor series with built-in motor protection switch to protect against overload and overtemperature. Crankcase heater for compressor(s) to heat the oil sump when the unit is at a standstill and at low ambient temperatures as well as to increase the service life as standard. Additional compressor insulation to reduce noise emissions available as an option. Schrader valve accesses on the high and low pressure side enable refrigeration measurements and work without having to open the refrigeration circuit. Pressure sensors on the high and low pressure side for measuring and processing operationally relevant device parameters. Filter dryer with molecular sieve for filtering out the smallest impurities in the refrigeration circuit and drying residual moisture in the refrigerant. Sight glass with humidity indicator for monitoring the acid content of the refrigerant and displaying the aggregate state of the refrigerant upstream of the expansion valve. Preset, electronic expansion valve to increase the control quality and energy efficiency of the chiller.
Use of the innovative and climate-friendly refrigerant R452B of class A2L with a greenhouse gas potential three times lower than comparable refrigerants (comparison R410A).
4-way changeover valve for process reversal from cooling mode to heating mode. Integrated defrost logic for defrosting the finned heat exchanger during heating operation at low outside temperatures.
Fan(s)
Aerodynamically optimised axial fan in EC design with glass fibre-reinforced plastic fins and unique aluminium support structure to minimise noise emissions and maximise efficiency. Fan design in protection class IP 54, insulation class F. Optionally available in AxiTop design to minimise noise emissions.
Working range
Adjustable return temperature range from +5°C to +18°C in cooling mode, +25°C to +50°C in heating mode. Operating range in cooling mode from -15°C to +48°C outside temperature, in heating mode -10°C to +30°C as standard.
Medium circuit
Medium circuit insulated vapour diffusion-tight. Hydraulic circuit can be individually configured, pumps in various pressure levels and integrated medium storage tank as buffer storage to increase the system volume optionally available, see separate tender texts. Medium connections in imperial design with external thread.
Electrics / control
Main switch accessible from the outside on the operating side of the device. Carel pLDPRO controller protected from unauthorised access and the weather by a cover. Hinged enclosure door enables access and opening of the enclosure without having to dismantle housing parts. 3 user levels enable user access to user-relevant device parameters and changes by installers at specialist level. Password-protected manufacturer level for highly sensitive parameter area at programming level. Fully wired and tested main and control circuit including terminal strip for mains supply, phase sequence relay for monitoring the rotating field, load contactors and control relays, transformer and circuit breaker for protection against overload and short-circuit currents. External start/stop contact for switching the device on and off and collective fault signalling contact for external use. Modbus interface RS485 can be retrofitted as an accessory. Fault memory including recording of date and time in the event of a fault for simplified diagnosis. Control cabinet heater integrated as standard to prevent condensation in the control cabinet due to temperature fluctuations at low ambient temperatures. All components are electrically wired and installed in the control cabinet of the appliance.
Other
Rainwater collector pipe and central drainage via screw connections with external thread.
Eco-design directive
Compliance with all requirements of the Ecodesign Directive (EU) 2016/2281 (LOT 21) for chillers for comfort air conditioning in accordance with technical data (see SEER and annual space cooling efficiency ratio).
Available as accessories:
Medium circuit with pump or storage tank and pump in various pressure levels
Glycol
Cable remote control
Condenser protection grille
Vibration damper
Manometer medium circuit
Soft start
Control cabinet ventilation
Modbus interface RS485
Technical unit handover
The units comply with the relevant EU regulations and are CE-marked in accordance with the applicable directives.
Technical performance data:
Type designationREMKO KWP 660 Eco
Nominal cooling capacity, total 1) [kW]66.3
Nominal heating capacity, total 2) [kW]74.4
SEER [--]4.9
Room cooling annual utilisation factor [%]187
Setting range, return temperature, cooling [°C]+5 to +18
Setting range, return temperature, Heating [°C]+25 to +50
Cooling operating range [°C]-15 to +48
Heating operating range [°C]-10 to +30
Compressor, number / type2 / scroll
Capacity gradation [%]0 / 50 / 100
Refrigeration circuits, Number1
RefrigerantR452B
Refrigerant, basic quantity [kg]18.0
CO2 equivalent [t]12.2
Fan, number1
Air volume flow, max. [m³/h]22,000
Sound pressure level 3) [dB(A)]54.7
Sound power level [dB(A)]86.7
Voltage supply [V/~/Hz]400/3~N/50
Protection classIP X4
Electr. rated power consumption cooling 1) [kW]20.1
Electr. Nominal current consumption cooling 1) [A]36.3
Nominal volume flow, medium cooling [m³/h]11.4
Medium connections2 ‘
Outdoor unit dimensions (H/W/D) [mm]2345/1100/1350
Weight [kg]552
Serial colour similar to RAL 9018
1) Air inlet 35°C, medium temperatures 7/12 °C, 0% glycol concentration
2) Air inlet 7°C, medium temperatures 45/40 °C, 0% glycol concentration
3) Distance 10 m free field
Unit frame
Free-standing base frame made of galvanised sheet steel and heat-treated polyester paint for outdoor installation, standard colour similar to RAL 9018. Removable housing panels allow full access to unit components for increased ease of maintenance.
Heat exchanger, internal
Brazed plate heat exchanger in high-efficiency design made of stainless steel (AISI 316), fully thermally insulated. Maximum permissible operating pressure 8 bar on the medium side. Flow monitor and refrigeration circuit monitoring to protect the plate heat exchanger.
Heat exchanger, external
High-performance condenser made of refrigeration copper tube with positive-locking aluminium fins and optional condenser protection grille.
Refrigeration circuit
Hermetically sealed refrigeration circuit made of refrigeration copper tube. Vibration-damped scroll compressor(s) from the Danfoss DSH compressor series with built-in motor protection switch to protect against overload and overtemperature. Crankcase heater for compressor(s) to heat the oil sump when the unit is at a standstill and at low ambient temperatures as well as to increase the service life as standard. Additional compressor insulation to reduce noise emissions available as an option. Schrader valve accesses on the high and low pressure side enable refrigeration measurements and work without having to open the refrigeration circuit. Pressure sensors on the high and low pressure side for measuring and processing operationally relevant device parameters. Filter dryer with molecular sieve for filtering out the smallest impurities in the refrigeration circuit and drying residual moisture in the refrigerant. Sight glass with humidity indicator for monitoring the acid content of the refrigerant and displaying the aggregate state of the refrigerant upstream of the expansion valve. Preset, electronic expansion valve to increase the control quality and energy efficiency of the chiller.
Use of the innovative and climate-friendly refrigerant R452B of class A2L with a greenhouse gas potential three times lower than comparable refrigerants (comparison R410A).
4-way changeover valve for process reversal from cooling mode to heating mode. Integrated defrost logic for defrosting the finned heat exchanger during heating operation at low outside temperatures.
Fan(s)
Aerodynamically optimised axial fan in EC design with glass fibre-reinforced plastic fins and unique aluminium support structure to minimise noise emissions and maximise efficiency. Fan design in protection class IP 54, insulation class F. Optionally available in AxiTop design to minimise noise emissions.
Working range
Adjustable return temperature range from +5°C to +18°C in cooling mode, +25°C to +50°C in heating mode. Operating range in cooling mode from -15°C to +48°C outside temperature, in heating mode -10°C to +30°C as standard.
Medium circuit
Medium circuit insulated vapour diffusion-tight. Hydraulic circuit can be individually configured, pumps in various pressure levels and integrated medium storage tank as buffer storage to increase the system volume optionally available, see separate tender texts. Medium connections in imperial design with external thread.
Electrics / control
Main switch accessible from the outside on the operating side of the device. Carel pLDPRO controller protected from unauthorised access and the weather by a cover. Hinged enclosure door enables access and opening of the enclosure without having to dismantle housing parts. 3 user levels enable user access to user-relevant device parameters and changes by installers at specialist level. Password-protected manufacturer level for highly sensitive parameter area at programming level. Fully wired and tested main and control circuit including terminal strip for mains supply, phase sequence relay for monitoring the rotating field, load contactors and control relays, transformer and circuit breaker for protection against overload and short-circuit currents. External start/stop contact for switching the device on and off and collective fault signalling contact for external use. Modbus interface RS485 can be retrofitted as an accessory. Fault memory including recording of date and time in the event of a fault for simplified diagnosis. Control cabinet heater integrated as standard to prevent condensation in the control cabinet due to temperature fluctuations at low ambient temperatures. All components are electrically wired and installed in the control cabinet of the appliance.
Other
Rainwater collector pipe and central drainage via screw connections with external thread.
Eco-design directive
Compliance with all requirements of the Ecodesign Directive (EU) 2016/2281 (LOT 21) for chillers for comfort air conditioning in accordance with technical data (see SEER and annual space cooling efficiency ratio).
Available as accessories:
Medium circuit with pump or storage tank and pump in various pressure levels
Glycol
Cable remote control
Condenser protection grille
Vibration damper
Manometer medium circuit
Soft start
Control cabinet ventilation
Modbus interface RS485
Technical unit handover
The units comply with the relevant EU regulations and are CE-marked in accordance with the applicable directives.
Technical performance data:
Type designationREMKO KWP 660 Eco
Nominal cooling capacity, total 1) [kW]66.3
Nominal heating capacity, total 2) [kW]74.4
SEER [--]4.9
Room cooling annual utilisation factor [%]187
Setting range, return temperature, cooling [°C]+5 to +18
Setting range, return temperature, Heating [°C]+25 to +50
Cooling operating range [°C]-15 to +48
Heating operating range [°C]-10 to +30
Compressor, number / type2 / scroll
Capacity gradation [%]0 / 50 / 100
Refrigeration circuits, Number1
RefrigerantR452B
Refrigerant, basic quantity [kg]18.0
CO2 equivalent [t]12.2
Fan, number1
Air volume flow, max. [m³/h]22,000
Sound pressure level 3) [dB(A)]54.7
Sound power level [dB(A)]86.7
Voltage supply [V/~/Hz]400/3~N/50
Protection classIP X4
Electr. rated power consumption cooling 1) [kW]20.1
Electr. Nominal current consumption cooling 1) [A]36.3
Nominal volume flow, medium cooling [m³/h]11.4
Medium connections2 ‘
Outdoor unit dimensions (H/W/D) [mm]2345/1100/1350
Weight [kg]552
Serial colour similar to RAL 9018
1) Air inlet 35°C, medium temperatures 7/12 °C, 0% glycol concentration
2) Air inlet 7°C, medium temperatures 45/40 °C, 0% glycol concentration
3) Distance 10 m free field
Additional information
Product group:
4001
Width (mm):
1100.0MMT
Height (mm):
2345.0MMT
Length (mm):
1350.0MMT
Type:
STD
Related results
Complete catalogs
The offer is aimed exclusively at business customers, companies, public institutions, tradesmen and freelancers. All prices in catalogues are exclusive of VAT, shipping costs and surcharges if applicable.
The manufacturer is exclusively responsible for the content, price and article details of the products and offers presented in the catalogues. Subject to technical and optical changes by the manufacturer and errors excepted.
The manufacturer is exclusively responsible for the content, price and article details of the products and offers presented in the catalogues. Subject to technical and optical changes by the manufacturer and errors excepted.
Matching catalog
Commercial customer offer**
Product suggestions
-4%
Support ring, 1-piece RK 25-50
1104168
€43.87
-19%
ATY 357 Deco IT Arctic
1624572
€552.14
€680.00 MSRP
-14%
Outer casing INOX ELT 10-HT
1101511
€286.85
-13%
Power board 954460 RVS
1106710
€128.53
Accessory pack 1
1106445
€21.67
-13%
Oil pump VM 1
1108498
€189.03
Fan blade 200/31 DZH 20-2
1111663
€25.00
-13%
Condensate drip tray KWK 450/600 (ZW)
1111783
€169.33
-14%
Relay board WP-Manager (WMZ version) CMT 120/160
1120194
€297.69
-4%
Pressure gauge 0-6 bar 1/4?
1108426
€59.16
-19%
RK WP Fresh water station
260182
€4,611.92
€5,680.00 MSRP
-14%
Heating circuit pump HGU/HGM Wilo Stratos PARA 25/1-7 T1
1120909
€372.61
-10%
Condenser board RXT 1401 DC
1111958
€76.39
Side panel housing, right ATY 355 DC AT
1113626
€24.79
-10%
Injection nozzle No. 06 RVS 1600
1107332
€77.22
No Review yet
Description: No Review yet
Written by: No Review
Rating: 5 out of 5
5 stars, based on 1
reviews
Remko RK Klima cold water KWP 660 Eco 1707660
4026415172329
1707660
REMKO GmbH & Co. KG
heating technology
air conditioning technology
room air conditioners
Air-cooled chiller with heat pump function KWP 660 Eco for outdoor installation in high-efficiency design and modular construction
Unit frame
Free-standing base frame made of galvanised sheet steel and heat-treated polyester paint for outdoor installation, standard colour similar to RAL 9018. Removable housing panels allow full access to unit components for increased ease of maintenance.
Heat exchanger, internal
Brazed plate heat exchanger in high-efficiency design made of stainless steel (AISI 316), fully thermally insulated. Maximum permissible operating pressure 8 bar on the medium side. Flow monitor and refrigeration circuit monitoring to protect the plate heat exchanger.
Heat exchanger, external
High-performance condenser made of refrigeration copper tube with positive-locking aluminium fins and optional condenser protection grille.
Refrigeration circuit
Hermetically sealed refrigeration circuit made of refrigeration copper tube. Vibration-damped scroll compressor(s) from the Danfoss DSH compressor series with built-in motor protection switch to protect against overload and overtemperature. Crankcase heater for compressor(s) to heat the oil sump when the unit is at a standstill and at low ambient temperatures as well as to increase the service life as standard. Additional compressor insulation to reduce noise emissions available as an option. Schrader valve accesses on the high and low pressure side enable refrigeration measurements and work without having to open the refrigeration circuit. Pressure sensors on the high and low pressure side for measuring and processing operationally relevant device parameters. Filter dryer with molecular sieve for filtering out the smallest impurities in the refrigeration circuit and drying residual moisture in the refrigerant. Sight glass with humidity indicator for monitoring the acid content of the refrigerant and displaying the aggregate state of the refrigerant upstream of the expansion valve. Preset, electronic expansion valve to increase the control quality and energy efficiency of the chiller.
Use of the innovative and climate-friendly refrigerant R452B of class A2L with a greenhouse gas potential three times lower than comparable refrigerants (comparison R410A).
4-way changeover valve for process reversal from cooling mode to heating mode. Integrated defrost logic for defrosting the finned heat exchanger during heating operation at low outside temperatures.
Fan(s)
Aerodynamically optimised axial fan in EC design with glass fibre-reinforced plastic fins and unique aluminium support structure to minimise noise emissions and maximise efficiency. Fan design in protection class IP 54, insulation class F. Optionally available in AxiTop design to minimise noise emissions.
Working range
Adjustable return temperature range from +5°C to +18°C in cooling mode, +25°C to +50°C in heating mode. Operating range in cooling mode from -15°C to +48°C outside temperature, in heating mode -10°C to +30°C as standard.
Medium circuit
Medium circuit insulated vapour diffusion-tight. Hydraulic circuit can be individually configured, pumps in various pressure levels and integrated medium storage tank as buffer storage to increase the system volume optionally available, see separate tender texts. Medium connections in imperial design with external thread.
Electrics / control
Main switch accessible from the outside on the operating side of the device. Carel pLDPRO controller protected from unauthorised access and the weather by a cover. Hinged enclosure door enables access and opening of the enclosure without having to dismantle housing parts. 3 user levels enable user access to user-relevant device parameters and changes by installers at specialist level. Password-protected manufacturer level for highly sensitive parameter area at programming level. Fully wired and tested main and control circuit including terminal strip for mains supply, phase sequence relay for monitoring the rotating field, load contactors and control relays, transformer and circuit breaker for protection against overload and short-circuit currents. External start/stop contact for switching the device on and off and collective fault signalling contact for external use. Modbus interface RS485 can be retrofitted as an accessory. Fault memory including recording of date and time in the event of a fault for simplified diagnosis. Control cabinet heater integrated as standard to prevent condensation in the control cabinet due to temperature fluctuations at low ambient temperatures. All components are electrically wired and installed in the control cabinet of the appliance.
Other
Rainwater collector pipe and central drainage via screw connections with external thread.
Eco-design directive
Compliance with all requirements of the Ecodesign Directive (EU) 2016/2281 (LOT 21) for chillers for comfort air conditioning in accordance with technical data (see SEER and annual space cooling efficiency ratio).
Available as accessories:
Medium circuit with pump or storage tank and pump in various pressure levels
Glycol
Cable remote control
Condenser protection grille
Vibration damper
Manometer medium circuit
Soft start
Control cabinet ventilation
Modbus interface RS485
Technical unit handover
The units comply with the relevant EU regulations and are CE-marked in accordance with the applicable directives.
Technical performance data:
Type designationREMKO KWP 660 Eco
Nominal cooling capacity, total 1) [kW]66.3
Nominal heating capacity, total 2) [kW]74.4
SEER [--]4.9
Room cooling annual utilisation factor [%]187
Setting range, return temperature, cooling [°C]+5 to +18
Setting range, return temperature, Heating [°C]+25 to +50
Cooling operating range [°C]-15 to +48
Heating operating range [°C]-10 to +30
Compressor, number / type2 / scroll
Capacity gradation [%]0 / 50 / 100
Refrigeration circuits, Number1
RefrigerantR452B
Refrigerant, basic quantity [kg]18.0
CO2 equivalent [t]12.2
Fan, number1
Air volume flow, max. [m³/h]22,000
Sound pressure level 3) [dB(A)]54.7
Sound power level [dB(A)]86.7
Voltage supply [V/~/Hz]400/3~N/50
Protection classIP X4
Electr. rated power consumption cooling 1) [kW]20.1
Electr. Nominal current consumption cooling 1) [A]36.3
Nominal volume flow, medium cooling [m³/h]11.4
Medium connections2 ‘
Outdoor unit dimensions (H/W/D) [mm]2345/1100/1350
Weight [kg]552
Serial colour similar to RAL 9018
1) Air inlet 35°C, medium temperatures 7/12 °C, 0% glycol concentration
2) Air inlet 7°C, medium temperatures 45/40 °C, 0% glycol concentration
3) Distance 10 m free field T-888745 1707660 4026415172329 en ["de","en","it","nl","nl","fr","es","pl","pt","cs","da","sv"] https://www.toolteam.com/en-GB/remko-rk-klima-cold-water-kwp-660-eco-1707660-t-888745-4026415172329?dc=GB&cu=EUR 2026-08-05 27467.73 United Kingdom GB DE 14
Unit frame
Free-standing base frame made of galvanised sheet steel and heat-treated polyester paint for outdoor installation, standard colour similar to RAL 9018. Removable housing panels allow full access to unit components for increased ease of maintenance.
Heat exchanger, internal
Brazed plate heat exchanger in high-efficiency design made of stainless steel (AISI 316), fully thermally insulated. Maximum permissible operating pressure 8 bar on the medium side. Flow monitor and refrigeration circuit monitoring to protect the plate heat exchanger.
Heat exchanger, external
High-performance condenser made of refrigeration copper tube with positive-locking aluminium fins and optional condenser protection grille.
Refrigeration circuit
Hermetically sealed refrigeration circuit made of refrigeration copper tube. Vibration-damped scroll compressor(s) from the Danfoss DSH compressor series with built-in motor protection switch to protect against overload and overtemperature. Crankcase heater for compressor(s) to heat the oil sump when the unit is at a standstill and at low ambient temperatures as well as to increase the service life as standard. Additional compressor insulation to reduce noise emissions available as an option. Schrader valve accesses on the high and low pressure side enable refrigeration measurements and work without having to open the refrigeration circuit. Pressure sensors on the high and low pressure side for measuring and processing operationally relevant device parameters. Filter dryer with molecular sieve for filtering out the smallest impurities in the refrigeration circuit and drying residual moisture in the refrigerant. Sight glass with humidity indicator for monitoring the acid content of the refrigerant and displaying the aggregate state of the refrigerant upstream of the expansion valve. Preset, electronic expansion valve to increase the control quality and energy efficiency of the chiller.
Use of the innovative and climate-friendly refrigerant R452B of class A2L with a greenhouse gas potential three times lower than comparable refrigerants (comparison R410A).
4-way changeover valve for process reversal from cooling mode to heating mode. Integrated defrost logic for defrosting the finned heat exchanger during heating operation at low outside temperatures.
Fan(s)
Aerodynamically optimised axial fan in EC design with glass fibre-reinforced plastic fins and unique aluminium support structure to minimise noise emissions and maximise efficiency. Fan design in protection class IP 54, insulation class F. Optionally available in AxiTop design to minimise noise emissions.
Working range
Adjustable return temperature range from +5°C to +18°C in cooling mode, +25°C to +50°C in heating mode. Operating range in cooling mode from -15°C to +48°C outside temperature, in heating mode -10°C to +30°C as standard.
Medium circuit
Medium circuit insulated vapour diffusion-tight. Hydraulic circuit can be individually configured, pumps in various pressure levels and integrated medium storage tank as buffer storage to increase the system volume optionally available, see separate tender texts. Medium connections in imperial design with external thread.
Electrics / control
Main switch accessible from the outside on the operating side of the device. Carel pLDPRO controller protected from unauthorised access and the weather by a cover. Hinged enclosure door enables access and opening of the enclosure without having to dismantle housing parts. 3 user levels enable user access to user-relevant device parameters and changes by installers at specialist level. Password-protected manufacturer level for highly sensitive parameter area at programming level. Fully wired and tested main and control circuit including terminal strip for mains supply, phase sequence relay for monitoring the rotating field, load contactors and control relays, transformer and circuit breaker for protection against overload and short-circuit currents. External start/stop contact for switching the device on and off and collective fault signalling contact for external use. Modbus interface RS485 can be retrofitted as an accessory. Fault memory including recording of date and time in the event of a fault for simplified diagnosis. Control cabinet heater integrated as standard to prevent condensation in the control cabinet due to temperature fluctuations at low ambient temperatures. All components are electrically wired and installed in the control cabinet of the appliance.
Other
Rainwater collector pipe and central drainage via screw connections with external thread.
Eco-design directive
Compliance with all requirements of the Ecodesign Directive (EU) 2016/2281 (LOT 21) for chillers for comfort air conditioning in accordance with technical data (see SEER and annual space cooling efficiency ratio).
Available as accessories:
Medium circuit with pump or storage tank and pump in various pressure levels
Glycol
Cable remote control
Condenser protection grille
Vibration damper
Manometer medium circuit
Soft start
Control cabinet ventilation
Modbus interface RS485
Technical unit handover
The units comply with the relevant EU regulations and are CE-marked in accordance with the applicable directives.
Technical performance data:
Type designationREMKO KWP 660 Eco
Nominal cooling capacity, total 1) [kW]66.3
Nominal heating capacity, total 2) [kW]74.4
SEER [--]4.9
Room cooling annual utilisation factor [%]187
Setting range, return temperature, cooling [°C]+5 to +18
Setting range, return temperature, Heating [°C]+25 to +50
Cooling operating range [°C]-15 to +48
Heating operating range [°C]-10 to +30
Compressor, number / type2 / scroll
Capacity gradation [%]0 / 50 / 100
Refrigeration circuits, Number1
RefrigerantR452B
Refrigerant, basic quantity [kg]18.0
CO2 equivalent [t]12.2
Fan, number1
Air volume flow, max. [m³/h]22,000
Sound pressure level 3) [dB(A)]54.7
Sound power level [dB(A)]86.7
Voltage supply [V/~/Hz]400/3~N/50
Protection classIP X4
Electr. rated power consumption cooling 1) [kW]20.1
Electr. Nominal current consumption cooling 1) [A]36.3
Nominal volume flow, medium cooling [m³/h]11.4
Medium connections2 ‘
Outdoor unit dimensions (H/W/D) [mm]2345/1100/1350
Weight [kg]552
Serial colour similar to RAL 9018
1) Air inlet 35°C, medium temperatures 7/12 °C, 0% glycol concentration
2) Air inlet 7°C, medium temperatures 45/40 °C, 0% glycol concentration
3) Distance 10 m free field T-888745 1707660 4026415172329 en ["de","en","it","nl","nl","fr","es","pl","pt","cs","da","sv"] https://www.toolteam.com/en-GB/remko-rk-klima-cold-water-kwp-660-eco-1707660-t-888745-4026415172329?dc=GB&cu=EUR 2026-08-05 27467.73 United Kingdom GB DE 14