zoom_in
zoom_out
fullscreen
-19%
Remko KWD 45-4 EC, versatile in use 1612014
Sku: T-1514281
€1,535.76 (excl. legal VAT, excl. Shipping)
€1,890.00 MSRP
In stock,ready for shipping within 24h
Piece
Product variants
| Sku: | Name: | SKU manufacturer: | ||
|---|---|---|---|---|
|
T-383840 | Air conditioning chilled water KWD 25 EC | 1611880 | |
|
T-383841 | Air conditioning chilled water KWD 35 EC | 1611882 | |
|
T-383842 | Air conditioning chilled water KWD 45 EC | 1611884 | |
|
T-383843 | Air conditioning chilled water KWD 55 EC | 1611886 | |
|
T-383844 | Air conditioning chilled water KWD 70 EC | 1611888 | |
|
T-383845 | Air conditioning chilled water KWD 85 EC | 1611890 | |
|
T-383846 | Air conditioning chilled water KWD 100 EC | 1611892 | |
|
T-1514279 | KWD 25-4 EC, versatile in use | 1612010 | |
|
T-1514280 | KWD 35-4 EC, versatile in use | 1612012 | |
|
T-1514282 | KWD 55-4 EC, versatile in use | 1612016 | |
|
T-1514283 | KWD 70-4 EC, versatile in use | 1612018 |
doneNo usage notice required
doneKWD 45-4 EC
doneKWD 45-4 EC
Kaltwasser-Klimasysteme
Content:
1 Piece
Shipping:
€199.92 Versandservice to United Kingdom
plus €39.30 stock transfer surcharge

For orders from €1,000.00 order total plus €34.45 Customs MRN registration
Lieferung:
Provider:
Sales and delivery by ToolTeam Köln
Payment methods:
Returns:
Security:
Product data
Manufacturer:
REMKO GmbH & Co. KG
Condition:
NEW
Sku:
T-1514281
SKU manufacturer:
1612014
GTIN Code (EAN):
4026415191030
Weight:
36,00 Kg
All information relating to products from REMKO GmbH & Co. KG. Technical and optical modifications of the manufacturer and errors reserved.
This page has been machine-translated, the original german version can be found here, please also note the Translation Disclaimer.
Product description
Chilled water ceiling cassette for installation in suspended ceilings with Euroraster dimensions in a four-pipe system with EC fan and operation with standard infrared remote control or optional external controls.
Elegant cover made of white, impact-resistant plastic, similar to RAL 9003. Housing made of dimensionally stable sheet steel, fully insulated. Lateral suspensions for fixing the unit within the suspended ceiling.
Smooth, low-noise centrifugal fan with infinitely variable, electronically controlled and thermally protected EC drive motor, statically and dynamically balanced. Virtually infinitely variable speed control in the range of approx. 20...100% possible for user-specific customisation. The virtually maintenance-free EC motors with permanent magnets enable significantly better efficiency and more constant medium and room temperatures compared to three-stage AC motors, especially in the low speed range. When operated via IR remote control, manual preselection or automatic adjustment of five speeds is possible. When operated via an external controller, three speeds are possible and when operated via a 0...5VDC, alternatively 0...10VDC, control signal, a stepless speed range is possible. This allows the generated power and sound emission to be optimally adapted to the current requirement.
Protection against external influences by grille inside the device.
Air inlet in the centre of the cover with large air intake grille and regenerable air filter behind it.
Air outlet via 4 air outlet openings with automatically or permanently adjustable swing fins, depending on the design.
Air cooler as single circular heat exchanger in Cu/Al design made of seamlessly drawn copper pipe with form-fit aluminium fins for cold or hot water or water/glycol mixture up to max. 70°C. Tightness tested at the factory. Brass pipe connections in imperial design with vent and drain valves on the side of the appliance.
Insulated plastic condensate tray and internal condensate pump with a max. delivery head of 1000mmWS from the lower edge of the appliance. Condensate connection at the side of the unit inside the false ceiling with standard tray of the valve assembly for condensate drainage via the pump.
Connection option for cooling and heating an adjoining room as well as fresh air supply with on-site ducts at the side of the unit inside the false ceiling.
Electrical control box with connection terminals at the side of the unit inside the false ceiling with a power supply of 230V/1~/50Hz, fully wired at the factory in accordance with applicable standards and directives. Terminals and control board with switch blocks for configuration and later functional customisation of the device to a wide range of application requirements.
Inputs for fan control signals 0..5/10V, enable contact for activating or deactivating device operation, selection of the control voltage of external controls, terminals for setting up an internal network and connector strip for connecting a wired remote control (accessory). Potential-free outputs for ‘Heating’ and ‘Cooling’ operating modes, ‘Heating’ and ‘Cooling’ request for activating the valve assembly, as well as a collective fault signalling contact.
As standard, external, on-site controls with three fan stages, external controls with infinitely variable speed control by 0...5 or 0...10VDC or the standard infrared remote control can be used by configuring accordingly.
Operation with external, three-stage control
The fan of the device can be controlled with on-site controls and an operating voltage of 24 or 230VAC in the ‘High’, ‘Medium’ and ‘Low’ stages.
Operation with controls with infinitely variable speed adjustment
With appropriate configuration, the fan can be operated with on-site controls and an optional control voltage of 0...5VDC or 0...10VDC in the speed range of approx. 20...100%.
Operation with IR remote control included in the scope of delivery
The device is operated with a five-stage fan speed in the stages ‘Turbo’, ‘High’, ‘Medium’, ‘Low’ and ‘Silent’ via a handy IR remote control with display. Manual selection of the operating modes ‘Ventilation’, ‘Cooling’, ‘Heating’, ‘Dehumidification’, ‘Timer’, ‘Night boost’ and ‘Automatic’. Fan speed can be preselected manually, automatic speed adjustment to the cooling requirement in automatic mode. Manual operation possible without infrared remote control, with fixed operating states. Restart after power failure. An internal network can be set up with one master device (master) and up to 31 slave devices of different sizes.
The medium volume flow can be controlled by an optional two- or three-way valve assembly with a choice of 24/230VAC control voltage or 0...5/10VDC on the device.
Available as accessories:
Cable remote control, room temperature controls, switching relay for 4 units, fault signal module, external condensate pump, two-way valve assembly, three-way valve assembly
The units comply with the relevant EU regulations and are CE-marked in accordance with the applicable directives.
Technical performance data:
Type designationREMKO KWD 45-4EC
Nominal cooling capacity, total 1) [kW]4.02 kW
Nominal cooling capacity, sensitive 1) [kW]3.23 kW
Nominal heating capacity 3) [kW]4.73 kW
Nominal heating capacity 4) [kW]2.16 kW
Nominal heating capacity 5) [kW]2, 20 kW
Working range, indoor unit [°C]+15 to +35
Air flow rate per stage [m³/h]267/604/705/808/962
Sound pressure level per stage 6) [dB(A)]21/36/38/42/48
Voltage supply [V/~/Hz]230/1/50
Protection classIP X0
Electr. Nominal power consumption [kW]0.06
Nominal electrical current consumption [A]0.49
Operating mediummax. 35% ethylene/propylene glycol
Operating pressure, max, Medium [kPa]1400
Operating limits, medium [°C]+4 to +70
Nominal flow rate, medium cooling 1) [m³/h]0.73
Nominal flow rate, medium heating 2 [m³/h]0.42
Nominal pressure losses, internal cooling 1) [kPa]29.5
Nominal pressure losses, internal heating 2) [kPa]10.5
Medium connections [inch]3/4
Medium capacity, cooling heat exchanger [L]1.21
Medium capacity, heating heat exchanger [L]0.56
Condensate connection [mm]19
Condensate pump, delivery rate, max. [mmWS]1000
Dimensions unit (H/W/D) [mm] 290/570/570
Dimensions cover (H/W/D) [mm]28/650/650
Weight [kg]31.0
1) Room temperature TK 27°C, FK 19°C, medium temperatures 7/12°C, 0% glycol, max. air flow rate
2) Room temperature TK 27°C, FK 19°C, medium temperatures 7/12°C, 0% glycol, max. air flow rate
3) Room temperature TK 27°C, FK 19°C, medium temperatures 7/12°C, 0% glycol, max. air flow rate air volume flow rate
3) Room temperature TK 20°C, medium temperatures 70/60°C, 0% glycol, max. air volume flow rate
4) Room temperature TK 20°C, medium temperatures 50/40°C, 0% glycol, max. air volume flow rate
5) Room temperature TK 20°C, medium temperatures 45/40°C, 0% glycol, max. air volume flow rate
6) Distance 1 m free field
Elegant cover made of white, impact-resistant plastic, similar to RAL 9003. Housing made of dimensionally stable sheet steel, fully insulated. Lateral suspensions for fixing the unit within the suspended ceiling.
Smooth, low-noise centrifugal fan with infinitely variable, electronically controlled and thermally protected EC drive motor, statically and dynamically balanced. Virtually infinitely variable speed control in the range of approx. 20...100% possible for user-specific customisation. The virtually maintenance-free EC motors with permanent magnets enable significantly better efficiency and more constant medium and room temperatures compared to three-stage AC motors, especially in the low speed range. When operated via IR remote control, manual preselection or automatic adjustment of five speeds is possible. When operated via an external controller, three speeds are possible and when operated via a 0...5VDC, alternatively 0...10VDC, control signal, a stepless speed range is possible. This allows the generated power and sound emission to be optimally adapted to the current requirement.
Protection against external influences by grille inside the device.
Air inlet in the centre of the cover with large air intake grille and regenerable air filter behind it.
Air outlet via 4 air outlet openings with automatically or permanently adjustable swing fins, depending on the design.
Air cooler as single circular heat exchanger in Cu/Al design made of seamlessly drawn copper pipe with form-fit aluminium fins for cold or hot water or water/glycol mixture up to max. 70°C. Tightness tested at the factory. Brass pipe connections in imperial design with vent and drain valves on the side of the appliance.
Insulated plastic condensate tray and internal condensate pump with a max. delivery head of 1000mmWS from the lower edge of the appliance. Condensate connection at the side of the unit inside the false ceiling with standard tray of the valve assembly for condensate drainage via the pump.
Connection option for cooling and heating an adjoining room as well as fresh air supply with on-site ducts at the side of the unit inside the false ceiling.
Electrical control box with connection terminals at the side of the unit inside the false ceiling with a power supply of 230V/1~/50Hz, fully wired at the factory in accordance with applicable standards and directives. Terminals and control board with switch blocks for configuration and later functional customisation of the device to a wide range of application requirements.
Inputs for fan control signals 0..5/10V, enable contact for activating or deactivating device operation, selection of the control voltage of external controls, terminals for setting up an internal network and connector strip for connecting a wired remote control (accessory). Potential-free outputs for ‘Heating’ and ‘Cooling’ operating modes, ‘Heating’ and ‘Cooling’ request for activating the valve assembly, as well as a collective fault signalling contact.
As standard, external, on-site controls with three fan stages, external controls with infinitely variable speed control by 0...5 or 0...10VDC or the standard infrared remote control can be used by configuring accordingly.
Operation with external, three-stage control
The fan of the device can be controlled with on-site controls and an operating voltage of 24 or 230VAC in the ‘High’, ‘Medium’ and ‘Low’ stages.
Operation with controls with infinitely variable speed adjustment
With appropriate configuration, the fan can be operated with on-site controls and an optional control voltage of 0...5VDC or 0...10VDC in the speed range of approx. 20...100%.
Operation with IR remote control included in the scope of delivery
The device is operated with a five-stage fan speed in the stages ‘Turbo’, ‘High’, ‘Medium’, ‘Low’ and ‘Silent’ via a handy IR remote control with display. Manual selection of the operating modes ‘Ventilation’, ‘Cooling’, ‘Heating’, ‘Dehumidification’, ‘Timer’, ‘Night boost’ and ‘Automatic’. Fan speed can be preselected manually, automatic speed adjustment to the cooling requirement in automatic mode. Manual operation possible without infrared remote control, with fixed operating states. Restart after power failure. An internal network can be set up with one master device (master) and up to 31 slave devices of different sizes.
The medium volume flow can be controlled by an optional two- or three-way valve assembly with a choice of 24/230VAC control voltage or 0...5/10VDC on the device.
Available as accessories:
Cable remote control, room temperature controls, switching relay for 4 units, fault signal module, external condensate pump, two-way valve assembly, three-way valve assembly
The units comply with the relevant EU regulations and are CE-marked in accordance with the applicable directives.
Technical performance data:
Type designationREMKO KWD 45-4EC
Nominal cooling capacity, total 1) [kW]4.02 kW
Nominal cooling capacity, sensitive 1) [kW]3.23 kW
Nominal heating capacity 3) [kW]4.73 kW
Nominal heating capacity 4) [kW]2.16 kW
Nominal heating capacity 5) [kW]2, 20 kW
Working range, indoor unit [°C]+15 to +35
Air flow rate per stage [m³/h]267/604/705/808/962
Sound pressure level per stage 6) [dB(A)]21/36/38/42/48
Voltage supply [V/~/Hz]230/1/50
Protection classIP X0
Electr. Nominal power consumption [kW]0.06
Nominal electrical current consumption [A]0.49
Operating mediummax. 35% ethylene/propylene glycol
Operating pressure, max, Medium [kPa]1400
Operating limits, medium [°C]+4 to +70
Nominal flow rate, medium cooling 1) [m³/h]0.73
Nominal flow rate, medium heating 2 [m³/h]0.42
Nominal pressure losses, internal cooling 1) [kPa]29.5
Nominal pressure losses, internal heating 2) [kPa]10.5
Medium connections [inch]3/4
Medium capacity, cooling heat exchanger [L]1.21
Medium capacity, heating heat exchanger [L]0.56
Condensate connection [mm]19
Condensate pump, delivery rate, max. [mmWS]1000
Dimensions unit (H/W/D) [mm] 290/570/570
Dimensions cover (H/W/D) [mm]28/650/650
Weight [kg]31.0
1) Room temperature TK 27°C, FK 19°C, medium temperatures 7/12°C, 0% glycol, max. air flow rate
2) Room temperature TK 27°C, FK 19°C, medium temperatures 7/12°C, 0% glycol, max. air flow rate
3) Room temperature TK 27°C, FK 19°C, medium temperatures 7/12°C, 0% glycol, max. air flow rate air volume flow rate
3) Room temperature TK 20°C, medium temperatures 70/60°C, 0% glycol, max. air volume flow rate
4) Room temperature TK 20°C, medium temperatures 50/40°C, 0% glycol, max. air volume flow rate
5) Room temperature TK 20°C, medium temperatures 45/40°C, 0% glycol, max. air volume flow rate
6) Distance 1 m free field
Additional information
Product group:
4
Width (mm):
580.0MMT
Height (mm):
290.0MMT
Type:
STD
Depth (mm):
580.0MMT
Packaging:
PG
Related results
4026415191030
Remko
1612014
REMKO GmbH & Co. KG
Remko
climate
heat
new energies
dehumidification
industrial vacuum cleaners
dehumidifiers
energy efficiency
heating technology
air conditioning systems
environmental technology
pollutant reduction
indoor climate
sustainable energies
commercial dehumidification
Complete catalogs
The offer is aimed exclusively at business customers, companies, public institutions, tradesmen and freelancers. All prices in catalogues are exclusive of VAT, shipping costs and surcharges if applicable.
The manufacturer is exclusively responsible for the content, price and article details of the products and offers presented in the catalogues. Subject to technical and optical changes by the manufacturer and errors excepted.
The manufacturer is exclusively responsible for the content, price and article details of the products and offers presented in the catalogues. Subject to technical and optical changes by the manufacturer and errors excepted.
Product suggestions
-4%
Condensate container ETF/AMT
1104429
€61.09
Fan blade 200/31 DZH 20-2
1111663
€25.00
-14%
Relay board WP-Manager (WMZ version) CMT 120/160
1120194
€297.69
-14%
Outer casing INOX ELT 10-HT
1101511
€286.85
Accessory pack 1
1106445
€21.67
-13%
Oil pump VM 1
1108498
€189.03
-19%
ZA axial fan 501-4
1108376
€808.06
€994.41 MSRP
Condensate nozzle with plug MKT 240/250
1106882
€10.17
-14%
ATY 357 DC IT Deco
1624482
€407.06
-13%
Condensate drip tray KWK 450/600 (ZW)
1111783
€169.33
Oil nozzle 1.75/80 size S DZH 90
1107372
€25.00
-10%
Device cover SKW 520 IT
1113560
€62.51
-19%
RK WP fresh water station
260181
€2,691.25
€3,312.01 MSRP
-4%
Pressure gauge 0-6 bar 1/4?
1108426
€59.16
-4%
Quick coupling suction line BL 263/353 DC AT
1113540
€53.49
No Review yet
Description: No Review yet
Written by: No Review
Rating: 5 out of 5
5 stars, based on 1
reviews
Remko KWD 45-4 EC, versatile in use 1612014
4026415191030
Remko
1612014
REMKO GmbH & Co. KG
Remko
climate
heat
new energies
dehumidification
industrial vacuum cleaners
dehumidifiers
energy efficiency
heating technology
air conditioning systems
environmental technology
pollutant reduction
indoor climate
sustainable energies
commercial dehumidification
Chilled water ceiling cassette for installation in suspended ceilings with Euroraster dimensions in a four-pipe system with EC fan and operation with standard infrared remote control or optional external controls.
Elegant cover made of white, impact-resistant plastic, similar to RAL 9003. Housing made of dimensionally stable sheet steel, fully insulated. Lateral suspensions for fixing the unit within the suspended ceiling.
Smooth, low-noise centrifugal fan with infinitely variable, electronically controlled and thermally protected EC drive motor, statically and dynamically balanced. Virtually infinitely variable speed control in the range of approx. 20...100% possible for user-specific customisation. The virtually maintenance-free EC motors with permanent magnets enable significantly better efficiency and more constant medium and room temperatures compared to three-stage AC motors, especially in the low speed range. When operated via IR remote control, manual preselection or automatic adjustment of five speeds is possible. When operated via an external controller, three speeds are possible and when operated via a 0...5VDC, alternatively 0...10VDC, control signal, a stepless speed range is possible. This allows the generated power and sound emission to be optimally adapted to the current requirement.
Protection against external influences by grille inside the device.
Air inlet in the centre of the cover with large air intake grille and regenerable air filter behind it.
Air outlet via 4 air outlet openings with automatically or permanently adjustable swing fins, depending on the design.
Air cooler as single circular heat exchanger in Cu/Al design made of seamlessly drawn copper pipe with form-fit aluminium fins for cold or hot water or water/glycol mixture up to max. 70°C. Tightness tested at the factory. Brass pipe connections in imperial design with vent and drain valves on the side of the appliance.
Insulated plastic condensate tray and internal condensate pump with a max. delivery head of 1000mmWS from the lower edge of the appliance. Condensate connection at the side of the unit inside the false ceiling with standard tray of the valve assembly for condensate drainage via the pump.
Connection option for cooling and heating an adjoining room as well as fresh air supply with on-site ducts at the side of the unit inside the false ceiling.
Electrical control box with connection terminals at the side of the unit inside the false ceiling with a power supply of 230V/1~/50Hz, fully wired at the factory in accordance with applicable standards and directives. Terminals and control board with switch blocks for configuration and later functional customisation of the device to a wide range of application requirements.
Inputs for fan control signals 0..5/10V, enable contact for activating or deactivating device operation, selection of the control voltage of external controls, terminals for setting up an internal network and connector strip for connecting a wired remote control (accessory). Potential-free outputs for ‘Heating’ and ‘Cooling’ operating modes, ‘Heating’ and ‘Cooling’ request for activating the valve assembly, as well as a collective fault signalling contact.
As standard, external, on-site controls with three fan stages, external controls with infinitely variable speed control by 0...5 or 0...10VDC or the standard infrared remote control can be used by configuring accordingly.
Operation with external, three-stage control
The fan of the device can be controlled with on-site controls and an operating voltage of 24 or 230VAC in the ‘High’, ‘Medium’ and ‘Low’ stages.
Operation with controls with infinitely variable speed adjustment
With appropriate configuration, the fan can be operated with on-site controls and an optional control voltage of 0...5VDC or 0...10VDC in the speed range of approx. 20...100%.
Operation with IR remote control included in the scope of delivery
The device is operated with a five-stage fan speed in the stages ‘Turbo’, ‘High’, ‘Medium’, ‘Low’ and ‘Silent’ via a handy IR remote control with display. Manual selection of the operating modes ‘Ventilation’, ‘Cooling’, ‘Heating’, ‘Dehumidification’, ‘Timer’, ‘Night boost’ and ‘Automatic’. Fan speed can be preselected manually, automatic speed adjustment to the cooling requirement in automatic mode. Manual operation possible without infrared remote control, with fixed operating states. Restart after power failure. An internal network can be set up with one master device (master) and up to 31 slave devices of different sizes.
The medium volume flow can be controlled by an optional two- or three-way valve assembly with a choice of 24/230VAC control voltage or 0...5/10VDC on the device.
Available as accessories:
Cable remote control, room temperature controls, switching relay for 4 units, fault signal module, external condensate pump, two-way valve assembly, three-way valve assembly
The units comply with the relevant EU regulations and are CE-marked in accordance with the applicable directives.
Technical performance data:
Type designationREMKO KWD 45-4EC
Nominal cooling capacity, total 1) [kW]4.02 kW
Nominal cooling capacity, sensitive 1) [kW]3.23 kW
Nominal heating capacity 3) [kW]4.73 kW
Nominal heating capacity 4) [kW]2.16 kW
Nominal heating capacity 5) [kW]2, 20 kW
Working range, indoor unit [°C]+15 to +35
Air flow rate per stage [m³/h]267/604/705/808/962
Sound pressure level per stage 6) [dB(A)]21/36/38/42/48
Voltage supply [V/~/Hz]230/1/50
Protection classIP X0
Electr. Nominal power consumption [kW]0.06
Nominal electrical current consumption [A]0.49
Operating mediummax. 35% ethylene/propylene glycol
Operating pressure, max, Medium [kPa]1400
Operating limits, medium [°C]+4 to +70
Nominal flow rate, medium cooling 1) [m³/h]0.73
Nominal flow rate, medium heating 2 [m³/h]0.42
Nominal pressure losses, internal cooling 1) [kPa]29.5
Nominal pressure losses, internal heating 2) [kPa]10.5
Medium connections [inch]3/4
Medium capacity, cooling heat exchanger [L]1.21
Medium capacity, heating heat exchanger [L]0.56
Condensate connection [mm]19
Condensate pump, delivery rate, max. [mmWS]1000
Dimensions unit (H/W/D) [mm] 290/570/570
Dimensions cover (H/W/D) [mm]28/650/650
Weight [kg]31.0
1) Room temperature TK 27°C, FK 19°C, medium temperatures 7/12°C, 0% glycol, max. air flow rate
2) Room temperature TK 27°C, FK 19°C, medium temperatures 7/12°C, 0% glycol, max. air flow rate
3) Room temperature TK 27°C, FK 19°C, medium temperatures 7/12°C, 0% glycol, max. air flow rate air volume flow rate
3) Room temperature TK 20°C, medium temperatures 70/60°C, 0% glycol, max. air volume flow rate
4) Room temperature TK 20°C, medium temperatures 50/40°C, 0% glycol, max. air volume flow rate
5) Room temperature TK 20°C, medium temperatures 45/40°C, 0% glycol, max. air volume flow rate
6) Distance 1 m free field T-1514281 1612014 4026415191030 en ["de","en","it","nl","nl","fr","es","pl","pt","cs","da","sv"] https://www.toolteam.com/en-GB/remko-kwd-45-4-ec-versatile-in-use-1612014-t-1514281-4026415191030?dc=GB&cu=EUR 2026-07-14 1535.76 United Kingdom GB DE 14
Elegant cover made of white, impact-resistant plastic, similar to RAL 9003. Housing made of dimensionally stable sheet steel, fully insulated. Lateral suspensions for fixing the unit within the suspended ceiling.
Smooth, low-noise centrifugal fan with infinitely variable, electronically controlled and thermally protected EC drive motor, statically and dynamically balanced. Virtually infinitely variable speed control in the range of approx. 20...100% possible for user-specific customisation. The virtually maintenance-free EC motors with permanent magnets enable significantly better efficiency and more constant medium and room temperatures compared to three-stage AC motors, especially in the low speed range. When operated via IR remote control, manual preselection or automatic adjustment of five speeds is possible. When operated via an external controller, three speeds are possible and when operated via a 0...5VDC, alternatively 0...10VDC, control signal, a stepless speed range is possible. This allows the generated power and sound emission to be optimally adapted to the current requirement.
Protection against external influences by grille inside the device.
Air inlet in the centre of the cover with large air intake grille and regenerable air filter behind it.
Air outlet via 4 air outlet openings with automatically or permanently adjustable swing fins, depending on the design.
Air cooler as single circular heat exchanger in Cu/Al design made of seamlessly drawn copper pipe with form-fit aluminium fins for cold or hot water or water/glycol mixture up to max. 70°C. Tightness tested at the factory. Brass pipe connections in imperial design with vent and drain valves on the side of the appliance.
Insulated plastic condensate tray and internal condensate pump with a max. delivery head of 1000mmWS from the lower edge of the appliance. Condensate connection at the side of the unit inside the false ceiling with standard tray of the valve assembly for condensate drainage via the pump.
Connection option for cooling and heating an adjoining room as well as fresh air supply with on-site ducts at the side of the unit inside the false ceiling.
Electrical control box with connection terminals at the side of the unit inside the false ceiling with a power supply of 230V/1~/50Hz, fully wired at the factory in accordance with applicable standards and directives. Terminals and control board with switch blocks for configuration and later functional customisation of the device to a wide range of application requirements.
Inputs for fan control signals 0..5/10V, enable contact for activating or deactivating device operation, selection of the control voltage of external controls, terminals for setting up an internal network and connector strip for connecting a wired remote control (accessory). Potential-free outputs for ‘Heating’ and ‘Cooling’ operating modes, ‘Heating’ and ‘Cooling’ request for activating the valve assembly, as well as a collective fault signalling contact.
As standard, external, on-site controls with three fan stages, external controls with infinitely variable speed control by 0...5 or 0...10VDC or the standard infrared remote control can be used by configuring accordingly.
Operation with external, three-stage control
The fan of the device can be controlled with on-site controls and an operating voltage of 24 or 230VAC in the ‘High’, ‘Medium’ and ‘Low’ stages.
Operation with controls with infinitely variable speed adjustment
With appropriate configuration, the fan can be operated with on-site controls and an optional control voltage of 0...5VDC or 0...10VDC in the speed range of approx. 20...100%.
Operation with IR remote control included in the scope of delivery
The device is operated with a five-stage fan speed in the stages ‘Turbo’, ‘High’, ‘Medium’, ‘Low’ and ‘Silent’ via a handy IR remote control with display. Manual selection of the operating modes ‘Ventilation’, ‘Cooling’, ‘Heating’, ‘Dehumidification’, ‘Timer’, ‘Night boost’ and ‘Automatic’. Fan speed can be preselected manually, automatic speed adjustment to the cooling requirement in automatic mode. Manual operation possible without infrared remote control, with fixed operating states. Restart after power failure. An internal network can be set up with one master device (master) and up to 31 slave devices of different sizes.
The medium volume flow can be controlled by an optional two- or three-way valve assembly with a choice of 24/230VAC control voltage or 0...5/10VDC on the device.
Available as accessories:
Cable remote control, room temperature controls, switching relay for 4 units, fault signal module, external condensate pump, two-way valve assembly, three-way valve assembly
The units comply with the relevant EU regulations and are CE-marked in accordance with the applicable directives.
Technical performance data:
Type designationREMKO KWD 45-4EC
Nominal cooling capacity, total 1) [kW]4.02 kW
Nominal cooling capacity, sensitive 1) [kW]3.23 kW
Nominal heating capacity 3) [kW]4.73 kW
Nominal heating capacity 4) [kW]2.16 kW
Nominal heating capacity 5) [kW]2, 20 kW
Working range, indoor unit [°C]+15 to +35
Air flow rate per stage [m³/h]267/604/705/808/962
Sound pressure level per stage 6) [dB(A)]21/36/38/42/48
Voltage supply [V/~/Hz]230/1/50
Protection classIP X0
Electr. Nominal power consumption [kW]0.06
Nominal electrical current consumption [A]0.49
Operating mediummax. 35% ethylene/propylene glycol
Operating pressure, max, Medium [kPa]1400
Operating limits, medium [°C]+4 to +70
Nominal flow rate, medium cooling 1) [m³/h]0.73
Nominal flow rate, medium heating 2 [m³/h]0.42
Nominal pressure losses, internal cooling 1) [kPa]29.5
Nominal pressure losses, internal heating 2) [kPa]10.5
Medium connections [inch]3/4
Medium capacity, cooling heat exchanger [L]1.21
Medium capacity, heating heat exchanger [L]0.56
Condensate connection [mm]19
Condensate pump, delivery rate, max. [mmWS]1000
Dimensions unit (H/W/D) [mm] 290/570/570
Dimensions cover (H/W/D) [mm]28/650/650
Weight [kg]31.0
1) Room temperature TK 27°C, FK 19°C, medium temperatures 7/12°C, 0% glycol, max. air flow rate
2) Room temperature TK 27°C, FK 19°C, medium temperatures 7/12°C, 0% glycol, max. air flow rate
3) Room temperature TK 27°C, FK 19°C, medium temperatures 7/12°C, 0% glycol, max. air flow rate air volume flow rate
3) Room temperature TK 20°C, medium temperatures 70/60°C, 0% glycol, max. air volume flow rate
4) Room temperature TK 20°C, medium temperatures 50/40°C, 0% glycol, max. air volume flow rate
5) Room temperature TK 20°C, medium temperatures 45/40°C, 0% glycol, max. air volume flow rate
6) Distance 1 m free field T-1514281 1612014 4026415191030 en ["de","en","it","nl","nl","fr","es","pl","pt","cs","da","sv"] https://www.toolteam.com/en-GB/remko-kwd-45-4-ec-versatile-in-use-1612014-t-1514281-4026415191030?dc=GB&cu=EUR 2026-07-14 1535.76 United Kingdom GB DE 14