zoom_in
zoom_out
fullscreen
Remko Air conditioning cold water WLT 85-2 S 1612786
Sku: T-383865
Discontinued item
Product variants
| Sku: | Name: | SKU manufacturer: | ||
|---|---|---|---|---|
|
T-383821 | Air conditioning cold water WLT 25-3 | 1611725 | |
|
T-383822 | Air conditioning cold water WLT 25-3 S | 1611726 | |
|
T-383823 | Air conditioning cold water WLT 27-3 | 1611727 | |
|
T-383824 | Air conditioning cold water WLT 27-3 S | 1611728 | |
|
T-383825 | Air conditioning cold water WLT 45-3 | 1611745 | |
|
T-383826 | Climate chilled water WLT 45-3 S | 1611746 | |
|
T-383827 | Air conditioning chilled water WLT 55-3 | 1611755 | |
|
T-383828 | Air conditioning chilled water WLT 55-3 S | 1611756 | |
|
T-383829 | Air conditioning chilled water WLT 75-3 | 1611775 | |
|
T-383830 | Air conditioning chilled water WLT 75-3 S | 1611776 | |
|
T-383831 | Air conditioning chilled water WLT 85-3 | 1611785 | |
|
T-383832 | Air conditioning chilled water WLT 85-3 S | 1611786 | |
|
T-383854 | Air conditioning cold water WLT 25-2 | 1612725 | |
|
T-383855 | Air conditioning chilled water WLT 25-2 S | 1612726 | |
|
T-383856 | Air conditioning chilled water WLT 27-2 | 1612727 | |
|
T-383857 | Air conditioning chilled water WLT 27-2 S | 1612728 | |
|
T-383858 | Air conditioning chilled water WLT 45-2 | 1612745 | |
|
T-383859 | Air conditioning chilled water WLT 45-2 S | 1612746 | |
|
T-383860 | Air conditioning chilled water WLT 55-2 | 1612755 | |
|
T-383861 | Air conditioning chilled water WLT 55-2 S | 1612756 | |
|
T-383862 | Air conditioning chilled water WLT 75-2 | 1612775 | |
|
T-383863 | Air conditioning chilled water WLT 75-2 S | 1612776 | |
|
T-383864 | Air conditioning chilled water WLT 85-2 | 1612785 |
doneProduct group: 4001
doneType: STD
doneType: STD
Remko Klima cold water WLT 85-2 S 1612786
Product data
Manufacturer:
REMKO GmbH & Co. KG
Condition:
NEW
Sku:
T-383865
SKU manufacturer:
1612786
GTIN Code (EAN):
4026415111632
Weight:
30,10 Kg
All information relating to products from REMKO GmbH & Co. KG. Technical and optical modifications of the manufacturer and errors reserved.
This page has been machine-translated, the original german version can be found here, please also note the Translation Disclaimer.
Product description
Chilled water wall-mounted unit for installation in the upper wall area with built-in two-way valve assembly for connection to external controls in the two-pipe system.
Unit mounted using wall bracket. Housing in a flat, attractive design made of white, impact-resistant plastic.
Air inlet via a generously dimensioned, regenerable air filter. Easy access via the device cover that can be opened at the front. Air outlet via air guide louvre with manually horizontally and vertically adjustable fins.
Air cooler in Cu/Al design made of seamlessly drawn copper pipe with form-fit aluminium fins for cold or hot water or water/glycol mixture up to max. 70 °C. Tightness tested at the factory. Pipe connections in metric copper pipe design. Venting and drain valves in the appliance.
Insulated plastic condensate tray for collecting the condensation water produced on the coil. Condensate connection via flexible pipework at the side, bottom or rear of the unit.
Smooth and quiet tangential fan. Driven by a multi-stage adjustable motor, statically and dynamically balanced.
Electrical connection compartment with connection terminals for three-stage fan motor. Control via room temperature control to be provided by the customer or available as an accessory, or on-site BMS as individual or group control. Restart after power failure.
The medium volume flow is controlled by the standard two-way valve within the device.
Included as standard:
Wall bracket
Two-way valve
Three-speed fan motor
Available as accessories:
Condensate pump
Precision room temperature control
Control unit for up to 4 units
The units comply with the relevant EU regulations and are CE-marked in accordance with the applicable directives.
Technical performance data:
Type designationREMKO WLT 85-2 S
Nominal cooling capacity, total 1) [kW]8.55
Nominal heating capacity 2) [kW]17, 13
Working range indoor unit [°C]+16 to +35
Air volume flow per stage [m³/h]1090/1220/1400
Sound pressure level per stage 3) [dB(A)]39/42/43
Voltage supply [V/~/Hz]230/1/50
Protection classIP X0
Electr. Nominal power consumption [kW]0.09
Nominal electrical current consumption [A]0.41
Operating mediumWater, max. 35% glycol
Operating limits medium K/H [°C]+4 to +20/ +30 to +70
Operating pressure max, Medium [kPa]600
Nominal flow rate, medium [m³/h]1.49
Nominal pressure loss, internal 1) [kPa]33.5
Nominal pressure loss, internal 2) [kPa]27.1
Medium connections [mm]18
Dimensions (H/W/D) [mm]365/1450/215
Weight [kg]25, 1
Colour similar to RAL 9016
1) Room temperature TK 27°C, FK 19°C, medium temperatures 7/12 °C, 0% glycol concentration, max. air volume flow2) Room temperature TK 27°C, FK 19°C, medium temperatures 7/12 °C, 0% glycol concentration, max. air volume flow air volume flow
2) Room temperature TK 20°C, FK 19°C, medium temperatures 70/60 °C, 0% glycol concentration, max. air volume flow
3) Distance 1 m free field
Unit mounted using wall bracket. Housing in a flat, attractive design made of white, impact-resistant plastic.
Air inlet via a generously dimensioned, regenerable air filter. Easy access via the device cover that can be opened at the front. Air outlet via air guide louvre with manually horizontally and vertically adjustable fins.
Air cooler in Cu/Al design made of seamlessly drawn copper pipe with form-fit aluminium fins for cold or hot water or water/glycol mixture up to max. 70 °C. Tightness tested at the factory. Pipe connections in metric copper pipe design. Venting and drain valves in the appliance.
Insulated plastic condensate tray for collecting the condensation water produced on the coil. Condensate connection via flexible pipework at the side, bottom or rear of the unit.
Smooth and quiet tangential fan. Driven by a multi-stage adjustable motor, statically and dynamically balanced.
Electrical connection compartment with connection terminals for three-stage fan motor. Control via room temperature control to be provided by the customer or available as an accessory, or on-site BMS as individual or group control. Restart after power failure.
The medium volume flow is controlled by the standard two-way valve within the device.
Included as standard:
Wall bracket
Two-way valve
Three-speed fan motor
Available as accessories:
Condensate pump
Precision room temperature control
Control unit for up to 4 units
The units comply with the relevant EU regulations and are CE-marked in accordance with the applicable directives.
Technical performance data:
Type designationREMKO WLT 85-2 S
Nominal cooling capacity, total 1) [kW]8.55
Nominal heating capacity 2) [kW]17, 13
Working range indoor unit [°C]+16 to +35
Air volume flow per stage [m³/h]1090/1220/1400
Sound pressure level per stage 3) [dB(A)]39/42/43
Voltage supply [V/~/Hz]230/1/50
Protection classIP X0
Electr. Nominal power consumption [kW]0.09
Nominal electrical current consumption [A]0.41
Operating mediumWater, max. 35% glycol
Operating limits medium K/H [°C]+4 to +20/ +30 to +70
Operating pressure max, Medium [kPa]600
Nominal flow rate, medium [m³/h]1.49
Nominal pressure loss, internal 1) [kPa]33.5
Nominal pressure loss, internal 2) [kPa]27.1
Medium connections [mm]18
Dimensions (H/W/D) [mm]365/1450/215
Weight [kg]25, 1
Colour similar to RAL 9016
1) Room temperature TK 27°C, FK 19°C, medium temperatures 7/12 °C, 0% glycol concentration, max. air volume flow2) Room temperature TK 27°C, FK 19°C, medium temperatures 7/12 °C, 0% glycol concentration, max. air volume flow air volume flow
2) Room temperature TK 20°C, FK 19°C, medium temperatures 70/60 °C, 0% glycol concentration, max. air volume flow
3) Distance 1 m free field
Additional information
Product group:
4001
Width (mm):
1450.0MMT
Height (mm):
365.0MMT
Length (mm):
215.0MMT
Type:
STD
Related results
Complete catalogs
The offer is aimed exclusively at business customers, companies, public institutions, tradesmen and freelancers. All prices in catalogues are exclusive of VAT, shipping costs and surcharges if applicable.
The manufacturer is exclusively responsible for the content, price and article details of the products and offers presented in the catalogues. Subject to technical and optical changes by the manufacturer and errors excepted.
The manufacturer is exclusively responsible for the content, price and article details of the products and offers presented in the catalogues. Subject to technical and optical changes by the manufacturer and errors excepted.
Matching catalog
Commercial customer offer**
Product suggestions
Accessory pack 1
1106445
€21.67
Whirler WKL/VRS 50-60
1102954
€22.14
-19%
Cleaning part AS-RT-D, 180-D
1085058
€705.50
€867.98 MSRP
-14%
ATY 267 Deco
1623430
€445.62
-19%
ZA axial fan 501-4
1108376
€808.06
€994.41 MSRP
-19%
RK WP Fresh water station
260180
€1,830.67
€2,252.98 MSRP
-14%
Control board RVT 681 DC AT
1109849
€453.07
-4%
Side panel, left ATK 25
1103790
€45.50
-10%
Reversing valve RXT 681 DC AT
1111598
€73.78
-4%
Condensate container ETF/AMT
1104429
€61.09
Condensate nozzle RVD 684/MVD 701-1001
1114421
€9.20
-10%
Device cover SKW 520 IT
1113560
€62.51
-13%
Condensate drip tray KWK 450/600 (ZW)
1111783
€169.33
-19%
RK sound insulation hood SWK 4.1,
260938
€1,917.69
€2,360.00 MSRP
Side panel housing, right ATY 355 DC AT
1113626
€24.79
No Review yet
Description: No Review yet
Written by: No Review
Rating: 5 out of 5
5 stars, based on 1
reviews
Remko Air conditioning cold water WLT 85-2 S 1612786
REMKO GmbH & Co. KG 1612786
Remko 1612786
1612786
4026415111632
chilled water air conditioning systems
Chilled water wall-mounted unit for installation in the upper wall area with built-in two-way valve assembly for connection to external controls in the two-pipe system.
Unit mounted using wall bracket. Housing in a flat, attractive design made of white, impact-resistant plastic.
Air inlet via a generously dimensioned, regenerable air filter. Easy access via the device cover that can be opened at the front. Air outlet via air guide louvre with manually horizontally and vertically adjustable fins.
Air cooler in Cu/Al design made of seamlessly drawn copper pipe with form-fit aluminium fins for cold or hot water or water/glycol mixture up to max. 70 °C. Tightness tested at the factory. Pipe connections in metric copper pipe design. Venting and drain valves in the appliance.
Insulated plastic condensate tray for collecting the condensation water produced on the coil. Condensate connection via flexible pipework at the side, bottom or rear of the unit.
Smooth and quiet tangential fan. Driven by a multi-stage adjustable motor, statically and dynamically balanced.
Electrical connection compartment with connection terminals for three-stage fan motor. Control via room temperature control to be provided by the customer or available as an accessory, or on-site BMS as individual or group control. Restart after power failure.
The medium volume flow is controlled by the standard two-way valve within the device.
Included as standard:
Wall bracket
Two-way valve
Three-speed fan motor
Available as accessories:
Condensate pump
Precision room temperature control
Control unit for up to 4 units
The units comply with the relevant EU regulations and are CE-marked in accordance with the applicable directives.
Technical performance data:
Type designationREMKO WLT 85-2 S
Nominal cooling capacity, total 1) [kW]8.55
Nominal heating capacity 2) [kW]17, 13
Working range indoor unit [°C]+16 to +35
Air volume flow per stage [m³/h]1090/1220/1400
Sound pressure level per stage 3) [dB(A)]39/42/43
Voltage supply [V/~/Hz]230/1/50
Protection classIP X0
Electr. Nominal power consumption [kW]0.09
Nominal electrical current consumption [A]0.41
Operating mediumWater, max. 35% glycol
Operating limits medium K/H [°C]+4 to +20/ +30 to +70
Operating pressure max, Medium [kPa]600
Nominal flow rate, medium [m³/h]1.49
Nominal pressure loss, internal 1) [kPa]33.5
Nominal pressure loss, internal 2) [kPa]27.1
Medium connections [mm]18
Dimensions (H/W/D) [mm]365/1450/215
Weight [kg]25, 1
Colour similar to RAL 9016
1) Room temperature TK 27°C, FK 19°C, medium temperatures 7/12 °C, 0% glycol concentration, max. air volume flow2) Room temperature TK 27°C, FK 19°C, medium temperatures 7/12 °C, 0% glycol concentration, max. air volume flow air volume flow
2) Room temperature TK 20°C, FK 19°C, medium temperatures 70/60 °C, 0% glycol concentration, max. air volume flow
3) Distance 1 m free field T-383865 1612786 4026415111632 en ["de","en","it","nl","nl","fr","es","pl","pt","cs","da","sv"] https://www.toolteam.com/en-GB/remko-air-conditioning-cold-water-wlt-85-2-s-1612786-t-383865-4026415111632?dc=GB&cu=EUR 2026-08-04 1714.58 United Kingdom GB DE 14
Unit mounted using wall bracket. Housing in a flat, attractive design made of white, impact-resistant plastic.
Air inlet via a generously dimensioned, regenerable air filter. Easy access via the device cover that can be opened at the front. Air outlet via air guide louvre with manually horizontally and vertically adjustable fins.
Air cooler in Cu/Al design made of seamlessly drawn copper pipe with form-fit aluminium fins for cold or hot water or water/glycol mixture up to max. 70 °C. Tightness tested at the factory. Pipe connections in metric copper pipe design. Venting and drain valves in the appliance.
Insulated plastic condensate tray for collecting the condensation water produced on the coil. Condensate connection via flexible pipework at the side, bottom or rear of the unit.
Smooth and quiet tangential fan. Driven by a multi-stage adjustable motor, statically and dynamically balanced.
Electrical connection compartment with connection terminals for three-stage fan motor. Control via room temperature control to be provided by the customer or available as an accessory, or on-site BMS as individual or group control. Restart after power failure.
The medium volume flow is controlled by the standard two-way valve within the device.
Included as standard:
Wall bracket
Two-way valve
Three-speed fan motor
Available as accessories:
Condensate pump
Precision room temperature control
Control unit for up to 4 units
The units comply with the relevant EU regulations and are CE-marked in accordance with the applicable directives.
Technical performance data:
Type designationREMKO WLT 85-2 S
Nominal cooling capacity, total 1) [kW]8.55
Nominal heating capacity 2) [kW]17, 13
Working range indoor unit [°C]+16 to +35
Air volume flow per stage [m³/h]1090/1220/1400
Sound pressure level per stage 3) [dB(A)]39/42/43
Voltage supply [V/~/Hz]230/1/50
Protection classIP X0
Electr. Nominal power consumption [kW]0.09
Nominal electrical current consumption [A]0.41
Operating mediumWater, max. 35% glycol
Operating limits medium K/H [°C]+4 to +20/ +30 to +70
Operating pressure max, Medium [kPa]600
Nominal flow rate, medium [m³/h]1.49
Nominal pressure loss, internal 1) [kPa]33.5
Nominal pressure loss, internal 2) [kPa]27.1
Medium connections [mm]18
Dimensions (H/W/D) [mm]365/1450/215
Weight [kg]25, 1
Colour similar to RAL 9016
1) Room temperature TK 27°C, FK 19°C, medium temperatures 7/12 °C, 0% glycol concentration, max. air volume flow2) Room temperature TK 27°C, FK 19°C, medium temperatures 7/12 °C, 0% glycol concentration, max. air volume flow air volume flow
2) Room temperature TK 20°C, FK 19°C, medium temperatures 70/60 °C, 0% glycol concentration, max. air volume flow
3) Distance 1 m free field T-383865 1612786 4026415111632 en ["de","en","it","nl","nl","fr","es","pl","pt","cs","da","sv"] https://www.toolteam.com/en-GB/remko-air-conditioning-cold-water-wlt-85-2-s-1612786-t-383865-4026415111632?dc=GB&cu=EUR 2026-08-04 1714.58 United Kingdom GB DE 14