zoom_in
zoom_out
fullscreen
Remko Air conditioning cold water KWP 2955 SLN 1703460
Sku: T-384891
Discontinued item
Product variants
| Sku: | Name: | SKU manufacturer: | ||
|---|---|---|---|---|
|
T-384884 | Air conditioning cold water KWP 2655 | 1703425 | |
|
T-384885 | Air conditioning cold water KWP 2955 | 1703430 | |
|
T-384886 | Air conditioning cold water KWP 3305 | 1703435 | |
|
T-384889 | Air conditioning cold water KWP 2305 SLN | 1703450 | |
|
T-384890 | Air conditioning cold water KWP 2655 SLN | 1703455 |
doneProduct group: 4001
doneDepth: 5120mm
doneDepth: 5120mm
doneType: STD
Remko air conditioning chilled water KWP 2955 SLN 1703460
Product data
Manufacturer:
REMKO GmbH & Co. KG
Condition:
NEW
Sku:
T-384891
SKU manufacturer:
1703460
GTIN Code (EAN):
4026415135614
Weight:
2531,00 Kg
All information relating to products from REMKO GmbH & Co. KG. Technical and optical modifications of the manufacturer and errors reserved.
This page has been machine-translated, the original german version can be found here, please also note the Translation Disclaimer.
Product description
Chiller with heat pump function in compact design for outdoor installation in noise-reduced design, ready for connection, air-cooled. Weather-resistant base frame with removable cladding panels made of powder-coated sheet steel, colour similar to RAL 9018. Separate condenser and sound-insulated compressor compartment. Horizontal air inlet via large-area high-performance condenser (cooling mode) in straight design made of refrigeration copper pipe with form-fit aluminium fins. Vertical air outlet via particularly slow-running, flow-optimised, statically and dynamically balanced axial fan(s) with protective cage. Standard operating limits in cooling mode between +45°C and +5°C, range can be extended to -15°C 6) with winter pressure control accessory. Standard operating limits in heating mode between -10°C and +20°C. Four fully hermetic, vibration-damped scroll compressors with refrigerating machine oil filling, optimally controlled according to the operating times. Two refrigerant circuits made of refrigeration copper pipe, hermetically sealed and pressure-tested at the factory, dried and filled with R 410 A safety refrigerant. Control option via Schrader valve. High and low pressure monitors, pressure transmitters on the high and low pressure side, filter dryer and thermostatic expansion valve with external pressure equalisation. Integrated four-way reversing valve for switching between cooling and heating mode. Evaporator as refrigerant-water heat exchanger in brazed plate design made of stainless steel, vapour diffusion-tight insulation, return temperature range from +18°C to +10°C in cooling mode and from +45°C to +20°C in heating mode. Insulated medium circuit for water-glycol mixtures made of steel pipe with filling and draining connection, manual vent valve and differential pressure switch for monitoring the volume flow. Medium connections in imperial Vitaulic design.
Control box with terminal strip for mains supply, potential-free input for external release, potential-free output for collective fault signal and connection of a cable remote control. Fully wired and tested main and control circuit with phase sequence relay, circuit breaker, fuses, contactors for main and control circuits and transformers fitted as standard. Automatic restart after power failure.
Easily accessible microprocessor controller with RS485 and USB interface for independent monitoring and control of all operating functions, protected from environmental influences and based on Linux. User-friendly display of all control parameters and coded fault messages within a value and parameter display, e.g. medium inlet and outlet temperatures, operating pressures in the refrigeration circuit. Function display of the operating modes, fan, compressors, circulation pump and collective fault. Operation of the device using six operating buttons. Three password-protected parameter areas available.
Regional regulations and ordinances or environmental protection laws, e.g. WHG, must be taken into account when planning and installing the appliances.
Available as accessories:
Cable remote control, vibration damper, condenser protection grille, crankcase heater, winter pressure control, frost protection heating medium, heat recovery. Technical unit transfer for optimum adjustment of the chiller on the system.
The units comply with the relevant EU regulations and are CE-marked in accordance with the applicable directives.
Technical performance data:
MakeREMKO
TypeKWP 2955 SLN
Nominal cooling capacity, total 1) [kW]282.1
Nominal heating capacity 2) [kW]348.9
Energy efficiency parameter cooling EER 1)2.66
Energy efficiency parameter heating COP 2)4.05
Setting range, return temperature cooling [°C]+10 to +18
Setting range, Return temperature, heating [°C]+30 to +45
Working range, cooling 6)/heating [°C]-15 to +45/-10 to +20
Capacity grading0/23/50/73/100
Refrigerant 7)R 410 A
Compressor, number/type4/Scroll
Fan, number6
Air flow rate, max. [m³/h]99,600
Sound pressure level, max. 3) [dB(A)]58.6
Sound power level [dB(A)]86.8
Voltage supply [V/~/Hz]400/3/50
Protection classIP 24
Electr. Power consumption max. 4) [kW]177.62
Electr. current consumption max. 4) [A]258.65
Electr. rated power consumption cooling 1) [kW]106.89
Electr. rated current consumption cooling 1) [A]208.73
Electr. rated power consumption heating 2) [kW]86.83
Electr. rated current consumption heating 2) [A]169.55
Electr. Starting current, max. LRA [A]481
Nominal volume flow, medium cooling [m³/h]60.01
Nominal pressure losses, internal cooling [kPa]65.8
Medium connections4”
Minimum medium volume system [l]360.0
Dimensions (H/W/D) [mm]2270/2205/5120
Weight [kg]2664.0
Operating weight approx. [kg]3383.8
1) Air inlet 35°C, medium temperatures 7/12°C, 0% glycol
2) Air inlet 7°C, medium temperatures 35/30°C, 0% glycol
3) Distance 10 m free field
4) Air inlet 45°C, medium temperatures 18/15°C, 0% glycol
5) Only with compressor crankcase heater accessory
6) Only with winter pressure control accessory
7) Contains greenhouse gas in accordance with the Kyoto Protocol
Control box with terminal strip for mains supply, potential-free input for external release, potential-free output for collective fault signal and connection of a cable remote control. Fully wired and tested main and control circuit with phase sequence relay, circuit breaker, fuses, contactors for main and control circuits and transformers fitted as standard. Automatic restart after power failure.
Easily accessible microprocessor controller with RS485 and USB interface for independent monitoring and control of all operating functions, protected from environmental influences and based on Linux. User-friendly display of all control parameters and coded fault messages within a value and parameter display, e.g. medium inlet and outlet temperatures, operating pressures in the refrigeration circuit. Function display of the operating modes, fan, compressors, circulation pump and collective fault. Operation of the device using six operating buttons. Three password-protected parameter areas available.
Regional regulations and ordinances or environmental protection laws, e.g. WHG, must be taken into account when planning and installing the appliances.
Available as accessories:
Cable remote control, vibration damper, condenser protection grille, crankcase heater, winter pressure control, frost protection heating medium, heat recovery. Technical unit transfer for optimum adjustment of the chiller on the system.
The units comply with the relevant EU regulations and are CE-marked in accordance with the applicable directives.
Technical performance data:
MakeREMKO
TypeKWP 2955 SLN
Nominal cooling capacity, total 1) [kW]282.1
Nominal heating capacity 2) [kW]348.9
Energy efficiency parameter cooling EER 1)2.66
Energy efficiency parameter heating COP 2)4.05
Setting range, return temperature cooling [°C]+10 to +18
Setting range, Return temperature, heating [°C]+30 to +45
Working range, cooling 6)/heating [°C]-15 to +45/-10 to +20
Capacity grading0/23/50/73/100
Refrigerant 7)R 410 A
Compressor, number/type4/Scroll
Fan, number6
Air flow rate, max. [m³/h]99,600
Sound pressure level, max. 3) [dB(A)]58.6
Sound power level [dB(A)]86.8
Voltage supply [V/~/Hz]400/3/50
Protection classIP 24
Electr. Power consumption max. 4) [kW]177.62
Electr. current consumption max. 4) [A]258.65
Electr. rated power consumption cooling 1) [kW]106.89
Electr. rated current consumption cooling 1) [A]208.73
Electr. rated power consumption heating 2) [kW]86.83
Electr. rated current consumption heating 2) [A]169.55
Electr. Starting current, max. LRA [A]481
Nominal volume flow, medium cooling [m³/h]60.01
Nominal pressure losses, internal cooling [kPa]65.8
Medium connections4”
Minimum medium volume system [l]360.0
Dimensions (H/W/D) [mm]2270/2205/5120
Weight [kg]2664.0
Operating weight approx. [kg]3383.8
1) Air inlet 35°C, medium temperatures 7/12°C, 0% glycol
2) Air inlet 7°C, medium temperatures 35/30°C, 0% glycol
3) Distance 10 m free field
4) Air inlet 45°C, medium temperatures 18/15°C, 0% glycol
5) Only with compressor crankcase heater accessory
6) Only with winter pressure control accessory
7) Contains greenhouse gas in accordance with the Kyoto Protocol
Additional information
Product group:
4001
Depth:
5120mm
Width (mm):
2205.0MMT
Height (mm):
2270.0MMT
Length (mm):
5120.0MMT
Type:
STD
Related results
Complete catalogs
The offer is aimed exclusively at business customers, companies, public institutions, tradesmen and freelancers. All prices in catalogues are exclusive of VAT, shipping costs and surcharges if applicable.
The manufacturer is exclusively responsible for the content, price and article details of the products and offers presented in the catalogues. Subject to technical and optical changes by the manufacturer and errors excepted.
The manufacturer is exclusively responsible for the content, price and article details of the products and offers presented in the catalogues. Subject to technical and optical changes by the manufacturer and errors excepted.
Matching catalog
Commercial customer offer**
Product suggestions
-4%
Insert (Vent. plug)
1108317
€33.95
-13%
Power board 954460 RVS
1106710
€128.53
Side panel housing, right ATY 355 DC AT
1113626
€24.79
Oil nozzle 2.25/60 degree S
1102823
€23.82
-13%
Oil pump AD1L2 Replacement for V1-LR2 1/4?
1108640
€159.20
-10%
Device cover SKW 520 IT
1113560
€62.51
-14%
ATY 527 DC IT Deco
1624492
€531.30
Fan blade 200/31 DZH 20-2
1111663
€25.00
-4%
Housing front BL 353 DC IT/SKW 350 DC IT
1113452
€63.32
Condensate nozzle with plug MKT 240/250
1106882
€10.17
Relay Board Merlin CMF/CMT-New version
1120030-N
€396.93
Mounting plate shut-off valve RVT 263 DC AT
1112422
€15.25
-10%
Injection nozzle No. 06 RVS 1600
1107332
€77.22
-19%
RK sound insulation hood SWK 5.1,
260939
€2,015.21
€2,480.00 MSRP
-19%
RK WP Fresh water station
260180
€1,830.67
€2,252.98 MSRP
No Review yet
Description: No Review yet
Written by: No Review
Rating: 5 out of 5
5 stars, based on 1
reviews
Remko Air conditioning cold water KWP 2955 SLN 1703460
REMKO GmbH & Co. KG 1703460
Remko 1703460
1703460
4026415135614
chilled water air conditioning systems
Chiller with heat pump function in compact design for outdoor installation in noise-reduced design, ready for connection, air-cooled. Weather-resistant base frame with removable cladding panels made of powder-coated sheet steel, colour similar to RAL 9018. Separate condenser and sound-insulated compressor compartment. Horizontal air inlet via large-area high-performance condenser (cooling mode) in straight design made of refrigeration copper pipe with form-fit aluminium fins. Vertical air outlet via particularly slow-running, flow-optimised, statically and dynamically balanced axial fan(s) with protective cage. Standard operating limits in cooling mode between +45°C and +5°C, range can be extended to -15°C 6) with winter pressure control accessory. Standard operating limits in heating mode between -10°C and +20°C. Four fully hermetic, vibration-damped scroll compressors with refrigerating machine oil filling, optimally controlled according to the operating times. Two refrigerant circuits made of refrigeration copper pipe, hermetically sealed and pressure-tested at the factory, dried and filled with R 410 A safety refrigerant. Control option via Schrader valve. High and low pressure monitors, pressure transmitters on the high and low pressure side, filter dryer and thermostatic expansion valve with external pressure equalisation. Integrated four-way reversing valve for switching between cooling and heating mode. Evaporator as refrigerant-water heat exchanger in brazed plate design made of stainless steel, vapour diffusion-tight insulation, return temperature range from +18°C to +10°C in cooling mode and from +45°C to +20°C in heating mode. Insulated medium circuit for water-glycol mixtures made of steel pipe with filling and draining connection, manual vent valve and differential pressure switch for monitoring the volume flow. Medium connections in imperial Vitaulic design.
Control box with terminal strip for mains supply, potential-free input for external release, potential-free output for collective fault signal and connection of a cable remote control. Fully wired and tested main and control circuit with phase sequence relay, circuit breaker, fuses, contactors for main and control circuits and transformers fitted as standard. Automatic restart after power failure.
Easily accessible microprocessor controller with RS485 and USB interface for independent monitoring and control of all operating functions, protected from environmental influences and based on Linux. User-friendly display of all control parameters and coded fault messages within a value and parameter display, e.g. medium inlet and outlet temperatures, operating pressures in the refrigeration circuit. Function display of the operating modes, fan, compressors, circulation pump and collective fault. Operation of the device using six operating buttons. Three password-protected parameter areas available.
Regional regulations and ordinances or environmental protection laws, e.g. WHG, must be taken into account when planning and installing the appliances.
Available as accessories:
Cable remote control, vibration damper, condenser protection grille, crankcase heater, winter pressure control, frost protection heating medium, heat recovery. Technical unit transfer for optimum adjustment of the chiller on the system.
The units comply with the relevant EU regulations and are CE-marked in accordance with the applicable directives.
Technical performance data:
MakeREMKO
TypeKWP 2955 SLN
Nominal cooling capacity, total 1) [kW]282.1
Nominal heating capacity 2) [kW]348.9
Energy efficiency parameter cooling EER 1)2.66
Energy efficiency parameter heating COP 2)4.05
Setting range, return temperature cooling [°C]+10 to +18
Setting range, Return temperature, heating [°C]+30 to +45
Working range, cooling 6)/heating [°C]-15 to +45/-10 to +20
Capacity grading0/23/50/73/100
Refrigerant 7)R 410 A
Compressor, number/type4/Scroll
Fan, number6
Air flow rate, max. [m³/h]99,600
Sound pressure level, max. 3) [dB(A)]58.6
Sound power level [dB(A)]86.8
Voltage supply [V/~/Hz]400/3/50
Protection classIP 24
Electr. Power consumption max. 4) [kW]177.62
Electr. current consumption max. 4) [A]258.65
Electr. rated power consumption cooling 1) [kW]106.89
Electr. rated current consumption cooling 1) [A]208.73
Electr. rated power consumption heating 2) [kW]86.83
Electr. rated current consumption heating 2) [A]169.55
Electr. Starting current, max. LRA [A]481
Nominal volume flow, medium cooling [m³/h]60.01
Nominal pressure losses, internal cooling [kPa]65.8
Medium connections4”
Minimum medium volume system [l]360.0
Dimensions (H/W/D) [mm]2270/2205/5120
Weight [kg]2664.0
Operating weight approx. [kg]3383.8
1) Air inlet 35°C, medium temperatures 7/12°C, 0% glycol
2) Air inlet 7°C, medium temperatures 35/30°C, 0% glycol
3) Distance 10 m free field
4) Air inlet 45°C, medium temperatures 18/15°C, 0% glycol
5) Only with compressor crankcase heater accessory
6) Only with winter pressure control accessory
7) Contains greenhouse gas in accordance with the Kyoto Protocol T-384891 1703460 4026415135614 en ["de","en","it","nl","nl","fr","es","pl","pt","cs","da","sv"] https://www.toolteam.com/en-GB/remko-air-conditioning-cold-water-kwp-2955-sln-1703460-t-384891-4026415135614?dc=GB&cu=EUR 2026-08-08 86794.96 United Kingdom GB DE 14
Control box with terminal strip for mains supply, potential-free input for external release, potential-free output for collective fault signal and connection of a cable remote control. Fully wired and tested main and control circuit with phase sequence relay, circuit breaker, fuses, contactors for main and control circuits and transformers fitted as standard. Automatic restart after power failure.
Easily accessible microprocessor controller with RS485 and USB interface for independent monitoring and control of all operating functions, protected from environmental influences and based on Linux. User-friendly display of all control parameters and coded fault messages within a value and parameter display, e.g. medium inlet and outlet temperatures, operating pressures in the refrigeration circuit. Function display of the operating modes, fan, compressors, circulation pump and collective fault. Operation of the device using six operating buttons. Three password-protected parameter areas available.
Regional regulations and ordinances or environmental protection laws, e.g. WHG, must be taken into account when planning and installing the appliances.
Available as accessories:
Cable remote control, vibration damper, condenser protection grille, crankcase heater, winter pressure control, frost protection heating medium, heat recovery. Technical unit transfer for optimum adjustment of the chiller on the system.
The units comply with the relevant EU regulations and are CE-marked in accordance with the applicable directives.
Technical performance data:
MakeREMKO
TypeKWP 2955 SLN
Nominal cooling capacity, total 1) [kW]282.1
Nominal heating capacity 2) [kW]348.9
Energy efficiency parameter cooling EER 1)2.66
Energy efficiency parameter heating COP 2)4.05
Setting range, return temperature cooling [°C]+10 to +18
Setting range, Return temperature, heating [°C]+30 to +45
Working range, cooling 6)/heating [°C]-15 to +45/-10 to +20
Capacity grading0/23/50/73/100
Refrigerant 7)R 410 A
Compressor, number/type4/Scroll
Fan, number6
Air flow rate, max. [m³/h]99,600
Sound pressure level, max. 3) [dB(A)]58.6
Sound power level [dB(A)]86.8
Voltage supply [V/~/Hz]400/3/50
Protection classIP 24
Electr. Power consumption max. 4) [kW]177.62
Electr. current consumption max. 4) [A]258.65
Electr. rated power consumption cooling 1) [kW]106.89
Electr. rated current consumption cooling 1) [A]208.73
Electr. rated power consumption heating 2) [kW]86.83
Electr. rated current consumption heating 2) [A]169.55
Electr. Starting current, max. LRA [A]481
Nominal volume flow, medium cooling [m³/h]60.01
Nominal pressure losses, internal cooling [kPa]65.8
Medium connections4”
Minimum medium volume system [l]360.0
Dimensions (H/W/D) [mm]2270/2205/5120
Weight [kg]2664.0
Operating weight approx. [kg]3383.8
1) Air inlet 35°C, medium temperatures 7/12°C, 0% glycol
2) Air inlet 7°C, medium temperatures 35/30°C, 0% glycol
3) Distance 10 m free field
4) Air inlet 45°C, medium temperatures 18/15°C, 0% glycol
5) Only with compressor crankcase heater accessory
6) Only with winter pressure control accessory
7) Contains greenhouse gas in accordance with the Kyoto Protocol T-384891 1703460 4026415135614 en ["de","en","it","nl","nl","fr","es","pl","pt","cs","da","sv"] https://www.toolteam.com/en-GB/remko-air-conditioning-cold-water-kwp-2955-sln-1703460-t-384891-4026415135614?dc=GB&cu=EUR 2026-08-08 86794.96 United Kingdom GB DE 14