zoom_in
zoom_out
fullscreen
Remko Air conditioning cold water KWP 2105 1703415
Sku: T-384882
Discontinued item
Product variants
| Sku: | Name: | SKU manufacturer: | ||
|---|---|---|---|---|
|
T-384881 | Air conditioning cold water KWP 1905 | 1703410 | |
|
T-384883 | Air conditioning cold water KWP 2305 | 1703420 | |
|
T-384887 | Air conditioning cold water KWP 1905 SLN | 1703440 | |
|
T-384888 | Air conditioning cold water KWP 2105 SLN | 1703445 |
doneProduct group: 4001
doneDepth: 4118mm
doneDepth: 4118mm
doneType: STD
Remko Klima cold water KWP 2105 1703415
Product data
Manufacturer:
REMKO GmbH & Co. KG
Condition:
NEW
Sku:
T-384882
SKU manufacturer:
1703415
GTIN Code (EAN):
4026415135430
Weight:
1848,30 Kg
All information relating to products from REMKO GmbH & Co. KG. Technical and optical modifications of the manufacturer and errors reserved.
This page has been machine-translated, the original german version can be found here, please also note the Translation Disclaimer.
Product description
Chiller with heat pump function in compact design for outdoor installation, ready for connection, air-cooled.
Weather-resistant base frame with removable cladding panels made of powder-coated sheet steel, colour similar to RAL 9018. Condenser and sound-insulated compressor compartment separated from each other.
Air inlet horizontal via large-area high-performance condenser (cooling mode) in straight design made of refrigeration copper pipe with form-fit aluminium fins. Vertical air outlet via flow-optimised, statically and dynamically balanced axial fan(s) with protective cage. Standard operating limits in cooling mode between +45°C and +5°C, range extension with winter pressure control accessory down to -15°C 6 possible. Standard operating limits in heating mode between -10°C to +20°C.
Six fully hermetic, vibration-damped scroll compressors with refrigerating machine oil filling, optimally controlled according to the operating times.
Two refrigerant circuits made of refrigeration copper pipe, hermetically sealed and pressure-tested at the factory, dried and filled with safety refrigerant R 410A. Control option via Schrader valve. High and low pressure monitors, pressure transmitters on the high and low pressure side, filter dryer and thermostatic expansion valve with external pressure equalisation. Integrated four-way reversing valve for switching between cooling and heating mode. Evaporator as refrigerant/water heat exchanger in brazed plate design made of stainless steel, vapour diffusion-tight insulation, return temperature range from +18°C to +10°C in cooling mode and from +45°C to +30°C in heating mode.
Insulated medium circuit for water/glycol mixtures made of steel pipe with filling and draining connection, manual air vent valve and differential pressure switch for monitoring the volume flow. Medium connections in imperial Vitaulic design.
Control box with terminal strip for mains supply, potential-free input for external release, potential-free output for collective fault signal and connection of a cable remote control. Fully wired and tested main and control circuit with phase sequence relay, circuit breaker, fuses, contactors for main and control circuits and transformers fitted as standard. Automatic restart after power failure.
Easily accessible microprocessor controller with RS485 and USB interface for independent monitoring and control of all operating functions, protected from environmental influences and based on Linux. User-friendly display of all control parameters and coded fault messages within a value and parameter display, e.g. medium inlet and outlet temperatures, operating pressures in the refrigeration circuit. Function display of the operating modes, fan, compressors, circulation pump and collective fault.
Operation of the device using six operating buttons. Three password-protected parameter areas available.
Regional regulations, ordinances or environmental protection laws, e.g. WHG, must be taken into account when planning and installing the appliances.
Available as accessories:
Cable remote control, vibration damper, condenser protection grille, crankcase heater, winter pressure control, frost protection heating medium, heat recovery.
Technical unit transfer for optimum adjustment of the chiller on the system.
The units comply with the relevant EU regulations and are CE-marked in accordance with the applicable directives.
Technical performance data:
Type designationREMKO KWP 2105
Nominal cooling capacity, total 1200.42 kW
Nominal heating capacity 2248.22 kW
Energy efficiency parameter cooling EER 12.59
Energy efficiency parameter heating COP 23.83
Adjustment range, return temperature cooling+10 to +18 °C
Adjustment range, Return temperature, heating+30 to +45 °C
Cooling operating range 6-15 to +45 °C
Heating operating range +20 to +35°C
Capacity grading0/16/32/50/66/82/100
Refrigerant 7R 410A
Compressor, number / type6 / scroll
Fan, number4
Air flow rate, max. 85400 m³/h
Sound pressure level, max. 357.7 dB(A)
Sound power level85.7 dB(A)
Power supply400V/3~/50 Hz
Protection classIP 24
Electr. power consumption max. 491.46 kW
Electr. Current consumption max. 4189.99 A
Electr. rated power consumption cooling 174.94 kW
Electr. rated current consumption cooling 1146.35 A
Electr. rated power consumption heating 262.30 kW
Electr. rated current consumption heating 2121.5 kW
Electric. Nominal current consumption heating 2121.66 A
Electrical starting current, max. LRA316 A
Nominal volume flow, medium cooling42.69 m³/h
Nominal pressure loss, internal cooling51.1 kPa
Medium connections3”
Minimum medium volume system170 l
DimensionsHeight2270 mm
Width2205 mm
Depth4118 mm
Weight1848.3 kg
Operating weight approx.1886.4 kg
1 Air inlet 35°C, medium temperatures 7/12°C, 0% glycol
2 Air inlet 7°C, medium temperatures 35/30°C, 0% glycol
3 Distance 10 m free field
4 Air inlet 45°C, medium temperatures 15/18°C, 0% glycol
5 Only with compressor crankcase heater accessory
6 Only with winter pressure control accessory
7 Contains greenhouse gas according to Kyoto Protocol
Weather-resistant base frame with removable cladding panels made of powder-coated sheet steel, colour similar to RAL 9018. Condenser and sound-insulated compressor compartment separated from each other.
Air inlet horizontal via large-area high-performance condenser (cooling mode) in straight design made of refrigeration copper pipe with form-fit aluminium fins. Vertical air outlet via flow-optimised, statically and dynamically balanced axial fan(s) with protective cage. Standard operating limits in cooling mode between +45°C and +5°C, range extension with winter pressure control accessory down to -15°C 6 possible. Standard operating limits in heating mode between -10°C to +20°C.
Six fully hermetic, vibration-damped scroll compressors with refrigerating machine oil filling, optimally controlled according to the operating times.
Two refrigerant circuits made of refrigeration copper pipe, hermetically sealed and pressure-tested at the factory, dried and filled with safety refrigerant R 410A. Control option via Schrader valve. High and low pressure monitors, pressure transmitters on the high and low pressure side, filter dryer and thermostatic expansion valve with external pressure equalisation. Integrated four-way reversing valve for switching between cooling and heating mode. Evaporator as refrigerant/water heat exchanger in brazed plate design made of stainless steel, vapour diffusion-tight insulation, return temperature range from +18°C to +10°C in cooling mode and from +45°C to +30°C in heating mode.
Insulated medium circuit for water/glycol mixtures made of steel pipe with filling and draining connection, manual air vent valve and differential pressure switch for monitoring the volume flow. Medium connections in imperial Vitaulic design.
Control box with terminal strip for mains supply, potential-free input for external release, potential-free output for collective fault signal and connection of a cable remote control. Fully wired and tested main and control circuit with phase sequence relay, circuit breaker, fuses, contactors for main and control circuits and transformers fitted as standard. Automatic restart after power failure.
Easily accessible microprocessor controller with RS485 and USB interface for independent monitoring and control of all operating functions, protected from environmental influences and based on Linux. User-friendly display of all control parameters and coded fault messages within a value and parameter display, e.g. medium inlet and outlet temperatures, operating pressures in the refrigeration circuit. Function display of the operating modes, fan, compressors, circulation pump and collective fault.
Operation of the device using six operating buttons. Three password-protected parameter areas available.
Regional regulations, ordinances or environmental protection laws, e.g. WHG, must be taken into account when planning and installing the appliances.
Available as accessories:
Cable remote control, vibration damper, condenser protection grille, crankcase heater, winter pressure control, frost protection heating medium, heat recovery.
Technical unit transfer for optimum adjustment of the chiller on the system.
The units comply with the relevant EU regulations and are CE-marked in accordance with the applicable directives.
Technical performance data:
Type designationREMKO KWP 2105
Nominal cooling capacity, total 1200.42 kW
Nominal heating capacity 2248.22 kW
Energy efficiency parameter cooling EER 12.59
Energy efficiency parameter heating COP 23.83
Adjustment range, return temperature cooling+10 to +18 °C
Adjustment range, Return temperature, heating+30 to +45 °C
Cooling operating range 6-15 to +45 °C
Heating operating range +20 to +35°C
Capacity grading0/16/32/50/66/82/100
Refrigerant 7R 410A
Compressor, number / type6 / scroll
Fan, number4
Air flow rate, max. 85400 m³/h
Sound pressure level, max. 357.7 dB(A)
Sound power level85.7 dB(A)
Power supply400V/3~/50 Hz
Protection classIP 24
Electr. power consumption max. 491.46 kW
Electr. Current consumption max. 4189.99 A
Electr. rated power consumption cooling 174.94 kW
Electr. rated current consumption cooling 1146.35 A
Electr. rated power consumption heating 262.30 kW
Electr. rated current consumption heating 2121.5 kW
Electric. Nominal current consumption heating 2121.66 A
Electrical starting current, max. LRA316 A
Nominal volume flow, medium cooling42.69 m³/h
Nominal pressure loss, internal cooling51.1 kPa
Medium connections3”
Minimum medium volume system170 l
DimensionsHeight2270 mm
Width2205 mm
Depth4118 mm
Weight1848.3 kg
Operating weight approx.1886.4 kg
1 Air inlet 35°C, medium temperatures 7/12°C, 0% glycol
2 Air inlet 7°C, medium temperatures 35/30°C, 0% glycol
3 Distance 10 m free field
4 Air inlet 45°C, medium temperatures 15/18°C, 0% glycol
5 Only with compressor crankcase heater accessory
6 Only with winter pressure control accessory
7 Contains greenhouse gas according to Kyoto Protocol
Additional information
Product group:
4001
Depth:
4118mm
Width (mm):
2205.0MMT
Height (mm):
2270.0MMT
Length (mm):
4118.0MMT
Type:
STD
Related results
Complete catalogs
The offer is aimed exclusively at business customers, companies, public institutions, tradesmen and freelancers. All prices in catalogues are exclusive of VAT, shipping costs and surcharges if applicable.
The manufacturer is exclusively responsible for the content, price and article details of the products and offers presented in the catalogues. Subject to technical and optical changes by the manufacturer and errors excepted.
The manufacturer is exclusively responsible for the content, price and article details of the products and offers presented in the catalogues. Subject to technical and optical changes by the manufacturer and errors excepted.
Matching catalog
Commercial customer offer**
Product suggestions
Oil nozzle 2.25/60 degree S
1102823
€23.82
-14%
ATY 357 DC IT Deco
1624482
€407.06
-13%
Power board 954460 RVS
1106710
€128.53
Relay Board Merlin CMF/CMT-New version
1120030-N
€396.93
-19%
RK sound insulation hood SWK 5.1,
260939
€2,015.21
€2,480.00 MSRP
Condensate nozzle with plug MKT 240/250
1106882
€10.17
-4%
Support ring, 1-piece RK 25-50
1104168
€43.87
-19%
Cleaning part AS-RT-D, 180-D
1085058
€705.50
€867.98 MSRP
-10%
Reversing valve RXT 681 DC AT
1111598
€73.78
-4%
Side panel, left ATK 25
1103790
€45.50
Fan blade 200/31 DZH 20-2
1111663
€25.00
Silencer RK 70
1104117
€7.10
-4%
Insert (Vent. plug)
1108317
€33.95
-19%
RK WP Fresh water station
260180
€1,830.67
€2,252.98 MSRP
-4%
Pressure gauge 0-6 bar 1/4?
1108426
€59.16
No Review yet
Description: No Review yet
Written by: No Review
Rating: 5 out of 5
5 stars, based on 1
reviews
Remko Air conditioning cold water KWP 2105 1703415
REMKO GmbH & Co. KG 1703415
Remko 1703415
1703415
4026415135430
chilled water air conditioning systems
Chiller with heat pump function in compact design for outdoor installation, ready for connection, air-cooled.
Weather-resistant base frame with removable cladding panels made of powder-coated sheet steel, colour similar to RAL 9018. Condenser and sound-insulated compressor compartment separated from each other.
Air inlet horizontal via large-area high-performance condenser (cooling mode) in straight design made of refrigeration copper pipe with form-fit aluminium fins. Vertical air outlet via flow-optimised, statically and dynamically balanced axial fan(s) with protective cage. Standard operating limits in cooling mode between +45°C and +5°C, range extension with winter pressure control accessory down to -15°C 6 possible. Standard operating limits in heating mode between -10°C to +20°C.
Six fully hermetic, vibration-damped scroll compressors with refrigerating machine oil filling, optimally controlled according to the operating times.
Two refrigerant circuits made of refrigeration copper pipe, hermetically sealed and pressure-tested at the factory, dried and filled with safety refrigerant R 410A. Control option via Schrader valve. High and low pressure monitors, pressure transmitters on the high and low pressure side, filter dryer and thermostatic expansion valve with external pressure equalisation. Integrated four-way reversing valve for switching between cooling and heating mode. Evaporator as refrigerant/water heat exchanger in brazed plate design made of stainless steel, vapour diffusion-tight insulation, return temperature range from +18°C to +10°C in cooling mode and from +45°C to +30°C in heating mode.
Insulated medium circuit for water/glycol mixtures made of steel pipe with filling and draining connection, manual air vent valve and differential pressure switch for monitoring the volume flow. Medium connections in imperial Vitaulic design.
Control box with terminal strip for mains supply, potential-free input for external release, potential-free output for collective fault signal and connection of a cable remote control. Fully wired and tested main and control circuit with phase sequence relay, circuit breaker, fuses, contactors for main and control circuits and transformers fitted as standard. Automatic restart after power failure.
Easily accessible microprocessor controller with RS485 and USB interface for independent monitoring and control of all operating functions, protected from environmental influences and based on Linux. User-friendly display of all control parameters and coded fault messages within a value and parameter display, e.g. medium inlet and outlet temperatures, operating pressures in the refrigeration circuit. Function display of the operating modes, fan, compressors, circulation pump and collective fault.
Operation of the device using six operating buttons. Three password-protected parameter areas available.
Regional regulations, ordinances or environmental protection laws, e.g. WHG, must be taken into account when planning and installing the appliances.
Available as accessories:
Cable remote control, vibration damper, condenser protection grille, crankcase heater, winter pressure control, frost protection heating medium, heat recovery.
Technical unit transfer for optimum adjustment of the chiller on the system.
The units comply with the relevant EU regulations and are CE-marked in accordance with the applicable directives.
Technical performance data:
Type designationREMKO KWP 2105
Nominal cooling capacity, total 1200.42 kW
Nominal heating capacity 2248.22 kW
Energy efficiency parameter cooling EER 12.59
Energy efficiency parameter heating COP 23.83
Adjustment range, return temperature cooling+10 to +18 °C
Adjustment range, Return temperature, heating+30 to +45 °C
Cooling operating range 6-15 to +45 °C
Heating operating range +20 to +35°C
Capacity grading0/16/32/50/66/82/100
Refrigerant 7R 410A
Compressor, number / type6 / scroll
Fan, number4
Air flow rate, max. 85400 m³/h
Sound pressure level, max. 357.7 dB(A)
Sound power level85.7 dB(A)
Power supply400V/3~/50 Hz
Protection classIP 24
Electr. power consumption max. 491.46 kW
Electr. Current consumption max. 4189.99 A
Electr. rated power consumption cooling 174.94 kW
Electr. rated current consumption cooling 1146.35 A
Electr. rated power consumption heating 262.30 kW
Electr. rated current consumption heating 2121.5 kW
Electric. Nominal current consumption heating 2121.66 A
Electrical starting current, max. LRA316 A
Nominal volume flow, medium cooling42.69 m³/h
Nominal pressure loss, internal cooling51.1 kPa
Medium connections3”
Minimum medium volume system170 l
DimensionsHeight2270 mm
Width2205 mm
Depth4118 mm
Weight1848.3 kg
Operating weight approx.1886.4 kg
1 Air inlet 35°C, medium temperatures 7/12°C, 0% glycol
2 Air inlet 7°C, medium temperatures 35/30°C, 0% glycol
3 Distance 10 m free field
4 Air inlet 45°C, medium temperatures 15/18°C, 0% glycol
5 Only with compressor crankcase heater accessory
6 Only with winter pressure control accessory
7 Contains greenhouse gas according to Kyoto Protocol T-384882 1703415 4026415135430 en ["de","en","it","nl","nl","fr","es","pl","pt","cs","da","sv"] https://www.toolteam.com/en-GB/remko-air-conditioning-cold-water-kwp-2105-1703415-t-384882-4026415135430?dc=GB&cu=EUR 2026-07-14 61139.58 United Kingdom GB DE 14
Weather-resistant base frame with removable cladding panels made of powder-coated sheet steel, colour similar to RAL 9018. Condenser and sound-insulated compressor compartment separated from each other.
Air inlet horizontal via large-area high-performance condenser (cooling mode) in straight design made of refrigeration copper pipe with form-fit aluminium fins. Vertical air outlet via flow-optimised, statically and dynamically balanced axial fan(s) with protective cage. Standard operating limits in cooling mode between +45°C and +5°C, range extension with winter pressure control accessory down to -15°C 6 possible. Standard operating limits in heating mode between -10°C to +20°C.
Six fully hermetic, vibration-damped scroll compressors with refrigerating machine oil filling, optimally controlled according to the operating times.
Two refrigerant circuits made of refrigeration copper pipe, hermetically sealed and pressure-tested at the factory, dried and filled with safety refrigerant R 410A. Control option via Schrader valve. High and low pressure monitors, pressure transmitters on the high and low pressure side, filter dryer and thermostatic expansion valve with external pressure equalisation. Integrated four-way reversing valve for switching between cooling and heating mode. Evaporator as refrigerant/water heat exchanger in brazed plate design made of stainless steel, vapour diffusion-tight insulation, return temperature range from +18°C to +10°C in cooling mode and from +45°C to +30°C in heating mode.
Insulated medium circuit for water/glycol mixtures made of steel pipe with filling and draining connection, manual air vent valve and differential pressure switch for monitoring the volume flow. Medium connections in imperial Vitaulic design.
Control box with terminal strip for mains supply, potential-free input for external release, potential-free output for collective fault signal and connection of a cable remote control. Fully wired and tested main and control circuit with phase sequence relay, circuit breaker, fuses, contactors for main and control circuits and transformers fitted as standard. Automatic restart after power failure.
Easily accessible microprocessor controller with RS485 and USB interface for independent monitoring and control of all operating functions, protected from environmental influences and based on Linux. User-friendly display of all control parameters and coded fault messages within a value and parameter display, e.g. medium inlet and outlet temperatures, operating pressures in the refrigeration circuit. Function display of the operating modes, fan, compressors, circulation pump and collective fault.
Operation of the device using six operating buttons. Three password-protected parameter areas available.
Regional regulations, ordinances or environmental protection laws, e.g. WHG, must be taken into account when planning and installing the appliances.
Available as accessories:
Cable remote control, vibration damper, condenser protection grille, crankcase heater, winter pressure control, frost protection heating medium, heat recovery.
Technical unit transfer for optimum adjustment of the chiller on the system.
The units comply with the relevant EU regulations and are CE-marked in accordance with the applicable directives.
Technical performance data:
Type designationREMKO KWP 2105
Nominal cooling capacity, total 1200.42 kW
Nominal heating capacity 2248.22 kW
Energy efficiency parameter cooling EER 12.59
Energy efficiency parameter heating COP 23.83
Adjustment range, return temperature cooling+10 to +18 °C
Adjustment range, Return temperature, heating+30 to +45 °C
Cooling operating range 6-15 to +45 °C
Heating operating range +20 to +35°C
Capacity grading0/16/32/50/66/82/100
Refrigerant 7R 410A
Compressor, number / type6 / scroll
Fan, number4
Air flow rate, max. 85400 m³/h
Sound pressure level, max. 357.7 dB(A)
Sound power level85.7 dB(A)
Power supply400V/3~/50 Hz
Protection classIP 24
Electr. power consumption max. 491.46 kW
Electr. Current consumption max. 4189.99 A
Electr. rated power consumption cooling 174.94 kW
Electr. rated current consumption cooling 1146.35 A
Electr. rated power consumption heating 262.30 kW
Electr. rated current consumption heating 2121.5 kW
Electric. Nominal current consumption heating 2121.66 A
Electrical starting current, max. LRA316 A
Nominal volume flow, medium cooling42.69 m³/h
Nominal pressure loss, internal cooling51.1 kPa
Medium connections3”
Minimum medium volume system170 l
DimensionsHeight2270 mm
Width2205 mm
Depth4118 mm
Weight1848.3 kg
Operating weight approx.1886.4 kg
1 Air inlet 35°C, medium temperatures 7/12°C, 0% glycol
2 Air inlet 7°C, medium temperatures 35/30°C, 0% glycol
3 Distance 10 m free field
4 Air inlet 45°C, medium temperatures 15/18°C, 0% glycol
5 Only with compressor crankcase heater accessory
6 Only with winter pressure control accessory
7 Contains greenhouse gas according to Kyoto Protocol T-384882 1703415 4026415135430 en ["de","en","it","nl","nl","fr","es","pl","pt","cs","da","sv"] https://www.toolteam.com/en-GB/remko-air-conditioning-cold-water-kwp-2105-1703415-t-384882-4026415135430?dc=GB&cu=EUR 2026-07-14 61139.58 United Kingdom GB DE 14