Remko Air conditioning cold water KWP 1105 1703345
Sku: T-384868
Discontinued item
Product variants
| Sku: | Name: | SKU manufacturer: | ||
|---|---|---|---|---|
|
T-384865 | Air conditioning chilled water KWP 755 | 1703330 | |
|
T-384866 | Air conditioning chilled water KWP 855 | 1703335 | |
|
T-384867 | Air conditioning cold water KWP 955 | 1703340 | |
|
T-384869 | Air conditioning cold water KWP 1305 | 1703350 | |
|
T-384874 | Air conditioning cold water KWP 605 SLN | 1703375 | |
|
T-384875 | Air conditioning cold water KWP 755 SLN | 1703380 | |
|
T-384876 | Air conditioning chilled water KWP 855 SLN | 1703385 | |
|
T-384877 | Air conditioning cold water KWP 955 SLN | 1703390 | |
|
T-384878 | Air conditioning cold water KWP 1105 SLN | 1703395 |
doneProduct group: 4001
doneDepth: 3005mm
doneDepth: 3005mm
doneType: STD
Remko Klima cold water KWP 1105 1703345
Product data
Manufacturer:
REMKO GmbH & Co. KG
Condition:
NEW
Sku:
T-384868
SKU manufacturer:
1703345
GTIN Code (EAN):
4026415135133
Weight:
882,40 Kg
All information relating to products from REMKO GmbH & Co. KG. Technical and optical modifications of the manufacturer and errors reserved.
This page has been machine-translated, the original german version can be found here, please also note the Translation Disclaimer.
Product description
Chilled water generator with heat pump function in compact design for outdoor installation, ready for connection, air-cooled.
Weather-resistant base frame with removable cladding panels made of powder-coated sheet steel, colour similar to RAL 9018. Condenser and sound-insulated compressor compartment separated from each other.
Air inlet horizontal via large-area high-performance condenser (cooling mode) in straight design made of refrigeration copper pipe with form-fit aluminium fins. Vertical air outlet via aerodynamically optimised, statically and dynamically balanced axial fan(s) with protective cage. Standard operating limits in cooling mode between +45°C and +5°C, range can be extended down to -15°C 6) with winter pressure control accessory. Standard operating limits in heating mode between -10°C to +20°C.Three fully hermetic, vibration-damped scroll compressors with refrigeration oil filling, optimally controlled according to the operating times.One refrigerant circuit made of refrigeration copper pipe, hermetically sealed and pressure-tested at the factory, dried and filled with R 410 A safety refrigerant. Control option via Schrader valve. High and low pressure monitors, pressure transmitters on the high and low pressure side, filter dryer and thermostatic expansion valve with external pressure equalisation. Integrated four-way reversing valve for switching between cooling and heating mode. Evaporator as refrigerant/water heat exchanger in brazed plate design made of stainless steel, vapour diffusion-tight insulation, return temperature range from +18°C to +10°C in cooling mode and from +45°C to +20°C in heating mode.Insulated medium circuit for water/glycol mixtures made of steel pipe with filling and draining connection, manual air vent valve and differential pressure switch for monitoring the volume flow. Medium connections in imperial Vitaulic design.
Control box with terminal strip for mains supply, potential-free input for external release, potential-free output for collective fault signal and connection of a cable remote control. Fully wired and tested main and control circuit with phase sequence relay, circuit breaker, fuses, contactors for main and control circuits and transformers fitted as standard. Automatic restart after power failure.
Easily accessible microprocessor controller with RS485 and USB interface for independent monitoring and control of all operating functions, protected from environmental influences and based on Linux. User-friendly display of all control parameters and coded fault messages within a value and parameter display, e.g. medium inlet and outlet temperatures, operating pressures in the refrigeration circuit. Function display of the operating modes, fan, compressors, circulation pump and collective fault, operation of the device using six operating buttons. Three password-protected parameter areas available.
Regional regulations and ordinances or environmental protection laws, e.g. WHG, must be taken into account when planning and installing the appliances.
Accessories available:
Cable remote control, vibration damper, condenser protection grille, crankcase heater, winter pressure control, medium frost protection heater, heat recovery. Technical unit transfer for optimum adjustment of the chiller on the system.
The units comply with the relevant EU regulations and are CE-marked in accordance with the applicable directives.
Technical performance data:
MakeREMKO
TypeKWP 1105
Nominal cooling capacity, total 1) [kW]110.40
Nominal heating capacity 2) [kW]132.80
Energy efficiency parameter cooling EER 1)2.57
Energy efficiency parameter heating COP 2)3.92
Setting range, return temperature cooling [°C]+10 to +18
Setting range, Return temperature, heating [°C]+30 to +45
Working range, cooling 6)/heating [°C]-15 to +45/-10 to +20
Capacity grading0/33/66/100
Refrigerant 7)R 410 A
Compressor, number/type3/scroll
Fan, number2
Air flow rate, max. [m³/h]42000
Sound pressure level, max. 3) [dB(A)]54.0
Sound power level [dB(A)]86.0
Voltage supply [V/~/Hz]400/3/50
Protection classIP 24
Electrical power consumption max. 4) [kW]65.47
Electrical current consumption max. 4) [A]94.59
Electr. rated power consumption cooling 1) [kW]42.93
Electr. rated current consumption cooling 1) [A]65.30
Electr. rated power consumption heating 2) [kW]33.92
Electr. rated current consumption heating 2) [A]51.06
Electr. starting current, max. LRA [A]201.20
Nominal volume flow, medium cooling [m³/h]19.01
Nominal pressure losses, internal cooling [kPa]22.9
Medium connections2 ‘
Minimum medium volume system [l]360.0
Dimensions (H/W/D) [mm]1954/1123/3005
Weight [kg]882.4
Operating weight approx. [kg]891.8
1) Air inlet 35°C, medium temperatures 7/12°C, 0% glycol
2) Air inlet 7°C, medium temperatures 35/30°C, 0% glycol
3) Distance 10 m free field
4) Air inlet 45°C, medium temperatures 18/15°C, 0% glycol
5) Only with compressor crankcase heater accessory
6) Only with winter pressure control accessory
7) Contains greenhouse gas in accordance with the Kyoto Protocol
Weather-resistant base frame with removable cladding panels made of powder-coated sheet steel, colour similar to RAL 9018. Condenser and sound-insulated compressor compartment separated from each other.
Air inlet horizontal via large-area high-performance condenser (cooling mode) in straight design made of refrigeration copper pipe with form-fit aluminium fins. Vertical air outlet via aerodynamically optimised, statically and dynamically balanced axial fan(s) with protective cage. Standard operating limits in cooling mode between +45°C and +5°C, range can be extended down to -15°C 6) with winter pressure control accessory. Standard operating limits in heating mode between -10°C to +20°C.Three fully hermetic, vibration-damped scroll compressors with refrigeration oil filling, optimally controlled according to the operating times.One refrigerant circuit made of refrigeration copper pipe, hermetically sealed and pressure-tested at the factory, dried and filled with R 410 A safety refrigerant. Control option via Schrader valve. High and low pressure monitors, pressure transmitters on the high and low pressure side, filter dryer and thermostatic expansion valve with external pressure equalisation. Integrated four-way reversing valve for switching between cooling and heating mode. Evaporator as refrigerant/water heat exchanger in brazed plate design made of stainless steel, vapour diffusion-tight insulation, return temperature range from +18°C to +10°C in cooling mode and from +45°C to +20°C in heating mode.Insulated medium circuit for water/glycol mixtures made of steel pipe with filling and draining connection, manual air vent valve and differential pressure switch for monitoring the volume flow. Medium connections in imperial Vitaulic design.
Control box with terminal strip for mains supply, potential-free input for external release, potential-free output for collective fault signal and connection of a cable remote control. Fully wired and tested main and control circuit with phase sequence relay, circuit breaker, fuses, contactors for main and control circuits and transformers fitted as standard. Automatic restart after power failure.
Easily accessible microprocessor controller with RS485 and USB interface for independent monitoring and control of all operating functions, protected from environmental influences and based on Linux. User-friendly display of all control parameters and coded fault messages within a value and parameter display, e.g. medium inlet and outlet temperatures, operating pressures in the refrigeration circuit. Function display of the operating modes, fan, compressors, circulation pump and collective fault, operation of the device using six operating buttons. Three password-protected parameter areas available.
Regional regulations and ordinances or environmental protection laws, e.g. WHG, must be taken into account when planning and installing the appliances.
Accessories available:
Cable remote control, vibration damper, condenser protection grille, crankcase heater, winter pressure control, medium frost protection heater, heat recovery. Technical unit transfer for optimum adjustment of the chiller on the system.
The units comply with the relevant EU regulations and are CE-marked in accordance with the applicable directives.
Technical performance data:
MakeREMKO
TypeKWP 1105
Nominal cooling capacity, total 1) [kW]110.40
Nominal heating capacity 2) [kW]132.80
Energy efficiency parameter cooling EER 1)2.57
Energy efficiency parameter heating COP 2)3.92
Setting range, return temperature cooling [°C]+10 to +18
Setting range, Return temperature, heating [°C]+30 to +45
Working range, cooling 6)/heating [°C]-15 to +45/-10 to +20
Capacity grading0/33/66/100
Refrigerant 7)R 410 A
Compressor, number/type3/scroll
Fan, number2
Air flow rate, max. [m³/h]42000
Sound pressure level, max. 3) [dB(A)]54.0
Sound power level [dB(A)]86.0
Voltage supply [V/~/Hz]400/3/50
Protection classIP 24
Electrical power consumption max. 4) [kW]65.47
Electrical current consumption max. 4) [A]94.59
Electr. rated power consumption cooling 1) [kW]42.93
Electr. rated current consumption cooling 1) [A]65.30
Electr. rated power consumption heating 2) [kW]33.92
Electr. rated current consumption heating 2) [A]51.06
Electr. starting current, max. LRA [A]201.20
Nominal volume flow, medium cooling [m³/h]19.01
Nominal pressure losses, internal cooling [kPa]22.9
Medium connections2 ‘
Minimum medium volume system [l]360.0
Dimensions (H/W/D) [mm]1954/1123/3005
Weight [kg]882.4
Operating weight approx. [kg]891.8
1) Air inlet 35°C, medium temperatures 7/12°C, 0% glycol
2) Air inlet 7°C, medium temperatures 35/30°C, 0% glycol
3) Distance 10 m free field
4) Air inlet 45°C, medium temperatures 18/15°C, 0% glycol
5) Only with compressor crankcase heater accessory
6) Only with winter pressure control accessory
7) Contains greenhouse gas in accordance with the Kyoto Protocol
Additional information
Product group:
4001
Depth:
3005mm
Width (mm):
1123.0MMT
Height (mm):
1945.0MMT
Length (mm):
3005.0MMT
Type:
STD
Related results
Complete catalogs
The offer is aimed exclusively at business customers, companies, public institutions, tradesmen and freelancers. All prices in catalogues are exclusive of VAT, shipping costs and surcharges if applicable.
The manufacturer is exclusively responsible for the content, price and article details of the products and offers presented in the catalogues. Subject to technical and optical changes by the manufacturer and errors excepted.
The manufacturer is exclusively responsible for the content, price and article details of the products and offers presented in the catalogues. Subject to technical and optical changes by the manufacturer and errors excepted.
Matching catalog
Commercial customer offer**
Product suggestions
-4%
Housing front BL 353 DC IT/SKW 350 DC IT
1113452
€63.32
-10%
Device cover SKW 520 IT
1113560
€62.51
-13%
Condensate drip tray KWK 450/600 (ZW)
1111783
€169.33
-10%
Reversing valve RXT 681 DC AT
1111598
€73.78
-13%
Pressure regulator 1.5 bar/10 kg
1101663
€186.60
-10%
Base plate AMT 65/85-E
1105957
€118.53
-14%
Relay board WP-Manager (WMZ version) CMT 120/160
1120194
€297.69
-13%
Oil pump AD1L2 Replacement for V1-LR2 1/4?
1108640
€159.20
-13%
Outer sheath PGT 100
1101681
€227.48
-10%
Condenser board RXT 1401 DC
1111958
€76.39
-14%
ATY 527 DC IT Deco
1624492
€531.30
Accessory pack 1
1106445
€21.67
-13%
Oil pump VM 1
1108498
€189.03
-13%
Power board 954460 RVS
1106710
€128.53
-14%
Control board RVT 681 DC AT
1109849
€453.07
No Review yet
Description: No Review yet
Written by: No Review
Rating: 5 out of 5
5 stars, based on 1
reviews
Remko Air conditioning cold water KWP 1105 1703345
REMKO GmbH & Co. KG 1703345
Remko 1703345
1703345
4026415135133
chilled water air conditioning systems
Chilled water generator with heat pump function in compact design for outdoor installation, ready for connection, air-cooled.
Weather-resistant base frame with removable cladding panels made of powder-coated sheet steel, colour similar to RAL 9018. Condenser and sound-insulated compressor compartment separated from each other.
Air inlet horizontal via large-area high-performance condenser (cooling mode) in straight design made of refrigeration copper pipe with form-fit aluminium fins. Vertical air outlet via aerodynamically optimised, statically and dynamically balanced axial fan(s) with protective cage. Standard operating limits in cooling mode between +45°C and +5°C, range can be extended down to -15°C 6) with winter pressure control accessory. Standard operating limits in heating mode between -10°C to +20°C.Three fully hermetic, vibration-damped scroll compressors with refrigeration oil filling, optimally controlled according to the operating times.One refrigerant circuit made of refrigeration copper pipe, hermetically sealed and pressure-tested at the factory, dried and filled with R 410 A safety refrigerant. Control option via Schrader valve. High and low pressure monitors, pressure transmitters on the high and low pressure side, filter dryer and thermostatic expansion valve with external pressure equalisation. Integrated four-way reversing valve for switching between cooling and heating mode. Evaporator as refrigerant/water heat exchanger in brazed plate design made of stainless steel, vapour diffusion-tight insulation, return temperature range from +18°C to +10°C in cooling mode and from +45°C to +20°C in heating mode.Insulated medium circuit for water/glycol mixtures made of steel pipe with filling and draining connection, manual air vent valve and differential pressure switch for monitoring the volume flow. Medium connections in imperial Vitaulic design.
Control box with terminal strip for mains supply, potential-free input for external release, potential-free output for collective fault signal and connection of a cable remote control. Fully wired and tested main and control circuit with phase sequence relay, circuit breaker, fuses, contactors for main and control circuits and transformers fitted as standard. Automatic restart after power failure.
Easily accessible microprocessor controller with RS485 and USB interface for independent monitoring and control of all operating functions, protected from environmental influences and based on Linux. User-friendly display of all control parameters and coded fault messages within a value and parameter display, e.g. medium inlet and outlet temperatures, operating pressures in the refrigeration circuit. Function display of the operating modes, fan, compressors, circulation pump and collective fault, operation of the device using six operating buttons. Three password-protected parameter areas available.
Regional regulations and ordinances or environmental protection laws, e.g. WHG, must be taken into account when planning and installing the appliances.
Accessories available:
Cable remote control, vibration damper, condenser protection grille, crankcase heater, winter pressure control, medium frost protection heater, heat recovery. Technical unit transfer for optimum adjustment of the chiller on the system.
The units comply with the relevant EU regulations and are CE-marked in accordance with the applicable directives.
Technical performance data:
MakeREMKO
TypeKWP 1105
Nominal cooling capacity, total 1) [kW]110.40
Nominal heating capacity 2) [kW]132.80
Energy efficiency parameter cooling EER 1)2.57
Energy efficiency parameter heating COP 2)3.92
Setting range, return temperature cooling [°C]+10 to +18
Setting range, Return temperature, heating [°C]+30 to +45
Working range, cooling 6)/heating [°C]-15 to +45/-10 to +20
Capacity grading0/33/66/100
Refrigerant 7)R 410 A
Compressor, number/type3/scroll
Fan, number2
Air flow rate, max. [m³/h]42000
Sound pressure level, max. 3) [dB(A)]54.0
Sound power level [dB(A)]86.0
Voltage supply [V/~/Hz]400/3/50
Protection classIP 24
Electrical power consumption max. 4) [kW]65.47
Electrical current consumption max. 4) [A]94.59
Electr. rated power consumption cooling 1) [kW]42.93
Electr. rated current consumption cooling 1) [A]65.30
Electr. rated power consumption heating 2) [kW]33.92
Electr. rated current consumption heating 2) [A]51.06
Electr. starting current, max. LRA [A]201.20
Nominal volume flow, medium cooling [m³/h]19.01
Nominal pressure losses, internal cooling [kPa]22.9
Medium connections2 ‘
Minimum medium volume system [l]360.0
Dimensions (H/W/D) [mm]1954/1123/3005
Weight [kg]882.4
Operating weight approx. [kg]891.8
1) Air inlet 35°C, medium temperatures 7/12°C, 0% glycol
2) Air inlet 7°C, medium temperatures 35/30°C, 0% glycol
3) Distance 10 m free field
4) Air inlet 45°C, medium temperatures 18/15°C, 0% glycol
5) Only with compressor crankcase heater accessory
6) Only with winter pressure control accessory
7) Contains greenhouse gas in accordance with the Kyoto Protocol T-384868 1703345 4026415135133 en ["de","en","it","nl","nl","fr","es","pl","pt","cs","da","sv"] https://www.toolteam.com/en-GB/remko-air-conditioning-cold-water-kwp-1105-1703345-t-384868-4026415135133?dc=GB&cu=EUR 2026-07-09 35220.25 United Kingdom GB DE 14
Weather-resistant base frame with removable cladding panels made of powder-coated sheet steel, colour similar to RAL 9018. Condenser and sound-insulated compressor compartment separated from each other.
Air inlet horizontal via large-area high-performance condenser (cooling mode) in straight design made of refrigeration copper pipe with form-fit aluminium fins. Vertical air outlet via aerodynamically optimised, statically and dynamically balanced axial fan(s) with protective cage. Standard operating limits in cooling mode between +45°C and +5°C, range can be extended down to -15°C 6) with winter pressure control accessory. Standard operating limits in heating mode between -10°C to +20°C.Three fully hermetic, vibration-damped scroll compressors with refrigeration oil filling, optimally controlled according to the operating times.One refrigerant circuit made of refrigeration copper pipe, hermetically sealed and pressure-tested at the factory, dried and filled with R 410 A safety refrigerant. Control option via Schrader valve. High and low pressure monitors, pressure transmitters on the high and low pressure side, filter dryer and thermostatic expansion valve with external pressure equalisation. Integrated four-way reversing valve for switching between cooling and heating mode. Evaporator as refrigerant/water heat exchanger in brazed plate design made of stainless steel, vapour diffusion-tight insulation, return temperature range from +18°C to +10°C in cooling mode and from +45°C to +20°C in heating mode.Insulated medium circuit for water/glycol mixtures made of steel pipe with filling and draining connection, manual air vent valve and differential pressure switch for monitoring the volume flow. Medium connections in imperial Vitaulic design.
Control box with terminal strip for mains supply, potential-free input for external release, potential-free output for collective fault signal and connection of a cable remote control. Fully wired and tested main and control circuit with phase sequence relay, circuit breaker, fuses, contactors for main and control circuits and transformers fitted as standard. Automatic restart after power failure.
Easily accessible microprocessor controller with RS485 and USB interface for independent monitoring and control of all operating functions, protected from environmental influences and based on Linux. User-friendly display of all control parameters and coded fault messages within a value and parameter display, e.g. medium inlet and outlet temperatures, operating pressures in the refrigeration circuit. Function display of the operating modes, fan, compressors, circulation pump and collective fault, operation of the device using six operating buttons. Three password-protected parameter areas available.
Regional regulations and ordinances or environmental protection laws, e.g. WHG, must be taken into account when planning and installing the appliances.
Accessories available:
Cable remote control, vibration damper, condenser protection grille, crankcase heater, winter pressure control, medium frost protection heater, heat recovery. Technical unit transfer for optimum adjustment of the chiller on the system.
The units comply with the relevant EU regulations and are CE-marked in accordance with the applicable directives.
Technical performance data:
MakeREMKO
TypeKWP 1105
Nominal cooling capacity, total 1) [kW]110.40
Nominal heating capacity 2) [kW]132.80
Energy efficiency parameter cooling EER 1)2.57
Energy efficiency parameter heating COP 2)3.92
Setting range, return temperature cooling [°C]+10 to +18
Setting range, Return temperature, heating [°C]+30 to +45
Working range, cooling 6)/heating [°C]-15 to +45/-10 to +20
Capacity grading0/33/66/100
Refrigerant 7)R 410 A
Compressor, number/type3/scroll
Fan, number2
Air flow rate, max. [m³/h]42000
Sound pressure level, max. 3) [dB(A)]54.0
Sound power level [dB(A)]86.0
Voltage supply [V/~/Hz]400/3/50
Protection classIP 24
Electrical power consumption max. 4) [kW]65.47
Electrical current consumption max. 4) [A]94.59
Electr. rated power consumption cooling 1) [kW]42.93
Electr. rated current consumption cooling 1) [A]65.30
Electr. rated power consumption heating 2) [kW]33.92
Electr. rated current consumption heating 2) [A]51.06
Electr. starting current, max. LRA [A]201.20
Nominal volume flow, medium cooling [m³/h]19.01
Nominal pressure losses, internal cooling [kPa]22.9
Medium connections2 ‘
Minimum medium volume system [l]360.0
Dimensions (H/W/D) [mm]1954/1123/3005
Weight [kg]882.4
Operating weight approx. [kg]891.8
1) Air inlet 35°C, medium temperatures 7/12°C, 0% glycol
2) Air inlet 7°C, medium temperatures 35/30°C, 0% glycol
3) Distance 10 m free field
4) Air inlet 45°C, medium temperatures 18/15°C, 0% glycol
5) Only with compressor crankcase heater accessory
6) Only with winter pressure control accessory
7) Contains greenhouse gas in accordance with the Kyoto Protocol T-384868 1703345 4026415135133 en ["de","en","it","nl","nl","fr","es","pl","pt","cs","da","sv"] https://www.toolteam.com/en-GB/remko-air-conditioning-cold-water-kwp-1105-1703345-t-384868-4026415135133?dc=GB&cu=EUR 2026-07-09 35220.25 United Kingdom GB DE 14