zoom_in
zoom_out
fullscreen
Remko Air conditioning cold water KWK 680 ZW 1662305
Sku: T-384526
Discontinued item
Product variants
| Sku: | Name: | SKU manufacturer: | ||
|---|---|---|---|---|
|
T-384508 | Air conditioning cold water KWK 130 ZW | 1662215 | |
|
T-384510 | Air conditioning cold water CHP 140 ZW | 1662225 | |
|
T-384512 | Air conditioning cold water KWK 200 ZW | 1662235 | |
|
T-384514 | Air conditioning cold water KWK 220 ZW | 1662245 | |
|
T-384516 | Air conditioning cold water KWK 280 ZW | 1662255 | |
|
T-384518 | Air conditioning cold water CHP 300 ZW | 1662265 | |
|
T-384520 | Air conditioning cold water KWK 360 ZW | 1662275 | |
|
T-384522 | Air conditioning cold water KWK 420 ZW | 1662285 | |
|
T-384524 | Air conditioning cold water KWK 590 ZW | 1662295 | |
|
T-384528 | Air conditioning cold water KWK 740 ZW | 1662315 | |
|
T-384530 | Air conditioning cold water KWK 870 ZW | 1662325 | |
|
T-384535 | Air conditioning chilled water KWK 140 EC ZW | 1662505 | |
|
T-384537 | Air conditioning chilled water KWK 220 EC ZW | 1662515 | |
|
T-384539 | Air conditioning cold water KWK 300 EC ZW | 1662525 | |
|
T-384541 | Air conditioning cold water KWK 500 EC ZW | 1662535 | |
|
T-384543 | Air conditioning chilled water KWK 690 EC ZW | 1662545 | |
|
T-384545 | Air conditioning cold water KWK 830 EC ZW | 1662555 |
doneProduct group: 4001
doneType: STD
doneType: STD
Remko Klima cold water KWK 680 ZW 1662305
Product data
Manufacturer:
REMKO GmbH & Co. KG
Condition:
NEW
Sku:
T-384526
SKU manufacturer:
1662305
GTIN Code (EAN):
4026415120009
Weight:
32,00 Kg
All information relating to products from REMKO GmbH & Co. KG. Technical and optical modifications of the manufacturer and errors reserved.
This page has been machine-translated, the original german version can be found here, please also note the Translation Disclaimer.
Product description
Chilled water chest unit for installation in intermediate spaces for wall or ceiling mounting without cover in a two-pipe system.
Casing made of dimensionally stable sheet steel, fully insulated.
Integrated, low-noise centrifugal fan with three-speed adjustable, thermally protected drive motor, statically and dynamically balanced.
Air inlet from the rear (horizontal) or bottom (vertical) with large-surface
Air outlet at the front (horizontal) or top (vertical) via a free air outlet opening to accommodate a connection duct.
Air cooler or air heater as heat exchanger in Cu/Al design made of seamlessly drawn copper pipe with form-fit aluminium fins for cold or hot water or water/glycol mixture up to max. 80°C. Tightness tested at the factory. Brass pipe connections in imperial design with bleed and drain valves provided on the left-hand side of the appliance at the factory. Depending on the installation variant, the coil connection side and the condensate connection can be exchanged.
Insulated condensate tray made of sheet steel for vertical installation and another condensate tray made of sheet steel for horizontal installation. Condensate connection on the side of the appliance.
Electrical connection terminals on the side of the appliance.
The medium flow rate can be regulated using an optional 3-way valve assembly on the appliance. The appliance can be extended for a four-pipe system by installing an additional heating coil.
Available as accessories:
Condensate pump, room temperature control for surface mounting, switching relay for 4 devices, heating coil for four-pipe system, valve assembly two-pipe system, valve assembly four-pipe system, duct angle 90° air inlet, duct angle 90° air outlet, grille in aluminium, for air inlet, grille in aluminium for air outlet, electrical heating resistor, fault signal module
The devices comply with the relevant EU regulations and are CE-marked in accordance with the applicable directives.
Technical performance data:
MakeREMKO
TypeKWK 680 ZW
Nominal cooling capacity, total 1) [kW]6.8
Nominal cooling capacity, sensitive 1) [kW]5.36
Nominal heating capacity 2) [kW]7.54
Application area (room volume), approx. [m³]220
Working range, indoor unit [°C]+15 to +35
Air volume flow, per stage [m³/h]538/843/1203
Sound pressure level, per stage 3) [dB(A)]32/43/51
Voltage supply [V/~/Hz]230/1/50
Protection classIP X0
Electr. Rated power consumption cooling 1) [W]145
Rated electrical current consumption cooling 1) [A]0.69
Operating medium max. 35% ethylene/propylene glycol
Operating pressure, max. medium [kPa Medium [kPa]600
Nominal volume flow, medium cooling 1) [m³/h]1.17
Nominal volume flow, medium heating 2) [m³/h]1.3
Nominal pressure losses, internal cooling 1) [kPa]18
Nominal pressure losses, internal heating 2) [kPa]33, 5
Medium connections1/2”
Medium capacity [l]2.4
Condensate connection [mm]19
Dimensions (H/W/D) [mm]226/1210/493
Weight [kg]25.0
1) Air inlet TK 27°C / FK 19°C, medium temperatures 7/12 °C, 0% glycol concentration, max. air volume flow rate
2) Air inlet 20°C, medium temperatures 45/40 °C, 0% glycol concentration, max. air volume flow rate
3) Distance 1.0 m in a 100m² room with a reverberation time of 0.3s
Casing made of dimensionally stable sheet steel, fully insulated.
Integrated, low-noise centrifugal fan with three-speed adjustable, thermally protected drive motor, statically and dynamically balanced.
Air inlet from the rear (horizontal) or bottom (vertical) with large-surface
Air outlet at the front (horizontal) or top (vertical) via a free air outlet opening to accommodate a connection duct.
Air cooler or air heater as heat exchanger in Cu/Al design made of seamlessly drawn copper pipe with form-fit aluminium fins for cold or hot water or water/glycol mixture up to max. 80°C. Tightness tested at the factory. Brass pipe connections in imperial design with bleed and drain valves provided on the left-hand side of the appliance at the factory. Depending on the installation variant, the coil connection side and the condensate connection can be exchanged.
Insulated condensate tray made of sheet steel for vertical installation and another condensate tray made of sheet steel for horizontal installation. Condensate connection on the side of the appliance.
Electrical connection terminals on the side of the appliance.
The medium flow rate can be regulated using an optional 3-way valve assembly on the appliance. The appliance can be extended for a four-pipe system by installing an additional heating coil.
Available as accessories:
Condensate pump, room temperature control for surface mounting, switching relay for 4 devices, heating coil for four-pipe system, valve assembly two-pipe system, valve assembly four-pipe system, duct angle 90° air inlet, duct angle 90° air outlet, grille in aluminium, for air inlet, grille in aluminium for air outlet, electrical heating resistor, fault signal module
The devices comply with the relevant EU regulations and are CE-marked in accordance with the applicable directives.
Technical performance data:
MakeREMKO
TypeKWK 680 ZW
Nominal cooling capacity, total 1) [kW]6.8
Nominal cooling capacity, sensitive 1) [kW]5.36
Nominal heating capacity 2) [kW]7.54
Application area (room volume), approx. [m³]220
Working range, indoor unit [°C]+15 to +35
Air volume flow, per stage [m³/h]538/843/1203
Sound pressure level, per stage 3) [dB(A)]32/43/51
Voltage supply [V/~/Hz]230/1/50
Protection classIP X0
Electr. Rated power consumption cooling 1) [W]145
Rated electrical current consumption cooling 1) [A]0.69
Operating medium max. 35% ethylene/propylene glycol
Operating pressure, max. medium [kPa Medium [kPa]600
Nominal volume flow, medium cooling 1) [m³/h]1.17
Nominal volume flow, medium heating 2) [m³/h]1.3
Nominal pressure losses, internal cooling 1) [kPa]18
Nominal pressure losses, internal heating 2) [kPa]33, 5
Medium connections1/2”
Medium capacity [l]2.4
Condensate connection [mm]19
Dimensions (H/W/D) [mm]226/1210/493
Weight [kg]25.0
1) Air inlet TK 27°C / FK 19°C, medium temperatures 7/12 °C, 0% glycol concentration, max. air volume flow rate
2) Air inlet 20°C, medium temperatures 45/40 °C, 0% glycol concentration, max. air volume flow rate
3) Distance 1.0 m in a 100m² room with a reverberation time of 0.3s
Additional information
Product group:
4001
Width (mm):
1210.0MMT
Height (mm):
226.0MMT
Length (mm):
493.0MMT
Type:
STD
Related results
Complete catalogs
The offer is aimed exclusively at business customers, companies, public institutions, tradesmen and freelancers. All prices in catalogues are exclusive of VAT, shipping costs and surcharges if applicable.
The manufacturer is exclusively responsible for the content, price and article details of the products and offers presented in the catalogues. Subject to technical and optical changes by the manufacturer and errors excepted.
The manufacturer is exclusively responsible for the content, price and article details of the products and offers presented in the catalogues. Subject to technical and optical changes by the manufacturer and errors excepted.
Matching catalog
Commercial customer offer**
Product suggestions
-19%
RK WP Fresh water station
260180
€1,830.67
€2,252.98 MSRP
-14%
ATY 267 Deco
1623430
€445.62
-10%
Condenser board RXT 1401 DC
1111958
€76.39
-10%
Device cover SKW 520 IT
1113560
€62.51
Oil nozzle 1.75/80 size S DZH 90
1107372
€25.00
Relay Board Merlin CMF/CMT-New version
1120030-N
€396.93
-13%
Oil pump VM 1
1108498
€189.03
-19%
RK sound insulation hood SWK 4.1,
260938
€1,917.69
€2,360.00 MSRP
-4%
Quick coupling suction line BL 263/353 DC AT
1113540
€53.49
Mounting plate shut-off valve RVT 263 DC AT
1112422
€15.25
-13%
Condensate drip tray KWK 450/600 (ZW)
1111783
€169.33
-13%
Outer sheath PGT 100
1101681
€227.48
Accessory pack 1
1106445
€21.67
-14%
Heating circuit pump HGU/HGM Wilo Stratos PARA 25/1-7 T1
1120909
€372.61
RK Netzstecker
1123916
€12.82
No Review yet
Description: No Review yet
Written by: No Review
Rating: 5 out of 5
5 stars, based on 1
reviews
Remko Air conditioning cold water KWK 680 ZW 1662305
REMKO GmbH & Co. KG 1662305
Remko 1662305
1662305
4026415120009
chilled water air conditioning systems
Chilled water chest unit for installation in intermediate spaces for wall or ceiling mounting without cover in a two-pipe system.
Casing made of dimensionally stable sheet steel, fully insulated.
Integrated, low-noise centrifugal fan with three-speed adjustable, thermally protected drive motor, statically and dynamically balanced.
Air inlet from the rear (horizontal) or bottom (vertical) with large-surface
Air outlet at the front (horizontal) or top (vertical) via a free air outlet opening to accommodate a connection duct.
Air cooler or air heater as heat exchanger in Cu/Al design made of seamlessly drawn copper pipe with form-fit aluminium fins for cold or hot water or water/glycol mixture up to max. 80°C. Tightness tested at the factory. Brass pipe connections in imperial design with bleed and drain valves provided on the left-hand side of the appliance at the factory. Depending on the installation variant, the coil connection side and the condensate connection can be exchanged.
Insulated condensate tray made of sheet steel for vertical installation and another condensate tray made of sheet steel for horizontal installation. Condensate connection on the side of the appliance.
Electrical connection terminals on the side of the appliance.
The medium flow rate can be regulated using an optional 3-way valve assembly on the appliance. The appliance can be extended for a four-pipe system by installing an additional heating coil.
Available as accessories:
Condensate pump, room temperature control for surface mounting, switching relay for 4 devices, heating coil for four-pipe system, valve assembly two-pipe system, valve assembly four-pipe system, duct angle 90° air inlet, duct angle 90° air outlet, grille in aluminium, for air inlet, grille in aluminium for air outlet, electrical heating resistor, fault signal module
The devices comply with the relevant EU regulations and are CE-marked in accordance with the applicable directives.
Technical performance data:
MakeREMKO
TypeKWK 680 ZW
Nominal cooling capacity, total 1) [kW]6.8
Nominal cooling capacity, sensitive 1) [kW]5.36
Nominal heating capacity 2) [kW]7.54
Application area (room volume), approx. [m³]220
Working range, indoor unit [°C]+15 to +35
Air volume flow, per stage [m³/h]538/843/1203
Sound pressure level, per stage 3) [dB(A)]32/43/51
Voltage supply [V/~/Hz]230/1/50
Protection classIP X0
Electr. Rated power consumption cooling 1) [W]145
Rated electrical current consumption cooling 1) [A]0.69
Operating medium max. 35% ethylene/propylene glycol
Operating pressure, max. medium [kPa Medium [kPa]600
Nominal volume flow, medium cooling 1) [m³/h]1.17
Nominal volume flow, medium heating 2) [m³/h]1.3
Nominal pressure losses, internal cooling 1) [kPa]18
Nominal pressure losses, internal heating 2) [kPa]33, 5
Medium connections1/2”
Medium capacity [l]2.4
Condensate connection [mm]19
Dimensions (H/W/D) [mm]226/1210/493
Weight [kg]25.0
1) Air inlet TK 27°C / FK 19°C, medium temperatures 7/12 °C, 0% glycol concentration, max. air volume flow rate
2) Air inlet 20°C, medium temperatures 45/40 °C, 0% glycol concentration, max. air volume flow rate
3) Distance 1.0 m in a 100m² room with a reverberation time of 0.3s T-384526 1662305 4026415120009 en ["de","en","it","nl","nl","fr","es","pl","pt","cs","da","sv"] https://www.toolteam.com/en-GB/remko-air-conditioning-cold-water-kwk-680-zw-1662305-t-384526-4026415120009?dc=GB&cu=EUR 2026-08-27 697.98 United Kingdom GB DE 14
Casing made of dimensionally stable sheet steel, fully insulated.
Integrated, low-noise centrifugal fan with three-speed adjustable, thermally protected drive motor, statically and dynamically balanced.
Air inlet from the rear (horizontal) or bottom (vertical) with large-surface
Air outlet at the front (horizontal) or top (vertical) via a free air outlet opening to accommodate a connection duct.
Air cooler or air heater as heat exchanger in Cu/Al design made of seamlessly drawn copper pipe with form-fit aluminium fins for cold or hot water or water/glycol mixture up to max. 80°C. Tightness tested at the factory. Brass pipe connections in imperial design with bleed and drain valves provided on the left-hand side of the appliance at the factory. Depending on the installation variant, the coil connection side and the condensate connection can be exchanged.
Insulated condensate tray made of sheet steel for vertical installation and another condensate tray made of sheet steel for horizontal installation. Condensate connection on the side of the appliance.
Electrical connection terminals on the side of the appliance.
The medium flow rate can be regulated using an optional 3-way valve assembly on the appliance. The appliance can be extended for a four-pipe system by installing an additional heating coil.
Available as accessories:
Condensate pump, room temperature control for surface mounting, switching relay for 4 devices, heating coil for four-pipe system, valve assembly two-pipe system, valve assembly four-pipe system, duct angle 90° air inlet, duct angle 90° air outlet, grille in aluminium, for air inlet, grille in aluminium for air outlet, electrical heating resistor, fault signal module
The devices comply with the relevant EU regulations and are CE-marked in accordance with the applicable directives.
Technical performance data:
MakeREMKO
TypeKWK 680 ZW
Nominal cooling capacity, total 1) [kW]6.8
Nominal cooling capacity, sensitive 1) [kW]5.36
Nominal heating capacity 2) [kW]7.54
Application area (room volume), approx. [m³]220
Working range, indoor unit [°C]+15 to +35
Air volume flow, per stage [m³/h]538/843/1203
Sound pressure level, per stage 3) [dB(A)]32/43/51
Voltage supply [V/~/Hz]230/1/50
Protection classIP X0
Electr. Rated power consumption cooling 1) [W]145
Rated electrical current consumption cooling 1) [A]0.69
Operating medium max. 35% ethylene/propylene glycol
Operating pressure, max. medium [kPa Medium [kPa]600
Nominal volume flow, medium cooling 1) [m³/h]1.17
Nominal volume flow, medium heating 2) [m³/h]1.3
Nominal pressure losses, internal cooling 1) [kPa]18
Nominal pressure losses, internal heating 2) [kPa]33, 5
Medium connections1/2”
Medium capacity [l]2.4
Condensate connection [mm]19
Dimensions (H/W/D) [mm]226/1210/493
Weight [kg]25.0
1) Air inlet TK 27°C / FK 19°C, medium temperatures 7/12 °C, 0% glycol concentration, max. air volume flow rate
2) Air inlet 20°C, medium temperatures 45/40 °C, 0% glycol concentration, max. air volume flow rate
3) Distance 1.0 m in a 100m² room with a reverberation time of 0.3s T-384526 1662305 4026415120009 en ["de","en","it","nl","nl","fr","es","pl","pt","cs","da","sv"] https://www.toolteam.com/en-GB/remko-air-conditioning-cold-water-kwk-680-zw-1662305-t-384526-4026415120009?dc=GB&cu=EUR 2026-08-27 697.98 United Kingdom GB DE 14