zoom_in
zoom_out
fullscreen
Remko Air conditioning cold water DKT 51-4 1611322
Sku: T-383770
Discontinued item
Product variants
| Sku: | Name: | SKU manufacturer: | ||
|---|---|---|---|---|
|
T-383766 | Air conditioning cold water DKT 21-4 | 1611302 | |
|
T-383777 | Air conditioning cold water DKT 71-4 | 1611342 |
doneProduct group: 4001
doneType: STD
doneType: STD
doneMade in Germany
Remko air conditioning cold water DKT 51-4 1611322
Product data
Manufacturer:
REMKO GmbH & Co. KG
Condition:
NEW
Sku:
T-383770
SKU manufacturer:
1611322
GTIN Code (EAN):
4026415112738
Weight:
29,50 Kg
All information relating to products from REMKO GmbH & Co. KG. Technical and optical modifications of the manufacturer and errors reserved.
This page has been machine-translated, the original german version can be found here, please also note the Translation Disclaimer.
Product description
Chilled water ceiling cassette for installation in false ceilings with Euroraster dimensions in the four-pipe system for connecting external controls.
Elegant cover made of white, impact-resistant plastic. Housing made of dimensionally stable sheet steel, fully insulated.
Smooth, low-noise centrifugal fan with three-speed adjustable, thermally protected drive motor, statically and dynamically balanced. Manual pre-selection of stages via external input. Protection against external influences by grille inside the unit.
Air inlet in the centre of the cover with large air inlet grille and regenerable air filter behind it.
Air outlet via 4 air outlet openings with manually adjustable swing louvres.
Air cooler as single circular heat exchanger in Cu/Al design made of seamlessly drawn copper pipe with form-fit aluminium fins for cold or hot water or water/glycol mixture up to max. 80°C. Tightness tested at the factory. Brass pipe connections in imperial design with vent valves on the side of the appliance.
Insulated condensate tray made of plastic and internal condensate pump with a max. delivery head of 500 mmWS from the bottom edge of the appliance. Pump operation activated by float switch when cooling is required, safety switch-off by float switch if the amount of condensate is too high and the cooling valve is switched off. Condensate connection hose on the side of the appliance inside the false ceiling. Electrical switch box with connection terminals on the side of the unit inside the suspended ceiling.
The unit can be controlled via an external controller, BMS or similar with outputs ‘Cooling request’, ‘Heating request’, ‘Fan speed 1’, ‘Fan speed 2’ and ‘Fan speed 3’. Restart possible after power failure.
The medium volume flow in cooling mode is controlled by a standard 3-way valve assembly ‘Cooling’ on the device.
Heating mode is controlled on site.
The devices comply with the relevant EU regulations and are CE-labelled in accordance with the applicable directives.
Included in the standard scope of delivery:
Cover
Internal condensate pump
Connection option for outside air supply and second room cooling
Three-way valve assembly ‘Cooling’
Available as accessories:
External condensate pump
Room temperature control
Technical performance data:
MakeREMKO
TypeDKT 51-4
Nominal cooling capacity 1) [kW]4.10
Nominal cooling capacity, sensitive 1) [kW]3.30
Nominal heating capacity 2) [kW]6, 80
Air volume flow per stage [m³/h]485/625/900
Sound pressure level per stage 3) [dB(A)]33/39/48
Voltage supply [V/~/Hz]230/1/50
Electr. Nominal power consumption [kW]0.09
Nominal electrical current consumption [A]0.41
Operating medium max. 35% glycol
Operating limits medium [°C]+4 to +80
Operating pressure, max, Medium [kPA]1400
Nominal volume flow, medium K/H [m³/h]0.71/0.59
Nominal pressure loss, internal cooling [kPa]13.10
Nominal pressure loss, internal heating [kPa]29, 20
Medium connections cooling3/4 ‘
Medium connections heating1/2 ’
Dimensions unit (H/W/D) [mm]298/570/570
Dimensions cover (H/W/D) [mm]30/720/720
Weight [kg]24.2
1) Room temperature TK 27°C, FK 19°C, medium inlet 12°C, medium outlet 7°C, 0% glycol concentration, max. air volume flow2) Room temperature TK 27°C, FK 19°C, medium inlet 12°C, medium outlet 7°C, 0% glycol concentration, max. air volume flow air flow rate
2) Room temperature TK 20°C, FK 19°C, medium inlet 70°C, medium outlet 60°C, 0% glycol concentration, max. air flow rate
3) Distance 1 m free field with hypothetical sound attenuation in the room of -9dB(A)
Elegant cover made of white, impact-resistant plastic. Housing made of dimensionally stable sheet steel, fully insulated.
Smooth, low-noise centrifugal fan with three-speed adjustable, thermally protected drive motor, statically and dynamically balanced. Manual pre-selection of stages via external input. Protection against external influences by grille inside the unit.
Air inlet in the centre of the cover with large air inlet grille and regenerable air filter behind it.
Air outlet via 4 air outlet openings with manually adjustable swing louvres.
Air cooler as single circular heat exchanger in Cu/Al design made of seamlessly drawn copper pipe with form-fit aluminium fins for cold or hot water or water/glycol mixture up to max. 80°C. Tightness tested at the factory. Brass pipe connections in imperial design with vent valves on the side of the appliance.
Insulated condensate tray made of plastic and internal condensate pump with a max. delivery head of 500 mmWS from the bottom edge of the appliance. Pump operation activated by float switch when cooling is required, safety switch-off by float switch if the amount of condensate is too high and the cooling valve is switched off. Condensate connection hose on the side of the appliance inside the false ceiling. Electrical switch box with connection terminals on the side of the unit inside the suspended ceiling.
The unit can be controlled via an external controller, BMS or similar with outputs ‘Cooling request’, ‘Heating request’, ‘Fan speed 1’, ‘Fan speed 2’ and ‘Fan speed 3’. Restart possible after power failure.
The medium volume flow in cooling mode is controlled by a standard 3-way valve assembly ‘Cooling’ on the device.
Heating mode is controlled on site.
The devices comply with the relevant EU regulations and are CE-labelled in accordance with the applicable directives.
Included in the standard scope of delivery:
Cover
Internal condensate pump
Connection option for outside air supply and second room cooling
Three-way valve assembly ‘Cooling’
Available as accessories:
External condensate pump
Room temperature control
Technical performance data:
MakeREMKO
TypeDKT 51-4
Nominal cooling capacity 1) [kW]4.10
Nominal cooling capacity, sensitive 1) [kW]3.30
Nominal heating capacity 2) [kW]6, 80
Air volume flow per stage [m³/h]485/625/900
Sound pressure level per stage 3) [dB(A)]33/39/48
Voltage supply [V/~/Hz]230/1/50
Electr. Nominal power consumption [kW]0.09
Nominal electrical current consumption [A]0.41
Operating medium max. 35% glycol
Operating limits medium [°C]+4 to +80
Operating pressure, max, Medium [kPA]1400
Nominal volume flow, medium K/H [m³/h]0.71/0.59
Nominal pressure loss, internal cooling [kPa]13.10
Nominal pressure loss, internal heating [kPa]29, 20
Medium connections cooling3/4 ‘
Medium connections heating1/2 ’
Dimensions unit (H/W/D) [mm]298/570/570
Dimensions cover (H/W/D) [mm]30/720/720
Weight [kg]24.2
1) Room temperature TK 27°C, FK 19°C, medium inlet 12°C, medium outlet 7°C, 0% glycol concentration, max. air volume flow2) Room temperature TK 27°C, FK 19°C, medium inlet 12°C, medium outlet 7°C, 0% glycol concentration, max. air volume flow air flow rate
2) Room temperature TK 20°C, FK 19°C, medium inlet 70°C, medium outlet 60°C, 0% glycol concentration, max. air flow rate
3) Distance 1 m free field with hypothetical sound attenuation in the room of -9dB(A)
Additional information
Product group:
4001
Width (mm):
570.0MMT
Height (mm):
298.0MMT
Length (mm):
570.0MMT
Type:
STD
Related results
Complete catalogs
The offer is aimed exclusively at business customers, companies, public institutions, tradesmen and freelancers. All prices in catalogues are exclusive of VAT, shipping costs and surcharges if applicable.
The manufacturer is exclusively responsible for the content, price and article details of the products and offers presented in the catalogues. Subject to technical and optical changes by the manufacturer and errors excepted.
The manufacturer is exclusively responsible for the content, price and article details of the products and offers presented in the catalogues. Subject to technical and optical changes by the manufacturer and errors excepted.
Matching catalog
Commercial customer offer**
Product suggestions
-14%
Relay board WP-Manager (WMZ version) CMT 120/160
1120194
€297.69
-19%
RK WP Fresh water station
260182
€4,611.92
€5,680.00 MSRP
Oil nozzle 1.75/80 size S DZH 90
1107372
€25.00
-14%
Control board RVT 681 DC AT
1109849
€453.07
-13%
Outer sheath PGT 100
1101681
€227.48
-4%
Support ring, 1-piece RK 25-50
1104168
€43.87
Condensate nozzle RVD 1054 DC IT
1114438
€9.20
-4%
Quick coupling suction line BL 263/353 DC AT
1113540
€53.49
-13%
Power board 954460 RVS
1106710
€128.53
-19%
ATY 527 Deco
1623434
€658.19
€810.00 MSRP
Accessory pack 1
1106445
€21.67
-10%
Reversing valve RXT 681 DC AT
1111598
€73.78
-10%
Injection nozzle No. 06 RVS 1600
1107332
€77.22
-4%
Condensate container ETF/AMT
1104429
€61.09
-10%
Device cover SKW 520 IT
1113560
€62.51
No Review yet
Description: No Review yet
Written by: No Review
Rating: 5 out of 5
5 stars, based on 1
reviews
Remko Air conditioning cold water DKT 51-4 1611322
REMKO GmbH & Co. KG 1611322
Remko 1611322
1611322
4026415112738
chilled water air conditioning systems
Chilled water ceiling cassette for installation in false ceilings with Euroraster dimensions in the four-pipe system for connecting external controls.
Elegant cover made of white, impact-resistant plastic. Housing made of dimensionally stable sheet steel, fully insulated.
Smooth, low-noise centrifugal fan with three-speed adjustable, thermally protected drive motor, statically and dynamically balanced. Manual pre-selection of stages via external input. Protection against external influences by grille inside the unit.
Air inlet in the centre of the cover with large air inlet grille and regenerable air filter behind it.
Air outlet via 4 air outlet openings with manually adjustable swing louvres.
Air cooler as single circular heat exchanger in Cu/Al design made of seamlessly drawn copper pipe with form-fit aluminium fins for cold or hot water or water/glycol mixture up to max. 80°C. Tightness tested at the factory. Brass pipe connections in imperial design with vent valves on the side of the appliance.
Insulated condensate tray made of plastic and internal condensate pump with a max. delivery head of 500 mmWS from the bottom edge of the appliance. Pump operation activated by float switch when cooling is required, safety switch-off by float switch if the amount of condensate is too high and the cooling valve is switched off. Condensate connection hose on the side of the appliance inside the false ceiling. Electrical switch box with connection terminals on the side of the unit inside the suspended ceiling.
The unit can be controlled via an external controller, BMS or similar with outputs ‘Cooling request’, ‘Heating request’, ‘Fan speed 1’, ‘Fan speed 2’ and ‘Fan speed 3’. Restart possible after power failure.
The medium volume flow in cooling mode is controlled by a standard 3-way valve assembly ‘Cooling’ on the device.
Heating mode is controlled on site.
The devices comply with the relevant EU regulations and are CE-labelled in accordance with the applicable directives.
Included in the standard scope of delivery:
Cover
Internal condensate pump
Connection option for outside air supply and second room cooling
Three-way valve assembly ‘Cooling’
Available as accessories:
External condensate pump
Room temperature control
Technical performance data:
MakeREMKO
TypeDKT 51-4
Nominal cooling capacity 1) [kW]4.10
Nominal cooling capacity, sensitive 1) [kW]3.30
Nominal heating capacity 2) [kW]6, 80
Air volume flow per stage [m³/h]485/625/900
Sound pressure level per stage 3) [dB(A)]33/39/48
Voltage supply [V/~/Hz]230/1/50
Electr. Nominal power consumption [kW]0.09
Nominal electrical current consumption [A]0.41
Operating medium max. 35% glycol
Operating limits medium [°C]+4 to +80
Operating pressure, max, Medium [kPA]1400
Nominal volume flow, medium K/H [m³/h]0.71/0.59
Nominal pressure loss, internal cooling [kPa]13.10
Nominal pressure loss, internal heating [kPa]29, 20
Medium connections cooling3/4 ‘
Medium connections heating1/2 ’
Dimensions unit (H/W/D) [mm]298/570/570
Dimensions cover (H/W/D) [mm]30/720/720
Weight [kg]24.2
1) Room temperature TK 27°C, FK 19°C, medium inlet 12°C, medium outlet 7°C, 0% glycol concentration, max. air volume flow2) Room temperature TK 27°C, FK 19°C, medium inlet 12°C, medium outlet 7°C, 0% glycol concentration, max. air volume flow air flow rate
2) Room temperature TK 20°C, FK 19°C, medium inlet 70°C, medium outlet 60°C, 0% glycol concentration, max. air flow rate
3) Distance 1 m free field with hypothetical sound attenuation in the room of -9dB(A) T-383770 1611322 4026415112738 en ["de","en","it","nl","nl","fr","es","pl","pt","cs","da","sv"] https://www.toolteam.com/en-GB/remko-air-conditioning-cold-water-dkt-51-4-1611322-t-383770-4026415112738?dc=GB&cu=EUR 2026-08-05 2092.39 United Kingdom GB DE 14
Elegant cover made of white, impact-resistant plastic. Housing made of dimensionally stable sheet steel, fully insulated.
Smooth, low-noise centrifugal fan with three-speed adjustable, thermally protected drive motor, statically and dynamically balanced. Manual pre-selection of stages via external input. Protection against external influences by grille inside the unit.
Air inlet in the centre of the cover with large air inlet grille and regenerable air filter behind it.
Air outlet via 4 air outlet openings with manually adjustable swing louvres.
Air cooler as single circular heat exchanger in Cu/Al design made of seamlessly drawn copper pipe with form-fit aluminium fins for cold or hot water or water/glycol mixture up to max. 80°C. Tightness tested at the factory. Brass pipe connections in imperial design with vent valves on the side of the appliance.
Insulated condensate tray made of plastic and internal condensate pump with a max. delivery head of 500 mmWS from the bottom edge of the appliance. Pump operation activated by float switch when cooling is required, safety switch-off by float switch if the amount of condensate is too high and the cooling valve is switched off. Condensate connection hose on the side of the appliance inside the false ceiling. Electrical switch box with connection terminals on the side of the unit inside the suspended ceiling.
The unit can be controlled via an external controller, BMS or similar with outputs ‘Cooling request’, ‘Heating request’, ‘Fan speed 1’, ‘Fan speed 2’ and ‘Fan speed 3’. Restart possible after power failure.
The medium volume flow in cooling mode is controlled by a standard 3-way valve assembly ‘Cooling’ on the device.
Heating mode is controlled on site.
The devices comply with the relevant EU regulations and are CE-labelled in accordance with the applicable directives.
Included in the standard scope of delivery:
Cover
Internal condensate pump
Connection option for outside air supply and second room cooling
Three-way valve assembly ‘Cooling’
Available as accessories:
External condensate pump
Room temperature control
Technical performance data:
MakeREMKO
TypeDKT 51-4
Nominal cooling capacity 1) [kW]4.10
Nominal cooling capacity, sensitive 1) [kW]3.30
Nominal heating capacity 2) [kW]6, 80
Air volume flow per stage [m³/h]485/625/900
Sound pressure level per stage 3) [dB(A)]33/39/48
Voltage supply [V/~/Hz]230/1/50
Electr. Nominal power consumption [kW]0.09
Nominal electrical current consumption [A]0.41
Operating medium max. 35% glycol
Operating limits medium [°C]+4 to +80
Operating pressure, max, Medium [kPA]1400
Nominal volume flow, medium K/H [m³/h]0.71/0.59
Nominal pressure loss, internal cooling [kPa]13.10
Nominal pressure loss, internal heating [kPa]29, 20
Medium connections cooling3/4 ‘
Medium connections heating1/2 ’
Dimensions unit (H/W/D) [mm]298/570/570
Dimensions cover (H/W/D) [mm]30/720/720
Weight [kg]24.2
1) Room temperature TK 27°C, FK 19°C, medium inlet 12°C, medium outlet 7°C, 0% glycol concentration, max. air volume flow2) Room temperature TK 27°C, FK 19°C, medium inlet 12°C, medium outlet 7°C, 0% glycol concentration, max. air volume flow air flow rate
2) Room temperature TK 20°C, FK 19°C, medium inlet 70°C, medium outlet 60°C, 0% glycol concentration, max. air flow rate
3) Distance 1 m free field with hypothetical sound attenuation in the room of -9dB(A) T-383770 1611322 4026415112738 en ["de","en","it","nl","nl","fr","es","pl","pt","cs","da","sv"] https://www.toolteam.com/en-GB/remko-air-conditioning-cold-water-dkt-51-4-1611322-t-383770-4026415112738?dc=GB&cu=EUR 2026-08-05 2092.39 United Kingdom GB DE 14