zoom_in
zoom_out
fullscreen
Remko Air conditioning cold water CHP 300 ZW 1662265
Sku: T-384518
Discontinued item
Product variants
| Sku: | Name: | SKU manufacturer: | ||
|---|---|---|---|---|
|
T-384508 | Air conditioning cold water KWK 130 ZW | 1662215 | |
|
T-384510 | Air conditioning cold water CHP 140 ZW | 1662225 | |
|
T-384512 | Air conditioning cold water KWK 200 ZW | 1662235 | |
|
T-384514 | Air conditioning cold water KWK 220 ZW | 1662245 | |
|
T-384516 | Air conditioning cold water KWK 280 ZW | 1662255 | |
|
T-384520 | Air conditioning cold water KWK 360 ZW | 1662275 | |
|
T-384522 | Air conditioning cold water KWK 420 ZW | 1662285 | |
|
T-384524 | Air conditioning cold water KWK 590 ZW | 1662295 | |
|
T-384526 | Air conditioning cold water KWK 680 ZW | 1662305 | |
|
T-384528 | Air conditioning cold water KWK 740 ZW | 1662315 | |
|
T-384530 | Air conditioning cold water KWK 870 ZW | 1662325 | |
|
T-384535 | Air conditioning chilled water KWK 140 EC ZW | 1662505 | |
|
T-384537 | Air conditioning chilled water KWK 220 EC ZW | 1662515 | |
|
T-384539 | Air conditioning cold water KWK 300 EC ZW | 1662525 | |
|
T-384541 | Air conditioning cold water KWK 500 EC ZW | 1662535 | |
|
T-384543 | Air conditioning chilled water KWK 690 EC ZW | 1662545 | |
|
T-384545 | Air conditioning cold water KWK 830 EC ZW | 1662555 |
doneProduct group: 4001
doneType: STD
doneType: STD
Remko Klima cold water KWK 300 ZW 1662265
Product data
Manufacturer:
REMKO GmbH & Co. KG
Condition:
NEW
Sku:
T-384518
SKU manufacturer:
1662265
GTIN Code (EAN):
4026415119928
Weight:
23,00 Kg
All information relating to products from REMKO GmbH & Co. KG. Technical and optical modifications of the manufacturer and errors reserved.
This page has been machine-translated, the original german version can be found here, please also note the Translation Disclaimer.
Product description
Chilled water chest unit for installation in intermediate spaces for wall or ceiling mounting without cover in a two-pipe system.
Casing made of dimensionally stable sheet steel, fully insulated.
Integrated, low-noise centrifugal fan with three-speed adjustable, thermally protected drive motor, statically and dynamically balanced.
Air inlet from the rear (horizontal) or bottom (vertical) with large-surface
Air outlet at the front (horizontal) or top (vertical) via a free air outlet opening to accommodate a connection duct.
Air cooler or air heater as heat exchanger in Cu/Al design made of seamlessly drawn copper pipe with form-fit aluminium fins for cold or hot water or water/glycol mixture up to max. 80°C. Tightness tested at the factory. Brass pipe connections in imperial design with bleed and drain valves provided on the left-hand side of the appliance at the factory. Depending on the installation variant, the coil connection side and the condensate connection can be exchanged.
Insulated condensate tray made of sheet steel for vertical installation and another condensate tray made of sheet steel for horizontal installation. Condensate connection on the side of the appliance.
Electrical connection terminals on the side of the appliance.
The medium flow rate can be regulated using an optional 3-way valve assembly on the appliance. The appliance can be extended for a four-pipe system by installing an additional heating coil.
Available as accessories:
Condensate pump, room temperature control for surface mounting, switching relay for 4 devices, heating coil for four-pipe system, valve assembly two-pipe system, valve assembly four-pipe system, duct angle 90° air inlet, duct angle 90° air outlet, grille in aluminium, for air inlet, grille in aluminium for air outlet, electrical heating resistor, fault signal module
The devices comply with the relevant EU regulations and are CE-marked in accordance with the applicable directives.
Technical performance data:
MakeREMKO
TypeKWK 300 ZW
Nominal cooling capacity, total 1) [kW]3.11
Nominal cooling capacity, sensitive 1) [kW]2.57
Nominal heating capacity 2) [kW]3.69
Application area (room volume), approx. [m³]100
Working range, indoor unit [°C]+15 to +35
Air volume flow, per stage [m³/h]294/451/610
Sound pressure level, per stage 3) [dB(A)]28/38/45
Voltage supply [V/~/Hz]230/1/50
Protection classIP X0
Electr. Rated power consumption cooling 1) [W]65
Rated electrical current consumption cooling 1) [A]0.31
Operating medium max. 35% ethylene/propylene glycol
Operating pressure, max. medium [kPa Medium [kPa]600
Nominal volume flow, medium cooling 1) [m³/h]0.53
Nominal volume flow, medium heating 2) [m³/h]0.63
Nominal pressure losses, internal cooling 1) [kPa]9.5
Nominal pressure losses, internal heating 2) [kPa]11, 2
Medium connections1/2”
Medium capacity [l]1.1
Condensate connection [mm]19
Dimensions (H/W/D) [mm]216/760/446
Weight [kg]13.0
1) Air inlet TK 27°C / FK 19°C, medium temperatures 7/12 °C, 0% glycol concentration, max. air volume flow rate
2) Air inlet 20°C, medium temperatures 45/40 °C, 0% glycol concentration, max. air volume flow rate
3) Distance 1.0 m in a 100m² room with a reverberation time of 0.3s
Casing made of dimensionally stable sheet steel, fully insulated.
Integrated, low-noise centrifugal fan with three-speed adjustable, thermally protected drive motor, statically and dynamically balanced.
Air inlet from the rear (horizontal) or bottom (vertical) with large-surface
Air outlet at the front (horizontal) or top (vertical) via a free air outlet opening to accommodate a connection duct.
Air cooler or air heater as heat exchanger in Cu/Al design made of seamlessly drawn copper pipe with form-fit aluminium fins for cold or hot water or water/glycol mixture up to max. 80°C. Tightness tested at the factory. Brass pipe connections in imperial design with bleed and drain valves provided on the left-hand side of the appliance at the factory. Depending on the installation variant, the coil connection side and the condensate connection can be exchanged.
Insulated condensate tray made of sheet steel for vertical installation and another condensate tray made of sheet steel for horizontal installation. Condensate connection on the side of the appliance.
Electrical connection terminals on the side of the appliance.
The medium flow rate can be regulated using an optional 3-way valve assembly on the appliance. The appliance can be extended for a four-pipe system by installing an additional heating coil.
Available as accessories:
Condensate pump, room temperature control for surface mounting, switching relay for 4 devices, heating coil for four-pipe system, valve assembly two-pipe system, valve assembly four-pipe system, duct angle 90° air inlet, duct angle 90° air outlet, grille in aluminium, for air inlet, grille in aluminium for air outlet, electrical heating resistor, fault signal module
The devices comply with the relevant EU regulations and are CE-marked in accordance with the applicable directives.
Technical performance data:
MakeREMKO
TypeKWK 300 ZW
Nominal cooling capacity, total 1) [kW]3.11
Nominal cooling capacity, sensitive 1) [kW]2.57
Nominal heating capacity 2) [kW]3.69
Application area (room volume), approx. [m³]100
Working range, indoor unit [°C]+15 to +35
Air volume flow, per stage [m³/h]294/451/610
Sound pressure level, per stage 3) [dB(A)]28/38/45
Voltage supply [V/~/Hz]230/1/50
Protection classIP X0
Electr. Rated power consumption cooling 1) [W]65
Rated electrical current consumption cooling 1) [A]0.31
Operating medium max. 35% ethylene/propylene glycol
Operating pressure, max. medium [kPa Medium [kPa]600
Nominal volume flow, medium cooling 1) [m³/h]0.53
Nominal volume flow, medium heating 2) [m³/h]0.63
Nominal pressure losses, internal cooling 1) [kPa]9.5
Nominal pressure losses, internal heating 2) [kPa]11, 2
Medium connections1/2”
Medium capacity [l]1.1
Condensate connection [mm]19
Dimensions (H/W/D) [mm]216/760/446
Weight [kg]13.0
1) Air inlet TK 27°C / FK 19°C, medium temperatures 7/12 °C, 0% glycol concentration, max. air volume flow rate
2) Air inlet 20°C, medium temperatures 45/40 °C, 0% glycol concentration, max. air volume flow rate
3) Distance 1.0 m in a 100m² room with a reverberation time of 0.3s
Additional information
Product group:
4001
Width (mm):
760.0MMT
Height (mm):
216.0MMT
Length (mm):
446.0MMT
Type:
STD
Related results
Complete catalogs
The offer is aimed exclusively at business customers, companies, public institutions, tradesmen and freelancers. All prices in catalogues are exclusive of VAT, shipping costs and surcharges if applicable.
The manufacturer is exclusively responsible for the content, price and article details of the products and offers presented in the catalogues. Subject to technical and optical changes by the manufacturer and errors excepted.
The manufacturer is exclusively responsible for the content, price and article details of the products and offers presented in the catalogues. Subject to technical and optical changes by the manufacturer and errors excepted.
Matching catalog
Commercial customer offer**
Product suggestions
-10%
Base plate AMT 65/85-E
1105957
€118.53
-4%
Housing front BL 353 DC IT/SKW 350 DC IT
1113452
€63.32
-4%
Insert (Vent. plug)
1108317
€33.95
Condensate nozzle RVD 1054 DC IT
1114438
€9.20
-13%
Outer sheath PGT 100
1101681
€227.48
-13%
Oil pump AD1L2 Replacement for V1-LR2 1/4?
1108640
€159.20
RK Netzstecker
1123916
€12.82
-19%
ZA axial fan 501-4
1108376
€808.06
€994.41 MSRP
-10%
Injection nozzle No. 06 RVS 1600
1107332
€77.22
-14%
ATY 357 Deco
1623432
€531.30
-4%
Pressure gauge 0-6 bar 1/4?
1108426
€59.16
-4%
Quick coupling suction line BL 263/353 DC AT
1113540
€53.49
-10%
Device cover SKW 520 IT
1113560
€62.51
-19%
RK sound insulation hood SWK 5.1,
260939
€2,015.21
€2,480.00 MSRP
-14%
Relay board WP-Manager (WMZ version) CMT 120/160
1120194
€297.69
No Review yet
Description: No Review yet
Written by: No Review
Rating: 5 out of 5
5 stars, based on 1
reviews
Remko Air conditioning cold water CHP 300 ZW 1662265
REMKO GmbH & Co. KG 1662265
Remko 1662265
1662265
4026415119928
chilled water air conditioning systems
Chilled water chest unit for installation in intermediate spaces for wall or ceiling mounting without cover in a two-pipe system.
Casing made of dimensionally stable sheet steel, fully insulated.
Integrated, low-noise centrifugal fan with three-speed adjustable, thermally protected drive motor, statically and dynamically balanced.
Air inlet from the rear (horizontal) or bottom (vertical) with large-surface
Air outlet at the front (horizontal) or top (vertical) via a free air outlet opening to accommodate a connection duct.
Air cooler or air heater as heat exchanger in Cu/Al design made of seamlessly drawn copper pipe with form-fit aluminium fins for cold or hot water or water/glycol mixture up to max. 80°C. Tightness tested at the factory. Brass pipe connections in imperial design with bleed and drain valves provided on the left-hand side of the appliance at the factory. Depending on the installation variant, the coil connection side and the condensate connection can be exchanged.
Insulated condensate tray made of sheet steel for vertical installation and another condensate tray made of sheet steel for horizontal installation. Condensate connection on the side of the appliance.
Electrical connection terminals on the side of the appliance.
The medium flow rate can be regulated using an optional 3-way valve assembly on the appliance. The appliance can be extended for a four-pipe system by installing an additional heating coil.
Available as accessories:
Condensate pump, room temperature control for surface mounting, switching relay for 4 devices, heating coil for four-pipe system, valve assembly two-pipe system, valve assembly four-pipe system, duct angle 90° air inlet, duct angle 90° air outlet, grille in aluminium, for air inlet, grille in aluminium for air outlet, electrical heating resistor, fault signal module
The devices comply with the relevant EU regulations and are CE-marked in accordance with the applicable directives.
Technical performance data:
MakeREMKO
TypeKWK 300 ZW
Nominal cooling capacity, total 1) [kW]3.11
Nominal cooling capacity, sensitive 1) [kW]2.57
Nominal heating capacity 2) [kW]3.69
Application area (room volume), approx. [m³]100
Working range, indoor unit [°C]+15 to +35
Air volume flow, per stage [m³/h]294/451/610
Sound pressure level, per stage 3) [dB(A)]28/38/45
Voltage supply [V/~/Hz]230/1/50
Protection classIP X0
Electr. Rated power consumption cooling 1) [W]65
Rated electrical current consumption cooling 1) [A]0.31
Operating medium max. 35% ethylene/propylene glycol
Operating pressure, max. medium [kPa Medium [kPa]600
Nominal volume flow, medium cooling 1) [m³/h]0.53
Nominal volume flow, medium heating 2) [m³/h]0.63
Nominal pressure losses, internal cooling 1) [kPa]9.5
Nominal pressure losses, internal heating 2) [kPa]11, 2
Medium connections1/2”
Medium capacity [l]1.1
Condensate connection [mm]19
Dimensions (H/W/D) [mm]216/760/446
Weight [kg]13.0
1) Air inlet TK 27°C / FK 19°C, medium temperatures 7/12 °C, 0% glycol concentration, max. air volume flow rate
2) Air inlet 20°C, medium temperatures 45/40 °C, 0% glycol concentration, max. air volume flow rate
3) Distance 1.0 m in a 100m² room with a reverberation time of 0.3s T-384518 1662265 4026415119928 en ["de","en","it","nl","nl","fr","es","pl","pt","cs","da","sv"] https://www.toolteam.com/en-GB/remko-air-conditioning-cold-water-chp-300-zw-1662265-t-384518-4026415119928?dc=GB&cu=EUR 2026-08-16 557.02 United Kingdom GB DE 14
Casing made of dimensionally stable sheet steel, fully insulated.
Integrated, low-noise centrifugal fan with three-speed adjustable, thermally protected drive motor, statically and dynamically balanced.
Air inlet from the rear (horizontal) or bottom (vertical) with large-surface
Air outlet at the front (horizontal) or top (vertical) via a free air outlet opening to accommodate a connection duct.
Air cooler or air heater as heat exchanger in Cu/Al design made of seamlessly drawn copper pipe with form-fit aluminium fins for cold or hot water or water/glycol mixture up to max. 80°C. Tightness tested at the factory. Brass pipe connections in imperial design with bleed and drain valves provided on the left-hand side of the appliance at the factory. Depending on the installation variant, the coil connection side and the condensate connection can be exchanged.
Insulated condensate tray made of sheet steel for vertical installation and another condensate tray made of sheet steel for horizontal installation. Condensate connection on the side of the appliance.
Electrical connection terminals on the side of the appliance.
The medium flow rate can be regulated using an optional 3-way valve assembly on the appliance. The appliance can be extended for a four-pipe system by installing an additional heating coil.
Available as accessories:
Condensate pump, room temperature control for surface mounting, switching relay for 4 devices, heating coil for four-pipe system, valve assembly two-pipe system, valve assembly four-pipe system, duct angle 90° air inlet, duct angle 90° air outlet, grille in aluminium, for air inlet, grille in aluminium for air outlet, electrical heating resistor, fault signal module
The devices comply with the relevant EU regulations and are CE-marked in accordance with the applicable directives.
Technical performance data:
MakeREMKO
TypeKWK 300 ZW
Nominal cooling capacity, total 1) [kW]3.11
Nominal cooling capacity, sensitive 1) [kW]2.57
Nominal heating capacity 2) [kW]3.69
Application area (room volume), approx. [m³]100
Working range, indoor unit [°C]+15 to +35
Air volume flow, per stage [m³/h]294/451/610
Sound pressure level, per stage 3) [dB(A)]28/38/45
Voltage supply [V/~/Hz]230/1/50
Protection classIP X0
Electr. Rated power consumption cooling 1) [W]65
Rated electrical current consumption cooling 1) [A]0.31
Operating medium max. 35% ethylene/propylene glycol
Operating pressure, max. medium [kPa Medium [kPa]600
Nominal volume flow, medium cooling 1) [m³/h]0.53
Nominal volume flow, medium heating 2) [m³/h]0.63
Nominal pressure losses, internal cooling 1) [kPa]9.5
Nominal pressure losses, internal heating 2) [kPa]11, 2
Medium connections1/2”
Medium capacity [l]1.1
Condensate connection [mm]19
Dimensions (H/W/D) [mm]216/760/446
Weight [kg]13.0
1) Air inlet TK 27°C / FK 19°C, medium temperatures 7/12 °C, 0% glycol concentration, max. air volume flow rate
2) Air inlet 20°C, medium temperatures 45/40 °C, 0% glycol concentration, max. air volume flow rate
3) Distance 1.0 m in a 100m² room with a reverberation time of 0.3s T-384518 1662265 4026415119928 en ["de","en","it","nl","nl","fr","es","pl","pt","cs","da","sv"] https://www.toolteam.com/en-GB/remko-air-conditioning-cold-water-chp-300-zw-1662265-t-384518-4026415119928?dc=GB&cu=EUR 2026-08-16 557.02 United Kingdom GB DE 14