zoom_in
zoom_out
fullscreen
-24%
PCE voltage data logger PCE-VR 10
Sku: T-910329
265,92 € (excl. legal VAT, excl. Shipping)
350,88 € MSRP
In stock,ready for shipping
Piece
Content:
1 Piece
Shipping:
73,87 € Versandservice to United Kingdom
Lieferung:
Provider:
Sales and delivery by ToolTeam Köln
Payment methods:
Returns:
Security:
Product data
Manufacturer:
PCE Deutschland GmbH
Condition:
NEW
Sku:
T-910329
SKU manufacturer:
PCE-VR 10
GTIN Code (EAN):
4250348719355
Weight:
0,28 Kg
All information relating to products from PCE Deutschland GmbH. Technical and optical modifications of the manufacturer and errors reserved.
This page has been machine-translated, the original german version can be found here, please also note the Translation Disclaimer.
Product description
The Voltage Data Logger from PCE Instruments is used to record up to three input channels of 0 ... 3000 mV signals via three input channels. The voltage data logger stores the measured voltages on an SD card in Excel format. To record also higher voltages in the range between 0 ... 10 V a voltage divider can be used. The measured voltages are transmitted via plug-in terminals to the data logger, which displays the corresponding values directly on the display and simultaneously stores them on the memory with the associated time stamp. A scaling of the measuring signal is not necessary, because the measuring values are stored directly as mV-measuring value. Scaling can then be conveniently performed manually in Excel.
The voltage data logger thus determines the pure raw data of the sensors whereby any further processing and data evaluation can be carried out very flexibly via spreadsheet programs such as Excel. In addition to storing the measured values, the voltage data logger displays the values of the respective voltage channels on the large backlit LC display. The maximum resolution is 0.1 mV with an accuracy of 0.5 % + 2 mV. The voltage data logger is operated with 6 AA 1.5 V batteries or a power supply unit. For visualization of the live measured values the data logger from PCE Instruments can be connected to the PC via the serial interface. The storage intervals are adjustable in several steps between 1 second and 600 seconds. Thanks to the robust housing, the voltage data logger can be placed on a table or mounted on a wall. This allows mobile measurements at different locations as well as stationary measurements, e.g. if permanent recordings are to be made at only one plant.
Areas of application for the data logger for voltage If measured values and data have to be recorded, compared and later documented over longer periods of time, data loggers which are usually specially designed for the corresponding variables are suitable in most cases. Often it concerns variables such as temperature, humidity, pressure, energy, light, pollutants or current and voltage. Data loggers consist of a storage medium such as an SD card, an interface (USB, Bluetooth, WLAN...) and at least one channel for the corresponding measured variable. Often there is also the possibility to record different measured variables simultaneously via several channels. The voltage data logger from PCE Instruments is specially designed for the field of electrical voltage measurement and is therefore suitable for parallel recording of voltages on a maximum of three voltage channels.
The voltage data logger is used to record e.g. sensor data which can be read out via a voltage output. The measuring range of up to 3000 mV can be extended for sensors with higher voltages up to 10 V via a voltage divider (see optional accessories). If, for example, physical variables such as temperature, pressure and level are to be recorded and compared simultaneously in a system, the corresponding sensors can be connected to the data logger in order to display and document the changes and mutual dependencies of the three variables after the measurement. The voltage data logger can also be used to compare identical sensors at a measuring point. In this way, sensor errors can be directly excluded before permanent installation and measurement. Air pressures before and after filters can also be checked with suitable sensors in order to test the filter function. The data loggers for voltage are therefore suitable for a wide range of applications in industry, maintenance and repair or research and development.
The voltage data logger thus determines the pure raw data of the sensors whereby any further processing and data evaluation can be carried out very flexibly via spreadsheet programs such as Excel. In addition to storing the measured values, the voltage data logger displays the values of the respective voltage channels on the large backlit LC display. The maximum resolution is 0.1 mV with an accuracy of 0.5 % + 2 mV. The voltage data logger is operated with 6 AA 1.5 V batteries or a power supply unit. For visualization of the live measured values the data logger from PCE Instruments can be connected to the PC via the serial interface. The storage intervals are adjustable in several steps between 1 second and 600 seconds. Thanks to the robust housing, the voltage data logger can be placed on a table or mounted on a wall. This allows mobile measurements at different locations as well as stationary measurements, e.g. if permanent recordings are to be made at only one plant.
Areas of application for the data logger for voltage If measured values and data have to be recorded, compared and later documented over longer periods of time, data loggers which are usually specially designed for the corresponding variables are suitable in most cases. Often it concerns variables such as temperature, humidity, pressure, energy, light, pollutants or current and voltage. Data loggers consist of a storage medium such as an SD card, an interface (USB, Bluetooth, WLAN...) and at least one channel for the corresponding measured variable. Often there is also the possibility to record different measured variables simultaneously via several channels. The voltage data logger from PCE Instruments is specially designed for the field of electrical voltage measurement and is therefore suitable for parallel recording of voltages on a maximum of three voltage channels.
The voltage data logger is used to record e.g. sensor data which can be read out via a voltage output. The measuring range of up to 3000 mV can be extended for sensors with higher voltages up to 10 V via a voltage divider (see optional accessories). If, for example, physical variables such as temperature, pressure and level are to be recorded and compared simultaneously in a system, the corresponding sensors can be connected to the data logger in order to display and document the changes and mutual dependencies of the three variables after the measurement. The voltage data logger can also be used to compare identical sensors at a measuring point. In this way, sensor errors can be directly excluded before permanent installation and measurement. Air pressures before and after filters can also be checked with suitable sensors in order to test the filter function. The data loggers for voltage are therefore suitable for a wide range of applications in industry, maintenance and repair or research and development.
Hinweise zur Batterieentsorgung:
Da in unseren Sendungen Batterien und Akkus enthalten sein können, sind wir nach dem Batteriegesetz (BattG) verpflichtet, Sie auf Folgendes hinzuweisen:
- Batterien und Akkus dürfen nicht im Hausmüll entsorgt werden, sondern Sie sind zur Rückgabe gebrauchter Batterien und Akkus gesetzlich verpflichtet.
- Altbatterien können Schadstoffe enthalten, die bei nicht sachgemäßer Lagerung oder Entsorgung die Umwelt oder Ihre Gesundheit schädigen können. Batterien enthalten aber auch wichtige Rohstoffe wie z.B. Eisen, Zink, Mangan oder Nickel und können verwertet werden.
- Sie können die Batterien nach Gebrauch entweder an uns zurücksenden oder in unmittelbarer Nähe (z.B. im Handel oder in kommunalen Sammelstellen oder in unserem Lager) unentgeltlich zurückgeben.
- Die Abgabe in Verkaufsstellen ist dabei für Endnutzer auf die übliche Mengen sowie solche Altbatterien beschränkt, die der Vertreiber als Neubatterien in seinem Sortiment führt oder geführt hat.
- Das Zeichen mit der durchgekreuzten Mülltonne bedeutet, dass Sie Batterien und Akkus nicht im Hausmüll entsorgen dürfen
Unter diesen Zeichen finden Sie zusätzlich nachstehende Symbole mit folgender Bedeutung:
- Pb = Batterie enthält mehr als 0,004 Masseprozent Blei
- Cd = Batterie enthält mehr als 0,002 Masseprozent Cadmium
- Hg = Batterie enthält mehr als 0,0005 Masseprozent Quecksilber
Related results
pc
pce instruments
measurement technology
control technology
weighing technology
laboratory technology
development
production
calibration
pc
pce instruments
measurement technology
control technology
weighing technology
laboratory technology
development
production
calibration
pce
pce instruments
weighing technology
platform scales
shipping scales
pallet scales
inventory scales
platform scales
industrial scales
multifunctional scales
compact scales
weighing platform
pce
pce instruments
measurement technology
machines
systems
vibration measurement
vibration measuring device
vibration measuring device
accelerometer
stethoscope
data logger
Complete catalogs
The offer is aimed exclusively at business customers, companies, public institutions, tradesmen and freelancers. All prices in catalogues are exclusive of VAT, shipping costs and surcharges if applicable.
The manufacturer is exclusively responsible for the content, price and article details of the products and offers presented in the catalogues. Subject to technical and optical changes by the manufacturer and errors excepted.
The manufacturer is exclusively responsible for the content, price and article details of the products and offers presented in the catalogues. Subject to technical and optical changes by the manufacturer and errors excepted.
Product suggestions
-25%
AW tester PCE-WAM 10
PCE-WAM 10
579,57 €
771,89 € MSRP
-25%
Hydraulic lifting table - industrial scale PCE-HLTS 500
PCE-HLTS 500
3.266,01 €
4.349,91 € MSRP
-24%
Earth Tester PCE-ET 3000
PCE-ET 3000
399,29 €
526,89 € MSRP
-25%
Thickness Gauge PCE-CT 80HP-FN2
PCE-CT 80HP-FN2
733,49 €
976,89 € MSRP
-25%
Drehmoment-Kalibrator
PCE-TCT 100
4.223,32 €
5.624,92 € MSRP
-24%
mold measuring device PCE-PMI 1BT
PCE-PMI 1BT
89,41 €
116,89 € MSRP
-24%
PCE-HS 300N Digital Crane Scale Weighing range (max.) 300 kg | incl. shackle + hook | Accurate ±1% of Mb. | Metal | LCD
PCE-HS 300N
76,39 €
99,91 € MSRP
-25%
Kraftmessgerät
PCE-DFG 50K XF
1.310,13 €
1.744,92 € MSRP
-24%
PCE-PH20M food penetration ph meter | robust PH electrode | recalibratable | waterproof (IP67)
PCE-PH20M
329,58 €
434,92 € MSRP
-24%
Borescope PCE-VE 200SV1
PCE-VE 200SV1
363,69 €
479,92 € MSRP
-24%
Wine Refractometer PCE-DRW 2
PCE-DRW 2
266,68 €
351,89 € MSRP
-25%
Closing Force Measuring Device Original BIA Cl. 1 for Bus and Train Doors
BIA1-SY-10-310
2.654,92 €
3.536,01 € MSRP
-25%
display / built-in display PCE-BPD-U-46A
PCE-BPD-U-46A
568,31 €
756,89 € MSRP
-25%
Feuchtebestimmerwaage
PCE-UX 3011HQ
2.995,80 €
3.990,00 € MSRP
-24%
PCE-BSH 6000 calibratable school scale max. 6 kg|PC software opt.|Counting function g|kg|lb|ct|gn|gsm and much more.
PCE-BSH 6000
174,24 €
229,91 € MSRP
No Review yet
Description: No Review yet
Written by: No Review
Rating: 5 out of 5
5 stars, based on 1
reviews
PCE voltage data logger PCE-VR 10
pc
pce instruments
measurement technology
control technology
weighing technology
laboratory technology
development
production
calibration
pc
pce instruments
measurement technology
control technology
weighing technology
laboratory technology
development
production
calibration
pce
pce instruments
weighing technology
platform scales
shipping scales
pallet scales
inventory scales
platform scales
industrial scales
multifunctional scales
compact scales
weighing platform
pce
pce instruments
measurement technology
machines
systems
vibration measurement
vibration measuring device
vibration measuring device
accelerometer
stethoscope
data logger
The Voltage Data Logger from PCE Instruments is used to record up to three input channels of 0 ... 3000 mV signals via three input channels. The voltage data logger stores the measured voltages on an SD card in Excel format. To record also higher voltages in the range between 0 ... 10 V a voltage divider can be used. The measured voltages are transmitted via plug-in terminals to the data logger, which displays the corresponding values directly on the display and simultaneously stores them on the memory with the associated time stamp. A scaling of the measuring signal is not necessary, because the measuring values are stored directly as mV-measuring value. Scaling can then be conveniently performed manually in Excel.
The voltage data logger thus determines the pure raw data of the sensors whereby any further processing and data evaluation can be carried out very flexibly via spreadsheet programs such as Excel. In addition to storing the measured values, the voltage data logger displays the values of the respective voltage channels on the large backlit LC display. The maximum resolution is 0.1 mV with an accuracy of 0.5 % + 2 mV. The voltage data logger is operated with 6 AA 1.5 V batteries or a power supply unit. For visualization of the live measured values the data logger from PCE Instruments can be connected to the PC via the serial interface. The storage intervals are adjustable in several steps between 1 second and 600 seconds. Thanks to the robust housing, the voltage data logger can be placed on a table or mounted on a wall. This allows mobile measurements at different locations as well as stationary measurements, e.g. if permanent recordings are to be made at only one plant.
Areas of application for the data logger for voltage If measured values and data have to be recorded, compared and later documented over longer periods of time, data loggers which are usually specially designed for the corresponding variables are suitable in most cases. Often it concerns variables such as temperature, humidity, pressure, energy, light, pollutants or current and voltage. Data loggers consist of a storage medium such as an SD card, an interface (USB, Bluetooth, WLAN...) and at least one channel for the corresponding measured variable. Often there is also the possibility to record different measured variables simultaneously via several channels. The voltage data logger from PCE Instruments is specially designed for the field of electrical voltage measurement and is therefore suitable for parallel recording of voltages on a maximum of three voltage channels.
The voltage data logger is used to record e.g. sensor data which can be read out via a voltage output. The measuring range of up to 3000 mV can be extended for sensors with higher voltages up to 10 V via a voltage divider (see optional accessories). If, for example, physical variables such as temperature, pressure and level are to be recorded and compared simultaneously in a system, the corresponding sensors can be connected to the data logger in order to display and document the changes and mutual dependencies of the three variables after the measurement. The voltage data logger can also be used to compare identical sensors at a measuring point. In this way, sensor errors can be directly excluded before permanent installation and measurement. Air pressures before and after filters can also be checked with suitable sensors in order to test the filter function. The data loggers for voltage are therefore suitable for a wide range of applications in industry, maintenance and repair or research and development. T-910329 PCE-VR 10 4250348719355 en ["de","en","it","nl","nl","fr","es","pl","pt","cs","da","sv"] https://www.toolteam.com/en-GB/pce-voltage-data-logger-pce-vr-10-t-910329-4250348719355?dc=GB&cu=EUR 2026-06-04 265.92 United Kingdom GB DE 14
The voltage data logger thus determines the pure raw data of the sensors whereby any further processing and data evaluation can be carried out very flexibly via spreadsheet programs such as Excel. In addition to storing the measured values, the voltage data logger displays the values of the respective voltage channels on the large backlit LC display. The maximum resolution is 0.1 mV with an accuracy of 0.5 % + 2 mV. The voltage data logger is operated with 6 AA 1.5 V batteries or a power supply unit. For visualization of the live measured values the data logger from PCE Instruments can be connected to the PC via the serial interface. The storage intervals are adjustable in several steps between 1 second and 600 seconds. Thanks to the robust housing, the voltage data logger can be placed on a table or mounted on a wall. This allows mobile measurements at different locations as well as stationary measurements, e.g. if permanent recordings are to be made at only one plant.
Areas of application for the data logger for voltage If measured values and data have to be recorded, compared and later documented over longer periods of time, data loggers which are usually specially designed for the corresponding variables are suitable in most cases. Often it concerns variables such as temperature, humidity, pressure, energy, light, pollutants or current and voltage. Data loggers consist of a storage medium such as an SD card, an interface (USB, Bluetooth, WLAN...) and at least one channel for the corresponding measured variable. Often there is also the possibility to record different measured variables simultaneously via several channels. The voltage data logger from PCE Instruments is specially designed for the field of electrical voltage measurement and is therefore suitable for parallel recording of voltages on a maximum of three voltage channels.
The voltage data logger is used to record e.g. sensor data which can be read out via a voltage output. The measuring range of up to 3000 mV can be extended for sensors with higher voltages up to 10 V via a voltage divider (see optional accessories). If, for example, physical variables such as temperature, pressure and level are to be recorded and compared simultaneously in a system, the corresponding sensors can be connected to the data logger in order to display and document the changes and mutual dependencies of the three variables after the measurement. The voltage data logger can also be used to compare identical sensors at a measuring point. In this way, sensor errors can be directly excluded before permanent installation and measurement. Air pressures before and after filters can also be checked with suitable sensors in order to test the filter function. The data loggers for voltage are therefore suitable for a wide range of applications in industry, maintenance and repair or research and development. T-910329 PCE-VR 10 4250348719355 en ["de","en","it","nl","nl","fr","es","pl","pt","cs","da","sv"] https://www.toolteam.com/en-GB/pce-voltage-data-logger-pce-vr-10-t-910329-4250348719355?dc=GB&cu=EUR 2026-06-04 265.92 United Kingdom GB DE 14