zoom_in
zoom_out
fullscreen
-25%
PCE Ultrasonic flowmeter PCE-TDS 200 SML
Sku: T-1515496
€2,492.68 (excl. legal VAT, excl. Shipping)
€3,319.91 MSRP
In stock,ready for shipping within 24h
Piece
doneMade in Germany
Measuring range ±32 m/s
USB-C interface for data transmission
Optional software for analysing the measured values
Reproducibility ±0.5 % of the measured value
Data memory for 10 million measuring points
Individually adjustable alarm limit values
Optional with ISO or DAkkS calibration certificate
USB-C interface for data transmission
Optional software for analysing the measured values
Reproducibility ±0.5 % of the measured value
Data memory for 10 million measuring points
Individually adjustable alarm limit values
Optional with ISO or DAkkS calibration certificate
Content:
1 Piece
Shipping:
€273.87 Versandservice to United Kingdom
For orders from €1,000.00 order total plus €34.45 Customs MRN registration
Lieferung:
Provider:
Sales and delivery by ToolTeam Köln
Payment methods:
Returns:
Security:
Product data
Manufacturer:
PCE Deutschland GmbH
Condition:
NEW
Sku:
T-1515496
SKU manufacturer:
PCE-TDS 200 SML
GTIN Code (EAN):
4250348732293
Weight:
2,79 Kg
All information relating to products from PCE Deutschland GmbH. Technical and optical modifications of the manufacturer and errors reserved.
This page has been machine-translated, the original german version can be found here, please also note the Translation Disclaimer.
Product description
The ultrasonic flowmeter has a measuring range of ±32 m/s. With an accuracy of ±1.5 % of the mean value for a pipe diameter of DN ≥50, ±3.5 % of the mean value for a pipe diameter of DN <50 and a reproducibility of ±0.5 % of the mean value, the ultrasonic flow meter is a particularly precise measuring device. An installation aid is available for installing the sensors in the ultrasonic flow meter. The installation aid graphically displays the signal quality of the ultrasonic flow meter. It also graphically displays whether the sensors of the ultrasonic flow meter are positioned at the correct distance from each other. To carry out flow measurements with the ultrasonic flowmeter, the flow velocity, volume flow and volume are displayed after entering the pipe and medium specifications. A wide variety of units are available for displaying the measured values on the ultrasonic flow meter. For example: m³, l, gal, igl, mgl, cf, bal, ib and ob.
During a measurement, it is possible to record the measured values using the data logger function on the ultrasonic flowmeter. Start and stop conditions and the storage interval can be set from 1 second to 12 hours for the ultrasonic flowmeter. A memory point in the ultrasonic flowmeter contains all measured variables once. The measured values are stored in the ultrasonic flow meter’s 32 GB built-in memory. This allows 10 million measuring points to be saved on the ultrasonic flowmeter.
The recorded measured values can be read out from the ultrasonic flowmeter using the optional software. The measured values from the ultrasonic flowmeter can be displayed in both tabular and graphical form for analysis. The measured values from the ultrasonic flowmeter can be exported in .csv file format for further processing. Alternatively, a PDF report can be created using the software. For simplified operation, the ultrasonic flowmeter can be set via the software. A live view of the measured values from the ultrasonic flowmeter is also possible with the software.
To determine the amount of heat with the ultrasonic flow meter, two additional thermocouples are required. These are available with the PCE-TDS 200+. The two thermocouples of the ultrasonic flow meter are connected to the flow and return of a pipe system. Based on the temperature difference and the measured flow rate, the ultrasonic flowmeter can determine the amount of heat. If required, the ultrasonic flowmeter can simultaneously calculate and display the costs per heat quantity unit during the measurement. The ultrasonic flowmeter is therefore used, for example, for checking heating systems.
The LC colour display of the ultrasonic flowmeter has a size of 2.8’ and is therefore easy to read. The ultrasonic flowmeter can be optionally equipped with an ISO or DAkkS calibration certificate.
PCE-TDS 200 S SENSOR
Small sensor pair for pipe diameters DN 15 ... 100 / 20 ... 108 mm. Suitable for particularly small pipes. The sensors have particularly small dimensions of 45 x 30 x 30 mm and a temperature resistance of -30 ... 160 °C. Thanks to the magnets on the underside, the sensors can be mounted on ferrous metals. In addition, the sensors can be connected to the ultrasonic flow meter by means of detachable cable ties to the pipe.
PCE-TDS 200 M SENSOR
Medium-sized sensor pair for pipe diameters DN 50 ... 700 / 57 ... 720 mm. Suitable for flow measurement on medium-sized pipes. With the built-in magnets on the sensors for the ultrasonic flow meter, they can be attached to pipes containing iron. Alternatively, the sensors can be attached to the pipe with detachable cable ties. The temperature resistance is between -30 ... 160 °C.
PCE-TDS 200 L SENSOR
Large sensor pair for pipe diameters DN 300 ... 6000. 6000. This sensor pair is therefore suitable for particularly large pipes. The sensors can be attached to the ultrasonic flowmeter with detachable cable ties. Thanks to the built-in magnets, the sensors can be attached to pipes with a ferrous metal. The sensors measure 91 x 52 x 44 mm.
Power supply
1 x ultrasonic flowmeter PCE-TDS 200 SML
1 x flow sensors PCE-TDS 200 S SENSOR (pair)
1 x flow sensors PCE-TDS 200 M SENSOR (pair)
1 x flow sensors PCE- TDS 200 L SENSOR (pair)
2 x 5 m connection cable
2 x detachable cable ties
1 x power supply
1 x USB-C cable
1 x ultrasonic contact gel
1 x PCE measuring tape
1 x plastic case
1 x operating instructions
During a measurement, it is possible to record the measured values using the data logger function on the ultrasonic flowmeter. Start and stop conditions and the storage interval can be set from 1 second to 12 hours for the ultrasonic flowmeter. A memory point in the ultrasonic flowmeter contains all measured variables once. The measured values are stored in the ultrasonic flow meter’s 32 GB built-in memory. This allows 10 million measuring points to be saved on the ultrasonic flowmeter.
The recorded measured values can be read out from the ultrasonic flowmeter using the optional software. The measured values from the ultrasonic flowmeter can be displayed in both tabular and graphical form for analysis. The measured values from the ultrasonic flowmeter can be exported in .csv file format for further processing. Alternatively, a PDF report can be created using the software. For simplified operation, the ultrasonic flowmeter can be set via the software. A live view of the measured values from the ultrasonic flowmeter is also possible with the software.
To determine the amount of heat with the ultrasonic flow meter, two additional thermocouples are required. These are available with the PCE-TDS 200+. The two thermocouples of the ultrasonic flow meter are connected to the flow and return of a pipe system. Based on the temperature difference and the measured flow rate, the ultrasonic flowmeter can determine the amount of heat. If required, the ultrasonic flowmeter can simultaneously calculate and display the costs per heat quantity unit during the measurement. The ultrasonic flowmeter is therefore used, for example, for checking heating systems.
The LC colour display of the ultrasonic flowmeter has a size of 2.8’ and is therefore easy to read. The ultrasonic flowmeter can be optionally equipped with an ISO or DAkkS calibration certificate.
PCE-TDS 200 S SENSOR
Small sensor pair for pipe diameters DN 15 ... 100 / 20 ... 108 mm. Suitable for particularly small pipes. The sensors have particularly small dimensions of 45 x 30 x 30 mm and a temperature resistance of -30 ... 160 °C. Thanks to the magnets on the underside, the sensors can be mounted on ferrous metals. In addition, the sensors can be connected to the ultrasonic flow meter by means of detachable cable ties to the pipe.
PCE-TDS 200 M SENSOR
Medium-sized sensor pair for pipe diameters DN 50 ... 700 / 57 ... 720 mm. Suitable for flow measurement on medium-sized pipes. With the built-in magnets on the sensors for the ultrasonic flow meter, they can be attached to pipes containing iron. Alternatively, the sensors can be attached to the pipe with detachable cable ties. The temperature resistance is between -30 ... 160 °C.
PCE-TDS 200 L SENSOR
Large sensor pair for pipe diameters DN 300 ... 6000. 6000. This sensor pair is therefore suitable for particularly large pipes. The sensors can be attached to the ultrasonic flowmeter with detachable cable ties. Thanks to the built-in magnets, the sensors can be attached to pipes with a ferrous metal. The sensors measure 91 x 52 x 44 mm.
Power supply
1 x ultrasonic flowmeter PCE-TDS 200 SML
1 x flow sensors PCE-TDS 200 S SENSOR (pair)
1 x flow sensors PCE-TDS 200 M SENSOR (pair)
1 x flow sensors PCE- TDS 200 L SENSOR (pair)
2 x 5 m connection cable
2 x detachable cable ties
1 x power supply
1 x USB-C cable
1 x ultrasonic contact gel
1 x PCE measuring tape
1 x plastic case
1 x operating instructions
Related results
PCE Instruments
PCE
PCE-TDS 200 SML
PCE TDS 200 SML
PCE Instruments
PCE-TDS 200 SML
PCE Instruments PCE-TDS 200 SML
flow meter
flow meter
flow meter for heating systems
heating engineer
flow meter
HVAC meter
HVAC meter
ultrasonic flow meter
ultrasonic flow meter
ultrasonic flow meter
ultrasonic flow meter
portable ultrasonic flow meter
SHK meter
Complete catalogs
The offer is aimed exclusively at business customers, companies, public institutions, tradesmen and freelancers. All prices in catalogues are exclusive of VAT, shipping costs and surcharges if applicable.
The manufacturer is exclusively responsible for the content, price and article details of the products and offers presented in the catalogues. Subject to technical and optical changes by the manufacturer and errors excepted.
The manufacturer is exclusively responsible for the content, price and article details of the products and offers presented in the catalogues. Subject to technical and optical changes by the manufacturer and errors excepted.
Matching catalog
Commercial customer offer**
Product suggestions
-24%
sound level meter PCE-SLT-TRM
PCE-SLT-TRM
€269.71
€355.88 MSRP
-25%
ATP measuring device PCE-ATP 1-KIT for surfaces
PCE-ATP 1-KIT
€1,253.82
€1,669.91 MSRP
-25%
Kraftmessgerät
PCE-DFG 50K XF
€1,310.13
€1,744.92 MSRP
-25%
vehicle measuring device PCE-CT 80HP-FN3
PCE-CT 80HP-FN3
€747.02
€994.92 MSRP
-24%
Durometer PCE-DX-AS
PCE-DX-AS
€108.28
€142.90 MSRP
-24%
Borescope PCE-VE 200SV1
PCE-VE 200SV1
€363.69
€479.92 MSRP
-24%
Refractometer PCE-0100 Salinity
PCE-0100
€64.92
€84.92 MSRP
-24%
Pressure gauge PCE-PME 100
PCE-PME 100
€128.74
€169.91 MSRP
-25%
1 + 3-phase power analyzer PCE-360 | RS-232 interface | PC cable | software | 512 K data logger
PCE-360
€1,257.56
€1,674.92 MSRP
-25%
display / built-in display PCE-BPD-U-46A
PCE-BPD-U-46A
€568.31
€756.89 MSRP
-25%
Hydraulic lifting table - industrial scale PCE-HLTS 500
PCE-HLTS 500
€3,266.01
€4,349.91 MSRP
-25%
Feuchtebestimmerwaage
PCE-UX 3011HQ
€2,995.80
€3,990.00 MSRP
-25%
Defectoscope PCE-FD 20
PCE-FD 20
€3,452.98
€4,598.90 MSRP
-25%
PCE-EMD 5 hygrometer 0.0..99.9% RH|0...50 °C|connection of up to four external sensors|anal. 4..20mA
PCE-EMD 5
€598.32
€796.89 MSRP
-25%
Borescope PCE-VE 380N
PCE-VE 380N
€1,614.20
€2,149.91 MSRP
No Review yet
Description: No Review yet
Written by: No Review
Rating: 5 out of 5
5 stars, based on 1
reviews
PCE Ultrasonic flowmeter PCE-TDS 200 SML
PCE Instruments
PCE
PCE-TDS 200 SML
PCE TDS 200 SML
PCE Instruments
PCE-TDS 200 SML
PCE Instruments PCE-TDS 200 SML
flow meter
flow meter
flow meter for heating systems
heating engineer
flow meter
HVAC meter
HVAC meter
ultrasonic flow meter
ultrasonic flow meter
ultrasonic flow meter
ultrasonic flow meter
portable ultrasonic flow meter
SHK meter
The ultrasonic flowmeter has a measuring range of ±32 m/s. With an accuracy of ±1.5 % of the mean value for a pipe diameter of DN ≥50, ±3.5 % of the mean value for a pipe diameter of DN <50 and a reproducibility of ±0.5 % of the mean value, the ultrasonic flow meter is a particularly precise measuring device. An installation aid is available for installing the sensors in the ultrasonic flow meter. The installation aid graphically displays the signal quality of the ultrasonic flow meter. It also graphically displays whether the sensors of the ultrasonic flow meter are positioned at the correct distance from each other. To carry out flow measurements with the ultrasonic flowmeter, the flow velocity, volume flow and volume are displayed after entering the pipe and medium specifications. A wide variety of units are available for displaying the measured values on the ultrasonic flow meter. For example: m³, l, gal, igl, mgl, cf, bal, ib and ob.
During a measurement, it is possible to record the measured values using the data logger function on the ultrasonic flowmeter. Start and stop conditions and the storage interval can be set from 1 second to 12 hours for the ultrasonic flowmeter. A memory point in the ultrasonic flowmeter contains all measured variables once. The measured values are stored in the ultrasonic flow meter’s 32 GB built-in memory. This allows 10 million measuring points to be saved on the ultrasonic flowmeter.
The recorded measured values can be read out from the ultrasonic flowmeter using the optional software. The measured values from the ultrasonic flowmeter can be displayed in both tabular and graphical form for analysis. The measured values from the ultrasonic flowmeter can be exported in .csv file format for further processing. Alternatively, a PDF report can be created using the software. For simplified operation, the ultrasonic flowmeter can be set via the software. A live view of the measured values from the ultrasonic flowmeter is also possible with the software.
To determine the amount of heat with the ultrasonic flow meter, two additional thermocouples are required. These are available with the PCE-TDS 200+. The two thermocouples of the ultrasonic flow meter are connected to the flow and return of a pipe system. Based on the temperature difference and the measured flow rate, the ultrasonic flowmeter can determine the amount of heat. If required, the ultrasonic flowmeter can simultaneously calculate and display the costs per heat quantity unit during the measurement. The ultrasonic flowmeter is therefore used, for example, for checking heating systems.
The LC colour display of the ultrasonic flowmeter has a size of 2.8’ and is therefore easy to read. The ultrasonic flowmeter can be optionally equipped with an ISO or DAkkS calibration certificate.
PCE-TDS 200 S SENSOR
Small sensor pair for pipe diameters DN 15 ... 100 / 20 ... 108 mm. Suitable for particularly small pipes. The sensors have particularly small dimensions of 45 x 30 x 30 mm and a temperature resistance of -30 ... 160 °C. Thanks to the magnets on the underside, the sensors can be mounted on ferrous metals. In addition, the sensors can be connected to the ultrasonic flow meter by means of detachable cable ties to the pipe.
PCE-TDS 200 M SENSOR
Medium-sized sensor pair for pipe diameters DN 50 ... 700 / 57 ... 720 mm. Suitable for flow measurement on medium-sized pipes. With the built-in magnets on the sensors for the ultrasonic flow meter, they can be attached to pipes containing iron. Alternatively, the sensors can be attached to the pipe with detachable cable ties. The temperature resistance is between -30 ... 160 °C.
PCE-TDS 200 L SENSOR
Large sensor pair for pipe diameters DN 300 ... 6000. 6000. This sensor pair is therefore suitable for particularly large pipes. The sensors can be attached to the ultrasonic flowmeter with detachable cable ties. Thanks to the built-in magnets, the sensors can be attached to pipes with a ferrous metal. The sensors measure 91 x 52 x 44 mm.
Power supply
1 x ultrasonic flowmeter PCE-TDS 200 SML
1 x flow sensors PCE-TDS 200 S SENSOR (pair)
1 x flow sensors PCE-TDS 200 M SENSOR (pair)
1 x flow sensors PCE- TDS 200 L SENSOR (pair)
2 x 5 m connection cable
2 x detachable cable ties
1 x power supply
1 x USB-C cable
1 x ultrasonic contact gel
1 x PCE measuring tape
1 x plastic case
1 x operating instructions T-1515496 PCE-TDS 200 SML 4250348732293 en ["de","en","it","nl","nl","fr","es","pl","pt","cs","da","sv"] https://www.toolteam.com/en-GB/pce-ultrasonic-flowmeter-pce-tds-200-sml-t-1515496-4250348732293?dc=GB&cu=EUR 2026-07-09 2492.68 United Kingdom GB DE 14
During a measurement, it is possible to record the measured values using the data logger function on the ultrasonic flowmeter. Start and stop conditions and the storage interval can be set from 1 second to 12 hours for the ultrasonic flowmeter. A memory point in the ultrasonic flowmeter contains all measured variables once. The measured values are stored in the ultrasonic flow meter’s 32 GB built-in memory. This allows 10 million measuring points to be saved on the ultrasonic flowmeter.
The recorded measured values can be read out from the ultrasonic flowmeter using the optional software. The measured values from the ultrasonic flowmeter can be displayed in both tabular and graphical form for analysis. The measured values from the ultrasonic flowmeter can be exported in .csv file format for further processing. Alternatively, a PDF report can be created using the software. For simplified operation, the ultrasonic flowmeter can be set via the software. A live view of the measured values from the ultrasonic flowmeter is also possible with the software.
To determine the amount of heat with the ultrasonic flow meter, two additional thermocouples are required. These are available with the PCE-TDS 200+. The two thermocouples of the ultrasonic flow meter are connected to the flow and return of a pipe system. Based on the temperature difference and the measured flow rate, the ultrasonic flowmeter can determine the amount of heat. If required, the ultrasonic flowmeter can simultaneously calculate and display the costs per heat quantity unit during the measurement. The ultrasonic flowmeter is therefore used, for example, for checking heating systems.
The LC colour display of the ultrasonic flowmeter has a size of 2.8’ and is therefore easy to read. The ultrasonic flowmeter can be optionally equipped with an ISO or DAkkS calibration certificate.
PCE-TDS 200 S SENSOR
Small sensor pair for pipe diameters DN 15 ... 100 / 20 ... 108 mm. Suitable for particularly small pipes. The sensors have particularly small dimensions of 45 x 30 x 30 mm and a temperature resistance of -30 ... 160 °C. Thanks to the magnets on the underside, the sensors can be mounted on ferrous metals. In addition, the sensors can be connected to the ultrasonic flow meter by means of detachable cable ties to the pipe.
PCE-TDS 200 M SENSOR
Medium-sized sensor pair for pipe diameters DN 50 ... 700 / 57 ... 720 mm. Suitable for flow measurement on medium-sized pipes. With the built-in magnets on the sensors for the ultrasonic flow meter, they can be attached to pipes containing iron. Alternatively, the sensors can be attached to the pipe with detachable cable ties. The temperature resistance is between -30 ... 160 °C.
PCE-TDS 200 L SENSOR
Large sensor pair for pipe diameters DN 300 ... 6000. 6000. This sensor pair is therefore suitable for particularly large pipes. The sensors can be attached to the ultrasonic flowmeter with detachable cable ties. Thanks to the built-in magnets, the sensors can be attached to pipes with a ferrous metal. The sensors measure 91 x 52 x 44 mm.
Power supply
1 x ultrasonic flowmeter PCE-TDS 200 SML
1 x flow sensors PCE-TDS 200 S SENSOR (pair)
1 x flow sensors PCE-TDS 200 M SENSOR (pair)
1 x flow sensors PCE- TDS 200 L SENSOR (pair)
2 x 5 m connection cable
2 x detachable cable ties
1 x power supply
1 x USB-C cable
1 x ultrasonic contact gel
1 x PCE measuring tape
1 x plastic case
1 x operating instructions T-1515496 PCE-TDS 200 SML 4250348732293 en ["de","en","it","nl","nl","fr","es","pl","pt","cs","da","sv"] https://www.toolteam.com/en-GB/pce-ultrasonic-flowmeter-pce-tds-200-sml-t-1515496-4250348732293?dc=GB&cu=EUR 2026-07-09 2492.68 United Kingdom GB DE 14