PCE Ultrasonic Flow Meter PCE-TDS 200 MR Thumbnail
PCE Ultrasonic Flow Meter PCE-TDS 200 MR Thumbnail
PCE Ultrasonic Flow Meter PCE-TDS 200 MR Thumbnail
PCE Ultrasonic Flow Meter PCE-TDS 200 MR Thumbnail
PCE Ultrasonic Flow Meter PCE-TDS 200 MR Thumbnail

 
PCE Ultrasonic Flow Meter PCE-TDS 200 MR
zoom_in
zoom_out
fullscreen
PCE Instruments brand logo
-21%

PCE Ultrasonic Flow Meter PCE-TDS 200 MR

Sku: T-910640
€2,043.07 (excl. legal VAT, excl. Shipping)
€2,599.91 MSRP
In stock,
ready for shipping within 24h
Piece
 
Ask a question
doneMade in Germany
Measuring range ±32 m/s
USB-C interface for data transfer
Optional software for analysing the measured values
Reproducibility ±0.5 % of measured value
Heat quantity measurement
Data memory for 10 million measuring points
individually adjustable alarm limits
optionally with ISO or DAkkS calibration certificate
Content:
1 Piece
Shipping:
€199.92 Versandservice to United Kingdom
For orders from €1,000.00 order total plus €34.45 Customs MRN registration
Lieferung:
Between 13. Sep and 18. Sep with today receipt of payment
If you order in the next 5 hours and 48 Minutes with Versandservice

Provider:
Sales and delivery by ToolTeam Köln
Payment methods:
Returns:
Security:

Product data

Manufacturer:
PCE Deutschland GmbH
Condition:
NEW
Sku:
T-910640
SKU manufacturer:
PCE-TDS 200 MR
GTIN Code (EAN):
4250348731395
Weight:
2,79 Kg
All information relating to products from PCE Deutschland GmbH. Technical and optical modifications of the manufacturer and errors reserved. This page has been machine-translated, the original german version can be found here, please also note the Translation Disclaimer.

Product description

The flow meter has a measuring range of ± 32 m/s. With an accuracy of ± 1.5 % v. Mw. With a pipe diameter of DN ?50, ± 3.5 % v. Mw. With a pipe diameter of DN <50 and a reproducibility of ± 0.5 % v. Mw. the flow meter is a particularly precise measuring device. Installation aid is available for installing the sensors in the flow meter. With the installation aid, the signal quality from the flow meter is shown graphically. In addition, it is shown graphically whether the sensors from the flow meter are positioned at the right distance to each other. In order to carry out flow measurement with the flow meter, the river speed, the volume flow and the volume are displayed after entering the pipe and medium specifications. When displaying the measured values, the various units are available for the flow meter. For example: M³, L, Gal, Igl, MGL, CF, BAL, IB and OB.

During a measurement, it is possible to record the measured values ??via the data logger function in the case of ultrasound flow meter. Starting and stop conditions and the memory interval of 1 second to 12 hours can be set for the flow meter. A storage point contains all measurement sizes once with the flow meter. The measured values ??are saved on the 32 GB large -built memory with the ultrasound flow meter. 10 million measuring points can be saved on the ultrasound flow meter.

With the optional software, the recorded measured values ??from the flow meter can be read out. For the analysis, the measured values ??from the flow meter can be displayed tabularly and graphically. For further processing of the measured values ??from the flow meter, these can be exported in the .cSV file format. Alternatively, a PDF Report can be created via the software. For simplified operation, the flow meter can be set via the software. A live view of the measured values ??from the ultrasound flow meter is also possible with the software.

In order to determine the amount of heat with the flow meter, two thermo elements are also required. These are available at the PCE-TDS 200+. The two thermo elements from the flow meter are connected to the forward and return of a pipe system. Based on the temperature difference and the measured flow rate, the flow meter can determine the amount of heat. If necessary, the flow meter can simultaneously calculate and display the costs during the measurement. This means that the flow meter is used, for example, when checking the heating system.

The LC color display from the ultrasound flow meter has a size of 2.8 ”and is therefore easy to read. Optionally, the flow meter can be equipped with an ISO or DAKKS calibration certificate.

PCE-TDS 200 MR sensor
Separate on Rail sensors for the pipe sizes DN 50… 700/57… 720 mm. The temperature resistance is between -30… 160 ° C. The sensor on the respective rail is located on a rail and can therefore be positioned appropriately. There are magnets below the rails that enable themselves to hold onto pipes with an iron -containing metal.

Complete catalogs

The offer is aimed exclusively at business customers, companies, public institutions, tradesmen and freelancers. All prices in catalogues are exclusive of VAT, shipping costs and surcharges if applicable.
The manufacturer is exclusively responsible for the content, price and article details of the products and offers presented in the catalogues. Subject to technical and optical changes by the manufacturer and errors excepted.