zoom_in
zoom_out
fullscreen
-25%
PCE ultrasonic flow meter PCE-TDS 75 for permanent installation
Sku: T-910263
€1,220.00 (excl. legal VAT, excl. Shipping)
€1,624.92 MSRP
In stock,ready for shipping within 48h
Piece
Content:
1 Piece
Shipping:
€199.92 Versandservice to United Kingdom
For orders from €1,000.00 order total plus €34.45 Customs MRN registration
Lieferung:
Provider:
Sales and delivery by ToolTeam Köln
Payment methods:
Returns:
Security:
Product data
Manufacturer:
PCE Deutschland GmbH
Condition:
NEW
Sku:
T-910263
SKU manufacturer:
PCE-TDS 75
GTIN Code (EAN):
4250348722560
Weight:
2,59 Kg
All information relating to products from PCE Deutschland GmbH. Technical and optical modifications of the manufacturer and errors reserved.
This page has been machine-translated, the original german version can be found here, please also note the Translation Disclaimer.
Product description
A stationary ultrasonic flowmeter is a device for continuous monitoring of the flow rate of liquids in pipelines. One of the advantages of the measuring principle is that the sensors of stationary ultrasonic flow meters can be easily mounted on the outside of the pipeline. For installation, the pipes do not have to be cut open or drilled into. This allows the measuring system to be installed without draining the pipelines. Due to the non-contact measuring principle of stationary ultrasonic flow meters, they can also be used in areas with high hygiene requirements - for example in the food industry. Depending on the conditions on site, our stationary flow meter can measure either with the reflection method or with the direct method.
For reflection measurement, also known as the V-method, both sensors are mounted side by side on the same side of the pipeline parallel to the flow direction. One of the sensors emits ultrasonic waves, and the other sensor receives the waves reflected from the opposite side of the pipe. In contrast, for direct measurement, also called the Z method, the sensors are mounted on opposite sides of the pipe. Our stationary ultrasonic flowmeter offers many setting and query options in the device menu. All necessary settings can be made directly at the installation site via keyboard entries on the device.
The membrane keypad also has a numeric keypad for quick entry of numeric values. After connecting the device, the data of the measuring point such as diameter, thickness and material of the pipe must first be entered in menu M10 Pipe settings” so that the measured values can be converted correctly. In menu M14 ”INSTL Spacing” the calculated mounting distance for the sensors can be read. After mounting the sensors, it can then be read in another menu whether the strength and quality of the signals are sufficient for reliable measurements. If not, the arrangement of the sensors can be adjusted or, if necessary, another measuring point can be selected.
For reflection measurement, also known as the V-method, both sensors are mounted side by side on the same side of the pipeline parallel to the flow direction. One of the sensors emits ultrasonic waves, and the other sensor receives the waves reflected from the opposite side of the pipe. In contrast, for direct measurement, also called the Z method, the sensors are mounted on opposite sides of the pipe. Our stationary ultrasonic flowmeter offers many setting and query options in the device menu. All necessary settings can be made directly at the installation site via keyboard entries on the device.
The membrane keypad also has a numeric keypad for quick entry of numeric values. After connecting the device, the data of the measuring point such as diameter, thickness and material of the pipe must first be entered in menu M10 Pipe settings” so that the measured values can be converted correctly. In menu M14 ”INSTL Spacing” the calculated mounting distance for the sensors can be read. After mounting the sensors, it can then be read in another menu whether the strength and quality of the signals are sufficient for reliable measurements. If not, the arrangement of the sensors can be adjusted or, if necessary, another measuring point can be selected.
Related results
pc
pce instruments
measurement technology
control technology
weighing technology
laboratory technology
development
production
calibration
pc
pce instruments
measurement technology
control technology
weighing technology
laboratory technology
development
production
calibration
pce
pce instruments
weighing technology
platform scales
shipping scales
pallet scales
inventory scales
platform scales
industrial scales
multifunctional scales
compact scales
weighing platform
pce
pce instruments
measurement technology
machines
systems
vibration measurement
vibration measuring device
vibration measuring device
accelerometer
stethoscope
data logger
Complete catalogs
The offer is aimed exclusively at business customers, companies, public institutions, tradesmen and freelancers. All prices in catalogues are exclusive of VAT, shipping costs and surcharges if applicable.
The manufacturer is exclusively responsible for the content, price and article details of the products and offers presented in the catalogues. Subject to technical and optical changes by the manufacturer and errors excepted.
The manufacturer is exclusively responsible for the content, price and article details of the products and offers presented in the catalogues. Subject to technical and optical changes by the manufacturer and errors excepted.
Matching catalog
Commercial customer offer**
Product suggestions
-24%
material test bench PCE-FTS50
PCE-FTS50
€439.45
€579.92 MSRP
-25%
Borescope PCE-VE 380N
PCE-VE 380N
€1,614.20
€2,149.91 MSRP
-24%
4-channel thermometer with data logger PCE-T 394
PCE-T 394
€122.69
€161.89 MSRP
-25%
lifting table scale / industrial scale PCE-HLTS 2T
PCE-HLTS 2T
€3,566.34
€4,749.91 MSRP
-24%
Radiation Meter PCE-EM 29
PCE-EM 29
€201.50
€265.88 MSRP
-25%
ATP measuring device PCE-ATP 1-KIT3 for surfaces and water
PCE-ATP 1-KIT3
€1,441.51
€1,919.91 MSRP
-25%
Kraftmessgerät
PCE-DFG 50K XF
€1,310.13
€1,744.92 MSRP
-25%
PCE-900 Leeb hardness tester for metals |200 ... 900 HL|± 0.8% at HLD=900 |HL |HRC|HRB|HB|HV|HSD
PCE-900
€600.59
€799.91 MSRP
-24%
Borescope PCE-VE 200SV1
PCE-VE 200SV1
€363.69
€479.92 MSRP
-25%
thickness gauge PCE-CT 80HP-F5N3
PCE-CT 80HP-F5N3
€750.75
€999.91 MSRP
-24%
Borescope PCE-VE 200-S
PCE-VE 200-S
€431.89
€569.91 MSRP
-24%
Durometer PCE-DX-AS
PCE-DX-AS
€108.28
€142.90 MSRP
-24%
building moisture meter PCE-PMI 4
PCE-PMI 4
€378.82
€499.91 MSRP
-24%
Refractometer PCE-0100 Salinity
PCE-0100
€64.92
€84.92 MSRP
-24%
mold measuring device PCE-PMI 1BT
PCE-PMI 1BT
€89.41
€116.89 MSRP
No Review yet
Description: No Review yet
Written by: No Review
Rating: 5 out of 5
5 stars, based on 1
reviews
PCE ultrasonic flow meter PCE-TDS 75 for permanent installation
pc
pce instruments
measurement technology
control technology
weighing technology
laboratory technology
development
production
calibration
pc
pce instruments
measurement technology
control technology
weighing technology
laboratory technology
development
production
calibration
pce
pce instruments
weighing technology
platform scales
shipping scales
pallet scales
inventory scales
platform scales
industrial scales
multifunctional scales
compact scales
weighing platform
pce
pce instruments
measurement technology
machines
systems
vibration measurement
vibration measuring device
vibration measuring device
accelerometer
stethoscope
data logger
A stationary ultrasonic flowmeter is a device for continuous monitoring of the flow rate of liquids in pipelines. One of the advantages of the measuring principle is that the sensors of stationary ultrasonic flow meters can be easily mounted on the outside of the pipeline. For installation, the pipes do not have to be cut open or drilled into. This allows the measuring system to be installed without draining the pipelines. Due to the non-contact measuring principle of stationary ultrasonic flow meters, they can also be used in areas with high hygiene requirements - for example in the food industry. Depending on the conditions on site, our stationary flow meter can measure either with the reflection method or with the direct method.
For reflection measurement, also known as the V-method, both sensors are mounted side by side on the same side of the pipeline parallel to the flow direction. One of the sensors emits ultrasonic waves, and the other sensor receives the waves reflected from the opposite side of the pipe. In contrast, for direct measurement, also called the Z method, the sensors are mounted on opposite sides of the pipe. Our stationary ultrasonic flowmeter offers many setting and query options in the device menu. All necessary settings can be made directly at the installation site via keyboard entries on the device.
The membrane keypad also has a numeric keypad for quick entry of numeric values. After connecting the device, the data of the measuring point such as diameter, thickness and material of the pipe must first be entered in menu M10 Pipe settings” so that the measured values can be converted correctly. In menu M14 ”INSTL Spacing” the calculated mounting distance for the sensors can be read. After mounting the sensors, it can then be read in another menu whether the strength and quality of the signals are sufficient for reliable measurements. If not, the arrangement of the sensors can be adjusted or, if necessary, another measuring point can be selected. T-910263 PCE-TDS 75 4250348722560 en ["de","en","it","nl","nl","fr","es","pl","pt","cs","da","sv"] https://www.toolteam.com/en-GB/pce-ultrasonic-flow-meter-pce-tds-75-for-permanent-installation-t-910263-4250348722560?dc=GB&cu=EUR 2026-07-13 1220 United Kingdom GB DE 14
For reflection measurement, also known as the V-method, both sensors are mounted side by side on the same side of the pipeline parallel to the flow direction. One of the sensors emits ultrasonic waves, and the other sensor receives the waves reflected from the opposite side of the pipe. In contrast, for direct measurement, also called the Z method, the sensors are mounted on opposite sides of the pipe. Our stationary ultrasonic flowmeter offers many setting and query options in the device menu. All necessary settings can be made directly at the installation site via keyboard entries on the device.
The membrane keypad also has a numeric keypad for quick entry of numeric values. After connecting the device, the data of the measuring point such as diameter, thickness and material of the pipe must first be entered in menu M10 Pipe settings” so that the measured values can be converted correctly. In menu M14 ”INSTL Spacing” the calculated mounting distance for the sensors can be read. After mounting the sensors, it can then be read in another menu whether the strength and quality of the signals are sufficient for reliable measurements. If not, the arrangement of the sensors can be adjusted or, if necessary, another measuring point can be selected. T-910263 PCE-TDS 75 4250348722560 en ["de","en","it","nl","nl","fr","es","pl","pt","cs","da","sv"] https://www.toolteam.com/en-GB/pce-ultrasonic-flow-meter-pce-tds-75-for-permanent-installation-t-910263-4250348722560?dc=GB&cu=EUR 2026-07-13 1220 United Kingdom GB DE 14