zoom_in
zoom_out
fullscreen
-24%
PCE occupational health and safety measuring device PCE-HLD 10
Sku: T-910025
€270.46 (excl. legal VAT, excl. Shipping)
€356.89 MSRP
In stock,ready for shipping within 24h
Piece
Content:
1 Piece
Shipping:
€73.87 Versandservice to United Kingdom
Lieferung:
Provider:
Sales and delivery by ToolTeam Köln
Payment methods:
Returns:
Security:
Product data
Manufacturer:
PCE Deutschland GmbH
Condition:
NEW
Sku:
T-910025
SKU manufacturer:
PCE-HLD 10
GTIN Code (EAN):
4250348727633
Weight:
0,99 Kg
All information relating to products from PCE Deutschland GmbH. Technical and optical modifications of the manufacturer and errors reserved.
This page has been machine-translated, the original german version can be found here, please also note the Translation Disclaimer.
Product description
It is also excellent for detecting leaks due to its physical properties. With its hydrogen-selective sensor, the industrial safety measuring device can detect the smallest leaks with a very low leak rate. Even containers or lines that do not contain hydrogen can be tested for leaks with the industrial safety meter if they are filled with test gas containing hydrogen and then scanned for leaks.
Forming gas, which is already commercially available for other engineering purposes and contains five percent hydrogen and ninety-five percent nitrogen, is well suited for leak testing. This industrial safety meter automatically detects the current hydrogen concentration of the environment each time it is turned on, and then evaluates changes only relative to that concentration. The reset button does the same during leak detection. If the leak location cannot be clearly identified even though all indicator LEDs are already lit, the reset function can be used to set the current hydrogen concentration as the base value and thus better narrow down the location of the leak.
Afterwards, the industrial safety measuring instrument can be reset to low initial values in an unstressed environment. Regardless of the output concentration level, one of three different sensitivity levels can be set on the industrial safety measuring device by pressing a button. The selected sensitivity is indicated by a labeled LED lighting up. The H” stands for high, the ”M” for medium and the ”L” for low. The hydrogen content in normal ambient air is 0.5 ppm. The sensitive device already detects concentrations of less than 5 ppm, i.e. 0.0005 percent. The sensor is located at the head of a semi-rigid 40-centimeter-long hose so that it can be easily guided to the component to be tested. To detect leaks, the sensor is moved slowly as close as possible along the areas to be tested.
Forming gas, which is already commercially available for other engineering purposes and contains five percent hydrogen and ninety-five percent nitrogen, is well suited for leak testing. This industrial safety meter automatically detects the current hydrogen concentration of the environment each time it is turned on, and then evaluates changes only relative to that concentration. The reset button does the same during leak detection. If the leak location cannot be clearly identified even though all indicator LEDs are already lit, the reset function can be used to set the current hydrogen concentration as the base value and thus better narrow down the location of the leak.
Afterwards, the industrial safety measuring instrument can be reset to low initial values in an unstressed environment. Regardless of the output concentration level, one of three different sensitivity levels can be set on the industrial safety measuring device by pressing a button. The selected sensitivity is indicated by a labeled LED lighting up. The H” stands for high, the ”M” for medium and the ”L” for low. The hydrogen content in normal ambient air is 0.5 ppm. The sensitive device already detects concentrations of less than 5 ppm, i.e. 0.0005 percent. The sensor is located at the head of a semi-rigid 40-centimeter-long hose so that it can be easily guided to the component to be tested. To detect leaks, the sensor is moved slowly as close as possible along the areas to be tested.
Related results
pc
pce instruments
measurement technology
control technology
weighing technology
laboratory technology
development
production
calibration
pc
pce instruments
measurement technology
control technology
weighing technology
laboratory technology
development
production
calibration
pce
pce instruments
weighing technology
platform scales
shipping scales
pallet scales
inventory scales
platform scales
industrial scales
multifunctional scales
compact scales
weighing platform
pce
pce instruments
measurement technology
machines
systems
vibration measurement
vibration measuring device
vibration measuring device
accelerometer
stethoscope
data logger
Complete catalogs
The offer is aimed exclusively at business customers, companies, public institutions, tradesmen and freelancers. All prices in catalogues are exclusive of VAT, shipping costs and surcharges if applicable.
The manufacturer is exclusively responsible for the content, price and article details of the products and offers presented in the catalogues. Subject to technical and optical changes by the manufacturer and errors excepted.
The manufacturer is exclusively responsible for the content, price and article details of the products and offers presented in the catalogues. Subject to technical and optical changes by the manufacturer and errors excepted.
Product suggestions
-25%
Hydraulic lifting table - industrial scale PCE-HLTS 500
PCE-HLTS 500
€3,266.01
€4,349.91 MSRP
-24%
Temperature / humidity transmitter PCE-P18L
PCE-P18L
€106.22
€138.90 MSRP
-24%
Installation aid PCE-HVAC 10
PCE-HVAC 10
€189.37
€249.91 MSRP
-24%
material test bench PCE-FTS50
PCE-FTS50
€439.45
€579.92 MSRP
-25%
Feuchtebestimmerwaage
PCE-UX 3011HQ
€2,995.80
€3,990.00 MSRP
-24%
Durometer PCE-DX-AS
PCE-DX-AS
€108.28
€142.90 MSRP
-24%
Radiation Meter PCE-EM 29
PCE-EM 29
€201.50
€265.88 MSRP
-24%
Radon Monitor
PCE-RD 75
€143.91
€189.91 MSRP
-24%
Borescope PCE-VE 200-S
PCE-VE 200-S
€431.89
€569.91 MSRP
-24%
building moisture meter PCE-PMI 4
PCE-PMI 4
€378.82
€499.91 MSRP
-25%
Thickness Gauge PCE-CT 80HP-FN0D5
PCE-CT 80HP-FN0D5
€747.02
€994.92 MSRP
-24%
PCE-DPG 100 Pressure Gauge Air Pressure & Water Pressure | PEAK function | 2.5? display | Response time <50 ms
PCE-DPG 100
€253.78
€334.92 MSRP
-24%
mold measuring device PCE-PMI 1BT
PCE-PMI 1BT
€89.41
€116.89 MSRP
-25%
PCE-EMD 5 hygrometer 0.0..99.9% RH|0...50 °C|connection of up to four external sensors|anal. 4..20mA
PCE-EMD 5
€598.32
€796.89 MSRP
-25%
display / built-in display PCE-BPD-U-46A
PCE-BPD-U-46A
€568.31
€756.89 MSRP
No Review yet
Description: No Review yet
Written by: No Review
Rating: 5 out of 5
5 stars, based on 1
reviews
PCE occupational health and safety measuring device PCE-HLD 10
pc
pce instruments
measurement technology
control technology
weighing technology
laboratory technology
development
production
calibration
pc
pce instruments
measurement technology
control technology
weighing technology
laboratory technology
development
production
calibration
pce
pce instruments
weighing technology
platform scales
shipping scales
pallet scales
inventory scales
platform scales
industrial scales
multifunctional scales
compact scales
weighing platform
pce
pce instruments
measurement technology
machines
systems
vibration measurement
vibration measuring device
vibration measuring device
accelerometer
stethoscope
data logger
It is also excellent for detecting leaks due to its physical properties. With its hydrogen-selective sensor, the industrial safety measuring device can detect the smallest leaks with a very low leak rate. Even containers or lines that do not contain hydrogen can be tested for leaks with the industrial safety meter if they are filled with test gas containing hydrogen and then scanned for leaks.
Forming gas, which is already commercially available for other engineering purposes and contains five percent hydrogen and ninety-five percent nitrogen, is well suited for leak testing. This industrial safety meter automatically detects the current hydrogen concentration of the environment each time it is turned on, and then evaluates changes only relative to that concentration. The reset button does the same during leak detection. If the leak location cannot be clearly identified even though all indicator LEDs are already lit, the reset function can be used to set the current hydrogen concentration as the base value and thus better narrow down the location of the leak.
Afterwards, the industrial safety measuring instrument can be reset to low initial values in an unstressed environment. Regardless of the output concentration level, one of three different sensitivity levels can be set on the industrial safety measuring device by pressing a button. The selected sensitivity is indicated by a labeled LED lighting up. The H” stands for high, the ”M” for medium and the ”L” for low. The hydrogen content in normal ambient air is 0.5 ppm. The sensitive device already detects concentrations of less than 5 ppm, i.e. 0.0005 percent. The sensor is located at the head of a semi-rigid 40-centimeter-long hose so that it can be easily guided to the component to be tested. To detect leaks, the sensor is moved slowly as close as possible along the areas to be tested. T-910025 PCE-HLD 10 4250348727633 en ["de","en","it","nl","nl","fr","es","pl","pt","cs","da","sv"] https://www.toolteam.com/en-GB/pce-occupational-health-and-safety-measuring-device-pce-hld-10-t-910025-4250348727633?dc=GB&cu=EUR 2026-08-02 270.46 United Kingdom GB DE 14
Forming gas, which is already commercially available for other engineering purposes and contains five percent hydrogen and ninety-five percent nitrogen, is well suited for leak testing. This industrial safety meter automatically detects the current hydrogen concentration of the environment each time it is turned on, and then evaluates changes only relative to that concentration. The reset button does the same during leak detection. If the leak location cannot be clearly identified even though all indicator LEDs are already lit, the reset function can be used to set the current hydrogen concentration as the base value and thus better narrow down the location of the leak.
Afterwards, the industrial safety measuring instrument can be reset to low initial values in an unstressed environment. Regardless of the output concentration level, one of three different sensitivity levels can be set on the industrial safety measuring device by pressing a button. The selected sensitivity is indicated by a labeled LED lighting up. The H” stands for high, the ”M” for medium and the ”L” for low. The hydrogen content in normal ambient air is 0.5 ppm. The sensitive device already detects concentrations of less than 5 ppm, i.e. 0.0005 percent. The sensor is located at the head of a semi-rigid 40-centimeter-long hose so that it can be easily guided to the component to be tested. To detect leaks, the sensor is moved slowly as close as possible along the areas to be tested. T-910025 PCE-HLD 10 4250348727633 en ["de","en","it","nl","nl","fr","es","pl","pt","cs","da","sv"] https://www.toolteam.com/en-GB/pce-occupational-health-and-safety-measuring-device-pce-hld-10-t-910025-4250348727633?dc=GB&cu=EUR 2026-08-02 270.46 United Kingdom GB DE 14