PCE Flow meter for fixed installation PCE-UFM 65PVC Thumbnail
PCE Flow meter for fixed installation PCE-UFM 65PVC Thumbnail
PCE Flow meter for fixed installation PCE-UFM 65PVC Thumbnail

 
PCE Flow meter for fixed installation PCE-UFM 65PVC
zoom_in
zoom_out
fullscreen
PCE Instruments brand logo
-25%

PCE Flow meter for fixed installation PCE-UFM 65PVC

Sku: T-1515520
€1,220.00 (excl. legal VAT, excl. Shipping)
€1,624.92 MSRP
In stock,
ready for shipping within 24h
Piece
 
Ask a question
Content:
1 Piece
Shipping:
€199.92 Versandservice to United Kingdom
For orders from €1,000.00 order total plus €34.45 Customs MRN registration
Lieferung:
Between 5. Jul and 10. Jul with today receipt of payment
If you order in the next 58 Minutes with Versandservice

Provider:
Sales and delivery by ToolTeam Köln
Payment methods:
Returns:
Security:

Product data

Manufacturer:
PCE Deutschland GmbH
Condition:
NEW
Sku:
T-1515520
SKU manufacturer:
PCE-UFM 65PVC
GTIN Code (EAN):
4250348734051
Weight:
1,58 Kg
All information relating to products from PCE Deutschland GmbH. Technical and optical modifications of the manufacturer and errors reserved. This page has been machine-translated, the original german version can be found here, please also note the Translation Disclaimer.

Product description

Our flow meter for fixed installation enables the measurement of flow velocity from 0.03 to 5 m/s. The flow meter can be used for measurements on PVC pipes with a diameter between 72 and 80 mm. The flow meter for fixed installation in the PCE-UFM-PVC series uses ultrasonic transit time measurement to determine velocity and flow volume. The flow meter has a separate external mounting device for easy installation without having to touch the liquid medium or stop production. Special coupling pads ensure that this ultrasonic clamp-on system can also be used without contact gel.

The flow meter for fixed installation is equipped with a 360° rotatable display that can be set in four directions (0°, 90°, 180°, 270°). The LCD colour display shows the flow rate, date, time, signal quality, network connection status, instantaneous speed and cumulative flow, among other things. The flow unit can be selected between m³, l and Gal.

The flow meter for fixed installation uses Power-over-Ethernet (PoE) for power supply and Ethernet communication to store data in the cloud. This allows users to access, manage and analyse their measurement data at any time and from any location via mobile devices or computers without interrupting production processes. In water and wastewater management, drinking water treatment or in industry, flow meters are used in processes where water is used as a coolant, cleaning agent or component of production processes. They help to optimise water consumption and control the process flow.

Velocity
Measuring range -32 ... +32 m/s
Resolution 0.001 m/s
Accuracy DN ≥50 mm: ±1.5 % v.Mw. for velocities >0.3 m/s / DN 0.3 m/s
Ultrasonic sensor
Designation PCE-TDS 200 S SENSOR
Pipe diameter DN 15 ... 100 mm / Ø 20 ... 108 mm
Dimensions ,
45 x 30 x 30 mm
Frequency 1 MHz
Operating temperature -30 ... 160 °C
Sensor cable length 5 m

Ultrasonic sensor
Designation PCE-TDS 200 M SENSOR
Pipe diameter DN 50 ... 700 mm / Ø 57 ... 720 mm
Dimensions 70 x 40 x 40 mm
Frequency 1 MHz
Temperature -30 ... 160 °C
Sensor cable length 5 m

Ultrasonic sensor
Designation PCE-TDS 200 L SENSOR
Pipe diameter DN 300 ... 6000 mm / Ø 300 ... 6000 mm
Dimensions 91 x 52 x 44 mm
Frequency 1 MHz
Temperature -30 ... 160 °C
Sensor cable length 5 m

General technical data
Measuring functions flow velocity, volume flow, volume
Unit(s) metric, imperial
Units Additional information Dimensions: mm, in,
Flow velocity: m/s, ft/s,
Volume flow: m³, l, gal, igl, mgl, cf, bal, ib, ob,
Volume: m³, l, gal, igl, mgl, cf, bal, ib, ob,
Time indication: Seconds, minutes, hours, days
Display size 2.8 inch
Storage medium Internal memory
Storage capacity 32 GB
Storage interval from 1 s
Storage interval up to 12 h
Interface USB-C
Tube material Steel, cast iron, stainless steel, Aluminium, brass, copper, PVC, iron, nickel, titanium, zinc, acrylic, polyethylene, polypropylene, nylon, user-defined (manual input of the transverse sound velocity of the pipe material)
Pipe material additional information Inner lining of the pipe: ,
- No lining,
- User-defined,
- Epoxy resin,
- Rubber,
- Mortar,
- Polystyrene ,
- Polyethylene ,
- Polytetrafluoroethylene ,
- Polyurethane ,
- Polypropylene ,
- User-defined (manual input of the longitudinal sound velocity of the inner lining of the pipe)
Measurement medium water, seawater, oil, crude oil, methanol, ethanol, diesel, petrol, paraffin, user-defined (manual input of the sound velocity of the medium)
Operating time 10 h
Automatic switch-off from . .. to 1 ... 15 min.
Automatic switch-off can be deactivated Yes
Measurement method Z, V, N, W
Alarm visual, audible
Alarm modes undershoot, overshoot, inside, outside
Reproducibility ±0.5 %
Menu language Turkish, English (US), Polish, Spanish, German, Chinese, Russian, Japanese, French, Danish, Italian, Dutch, Portuguese
Protection class (device) IP52
Power supply USB 5 VDC, 500 mA
Plug type device-Euro plug




Capacity 2500 mAh

Operating conditions -20 . .. 65 °C , 10 ... 95 % r. h.Storage conditions -20 ... 65 °C , 10 ... 95 % r. H. Dimensions ( L x W x H ) 165 x 85 x 32 mmWeight 263.5 g
1 x flow meter for fixed installation PCE-UFM 65PVC
1 x sensor with Ethernet cable 9 m
1 x PoE network cable 2 m
1 x ultrasonic contact gel
1 x silicone seal 1m
4 x coupling pad
1 x Allen key
1 x operating instructions