Product description
The EVSE measuring device is a robust installation tester with a large 3.5” TFT color LCD display. With the installation tester you can ensure that fixed installations are installed safely and correctly. Thanks to the dual display, the intuitive symbols and the high viewing angle you can carry out your measurements quickly and conveniently with the installation tester.
With the low-impedance measurement of the installation tester, you can check the grounding conductor, equipotential bonding rails and protective conductor for low-impedance continuity. The measuring range for the low-impedance measurement of the installation tester is in the range of 0...2000 ? with a resolution of 0.001...1 ?. Probably the most important measurement of the installation tester is the measurement of the insulation resistance. When measuring insulation, electrical lines are live in order to allow fault currents that cause material migration or heat to flow. In most cases, these residual currents are so minimal that they are not detected by protective devices and, in the worst case, can lead to a fire. The installation tester can perform the installation measurement with a test voltage of 125 V, 250 V, 500 V or 1000 V. The test current is 1 mA in each case. the
The installation tester’s grounding measurement is independent of the mains supply. In order to bring all systems and circuits of a power supply system to a common potential (reference earth or reference potential) and to protect against short-circuit currents and overvoltages, the earthing resistance should be as low as possible. With a measuring range of 0...2000 ? and a resolution of 0.01...1 ?, the installation tester offers all the prerequisites for a meaningful measurement of the earthing resistance.
EVSE adapter for charging plugs type 1 and 2 / PP and CP simulation / Schuko socket connection / direct acceptance of all connections via laboratory plug Electromobility is playing an increasingly important role. An important point is the charging stations for electric vehicles. Special measuring devices are required to check the permanently installed charging stations, also known as wall boxes, in order to check the function, the protective devices and the insulation. Measuring devices are often already available to carry out the required measurements. An adapter is therefore required so that the measuring device can be connected to the charging station. The EVSE adapter is specially designed for this application and already has a large number of functions. All lines that leave the charging station are output individually via laboratory plugs. Thus, all lines can be tapped via the EVSE adapter. This allows the charging station to be checked for insulation using the EVSE adapter. The EVSE adapter has a Schuko plug connection. The RCD tester can thus be used to check the residual current device. A charging cable not only contains the supply lines for charging an electric vehicle, but also two interfaces.
The electric vehicle communicates with the charging station via the CP line (Control Pilot) and communicates the current status of the electric vehicle. The PP line (proximity plug) is used for communication between the connected charging cable and the charging station. The charging cable can thus tell the charging station how many amps it can be loaded with. In order to test both functions, the EVSE adapter is equipped with appropriate simulators.
With the low-impedance measurement of the installation tester, you can check the grounding conductor, equipotential bonding rails and protective conductor for low-impedance continuity. The measuring range for the low-impedance measurement of the installation tester is in the range of 0...2000 ? with a resolution of 0.001...1 ?. Probably the most important measurement of the installation tester is the measurement of the insulation resistance. When measuring insulation, electrical lines are live in order to allow fault currents that cause material migration or heat to flow. In most cases, these residual currents are so minimal that they are not detected by protective devices and, in the worst case, can lead to a fire. The installation tester can perform the installation measurement with a test voltage of 125 V, 250 V, 500 V or 1000 V. The test current is 1 mA in each case. the
The installation tester’s grounding measurement is independent of the mains supply. In order to bring all systems and circuits of a power supply system to a common potential (reference earth or reference potential) and to protect against short-circuit currents and overvoltages, the earthing resistance should be as low as possible. With a measuring range of 0...2000 ? and a resolution of 0.01...1 ?, the installation tester offers all the prerequisites for a meaningful measurement of the earthing resistance.
EVSE adapter for charging plugs type 1 and 2 / PP and CP simulation / Schuko socket connection / direct acceptance of all connections via laboratory plug Electromobility is playing an increasingly important role. An important point is the charging stations for electric vehicles. Special measuring devices are required to check the permanently installed charging stations, also known as wall boxes, in order to check the function, the protective devices and the insulation. Measuring devices are often already available to carry out the required measurements. An adapter is therefore required so that the measuring device can be connected to the charging station. The EVSE adapter is specially designed for this application and already has a large number of functions. All lines that leave the charging station are output individually via laboratory plugs. Thus, all lines can be tapped via the EVSE adapter. This allows the charging station to be checked for insulation using the EVSE adapter. The EVSE adapter has a Schuko plug connection. The RCD tester can thus be used to check the residual current device. A charging cable not only contains the supply lines for charging an electric vehicle, but also two interfaces.
The electric vehicle communicates with the charging station via the CP line (Control Pilot) and communicates the current status of the electric vehicle. The PP line (proximity plug) is used for communication between the connected charging cable and the charging station. The charging cable can thus tell the charging station how many amps it can be loaded with. In order to test both functions, the EVSE adapter is equipped with appropriate simulators.
Hinweise zur Batterieentsorgung:
Da in unseren Sendungen Batterien und Akkus enthalten sein können, sind wir nach dem Batteriegesetz (BattG) verpflichtet, Sie auf Folgendes hinzuweisen:
- Batterien und Akkus dürfen nicht im Hausmüll entsorgt werden, sondern Sie sind zur Rückgabe gebrauchter Batterien und Akkus gesetzlich verpflichtet.
- Altbatterien können Schadstoffe enthalten, die bei nicht sachgemäßer Lagerung oder Entsorgung die Umwelt oder Ihre Gesundheit schädigen können. Batterien enthalten aber auch wichtige Rohstoffe wie z.B. Eisen, Zink, Mangan oder Nickel und können verwertet werden.
- Sie können die Batterien nach Gebrauch entweder an uns zurücksenden oder in unmittelbarer Nähe (z.B. im Handel oder in kommunalen Sammelstellen oder in unserem Lager) unentgeltlich zurückgeben.
- Die Abgabe in Verkaufsstellen ist dabei für Endnutzer auf die übliche Mengen sowie solche Altbatterien beschränkt, die der Vertreiber als Neubatterien in seinem Sortiment führt oder geführt hat.
- Das Zeichen mit der durchgekreuzten Mülltonne bedeutet, dass Sie Batterien und Akkus nicht im Hausmüll entsorgen dürfen
Unter diesen Zeichen finden Sie zusätzlich nachstehende Symbole mit folgender Bedeutung:
- Pb = Batterie enthält mehr als 0,004 Masseprozent Blei
- Cd = Batterie enthält mehr als 0,002 Masseprozent Cadmium
- Hg = Batterie enthält mehr als 0,0005 Masseprozent Quecksilber
Related results
pc
pce instruments
measurement technology
control technology
weighing technology
laboratory technology
development
production
calibration
pc
pce instruments
measurement technology
control technology
weighing technology
laboratory technology
development
production
calibration
pce
pce instruments
weighing technology
platform scales
shipping scales
pallet scales
inventory scales
platform scales
industrial scales
multifunctional scales
compact scales
weighing platform
pce
pce instruments
measurement technology
machines
systems
vibration measurement
vibration measuring device
vibration measuring device
accelerometer
stethoscope
data logger
Complete catalogs
The offer is aimed exclusively at business customers, companies, public institutions, tradesmen and freelancers. All prices in catalogues are exclusive of VAT, shipping costs and surcharges if applicable.
The manufacturer is exclusively responsible for the content, price and article details of the products and offers presented in the catalogues. Subject to technical and optical changes by the manufacturer and errors excepted.
The manufacturer is exclusively responsible for the content, price and article details of the products and offers presented in the catalogues. Subject to technical and optical changes by the manufacturer and errors excepted.
Product suggestions
-24%
Refractometer PCE-0100 Salinity
PCE-0100
€64.92
€84.92 MSRP
-25%
Kraftmessgerät
PCE-DFG 50K XF
€1,310.13
€1,744.92 MSRP
-24%
Wine Refractometer PCE-DRW 2
PCE-DRW 2
€266.68
€351.89 MSRP
-25%
Defectoscope PCE-FD 20
PCE-FD 20
€3,452.98
€4,598.90 MSRP
-25%
Coating Thickness Gauge PCE-CT 80HP-FN1D5
PCE-CT 80HP-FN1D5
€725.97
€966.89 MSRP
-25%
Drehmoment-Kalibrator
PCE-TCT 100
€4,223.32
€5,624.92 MSRP
-24%
Durometer PCE-DX-AS
PCE-DX-AS
€108.28
€142.90 MSRP
-24%
PCE-PH20M food penetration ph meter | robust PH electrode | recalibratable | waterproof (IP67)
PCE-PH20M
€329.58
€434.92 MSRP
-25%
torque measuring device PCE-TM 80
PCE-TM 80
€619.37
€824.92 MSRP
-24%
PCE-HS 300N Digital Crane Scale Weighing range (max.) 300 kg | incl. shackle + hook | Accurate ±1% of Mb. | Metal | LCD
PCE-HS 300N
€76.39
€99.91 MSRP
-24%
mold measuring device PCE-PMI 1BT
PCE-PMI 1BT
€89.41
€116.89 MSRP
-24%
PCE-DPG 3 Pressure Sensor Water & Gases | 1.4? NPT thread connection| 2.5? large display| Response time < 50 ms
PCE-DPG 3
€253.78
€334.92 MSRP
-24%
Earth Tester PCE-ET 3000
PCE-ET 3000
€399.29
€526.89 MSRP
-24%
PCE-BSH 6000 calibratable school scale max. 6 kg|PC software opt.|Counting function g|kg|lb|ct|gn|gsm and much more.
PCE-BSH 6000
€174.24
€229.91 MSRP
-24%
material test bench PCE-FTS50
PCE-FTS50
€439.45
€579.92 MSRP
No Review yet
Description: No Review yet
Written by: No Review
Rating: 5 out of 5
5 stars, based on 1
reviews
PCE-EVSE-KIT2 EVSE measuring device for checking fixed installation. Charging stations/wall boxes, variety of functions
pc
pce instruments
measurement technology
control technology
weighing technology
laboratory technology
development
production
calibration
pc
pce instruments
measurement technology
control technology
weighing technology
laboratory technology
development
production
calibration
pce
pce instruments
weighing technology
platform scales
shipping scales
pallet scales
inventory scales
platform scales
industrial scales
multifunctional scales
compact scales
weighing platform
pce
pce instruments
measurement technology
machines
systems
vibration measurement
vibration measuring device
vibration measuring device
accelerometer
stethoscope
data logger
The EVSE measuring device is a robust installation tester with a large 3.5” TFT color LCD display. With the installation tester you can ensure that fixed installations are installed safely and correctly. Thanks to the dual display, the intuitive symbols and the high viewing angle you can carry out your measurements quickly and conveniently with the installation tester.
With the low-impedance measurement of the installation tester, you can check the grounding conductor, equipotential bonding rails and protective conductor for low-impedance continuity. The measuring range for the low-impedance measurement of the installation tester is in the range of 0...2000 ? with a resolution of 0.001...1 ?. Probably the most important measurement of the installation tester is the measurement of the insulation resistance. When measuring insulation, electrical lines are live in order to allow fault currents that cause material migration or heat to flow. In most cases, these residual currents are so minimal that they are not detected by protective devices and, in the worst case, can lead to a fire. The installation tester can perform the installation measurement with a test voltage of 125 V, 250 V, 500 V or 1000 V. The test current is 1 mA in each case. the
The installation tester’s grounding measurement is independent of the mains supply. In order to bring all systems and circuits of a power supply system to a common potential (reference earth or reference potential) and to protect against short-circuit currents and overvoltages, the earthing resistance should be as low as possible. With a measuring range of 0...2000 ? and a resolution of 0.01...1 ?, the installation tester offers all the prerequisites for a meaningful measurement of the earthing resistance.
EVSE adapter for charging plugs type 1 and 2 / PP and CP simulation / Schuko socket connection / direct acceptance of all connections via laboratory plug Electromobility is playing an increasingly important role. An important point is the charging stations for electric vehicles. Special measuring devices are required to check the permanently installed charging stations, also known as wall boxes, in order to check the function, the protective devices and the insulation. Measuring devices are often already available to carry out the required measurements. An adapter is therefore required so that the measuring device can be connected to the charging station. The EVSE adapter is specially designed for this application and already has a large number of functions. All lines that leave the charging station are output individually via laboratory plugs. Thus, all lines can be tapped via the EVSE adapter. This allows the charging station to be checked for insulation using the EVSE adapter. The EVSE adapter has a Schuko plug connection. The RCD tester can thus be used to check the residual current device. A charging cable not only contains the supply lines for charging an electric vehicle, but also two interfaces.
The electric vehicle communicates with the charging station via the CP line (Control Pilot) and communicates the current status of the electric vehicle. The PP line (proximity plug) is used for communication between the connected charging cable and the charging station. The charging cable can thus tell the charging station how many amps it can be loaded with. In order to test both functions, the EVSE adapter is equipped with appropriate simulators. T-909997 PCE-EVSE-KIT2 4250348728463 en ["de","en","it","nl","nl","fr","es","pl","pt","cs","da","sv"] https://www.toolteam.com/en-GB/pce-evse-kit2-evse-measuring-device-for-checking-fixed-installation-charging-stations-wall-boxes-variety-of-functions-t-909997-4250348728463?dc=GB&cu=EUR 2026-07-14 923.45 United Kingdom GB DE 14
With the low-impedance measurement of the installation tester, you can check the grounding conductor, equipotential bonding rails and protective conductor for low-impedance continuity. The measuring range for the low-impedance measurement of the installation tester is in the range of 0...2000 ? with a resolution of 0.001...1 ?. Probably the most important measurement of the installation tester is the measurement of the insulation resistance. When measuring insulation, electrical lines are live in order to allow fault currents that cause material migration or heat to flow. In most cases, these residual currents are so minimal that they are not detected by protective devices and, in the worst case, can lead to a fire. The installation tester can perform the installation measurement with a test voltage of 125 V, 250 V, 500 V or 1000 V. The test current is 1 mA in each case. the
The installation tester’s grounding measurement is independent of the mains supply. In order to bring all systems and circuits of a power supply system to a common potential (reference earth or reference potential) and to protect against short-circuit currents and overvoltages, the earthing resistance should be as low as possible. With a measuring range of 0...2000 ? and a resolution of 0.01...1 ?, the installation tester offers all the prerequisites for a meaningful measurement of the earthing resistance.
EVSE adapter for charging plugs type 1 and 2 / PP and CP simulation / Schuko socket connection / direct acceptance of all connections via laboratory plug Electromobility is playing an increasingly important role. An important point is the charging stations for electric vehicles. Special measuring devices are required to check the permanently installed charging stations, also known as wall boxes, in order to check the function, the protective devices and the insulation. Measuring devices are often already available to carry out the required measurements. An adapter is therefore required so that the measuring device can be connected to the charging station. The EVSE adapter is specially designed for this application and already has a large number of functions. All lines that leave the charging station are output individually via laboratory plugs. Thus, all lines can be tapped via the EVSE adapter. This allows the charging station to be checked for insulation using the EVSE adapter. The EVSE adapter has a Schuko plug connection. The RCD tester can thus be used to check the residual current device. A charging cable not only contains the supply lines for charging an electric vehicle, but also two interfaces.
The electric vehicle communicates with the charging station via the CP line (Control Pilot) and communicates the current status of the electric vehicle. The PP line (proximity plug) is used for communication between the connected charging cable and the charging station. The charging cable can thus tell the charging station how many amps it can be loaded with. In order to test both functions, the EVSE adapter is equipped with appropriate simulators. T-909997 PCE-EVSE-KIT2 4250348728463 en ["de","en","it","nl","nl","fr","es","pl","pt","cs","da","sv"] https://www.toolteam.com/en-GB/pce-evse-kit2-evse-measuring-device-for-checking-fixed-installation-charging-stations-wall-boxes-variety-of-functions-t-909997-4250348728463?dc=GB&cu=EUR 2026-07-14 923.45 United Kingdom GB DE 14