zoom_in
zoom_out
fullscreen
-24%
PCE current data logger PCE-CR 10
Sku: T-909876
€250.00 (excl. legal VAT, excl. Shipping)
€329.91 MSRP
In stock,ready for shipping within 24h
Piece
Content:
1 Piece
Shipping:
€41.93 Versandservice to United Kingdom
Lieferung:
Provider:
Sales and delivery by ToolTeam Köln
Payment methods:
Returns:
Security:
Product data
Manufacturer:
PCE Deutschland GmbH
Condition:
NEW
Sku:
T-909876
SKU manufacturer:
PCE-CR 10
GTIN Code (EAN):
4250348719348
Weight:
0,27 Kg
All information relating to products from PCE Deutschland GmbH. Technical and optical modifications of the manufacturer and errors reserved.
This page has been machine-translated, the original german version can be found here, please also note the Translation Disclaimer.
Product description
The current data logger is used to log up to three 0/4 ... 20 mA signals. The current data logger stores the measured process currents on an SD card in Excel format. In addition to storing the measured values, the current data logger displays them on the large display. The maximum resolution here is 0.01 mA.
The measuring device is operated with 6 AA 1.5 V batteries or a power supply unit. For visualization of the live measured values, this current data logger can be connected to the PC via the serial interface. The current signals are given to the data logger via plug-in terminals. The plug-in terminals on the current data logger make it possible to change connected sensors with mA output relatively quickly and easily. This ensures that the current data logger can be used universally and flexibly in operation. A scaling of the measuring signal is not necessary, since the measured values are stored directly as mA. Scaling can then be conveniently performed manually in Excel.
Areas of application
The current data loggers are used to record output signals of numerous 0/4 ... 20 mA sensors, e.g. for pressure measurement or flow velocity monitoring. A monitoring, registration and evaluation of e.g. temperature, humidity, pressure, flow rate, pH value ... at production plants with standardized output signals 0 ... 20 mA can be done easily and accurately. Often, customers or suppliers also require proof of certain process parameters, which you as a manufacturer can conveniently store as a current signal at the machine. The current data logger PCE-CR 10 can be used almost everywhere where a stationary sensor or transmitter has to be tested temporarily.
The current data logger can also be used on sensors which have been developed by the mechanical properties to be used mobile. Also as a manufacturer of products itself one can store essential information during the operation of machines directly as a standard signal in the data logger and evaluate it later on the PC or laptop. Thus, the current data loggers also serve for machine monitoring or machine analysis. Adjustment / Calibration The current data logger PCE-CR 10 can be issued an ISO calibration certificate.
It is recommended to check, adjust and calibrate the data logger as standard. The calibration interval of the current data logger is usually specified in the internal quality manual. This calibration of the current data logger is performed in the calibration laboratory of PCE Instruments.
The measuring device is operated with 6 AA 1.5 V batteries or a power supply unit. For visualization of the live measured values, this current data logger can be connected to the PC via the serial interface. The current signals are given to the data logger via plug-in terminals. The plug-in terminals on the current data logger make it possible to change connected sensors with mA output relatively quickly and easily. This ensures that the current data logger can be used universally and flexibly in operation. A scaling of the measuring signal is not necessary, since the measured values are stored directly as mA. Scaling can then be conveniently performed manually in Excel.
Areas of application
The current data loggers are used to record output signals of numerous 0/4 ... 20 mA sensors, e.g. for pressure measurement or flow velocity monitoring. A monitoring, registration and evaluation of e.g. temperature, humidity, pressure, flow rate, pH value ... at production plants with standardized output signals 0 ... 20 mA can be done easily and accurately. Often, customers or suppliers also require proof of certain process parameters, which you as a manufacturer can conveniently store as a current signal at the machine. The current data logger PCE-CR 10 can be used almost everywhere where a stationary sensor or transmitter has to be tested temporarily.
The current data logger can also be used on sensors which have been developed by the mechanical properties to be used mobile. Also as a manufacturer of products itself one can store essential information during the operation of machines directly as a standard signal in the data logger and evaluate it later on the PC or laptop. Thus, the current data loggers also serve for machine monitoring or machine analysis. Adjustment / Calibration The current data logger PCE-CR 10 can be issued an ISO calibration certificate.
It is recommended to check, adjust and calibrate the data logger as standard. The calibration interval of the current data logger is usually specified in the internal quality manual. This calibration of the current data logger is performed in the calibration laboratory of PCE Instruments.
Hinweise zur Batterieentsorgung:
Da in unseren Sendungen Batterien und Akkus enthalten sein können, sind wir nach dem Batteriegesetz (BattG) verpflichtet, Sie auf Folgendes hinzuweisen:
- Batterien und Akkus dürfen nicht im Hausmüll entsorgt werden, sondern Sie sind zur Rückgabe gebrauchter Batterien und Akkus gesetzlich verpflichtet.
- Altbatterien können Schadstoffe enthalten, die bei nicht sachgemäßer Lagerung oder Entsorgung die Umwelt oder Ihre Gesundheit schädigen können. Batterien enthalten aber auch wichtige Rohstoffe wie z.B. Eisen, Zink, Mangan oder Nickel und können verwertet werden.
- Sie können die Batterien nach Gebrauch entweder an uns zurücksenden oder in unmittelbarer Nähe (z.B. im Handel oder in kommunalen Sammelstellen oder in unserem Lager) unentgeltlich zurückgeben.
- Die Abgabe in Verkaufsstellen ist dabei für Endnutzer auf die übliche Mengen sowie solche Altbatterien beschränkt, die der Vertreiber als Neubatterien in seinem Sortiment führt oder geführt hat.
- Das Zeichen mit der durchgekreuzten Mülltonne bedeutet, dass Sie Batterien und Akkus nicht im Hausmüll entsorgen dürfen
Unter diesen Zeichen finden Sie zusätzlich nachstehende Symbole mit folgender Bedeutung:
- Pb = Batterie enthält mehr als 0,004 Masseprozent Blei
- Cd = Batterie enthält mehr als 0,002 Masseprozent Cadmium
- Hg = Batterie enthält mehr als 0,0005 Masseprozent Quecksilber
Related results
pc
pce instruments
measurement technology
control technology
weighing technology
laboratory technology
development
production
calibration
pc
pce instruments
measurement technology
control technology
weighing technology
laboratory technology
development
production
calibration
pce
pce instruments
weighing technology
platform scales
shipping scales
pallet scales
inventory scales
platform scales
industrial scales
multifunctional scales
compact scales
weighing platform
pce
pce instruments
measurement technology
machines
systems
vibration measurement
vibration measuring device
vibration measuring device
accelerometer
stethoscope
data logger
Complete catalogs
The offer is aimed exclusively at business customers, companies, public institutions, tradesmen and freelancers. All prices in catalogues are exclusive of VAT, shipping costs and surcharges if applicable.
The manufacturer is exclusively responsible for the content, price and article details of the products and offers presented in the catalogues. Subject to technical and optical changes by the manufacturer and errors excepted.
The manufacturer is exclusively responsible for the content, price and article details of the products and offers presented in the catalogues. Subject to technical and optical changes by the manufacturer and errors excepted.
Product suggestions
-24%
PCE-PH20M food penetration ph meter | robust PH electrode | recalibratable | waterproof (IP67)
PCE-PH20M
€329.58
€434.92 MSRP
-25%
vehicle measuring device PCE-CT 80HP-FN3
PCE-CT 80HP-FN3
€747.02
€994.92 MSRP
-24%
Wine Refractometer PCE-DRW 2
PCE-DRW 2
€266.68
€351.89 MSRP
-24%
Borescope PCE-VE 200SV1
PCE-VE 200SV1
€363.69
€479.92 MSRP
-24%
PCE-BSH 10000 calibratable industrial scale max. 10 kg | piece counting function | USB | g | kg | lb | ct | gn | gsm and much more.
PCE-BSH 10000
€164.37
€216.89 MSRP
-25%
AW tester PCE-WAM 10
PCE-WAM 10
€579.57
€771.89 MSRP
-24%
mold measuring device PCE-PMI 1BT
PCE-PMI 1BT
€89.41
€116.89 MSRP
-25%
PCE-900 Leeb hardness tester for metals |200 ... 900 HL|± 0.8% at HLD=900 |HL |HRC|HRB|HB|HV|HSD
PCE-900
€600.59
€799.91 MSRP
-25%
Feuchtebestimmerwaage
PCE-UX 3011HQ
€2,995.80
€3,990.00 MSRP
-25%
Borescope PCE-VE 380N
PCE-VE 380N
€1,614.20
€2,149.91 MSRP
-24%
Durometer PCE-DX-AS
PCE-DX-AS
€108.28
€142.90 MSRP
-24%
Radon Monitor
PCE-RD 75
€143.91
€189.91 MSRP
-24%
material test bench PCE-FTS50
PCE-FTS50
€439.45
€579.92 MSRP
-25%
torque measuring device PCE-TM 80
PCE-TM 80
€619.37
€824.92 MSRP
-25%
Hydraulic lifting table - industrial scale PCE-HLTS 500
PCE-HLTS 500
€3,266.01
€4,349.91 MSRP
No Review yet
Description: No Review yet
Written by: No Review
Rating: 5 out of 5
5 stars, based on 1
reviews
PCE current data logger PCE-CR 10
pc
pce instruments
measurement technology
control technology
weighing technology
laboratory technology
development
production
calibration
pc
pce instruments
measurement technology
control technology
weighing technology
laboratory technology
development
production
calibration
pce
pce instruments
weighing technology
platform scales
shipping scales
pallet scales
inventory scales
platform scales
industrial scales
multifunctional scales
compact scales
weighing platform
pce
pce instruments
measurement technology
machines
systems
vibration measurement
vibration measuring device
vibration measuring device
accelerometer
stethoscope
data logger
The current data logger is used to log up to three 0/4 ... 20 mA signals. The current data logger stores the measured process currents on an SD card in Excel format. In addition to storing the measured values, the current data logger displays them on the large display. The maximum resolution here is 0.01 mA.
The measuring device is operated with 6 AA 1.5 V batteries or a power supply unit. For visualization of the live measured values, this current data logger can be connected to the PC via the serial interface. The current signals are given to the data logger via plug-in terminals. The plug-in terminals on the current data logger make it possible to change connected sensors with mA output relatively quickly and easily. This ensures that the current data logger can be used universally and flexibly in operation. A scaling of the measuring signal is not necessary, since the measured values are stored directly as mA. Scaling can then be conveniently performed manually in Excel.
Areas of application
The current data loggers are used to record output signals of numerous 0/4 ... 20 mA sensors, e.g. for pressure measurement or flow velocity monitoring. A monitoring, registration and evaluation of e.g. temperature, humidity, pressure, flow rate, pH value ... at production plants with standardized output signals 0 ... 20 mA can be done easily and accurately. Often, customers or suppliers also require proof of certain process parameters, which you as a manufacturer can conveniently store as a current signal at the machine. The current data logger PCE-CR 10 can be used almost everywhere where a stationary sensor or transmitter has to be tested temporarily.
The current data logger can also be used on sensors which have been developed by the mechanical properties to be used mobile. Also as a manufacturer of products itself one can store essential information during the operation of machines directly as a standard signal in the data logger and evaluate it later on the PC or laptop. Thus, the current data loggers also serve for machine monitoring or machine analysis. Adjustment / Calibration The current data logger PCE-CR 10 can be issued an ISO calibration certificate.
It is recommended to check, adjust and calibrate the data logger as standard. The calibration interval of the current data logger is usually specified in the internal quality manual. This calibration of the current data logger is performed in the calibration laboratory of PCE Instruments. T-909876 PCE-CR 10 4250348719348 en ["de","en","it","nl","nl","fr","es","pl","pt","cs","da","sv"] https://www.toolteam.com/en-GB/pce-current-data-logger-pce-cr-10-t-909876-4250348719348?dc=GB&cu=EUR 2026-07-14 250 United Kingdom GB DE 14
The measuring device is operated with 6 AA 1.5 V batteries or a power supply unit. For visualization of the live measured values, this current data logger can be connected to the PC via the serial interface. The current signals are given to the data logger via plug-in terminals. The plug-in terminals on the current data logger make it possible to change connected sensors with mA output relatively quickly and easily. This ensures that the current data logger can be used universally and flexibly in operation. A scaling of the measuring signal is not necessary, since the measured values are stored directly as mA. Scaling can then be conveniently performed manually in Excel.
Areas of application
The current data loggers are used to record output signals of numerous 0/4 ... 20 mA sensors, e.g. for pressure measurement or flow velocity monitoring. A monitoring, registration and evaluation of e.g. temperature, humidity, pressure, flow rate, pH value ... at production plants with standardized output signals 0 ... 20 mA can be done easily and accurately. Often, customers or suppliers also require proof of certain process parameters, which you as a manufacturer can conveniently store as a current signal at the machine. The current data logger PCE-CR 10 can be used almost everywhere where a stationary sensor or transmitter has to be tested temporarily.
The current data logger can also be used on sensors which have been developed by the mechanical properties to be used mobile. Also as a manufacturer of products itself one can store essential information during the operation of machines directly as a standard signal in the data logger and evaluate it later on the PC or laptop. Thus, the current data loggers also serve for machine monitoring or machine analysis. Adjustment / Calibration The current data logger PCE-CR 10 can be issued an ISO calibration certificate.
It is recommended to check, adjust and calibrate the data logger as standard. The calibration interval of the current data logger is usually specified in the internal quality manual. This calibration of the current data logger is performed in the calibration laboratory of PCE Instruments. T-909876 PCE-CR 10 4250348719348 en ["de","en","it","nl","nl","fr","es","pl","pt","cs","da","sv"] https://www.toolteam.com/en-GB/pce-current-data-logger-pce-cr-10-t-909876-4250348719348?dc=GB&cu=EUR 2026-07-14 250 United Kingdom GB DE 14