fischer Anchor channel systems catalogue Page 43
Commercial customer offer**Top sellers from Fischer
fischer catalogue Cast-in Channel Systems Channel bolt installation parameter Vmin/size Vmin Channel bolt thread [mm] M10 14.5 M12 117 M16 20.5 M20 26 Figure: Channel bolt and channel lip dimensions lreq f tfix tw Vmin 3 Cast-in Channel system lip thickness f Thickness Profile [mm] H-S-29/20 5.2 H-S-38/23 6 H-40/22 6.2 H-50/30 8.1 H-52/34 11.5 C-28/15 2.3 C-38/17 3.0 C-40/25 6.0 C-49/30 7.0 C-54/33 8.5 lreq = required bolt length tfix = thickness of clamped component f = profile lip thinkness tw = washer thickness vmin = nut height EN ISO 4032 + overhang approximately 5 mm (for M20: 7 mm) 42