Pneumax - Fittings and accessories Page 112
Commercial customer offer**Top sellers from Pneumax GmbH
300 ® raccordi in acciaio inox • stainless steeel fittings Esito dei test di compatibilità alle specifiche FDA effettuati da TEST REPORT N. DATA DURATA (GIORNI) COMPONENTE SS per conto del produttore MATERIALE OBIETTIVO DEL TEST A TRHZ1208110 06/08/2012 6 GUARNIZIONE DI TENUTA VITON FPM FLUORORUBBER (FKM) CONFORMITA’ ALLE SPECIFICHE FDA PER DETERMINARE IL GRADO DI ESTRAZIONE DI CLOROFORMIO SOLUBILE (ppm) NELLE GUARNIZIONI DI TENUTA PER CHIUSURA DI CONTENITORI ALIMENTARI B TRHZ1208111 06/08/2012 6 RACCORDO AD L MOD. SSV ACCIAO INOSSIDABILE SUS316L DETERMINAZIONE DEL CONTENUTO TOTALE DI CROMO C TRHZ1208112 06/08/2012 6 RACCORDO DIRITTO ACCIAO INOSSIDABILE MOD. SSC-G SUS316L DETERMINAZIONE DEL CONTENUTO TOTALE DI CROMO METODO DEL TEST (ref. FDA 21 CFR 177.1210) RISULTATO IMMERSIONE PER 2 ORE IN ACQUA DISTILLATA A212°F VALORE RILEVATO 13,0 VALORE LIMITE 50,0 IMMERSIONE PER 2 ORE IN ALCOHOL 8% A 212°F VALORE RILEVATO 7,0 VALORE LIMITE 50,0 IMMERSIONE PER 2 ORE IN EPTANO NORMALE (N-EPTANO) A 150 °F VALORE RILEVATO 11,5 VALORE LIMITE 50,0 B ANALISI VOLUMETRICA (TITOLAZIONE) VALORE RILEVATO 16,38% VALORE RICHIESTO >=10,5% IL RISULTATO DEL TEST SUL CAMPIONE PRESENTATO DETERMINA CHE ESSO E’ IDONEO AL CONTATTO CON GLI ALIMENTI C ANALISI VOLUMETRICA (TITOLAZIONE) VALORE RILEVATO 17,18% VALORE RICHIESTO >=10,5% IL RISULTATO DEL TEST SUL CAMPIONE PRESENTATO DETERMINA CHE ESSO E’ IDONEO AL CONTATTO CON GLI ALIMENTI A CONCLUSIONI Test results to FDA specifications compatibility, made by IL RISULTATO DEL TEST SUI CAMPIONI PRESENTATI SONO CONFORMI ALLE SPECIFICHE FDA PER DETERMINARE LA QUANTITA’ DI ESTRATTIVI DI CLOROFORMIO SOLUBILE AMMESSI on behalf of the manufacturer TEST REPORT N. DATE PERIOD (DAYS) ITEM MAIN MATERIAL TEST PURPOSE A TRHZ1208110 06/08/2012 6 SEAL RING FPM FLUORORUBBER VITON (FKM) THE COMPLIANCE WITH THE FOOD AND DRUG ADMINISTRATION REGULATIONS FOR DETERMINING THE AMOUNT OF CHLOROFORM-SOLUBLE EXTRACTIVES (ppm) FROM CLOSURES WITH SEALING GASKETS FOR FOOD CONTAINERS B TRHZ1208111 06/08/2012 6 ELBOW FITTING MOD. SSV STAINLESS STEEL SUS316L TO DETERMINE TOTAL CHROMIUM CONTENT IN THE SUBMITTED SAMPLE 6 STRAIGHT FITTING MOD. SSC-G STAINLESS STEEL SUS316L TO DETERMINE TOTAL CHROMIUM CONTENT IN THE SUBMITTED SAMPLE C TRHZ1208112 06/08/2012 TEST METHOD (ref. FDA 21 CFR 177.1210) TEST RESULT IMMERSION FOR 2 HOURS IN DISTILLED WATER AT 212 ° F DETECTED VALUE 13,0 MAX PERMISSIBLE 50,0 IMMERSION FOR 2 HOURS IN ALCOHOL 8% AT 212°F DETECTED VALUE 7,0 MAX PERMISSIBLE 50,0 IMMERSION FOR 2 HOURS IN n-HEPTANE AT 150°F DETECTED VALUE 11,5 MAX PERMISSIBLE 50,0 B TITRATION METHOD DETECTED VALUE 16,38% REQUIREMENT >=10,5% WHEN TESTED AS SPECIFIED, THE TEST RESULTS OF THE SUBMITTED SAMPLE IS SUITABLE FOR CONTACT WITH FOOD C TITRATION METHOD DETECTED VALUE 17,18% REQUIREMENT >=10,5% WHEN TESTED AS SPECIFIED, THE TEST RESULTS OF THE SUBMITTED SAMPLE IS SUITABLE FOR CONTACT WITH FOOD A CONCLUSION WHEN TESTED AS SPECIFIED, THE TEST RESULTS OF THE SUBMITTED SAMPLE COMPLY WITH THE FDA SPECIFICATIONS FOR DETERMINING THE AMOUNT OF CHLOROFORM-SOLUBLE EXTRACTIVES FOR CLOSURES (CLOS) 110 dimensioni di ingombro e informazioni tecniche sono fornite a puro titolo informativo e possono essere soggette a modifica senza preavviso
220 Pages | Valid until 06/2025 | Previous page | Next page
Choose your language
Legal issues
The manufacturer is exclusively responsible for the content, price and article details of the products and offers presented in the catalogues. Subject to technical and optical changes by the manufacturer and errors excepted.
Request form for special products
The ToolTeam® Procurement Service
Are you looking for products that are shown in the catalogue but cannot be purchased directly online?Our procurement service will be pleased to make you a non-binding and individual offer.
