Pneumax - Hauptkatalog Page 539
Commercial customer offer**Top sellers from Pneumax GmbH
Solenoid valves manifold Series 2500 "OPTYMA-T" - Serial systems Configurator Manifold Layout configuration INPUT MODULES A = No module D1= 8 M8 digital inputs module D2= 8 M12 digital inputs module T1= 2 analogue inputs 0-5V module T2= 2 analogue inputs 0-10V module C1= 2 analogue inputs 0-20mA module C2= 2 analogue inputs 4-20mA module P1= 2 Pt100 inputs 2 wires module P2= 2 Pt100 inputs 3 wires module E1= 2 Pt100 inputs 2 wires module extended range E2= 2 Pt100 inputs 3 wires module extended range A3 = 37 poles - Self feeding E3 = 37 poles - External feeding 32 OUT VERSION ® C3 = CANopen 32OUT D3 = DeviceNet 32OUT P3 = PROFIBUS 32OUT ® A3 = EtherCAT 32OUT (5700 Series) I3 = EtherNet / IP 32OUT N3 = PROFINET IO RT/IRT 32OUT T __ . __ ... __ . MODULE CONFIGURATION Valve type __ __ . __ __ ... ... RIGHT ENDPLATE U0 = Closed U2 = 25 Poles U3 = 37 Poles 1 I/O MODULE M8 (Requires 25 poles right endplate) . __ . __ __ ACCESSORIES CONFIGURATION Sub-base type __ . . . SHORT CODE FUNCTION / CONNECTION : A1= 5/2 Sol.-Spring + BASE 1 - CARTR. G1/8” GAS A2= 5/2 Sol.-Spring + BASE 2 - CARTR. G1/8” GAS A3= 5/2 Sol.-Spring + BASE 1 - CARTR. Ø4 A4= 5/2 Sol.-Spring + BASE 2 - CARTR. Ø4 A5= 5/2 Sol.-Spring + BASE 1 - CARTR. Ø6 A6= 5/2 Sol.-Spring + BASE 2 - CARTR. Ø6 A7= 5/2 Sol.-Spring + BASE 1 - CARTR. Ø8 A8= 5/2 Sol.-Spring + BASE 2 - CARTR. Ø8 B1= 5/2 Sol.-Diff. + BASE 1 - CARTR. G1/8” GAS B2= 5/2 Sol.-Diff. + BASE 2 - CARTR. G1/8” GAS B3= 5/2 Sol.-Diff. + BASE 1 - CARTR. Ø4 B4= 5/2 Sol.-Diff. + BASE 2 - CARTR. Ø4 B5= 5/2 Sol.-Diff. + BASE 1 - CARTR. Ø6 B6= 5/2 Sol.-Diff. + BASE 2 - CARTR. Ø6 B7= 5/2 Sol.-Diff. + BASE 1 - CARTR. Ø8 B8= 5/2 Sol.-Diff. + BASE 2 - CARTR. Ø8 C2= 5/2 Sol.-Sol. + BASE 2 - CARTR. G1/8” GAS C4= 5/2 Sol.-Sol. + BASE 2 - CARTR. Ø4 C6= 5/2 Sol.-Sol. + BASE 2 - CARTR. Ø6 C8= 5/2 Sol.-Sol. + BASE 2 - CARTR. Ø8 E2= 5/3 CC Sol.-Sol. + BASE 2 - CARTR. G1/8” GAS E4= 5/3 CC Sol.-Sol. + BASE 2 - CARTR. Ø4 E6= 5/3 CC Sol.-Sol. + BASE 2 - CARTR. Ø6 E8= 5/3 CC Sol.-Sol. + BASE 2 - CARTR. Ø8 F2= 2x3/2 NC-NC (= 5/3 OC) Sol.-Sol. + BASE 2 - CARTR. G1/8” GAS F4= 2x3/2 NC-NC (= 5/3 OC) Sol.-Sol. + BASE 2 - CARTR. Ø4 F6= 2x3/2 NC-NC (= 5/3 OC) Sol.-Sol. + BASE 2 - CARTR. Ø6 F8= 2x3/2 NC-NC (= 5/3 OC) Sol.-Sol. + BASE 2 - CARTR. Ø8 G2= 2x3/2 NO-NO (= 5/3 PC) Sol.-Sol. + BASE 2 - CARTR. G1/8” GAS G4= 2x3/2 NO-NO (= 5/3 PC) Sol.-Sol. + BASE 2 - CARTR. Ø4 G6= 2x3/2 NO-NO (= 5/3 PC) Sol.-Sol. + BASE 2 - CARTR. Ø6 G8= 2x3/2 NO-NO (= 5/3 PC) Sol.-Sol. + BASE 2 - CARTR. Ø8 H2= 2x3/2 NC-NO Sol.-Sol. + BASE 2 - CARTR. G1/8” GAS H4= 2x3/2 NC-NO Sol.-Sol. + BASE 2 - CARTR. Ø4 H6= 2x3/2 NC-NO Sol.-Sol. + BASE 2 - CARTR. Ø6 H8= 2x3/2 NC-NO Sol.-Sol. + BASE 2 - CARTR. Ø8 I2= 2x3/2 NO-NC Sol.-Sol. + BASE 2 - CARTR. G1/8” GAS I4= 2x3/2 NO-NC Sol.-Sol. + BASE 2 - CARTR. Ø4 I6= 2x3/2 NO-NC Sol.-Sol. + BASE 2 - CARTR. Ø6 I8= 2x3/2 NO-NC Sol.-Sol. + BASE 2 - CARTR. Ø8 T1= Free valve space plug + BASE 1 - CARTR. G1/8” GAS T2= Free valve space plug + BASE 2 - CARTR. G1/8” GAS T3= Free valve space plug + BASE 1 - CARTR. Ø4 T4= Free valve space plug + BASE 2 - CARTR. Ø4 T5= Free valve space plug + BASE 1 - CARTR. Ø6 T6= Free valve space plug + BASE 2 - CARTR. Ø6 T7= Free valve space plug + BASE 1 - CARTR. Ø8 T8= Free valve space plug + BASE 2 - CARTR. Ø8 ACCESSORIES While configuring the manifold always be careful that the maximum number of electrical signals available is 32. The use of monostable valve mounted on a base type 2 ( 2 electrical signals occupied ) causes the loss of one electric signal. In this case the monostable valve can be replaced by a bistable valve. The diaphragms plugs are used to intercept the conduits 1,3 & 5 of the base. If it is necessary to interrupt more than one conduit in the same time then put in line the letters which identifies the position (for exemple : regarding the 3 & 5 conduits, put the Y & Z letters). Should one or more conduits be cut more than one time it is necessary to add the relevant intermediate Supply/Exhaust module. U2 = Electric and electro-pneumatic cut off module 2 positions K2 = Electric and electro-pneumatic cut off module 2 positions with external pilot U4 = Electric and electro-pneumatic cut off module 4 positions K4 = Electric and electro-pneumatic cut off module 4 positions with external pilot U6 = Electric and electro-pneumatic cut off module 6 positions K6 = Electric and electro-pneumatic cut off module 6 positions with external pilot U8 = Electric and electro-pneumatic cut off module 8 positions K8 = Electric and electro-pneumatic cut off module 8 positions with external pilot W = Intermediate supply & exhaust module X = Diaphragm plug on pipe 1 Y = Diaphragm plug on pipe 33 Z = Diaphragm plug on pipe 5 XY = Diaphragm plug on pipe 1 & 3 ZX = Diaphragm plug on pipe 5 & 1 ZY = Diaphragm plug on pipe 5 & 3 ZXY = Diaphragm plug on pipe 5, 1 & 3 Overall dimensions and technical information are provided solely for informative purposes and may be modified without notice 1 | 519 Air distributiOn LEFT ENDPLATE
1106 Pages | Valid until 06/2025 | Previous page | Next page
Choose your language
Legal issues
The manufacturer is exclusively responsible for the content, price and article details of the products and offers presented in the catalogues. Subject to technical and optical changes by the manufacturer and errors excepted.
Request form for special products
The ToolTeam® Procurement Service
Are you looking for products that are shown in the catalogue but cannot be purchased directly online?Our procurement service will be pleased to make you a non-binding and individual offer.
