Pneumax - Hauptkatalog Page 419
Commercial customer offer**Top sellers from Pneumax GmbH
Solenoid valves manifold ISO 15407-2 Series 2700 - Serial systems Configurator Manifold Layout configuration INPUT MODULES 32 OUT VERSION C3 = CANopen® 32OUT D3 = DeviceNet 32OUT P3 = PROFIBUS 32OUT ® A3 = EtherCAT 32OUT (5700 Series) I3 = EtherNet / IP 32OUT N3 = PROFINET IO RT 32OUT L3 = Powerlink 32OUT M3 = Modbus/TCP 32OUT V27 __ . __ ... __ MODUL CONFIGURATION Valve type __ __ Sub-base type __ . __ . __ __ __ ... S.V. POWER RIGHT ENDPLATE U0 = Closed U2 = 25 Poles 1 I/O MODULE M8 (Requires 25 poles right endplate) ... . __ . __ __ ACCESSORIES CONFIGURATION E3 = S.V. 2,3W E5 = S.V. 1W . . . SUB-BASE TYPE 1 = Base type 1 for Monostable (1 electrical signal occupied) 2 = Base type 2 for Bistable (2 electrical signals occupied) ACCESSORIES X VALVE TYPE: A = Self-feeding E = External feeding SHORT CODE FUNCTION / CONNECTION : A= 5/2 SOLENOID - SPRING B= 5/2 SOLENOIS - DIFFERENTIAL C= 5/2 SOLENOID - SOLENOID E= 5/3 CC SOLENOID -SOLENOID F= 2x3/2 NC-NC (= 5/3 OC) SOLENOID -SOLENOID G= 2x3/2 NO-NO (= 5/3 PC) SOLENOID -SOLENOID H= 2x3/2 NC-NO SOLENOID -SOLENOID I= 2x3/2 NO-NC SOLENOID -SOLENOID T= FREE VALVE SPACE PLUG = Diaphragm plug on pipe 1 Y = Diaphragm plug on pipe 3 Z = Diaphragm plug on pipe 5 XY = Diaphragm plug on pipe 1 & 3 ZX = Diaphragm plug on pipe 5 & 1 ZY = Diaphragm plug on pipe 5 & 3 ZXY = Diaphragm plug on pipe 5, 1 & 3 NOTE: While configuring the manifold always be careful that the maximum number of electrical signals available is 32. The use of monostable valve mounted on a base type 2 ( 2 electrical signals occupied ) causes the loss of one electric signal. In this case the monostable valve can be replaced by a bistable valve. The diaphragms plugs are used to intercept the conduits 1,3 & 5 of the base. If it is necessary to interrupt more than one conduit in the same time then put in line the letters which identifies the position (for exemple : regarding the 3 & 5 conduits, put the Y & Z letters). Should one or more conduits be cut more than one time it is necessary to add the relevant intermediate Supply/Exhaust module. Overall dimensions and technical information are provided solely for informative purposes and may be modified without notice 1 | 399 Air distributiOn A = No module D1= 8 M8 digital inputs module D2= 8 M12 digital inputs module T1= 2 analogue inputs 0-5V module T2= 2 analogue inputs 0-10V module C1= 2 analogue inputs 0-20mA module C2= 2 analogue inputs 4-20mA module P1= 2 Pt100 inputs 2 wires module P2= 2 Pt100 inputs 3 wires module E1= 2 Pt100 inputs 2 wires module extended range E2= 2 Pt100 inputs 3 wires module extended range
1106 Pages | Valid until 06/2025 | Previous page | Next page
Choose your language
Legal issues
The manufacturer is exclusively responsible for the content, price and article details of the products and offers presented in the catalogues. Subject to technical and optical changes by the manufacturer and errors excepted.
Request form for special products
The ToolTeam® Procurement Service
Are you looking for products that are shown in the catalogue but cannot be purchased directly online?Our procurement service will be pleased to make you a non-binding and individual offer.
