Hymer - Climbing Ladders Page 9
Commercial customer offer**Top sellers from HYMER
DIN 14094-1 ESCAPE LADDER / FIRE ESCAPE / ESCAPE ROUTE Continuous fall protection on request · From an access height of 10,000 mm, the ladder must be · · installed with offset. The max. length of a ladder section must not exceed 6,000 mm. The top rung must be at the exit level. The offsets are to be positioned at equal intervals, but can also be planned at different heights using the online configurator. The distance from the rung-leading-edge to the wall must be at least 150 mm. Exit: The gap between the vertical ladder and the exit level must not exceed 75 mm. For a standard wall distance between ladder and building of 210 mm, this gap is provided by using an exit step. Fastening: The standard wall mounting has a gap of 210 mm from the stile axis to the building. The distance between the individual fastening points must not exceed 2,000 mm. They should preferably be attached directly below the rungs. · · Safety cage: · Distance from the lowest safety cage clamp to the floor: 2,200 mm to 3,000 mm. · Safety cage required from a height of 3,000 mm. 9
40 Pages | Valid until 12/2025 | Previous page | Next page
Choose your language
Legal issues
The manufacturer is exclusively responsible for the content, price and article details of the products and offers presented in the catalogues. Subject to technical and optical changes by the manufacturer and errors excepted.
Request form for special products
The ToolTeam® Procurement Service
Are you looking for products that are shown in the catalogue but cannot be purchased directly online?Our procurement service will be pleased to make you a non-binding and individual offer.