TOX product catalogue Page 80
Commercial customer offer**Top sellers from TOX-DÜBEL
Injection mortar Liquix Plus 7 Liquix Pro 7 in concrete C20/25 M8 M10 M12 M16 M20 M24 Effective anchoring depth 60-160 mm 60-200 mm 70-240 mm 80-320 mm 90-400 mm 96-480 mm Permissible central tension load of a single wall plug without environmental effects Nzul in uncracked concrete C20/25 Threaded rod galvanised, property class 5.8 510-860 kg 600-1380 kg 840-2000 kg 1280-3760 kg 1710-5860 kg 1880-8430 kg Threaded rod A4, property class 70 510-1090 kg 600-1730 kg 840-2520 kg 1280-4740 kg 1710-7370 kg 1880-10600 kg Permissible shear load of a single wall plug without environmental effects Vzul in uncracked concrete C20/25 Threaded rod galvanised, property class 5.8 510 kg 860 kg 1200 kg 2230 kg 3490 kg 5030 kg Threaded rod A4, property class 70 600 kg 920 kg 1370 kg 2520 kg 3940 kg 5510 kg Component dimensions and installation characteristics Minimum axis distance smin 40 mm 50 mm 60 mm 80 mm 100 mm 120 mm Minimum edge distance cmin 40 mm 50 mm 60 mm 80 mm 100 mm 120 mm Minimum component thickness hmin |----------------------- hef + 30 mm ≥ 100 mm -----------------------| |------------------------------- hef + 2d0 -------------------------------| Drill core diameter d0 10 mm 12 mm 14 mm 18 mm 24 mm 28 mm Drill hole depth h1 ≥ 60-160 mm 60-200 mm 70-240 mm 80-320 mm 90-400 mm 96-480 mm Through hole in the component to be connected df ≤ 9 mm 12 mm 14 mm 18 mm 22 mm 26 mm Torque when anchoring Tinst 10 Nm 20 Nm 40 Nm 80 Nm 120 Nm 160 Nm Chemical / Heavy Duty The specified loads refer to anchorings of a single anchor in wet and dry concrete as well as for anchorings from -40° C to +24° C (or briefly up to +40° C) When sizing, the entire declaration of performance of the Liquix Plus 7 must be observed The partial safety factors of the resistances specified in the approval and a partial safety factor of γF = 1.4 are to be considered. Approved wall plugs must be used for fixings where safety is of importance (see also www.tox.de/safety+loads) Curing times for injection mortar Liquix Plus 7: Concrete temperature Processing time Minimum curing time -5 to -1° C 90 min. 360 min. 0 to +4 ° C 45 min. 180 min. +5 to +9° C 25 min. 120 min. +10 to +14° C 20 min. 100 min. +15 to +19° C 15 min. 80 min. +20 to +29° C 6 min. 45 min. +30 to +34° C 4 min. 25 min. +35 to +39° C 2 min. 20 min. The cartridge temperature must be between +5° to + 40° C 80
216 Pages | Valid until 12/2023 | Previous page | Next page
Choose your language
Legal issues
The manufacturer is exclusively responsible for the content, price and article details of the products and offers presented in the catalogues. Subject to technical and optical changes by the manufacturer and errors excepted.
Request form for special products
The ToolTeam® Procurement Service
Are you looking for products that are shown in the catalogue but cannot be purchased directly online?Our procurement service will be pleased to make you a non-binding and individual offer.