CELO main catalog Page 117
Commercial customer offer**Products from catalog page
CELO ResiTHERM® 37 technical data ResiTHERM® 37S Installation parameters ResiTHERM® 37/120 ResiTHERM® 37/160 ResiTHERM® 37/200 Anchor length Ld [mm] 125 245 285 325 7KLFNQHVVRILQVXODWLRQPDWHULDO LQFOH[WHUQDOSODVWHU hD [mm] 0 601) - 120 1201) - 160 1601) - 200 Anchor Ø dnom [mm] 37 Drill hole Ø d0 [mm] 39 - 40 Drill hole depth h1 ͡ [mm] 130 Anchorage depth hnom [mm] 125 ± 102) [mm] M12 hVPLQPD[ [mm] 35 - 80 223) Connecting thread Screw insertion depth of M12 threaded stud 7KLFNQHVVRIͤ[WXUH tͤ[͠ [mm] RIFOHDUDQFHKROHLQͤ[WXUH df ͡ [mm] Required volume of ResiFIX VY per ResiTHERM® 37 ,QVWDOODWLRQWRUTXHIRUPRXQWLQJWKHͤ[WXUH 13 [ml] Tinst͠ ca. 140 [Nm] 20 ResiTHERM® 37 may be cut up to 40 mm if needed. ResiTHERM® 37/120 M12: If thickness of insulation material is 60 mm, set 20 mm deeper. 2) Minimum anchorage depth of 115 mm is possible (see ETA assessment) 3) When using a threaded stud with L=70 mm. Otherwise a longer threaded stud or a longer metric screw can be used. 1) Loads and displacements/deflections ResiTHERM®37: approved system with injection system ResiFIX VY SF Building material System Thickness of insulation material [mm] Permissible tension load Hollow brick T1.0-240 HLZ 12 (Format 12 DF) Hollow brick T10-300 HLZ 6 (Format 10 DF) Aerated concrete AAC2-0,352) Aerated concrete AAC4-0,552) Single fastening Single fastening Single fastening Single fastening all all all all Permissible pressure load Hollow brick T1.0-240 HLZ 12 (Format 12 DF) Hollow brick T10-300 HLZ 6 (Format 10 DF) Single fastening Single fastening all all Permissible shear load Single fastening Hollow brick T1.0-240 HLZ 12 (Format 12 DF) Double fastening3) Single fastening Hollow brick T10-300 HLZ 6 (Format 10 DF) Double fastening3) 0 120 160 200 0 120 160 200 0 120 160 200 0 120 160 200 * Movement of ResiTHERM® 37 in load direction at permissible load. Recommended loads include the partial safety factor on action of ɶF = 1,4. Not part of the ETA-assessment. 3) Spacing of 77 mm (standard awning console). 4) Ǝv0 ,QLWLDOGHIOHFWLRQƎY͜= long-term deflection 1) 2) Application of ResiTHERM® 37 in solid building materials is possible. Contact CELO for details. 116 Recommended loads1) Deflection at recommended load* Nper [kN] ɷN0ͬɷEь [mm] 1,71 0,86 1,21 2,12 0,60/ 1,30 0,60/ 1,20 0,14/ 0,28 0,32/ 0,64 Fper [kN] ɷF0ͬɷ&ь[mm] 1,71 0,86 0,60/ 1,30 0,60/ 1,20 Vper [kN] ɷv0ͬɷǀь [mm] 4) 0,86 0,34 0,34 0,26 0,51 0,43 0,34 0,41 0,43 0,26 0,26 0,17 0,17 0,11 0,11 0,09 0,20/ 0,30 2,00/ 4,10 2,10/ 4,30 3,40/ 6,70 0,60/ 1,20 1,60/ 3,20 0,70/ 1,40 1,40/ 2,90 0,00/ 0,10 1,30/ 2,60 1,70/ 2,50 2,00/ 4,00 0,10/ 0,20 0,20/ 0,30 0,20/ 0,30 0,30/ 0,50
316 Pages | Valid until 03/2023 | Previous page | Next page
Choose your language
Legal issues
The manufacturer is exclusively responsible for the content, price and article details of the products and offers presented in the catalogues. Subject to technical and optical changes by the manufacturer and errors excepted.
Request form for special products
The ToolTeam® Procurement Service
Are you looking for products that are shown in the catalogue but cannot be purchased directly online?Our procurement service will be pleased to make you a non-binding and individual offer.